• Title/Summary/Keyword: Optometry

Search Result 579, Processing Time 0.024 seconds

Comparison of Tear Distributions by the Corneal Eccentricity when Fitted with Spherical and Aspherical RGP Lenses (구면 및 비구면 RGP렌즈 피팅 시 각막 이심률별 눈물분포 비교)

  • Kim, Jihye;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.2
    • /
    • pp.99-108
    • /
    • 2016
  • Purpose: The present study was aimed to compare the tear volume and distribution by corneal eccentricity when fitted with spherical and aspherical RGP lenses. Methods: Spherical and aspherical RGP lenses were fitted in best alignment on a total of 77 subjects (136 eyes) in their twenties and thirties without any ocular disease or ocular surgery experience. The tear volume was analyzed by estimating the concentration of tear stained with fluorescein in the center of RGP lens as well as at the mid-peripheral and peripheral areas, and the difference of tear distributions was analyzed according to corneal eccentricity. Results: Tear distribution from the center to the peripheral area was not significantly different when spherical RGP lenses were fitted on the corneal eccentricities of e < 0.38 and $0.68{\leq}e$, indicating the relatively even tear distribution compared with other corneal eccentricity. In the case of aspherical RGP lenses, the difference of tear distribution between the central and peripheral areas was smaller than spherical RGP lenses. The significant difference of tear distribution according to RGP lens design was observed in the corneal eccentricity of 0.48 < e < 0.68. In other words, more even tear distribution was shown when aspherical RGP lenses were fitted on the cornea with eccentricity of $0.48{\leq}e<0.68$ and spherical RGP lenses were fitted on the cornea with eccentricity $0.68{\leq}e$. Furthermore, tear volume in the mid-peripheral area increased with higher corneal eccentricity. Conclusions: The results suggest that the appropriate selection of RGP lens design according to corneal eccentricity is necessary since tear volume and distribution by the regions of spherical and aspherical lenses are affected by corneal eccentricity.

Visual fatigue in Watching 3 Dimension Television (3D TV 시청에 있어서 시청 피로)

  • Yoon, Jeong Ho;Lee, Ikhan;Kim, Taehyun;Kim, Jae-Do
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.1
    • /
    • pp.47-52
    • /
    • 2012
  • Purpose: This study was to evaluate visual fatigue with passing of watching 3D TV in short term and with experience of watching 3DTV in long term. Methods: 98 adult subjects aged $33.5{\pm}5.5$ years (22 to 51 years; 12 females and 86 males) agreed to participate in this study. Subjects were asked to watch 52 inch LED 2D and 3D television (Shutter glasses method) at 2.7 meters for 65minutes with wearing their habitual glasses or contact lenses. For evaluating visual fatigue, subjects were verbally responded to 11 questions : eye straining, eye paining, dry eye, sore eye, watery eye, photophobia, blur vision, diplopia, eye fatigue, headache, and dizziness with scale 0 to 3 at each measurement while watching 3D and 2D TV. Results: The mean scores of visual fatigue were $2.08{\pm}2.14$, $3.19{\pm}3.02$, $3.40{\pm}3.37$, $3.53{\pm}3.07 $for after 5 minutes, 25 minutes, 45 minutes, and 65 minutes respectively for 3D TV, and $0.40{\pm}1.03$, $0.22{\pm}0.70$, $0.22{\pm}0.58$, and $0.17{\pm}0.52$ after 25, 45, and 65 minutes respectively for 2D TV. Visual fatigue for watching 3D TV was significantly higher than for watching 2D TV at all measurements sessions (paired t-test, p < 0.001). The visual fatigue significantly increased during watching 3D TV for 65 minutes (p < 0.001, RM-ANOVA). The visual fatigue during watching 3D TV was significantly increased until 25 minutes (paired t-test, p < 0.001), stable after that. For correlation between visual fatigue and 3D watching experience, the more 3D watching experiences were significantly the less visual fatigues in photophobia, blur vision, diplopic and dizzy symptoms (ANOVA, all F(1, 96) = 4.500, all p < 0.05), but there was not significantly different in the other symptoms (ANOVA, F (1, 96) = 2.123, p = 0.148). Conclusions: Visual fatigue for watching 3D TV was higher than for watching 2D TV, increase by 25 minutes. It was different by symptoms for correlation between visual fatigue and 3D watching experience.

The Comparison of Fluorescein Patterns between Spherical RGP Lens and Aspherical RGP Lens by Corneal Type and Astigmatic Degree (각막형상과 난시도에 따른 구면 RGP 렌즈와 비구면 RGP 렌즈의 플루레신 염색 패턴 비교)

  • Park, Eun Hye;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.1
    • /
    • pp.37-45
    • /
    • 2012
  • Purpose: The change of alignment between RGP lens and cornea according to the lens design was investigated by comparing the areas of fluorescein pattern in central and peripheral regions analyzed by astigmatic degree and corneal type when spherical and aspherical RGP lenses fitted in alignment. Methods: The fluorescein patterns of 90 eyes (19-30 years, $25.12{\pm}3.52$) having with-the-rule astigmatism were analyzed after spherical and aspherical RGP lenses fitted in alignment. Then, their fluorescent areas in central and peripheral regions were calculated and compared for the quantitative evaluation. Results: The case showing concordant base curve between spherical and aspherical RGP lenses in alignment fitting was 72% however, the possibility to have same base curves between spherical and aspherical RGP lenses in alignment fitting was to be less in the case of symmetric bowtietyped cornea and high astigmatism. The fluorescent area in peripheral region of aspherical RGP lens in alignment fitting was smaller than it of spherical RGP lens. Peripheral fluorescent areas in both RGP lenses decreased according to the increase of astigmatic degree and peripheral area in symmetric bowtie-typed corea was smaller than round-typed cornea's peripheral area. In the case of same astigmatic degree, peripheral fluorescent area of aspherical RGP lens was smaller in both corneal types. Conclusions: The results above suggest the changing degree in the alignment between RGP lens and cornea can be varied according to lens design, corneal astigmatism and corneal type. Thus, the results obtained from the quantitative analysis of the alignment between lens design and cornea may be used as the basic information about the establishment of guidelines for RGP lens fitting, the development of proper lens design, and different tear volume in partial regions.

Contact Lens Prescribing Pattern in Korean During 2010 to 2013 (대한민국의 최근 4년간(2010-2013) 콘택트렌즈 처방 추세)

  • Lee, Jong-Ha;Lee, Ki-Seok;Chu, Byoung-Sun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.3
    • /
    • pp.323-329
    • /
    • 2014
  • Purpose: To understand the pattern of prescribing contact lenses in Korea from 2010 to 2013. Methods: Four hundred survey questionnaires were randomly posted to Korean Optometric clinics for 4 years. The questionnaire was the same form as a form used for International Contact Lens Prescribing Trend. It was also designed to collect information about the contact lenses prescribed to the first 10 patients after its receipt. Results: 1937 fits were used for the analysis among the four hundred survey questionnaires. The average patient age was $26.2{\pm}7.0$ in 2010, $26.1{\pm}7.6$ in 2011, $24.7{\pm}6.6$ in 2012 and $24.8{\pm}7.2$ in 2013. The patients were mainly women (75%). Of all the soft contact lenses, silicon hydrogel lenses were 18% of fits (17% in 2010, 10% in 2011, 20% in 2012, 24% in 2013). By degine, the percentage of toric design lenses accounted for 17% of soft lenses fits and had increased during 4 years (10% in 2010, 18% in 2011, 16% in 2012, 22% in 2013), and cosmetic contact lens made up for 29% (15% in 2010, 20% in 2011, 40% in 2012, 41% in 2013). Conclusions: The contact lenses wearers were mostly women and the average patient age becomes slightly younger. In relation to the increase in the mumber of younger female contact lens wearers,the percentage of cosmetic lenses prescription was much higher (29%) than the global average (7%), and it has gradually increased for last 4 years. This trend could be related to the growth of beauty market in Korea. By emphasizing on toric lens marketing in manufactures, the prescription rate has been gradually increased.

The Evaluation of Reliability for the Combined Refractive Power of Overlapping Trial Lenses (중첩된 시험렌즈의 합성굴절력에 대한 신뢰도 평가)

  • Lee, Hyung Kyun;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.3
    • /
    • pp.263-276
    • /
    • 2015
  • Purpose: The current study aimed to evaluate the reliability for the combined refractive power when a spherical lens and a cylindrical lens were overlapped in a trial frame. Methods: The refractive powers, central thickness and peripheral thickness of spherical trial lenses and cylindrical lenses with negative power were measured. The combined refractive power of the spherical and cylindrical lenses was measured by auto lens meter. Measurement was repeated by changing the insertion order, and their results were further compared with the calculated combined refractive power. Results: There was no correlation between the variation of central and peripheral thickness in trial lenses and that of the lens power. Among 79 trial lenses, 3 trial lenses wasn't met the international standard. The refractive power calculated by Gullstrand's formula that could compensate vertex distance had smaller difference with the estimated power when compared with that calculated by thin lens formula however, it was significantly different from the estimated power. The refractive powers were generally apparent regardless of the insertion order of a spherical lens and a cylindrical lens: thin lens formula > actual measurements > Gullstrand's formula. The error was only found in cylindrical power calculated by Gullstrand's formula when inserted a spherical lens inside and a cylindrical lens outside however, the error was found in both of cylindrical and spherical powers calculated by Gullstrand's formula when inserted as a opposite order. By comparing actual measurements of equivalent spherical power, the accuracy was higher and the possibility of over-correction was lower when inserted a spherical lens inside and a cylindrical lens outside. Conclusions: From the results, those were revealed that the combined refractive power is influenced by the factors other than the vertex distance and the refractive power varies in accordance with the insertion order of a spherical lens and a cylindrical lens. Thus, it can be suggested that the establishment of standard for these is neccesaty.

Influence of Different Diagnostic Criteria on Frequency of Convergence Insufficiency (진단기준 차이가 폭주부족의 빈도에 미치는 영향)

  • Yu, Dong-Sik;Cho, Hyun Gug;Moon, Byeong-Yeon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.3
    • /
    • pp.235-242
    • /
    • 2016
  • Purpose: This study was to investigate whether the application of different diagnostic criteria affected the frequency of convergence insufficiency (CI). Methods: Eighty one subjects with mean age of 22.54 years (20 to 27 years) were evaluated. Binocularity tests after refraction were performed as the following tests: near point of convergence (NPC) with an accommodative target, phoria using von Graefe method, positive fusional vergence (PFV) with a phoropter. Subjects with CI were diagnosed when exophoria (exo) was greater at near than at distance ($exo{\geq}4{\Delta}$, or >$6{\Delta}$), fusional vergence was $PFV{\leq}11{\Delta}$ for blur, $PFV{\leq}15{\Delta}$ for break, Sheard's or Percival's criterion, and NPC was $NPC{\geq}6cm$, ${\geq}7.5cm$ or >10 cm. Results: Frequency of CI with one diagnostic criterion was ranged from 6.2% to 77.8%, and was overestimated or underestimated according to criteria. It was reduced to the range of 6.2% to 43.2% with diagnostic criteria more than two, especially to the range of 24.7% to 28.4% with lower variability in diagnostic criteria including phoria and Sheard's criterion. There were high relationship between total score of signs and phoria score (r = 0.772, p<0.001), and measured phoria and Sheard's criterion (r = -0.654, p<0.001), but NPC had a high variability and a weak or no significant relationship with other diagnostic criteria. Results suggested $exo{\geq}4{\Delta}$, Sheard's criterion and $NPC{\geq}7.5cm$ for diagnostic criteria of signs and sequence for CI. Conclusions: Frequency of CI is likely to be over- and underestimated with diagnostic criteria. Cutoff values and procedures for phoria, Sheard's criterion and NPC as clinical signs should be suggested definitely in diagnosis associated with CI.

Comparison of In Vitro Lipid Deposition and Change of Optical Characteristics on Daily Disposable Lenses (1-day) and 3-days Lenses Over 3 days (3-days lenses와 daily disposable lenses(1-day)의 착용 시간 별 지방 침착량 및 광학적 특성 변화의 비교)

  • Song, Sun Jung;Lee, Su Yeon;Kim, Ki Hong;Chu, Byoung Sun
    • Journal of the Korean Chemical Society
    • /
    • v.64 no.2
    • /
    • pp.67-73
    • /
    • 2020
  • The study aimed to investigate in vitro lipid deposition of oleic acid, oleic acid methyl ester and cholesterol on a daily disposable (1-day lenses) and 3-days lenses over 3 days and changes of optical characteristics is also investigated. Artificial tear solutions were prepared to simulate actual tear compositions. Two types of contact lenses (1-day lenses (Senofilcon A) and 3-days lenses (silicone tripolymer)) were soaked in the artificial tear solutions within an incubator at 37 ℃ with 150 rpm for 8, 16, 24 hours. Lipid deposition (oleic acid, oleic acid methyl ester and cholesterol) were measured using high performance liquid chromatography (HPLC) instrument. In addition, measurements of oxygen transmissibility, light transmittance and observation of lens surface were conducted. The amount of lipid deposition on the 1-day lenses were 127.55 ㎍/lens for Day 1, 302.96 ㎍/lens, for Day 2, and 353.30 ㎍/lens for Day 3. The 3-days lenses were 46.22 ㎍/lens for Day 1, 66.07 ㎍/lens for Day 2, and 67.45 ㎍/lens for Day 3. Oxygen transmissibility were 81×10-9(cm/sec)(ml O2/ml×mmHg)(Baseline) and 48×10-9(cm/sec)(ml O2/ml×mmHg) (Day 3) for the 1-day lenses, it were 13.23×10-9(cm/sec)(ml O2/ml×mmHg)(Baseline) and 9.6×10-9(cm/sec)(ml O2/ml×mmHg) (Day 3) for the 3-days lenses. Transmittance of each lenses were 97.21% (Baseline) and 94.25% (Day 3) for the 1-day lenses, 97.65% (Baseline) and 95.15% (Day 3) for the 3-days lenses. Observation of surface deposition indicated greatest deposition for the 3-days lenses type on Day 3. Lipid deposition for both lens types increased by day and was greater for the 1-day lenses type. Surface deposition appeared to differ as it was greatest for the 3 days lens type, which may suggest other deposits such as protein may be present.

Physical Properties of the Hydrogel Using Alginate (Alginate가 포함된 하이드로겔의 물리적 특성)

  • Woo, Chul-min;Heo, Seongin;Lee, Hyun Mee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.4
    • /
    • pp.463-469
    • /
    • 2015
  • Purpose: A hydrogel including alginate and $CaCl_2$ extracted from seaweed was manufactured, and their physical properties were investigated. Also, its applicability as contact lenses was examined. Methods: A film-type sample used in this experiment was manufactured using 2-hydroxyethyl methacrylate (HEMA), which is the raw material of hydrogel contact lenses; azobisiobutyonitile (AIBN), which is an initiator and ethylenglycoldimethacrylate (EGDMA), which is a cross-linking agent. It was hydrated in a PBS solution for 24 hours, and an interpenetrating polymer network (IPN) was formed in 1% and 2% alginate and 1%, 3%, and 5% $CaCl_2$ solutions for 24 hours, respectively. Results: The measurement of the physical properties of the film after the IPN showed that the moisture content was 30.89~36.89%, the refractive index was 1.431~1.441, the contact angle was $62.98{\sim}80.45^{\circ}$, and the tensile strength was 2.378~4.215 ($gf/mm^2$). Also, the physical properties hardly changed as the content of alginate increased, and the moisture content decreased as the content of $CaCl_2$ increased. As a result of the IPN, the moisture content and contact angle decreased compared to those of basic HEMA, but the tensile strength increased. The tensile strength of the second IPN was higher than that of the first IPN. In the case of $CaCl_2$, for the sample polymerized for 24 hours and the second IPN sample with 2% alginate, the contact angle decreased as the content of $CaCl_2$ increased. Conclusions: In this study, the tensile strength increased as the content of $CaCl_2$ increased, and the wettability increased as a result of IPN of alginate and $CaCl_2$. The hydrogel containing the alginate and $CaCl_2$ was confirmed possible utilization as contact lens material.

A Comparison of the Contact Areas between Cornea and RGP Lenses by Fitting Status (피팅 상태에 따른 RGP 렌즈와 각막과의 간극 비교)

  • Park, Eun Hye;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.3
    • /
    • pp.255-264
    • /
    • 2012
  • Purpose: In this study, the effect of lens fitting status on the contact area between spherical/aspherical RGP lens and the cornea having different astigmatic degree and corneal type was investigated for guiding the proper selection of RGP lens. Methods: Spherical and aspherical RGP lenses were applied on ninety eyes $(25.12{\pm}3.52years)$ having with-the-rule astigmatism by different fitting status. Then, their central, mid-peripheral and peripheral areas of fluorescein pattern were calculated and compared for the quantitative evaluation of the contact area between spherical/aspherical RGP lens. Results: The central and peripheral areas with the alignment fitting was significant different based on lens design. However, the central area didn't show any significant difference by lens design and corneal type when fitted in steep or flat. When analyzed by the corneal shape, both lenses with alignment and flat fitting had significant difference in central and peripheral areas. However, the central, mid-peripheral and peripheral areas with steep fitting didn't show the difference by corneal types. When analyzed by the astigmatic degree, the central and peripheral areas with alignment fitting changed proportionally to the increase of corneal astigmatism regardless of corneal shape. With steep and flat fitting, however, the central, mid-peripheral and/or peripheral areas in round- and symmetric bowtie-typed corneas showed the conflicting result when compared to those of alignment fitting when analyzed by the astigmatic degree. Conclusions: In this study, it was confirmed that the contact areas of cornea and RGP lens fitted steep and flat status were largely affected by the corneal type and corneal astigmatism rather than RGP lens fitted in alignment status. Also, this result commonly occurred in both spherical and aspherical RGP lenses.

Adsorption Properties of the Lysozyme and Albumin with Physicochemical Properties of the Contact Lens (콘택트렌즈의 물리화학적 특성에 따른 라이소자임과 알부민의 흡착 특성)

  • Sung, Yu-Jin;Ryu, Geun-Chang;Jun, Jin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.3
    • /
    • pp.261-270
    • /
    • 2013
  • Purpose: Adsorption properties of lysozyme and albumin according to physiochemical properties of commercial contact lens classified with the FDA categories and a contact lens fabricated in the laboratory were investigated. Methods: The contact lens were prepared using HEMA(2-hydroxyethyl methacrylate) and TRIM(3-(trimethoxysilyl) propyl methacrylate) in a cast mold. Artificial tears containing lysozyme and albumin were prepared. We measured the amounts of protein adsorbed on the each lenses with varying adsorbed time (48 hour) and the pH range (6, 6.8, 7.4, 8.2, 9) of artificial tear. Amount of the proteins absorbed on the contact lenses were measured by using HPLC. Results: Time to reach the equilibrium of protein adsorption for silicone hydrogel lens was taken longer than hydrogel lens. The amount of adsorbed both lysozyme and albumin at equilibrium were greater for the hydrogel lens than the silicone hydrogel lens, and larger for the ionic lens than the non-ionic lens. Lysozyme was more adsorbed on the higher water content of contact lens, whereas albumin was more adsorbed on the lower water content of contact lens. Only lysozyme was adsorbed on the Group IV hydrogel lens of ionic higher water content. The adsorption of protein on contact lens increased with pH of artificial tears as close to the isoelectric point of each protein. Conclusions: The adsorption amount of lysozyme is more affected by the ionic strength of the contact lens surface than the water content of contact lens. Albumin adsorption is more affected by water content than the ionic strength of the contact lens surface. For the adsorption of proteins on the silicone hydrogel lens, the pore size, determined both by the number of Si atoms and the chemical structure of the silicone-containing monomers, as well as the polarity of contact lens should be also considered.