• Title/Summary/Keyword: Optimum replacement

Search Result 273, Processing Time 0.026 seconds

Optimum Inspection and Replacement Policy in Redundant System

  • Yun, Won Young;Cha, Myung Soo
    • Journal of Korean Society for Quality Management
    • /
    • v.19 no.2
    • /
    • pp.78-85
    • /
    • 1991
  • In this paper, an inspection and replacement policy in a redundant system is considered. It is assumed that the state of the redundant system is known by inspection. When the system is inspected, it is preventively replaced only if the number of failed units exceeds the predetermined limit. Otherwise, the system is inspected after a inspection interval which depends on the number of failed units. We obtain the optimal number of redundant units, inspection intervals and replacement limit minimizing the expected cost rate.

  • PDF

AN EXPERIMENTAL STUDY ON HIGH STRENGTH CONCRETE FOR REPLACEMENT METHOD OF MINERAL ADMIXTURES (혼화재의 치환방법에 따른 고강도 콘크리트의 실험적 연구)

  • 권영호;박정국;안재현;박칠림
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1992.10a
    • /
    • pp.5-10
    • /
    • 1992
  • The aim of this study is to decide the optimum replacement method when mineral Admistures as SILCA FUME and FLY ASH are used, as a part of practical use of ultra High-Strength Concrete. For this purpose, Four types of replacement methods are examined and the relationship between replacement methods and concrete properties is studied. As a result, workability and gain of strength are dependent on the replacement method of mineral Admixtures. The methods of using volumn ratio of cement in FIY ASH, weight ratio of cement in SILCA FUME are shown better workability and strength of concrete than any other replacement method.

  • PDF

On the New Age Replacement Policy (새로운 연령교체 방식의 개발)

  • Seo, Sun-Keun
    • Journal of Applied Reliability
    • /
    • v.16 no.4
    • /
    • pp.280-286
    • /
    • 2016
  • Purpose: Recently, Jiang defines the tradeoff B life to minimize a sum of life lost by preventive maintenance (PM) and corrective maintenance (CM) contribution parts and sets up an optimal replacement age of age replacement policy as this tradeoff life. In this paper, Jiang's model only considering the known lifetime distribution is extended by assigning different weights to two parts of PM and CM in order to reflect the practical maintenance situations in application. Methods: The new age replacement model is formulated and the meaning of a weight factor is expressed with the implied cost of failure under asymptotic expected cost model and also discussed with one-cycle expected cost criterion. Results: The proposed model is applied to Weibull and lognormal lifetime distributions and optimum PM replacement ages are derived with corresponding implied cost of failure. Conclusion: The new age replacement policy to escape the estimation of cost of failure in classical asymptotic expected cost criterion based on the renewal process is provided.

The Study on the Optimum Mix Design of the High-Strength Concrete in Site (고강도 콘크리트의 현장최적배합에 관한 연구)

  • Lee, Sang-Soo;Won, Cheol;Kim, Dong-Seok;Ahn, Jae-Hyun;Park, Chil-Lim
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1996.10a
    • /
    • pp.232-238
    • /
    • 1996
  • In this paper, the properties of high-strength concrete are described with respect to materials and mix conditions(water-cement ratio, chemical admixture, replacement of fly ash). As primary purposes of this study, the optimum mix design method of high-strength concrete to decrease unit cement contents is investigated, and the properties of fresh and hardened concretes are tested in terms of slump, air content and compressive strength. As results of this study, workability and strength development of the high-strength concrete depend on the water-cement ratio, replacement ratio of fly ash and dosage of the chemical admixture. The conditions which are proposed optimum mix design of the high-strength concrete show W/C 37%, S/A 42~45% and unit cement content 470~480kg/$\textrm{m}^3$. Based on the results, the applicability of high-strength concrete in site is clearly proved.

  • PDF

Crack Analysis of CFRD Face Slab Concrete Using Blended Fiber (Blended 섬유를 사용한 CFRD 표면 차수벽 콘크리트의 균열발생 가능성 분석)

  • Woo, Sang-Kyun;Song, Young-Chul
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.653-656
    • /
    • 2008
  • The main purpose of this research was to enhance the durability in both the design and construction of dams. Especially, in case of rockfill dams, the durability of face slab concrete in a concrete-faced rockfill dam(CFRD) is achieved by optimizing the fly ash replacement for cement and application of blended fiber. The effect on durability and thermal property corresponding to the increasing replacement of fly ash and application of blended fiber was evaluated, and the optimum value of fly ash replacement and blended fiber application was recommended. The results show that 15% of fly ash replacement and 0.9kg/m3 of blended fiber application was found to be an optimum level and demonstrated excellent performance in durability and thermal property.

  • PDF

Optimum Mix Proportion of the High Strength and Self Compacting Concrete Used Above-Ground LNG Storage Tank (지상식 LNG 저장탱크용 고강도 자기충전 콘크리트의 최적배합에 관한 연구)

  • Kwon, Yeong-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.1
    • /
    • pp.99-107
    • /
    • 2011
  • This study is to performed to find the optimum mix proportion of the high strength and self compacting concrete for the above-ground LNG storage tank construction and field application. If LNG storage tank wall thicknesscan be reduced, the construction cost and quality can be improved by using self-compacting high strength concrete with compressive strength 60~80 MPa. For this purpose, low heat cement (Type IV) and class F fly ash are used in concrete mix to control hydration heat, flowability, and viscosity. Mix design variables of unit water, fly ash replacement ratio, water-binder ratio, and fine aggregate ratio are selected and tested for material properties and manufacturing cost of the concrete. Also, fly ash replacement ratio is considered using confined water ratio test. The test results showed that the optimum mix proportion of the self-compacting high strength concrete characteristics are as follows. 1) In case of the concrete with specified compressive strength of 60 MPa, the optimum mix proportion is fly ash replacement ratio of 20% and water- binder ratio of 27~30%. 2) In case of the concrete with the strength of 80 MPa, the optimum mix proportion is fly ash replacement ratio of 10% and water-binder ratio 25%. But unit water and fine aggregate ratio are 165 $kg/m^3$ and $51{\pm}2%$, respectively, regardless of the traget concrete compressive strength range. Also, test results showed that concrete manufacturing cost of 60 MPa and 80 MPa concrete require additional costs of 14~22% and 33%, respectively, compared to the manufacturing cost of 40 MPa concrete. Therefore, application of the self-compacting high strength concrete has proven to be economical in the perspective of the material cost, quality control, and site management.

Periodic Replacement of a System Subject to Shocks under Random Operating Horizon (랜덤한 운용시평하에서 충격 시스템의 보전방안)

  • Yoo, Youngkwan
    • Journal of the Korea Safety Management & Science
    • /
    • v.23 no.4
    • /
    • pp.105-112
    • /
    • 2021
  • This paper presents a periodic replacement policy for a system subject to shocks when the system is operating for a finite random horizon. The system is subject to shocks during operation, and each shock causes downgrading of the system performance and makes it more expensive to run by the additional running cost. Shocks arrive according to a nonhomogeneous or a renewal process, and we develop periodic replacement policies under a finite random operating horizon. The optimum periodic replacement interval which minimizes the total operating cost during the horizon is found. Numerical examples are presented to demonstrate the results.

Derivation of Optimum GGBFS Replacement with Durability Design Parameters (내구성 설계 변수에 따른 최적 고로슬래그 미분말의 치환율 도출)

  • Jang, Seung-Yup;Yoon, Yong-Sik;Kwon, Seung-Jun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.6 no.1
    • /
    • pp.36-42
    • /
    • 2018
  • GGBFS(Ground Granulated Blast Furnace Slag)-replacement is very effective for improving resistance to chloride attack and this can induce a long service life for RC(Reinforced Concrete) structures exposed to chlorides. In the work, the design parameters such as cover depth, surface chloride content, critical chloride content, and replacement ratio of GGBFS are considered, and optimum replacement ratio of GGBFS are derived with intended service life. The changes of surface chloride content and cover depth show 3.16~3.38 and 3.02~3.34 times of service life variation, which are most influencing parameters. Critical chloride content shows 1.53~1.57 times of service life variation regardless of w/b(Water to Binder) ratios. In the case of surface chloride content $18.0kg/m^3$, the most severe condition, cover depth over 70 mm and GGBFS replacement ratio over 42% are required with concrete containing w/b ratio under 0.42 for 100 years of intended service life. The condition of $13.0kg/m^3$, GGBFS replacement over 35% is required. For reasonable durability design, quantitative exterior condition and critical chloride content should be determined, and the criteria in Domestic Specification is evaluated to be conservative.

An Alternative Approach for Further Approximate Optimum Inspection Intervals

  • Francis, Leung Kit-Nam
    • Industrial Engineering and Management Systems
    • /
    • v.7 no.1
    • /
    • pp.1-8
    • /
    • 2008
  • Having previously presented an article entitled "Further approximate optimum inspection intervals" in this Journal, here the author derives an alternative set of general explicit formulae using Cardan's solution to a cubic equation and presents a modified heuristic algorithm for solving Baker's model. The examples show that this new alternative approximate solution procedure for determining near optimum inspection intervals is as accurate and computationally efficient as the one suggested in the previous article. Through the examples, the author also indicates the relative merits and demerits of the two algorithms.

An Experimental Study on the Properties of Admixtures for Concrete (콘크리트용 혼화재의 특성에 관한 실험적 연구)

  • Bae, Su-Ho;Chung, Young-Soo;Park, Kwang-Su;Lee, Joon-Gu
    • Magazine of the Korea Concrete Institute
    • /
    • v.11 no.2
    • /
    • pp.115-125
    • /
    • 1999
  • The purpose of this experimental research is to investigate the properties of workability and strength of the concrete containing admixtures such as silica fume, fly ash, ground granulated blast-furnace slag, and rice husk ash. For this purpose, the workability and the strength of the concrete containing each admixture were tested and analyzed according to the unit weight of binder and the replacement ratio of each admixture. As a result, considering their workability and strength, the existence of minimum binder weight and optimum replacement ratio of concrete containing admixture to plain concrete were obtained for each admixture.