• Title/Summary/Keyword: Optimum rate

Search Result 4,170, Processing Time 0.033 seconds

Optimization of HVOF Spray Parameters for $Cr_3C_2 - 7wt%NiCr$ Coating Powder by Experimental Design Method (실험계획법에 의한 $Cr_3C_2 - 7wt%NiCr$ 용사분말의 HVOF 용사변수 최적화)

  • 김병희;서동수
    • Journal of Welding and Joining
    • /
    • v.15 no.1
    • /
    • pp.125-134
    • /
    • 1997
  • This study was conducted by L9 orthogonal array to obtain optimum spray parameters for This study was conducted by L9 orthogonal array to obtain optimum spray parameters for $Cr_3C_2 - 7wt%$(80wt%Ni-20wt%Cr) coating powder. The factors were hydrogen flow rate, oxygen flow rate, gun-to-work distance, powder feed rate. And evaluation methods for the coating were surface roughness, oxygen concentration, micro-hardness, pore size and distribution, low angle ($30^{\circ}$) erosion rate, and microstructure of coating. The optimum HVOF spray conditions were proved as follows : hydroen flow rate ; 681 SLPM, oxygen flow rate ; 215 SLPM $H^2/O^2 ratio= 3.16), gun-to-work distance ; 22cm, powder feed rate; 25g/min. The hardness (Hv300) was 1147 and the erosion rate ($30^{\circ}$degree) was $3.16\times10^{-4}$g/g. It is believed that the optimized spray conditions can be improved the wear-resistance and anti-erosion characteristics of the coating.

  • PDF

Milled Rice Recovery Rate of Paddy with Various Moisture Contents (벼의 함수율에 따른 도정수율의 변화)

  • 하유신;박경규;김혁주;홍동혁;나규동
    • Journal of Biosystems Engineering
    • /
    • v.27 no.2
    • /
    • pp.125-132
    • /
    • 2002
  • In order to investigate the optimum moisture content of paddy for milling process, a series of tests were conducted by examining the recovery rate and whiteness of milled rice in relation with the various moisture content. Hwabong-byeo and Dongjin-byeo varieties which were major paddies cultivated in Korea were used for the experiment. The test was performed with small experimental milling machines. In order to minimize the unexpected factors, environment conditions were kept in constant during the experiment. As a result, the recovery rate of milled rice were varied as the changes in milling time and degree of whiteness. However, the recovery rate of milled rice increases as its moisture content increases untill a certain point of moisture content and decreases slowly afterward. This certain point can be called optimum moisture content for rice milling. Also, it has a different value depending on the variety. In this experiment, optimum moisture content of Hwabong-byeo and Dongjin-byeo were considered around 14.8% and 15.3%, respectively. It is not sure that these optimum moisture contents for the two varieties would assume the same values irrespective of harvest year and place. However, it could be concluded that the optimum moisture content for rice milling is around 15%(w.b.) for Hwabong-byeo and 15.5%(w.b.) for Dongjin-byeo, respectively.

Studies on Computer Optimization Techniques for Hydrophilic Vehicle Compositions

  • Lee, Chi-Ho;Shin, Young-Hee
    • Archives of Pharmacal Research
    • /
    • v.11 no.3
    • /
    • pp.185-196
    • /
    • 1988
  • The inflence of hydrophilic vehicles on percutaneous absorption rate of griseofulvin was studied using intact skin of full thickness of hairless rat. The in vitro absorption rates were used as the characteristics for deciding the optimum formula of ointment vehicles. The optimum formula of vehicle compositions for maximum absorption rate was obtained from the polynomial regression equation and the two graphical techniques, contour graph and partial derivative graph. It was composed of sodium lauryl sulfate (1.65 W /W%), white petrolatum (16.5 W /W%), propylene glycol (12.0 W /W%), and stearyl alcohol (19.6W /W%). The experimental value obtained from the optimum formula and the prediction value were 33.99 and 33.87 ${\mu}g/\sqrt{min}$, respectively. From these results, it was believed that optimum formula for semisolid dosage forms could be obtained from the application of the optimization technique used in this study.

  • PDF

OPTIMZATION OF A PIN FIN BASED ON THE INCREASING RATE OF HEAT LOSS

  • Kang, Hyung-Suk
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.12 no.1
    • /
    • pp.25-32
    • /
    • 2008
  • A pin fin is optimized based on the increasing rate of heat loss by using a two-dimensional analytic method. The optimum heat loss, corresponding optimum thermal resistance and fin length are presented as a function of the fin base thickness, convection characteristic numbers ratio, fin outer radius and ambient convection characteristic number. One of the results shows that both the optimum heat loss and fin length decrease linearly whereas the optimum thermal resistance increases very slightly with increase of the fin base thickness.

  • PDF

Optimum Inner and Outer Code Rates for Concatenated Codes in Gaussian Binary Symmetric Channels (가우시안 이진 대칭 채널에서 쇄상부호의 최적 내.외 부호율에 관한 연구)

  • Lee, Ye Hoon
    • Journal of Satellite, Information and Communications
    • /
    • v.9 no.2
    • /
    • pp.110-113
    • /
    • 2014
  • In this paper, we address a problem of finding the optimum inner and outer code rates for a concatenated code in Gaussian binary symmetric channels. Clearly, as the inner code rate decreases, the error detection capability of the inner code increases. However, decreasing the inner code rate implies a decrease in error-correction capability of the outer code when overall code rate is fixed. With this notion in mind, we examine the optimum distribution of redundancy on the outer and inner codes to achieve a maximum performance gain in the concatenated coding scheme. Our analysis shows that the maximum coding gain can be obtained when the inner code rate is maximized and the outer code rate is minimized under the constraint of total code rate is fixed.

Optimum Feeding Rate in Growing Olive Flounder Paralichthys olivaceus Fed Practical Extruded Pellet at Optimum Water Temperature (21℃) (적수온(21℃)에서 사육한 성장기 넙치 (Paralichthys olivaceus)의 배합사료 적정 공급률)

  • Kim, Sung-Sam;Kim, Kang-Woong;Kim, Kyoung-Duck;Lee, Bong-Joo;Han, Hyon-Sob;Kim, Jae-Won;Bai, Sungchul C.;Lee, Kyeong-Jun
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.26 no.4
    • /
    • pp.789-796
    • /
    • 2014
  • This study was conducted to investigate the effects of feeding rate on growth performance, blood components and histology of growing olive flounder. The experiment was carried out to determine the optimum feeding rate of the fish (initial fish mean weight of $97{\pm}3.0$ g) at the optimum water temperature. Two replicated groups of fish were fed commercial diet at the feeding rates of 0, 1.0, 1.65 and 2.3% body weight (BW)/day and satiation. Feeding trial was conducted under a flow-through system with ten 1.2 metric ton aquaria receiving filtered seawater at $21{\pm}2^{\circ}C$ for three weeks. Weight gain and specific growth rate (SGR) for fish fed to satiation were significantly higher than those for the unfed fish and for fish fed at 1.0 and 1.65% BW/day. There were no significant differences in values of such parameters between fish fed at 1.65% and those fed at 2.3% BW/day and between fish fed at 2.3% and those fed to satiation. Weight gain and SGR for the unfed fish were significantly lower than those for fish in the other treatments. All the tissues (hepatopancreas, kidney and anterior intestine) were in good condition in fish fed the experimental diet at different feeding rates. This result indicates that the optimum feeding rates of olive flounder (97-160 g) was approximately 2.52% BW/day at the optimum water temperature.

Characterization of superplastic material SPF8090 AI-Li with the variation of the strain rate and the temperature (변형률속도와 온도에 따른 SPF8090 Al-Li 초소성 재료의 물성 특성)

  • Lee, Ki-Seok;Huh, Hoon
    • Transactions of Materials Processing
    • /
    • v.6 no.5
    • /
    • pp.425-434
    • /
    • 1997
  • A superplastic material, aluminum-lithium alloy 8090, was examined with uniaxial tensile tests to investigate its thermomechanical behavior. The tests were carried out at the strain rate ranging from $2X10^4 to 1X10^2$ and at the temperature from 48$0^{\circ}C$ to 54$0^{\circ}C$. The experiments produced force-dis-placement curves which were converted to stress-strain curves. From the curves, the optimum conditions of superplastic forming were obtained by deteriming the strain rate sensitivety, the optimum strain rate, and the strength coefficient for various forming temperatures.

  • PDF

An investigation of absorption phenomena in the horizontal staggered tube absorber for various LiBr solution flow rates (LiBr용액량 변화에 따른 수평다관 흡수기의 특성 연구)

  • Kwon, Yul;Yoon, Sang-Guk
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.3
    • /
    • pp.332-338
    • /
    • 1999
  • An experimental study of absorption phenomena of water vapor into LiBr solution was carried out to find out the optimum solution flow rate. The staggered bundle of horizontal absorption tubes, which are the same configuration as the commercial heat pump, were tested. The results showed that the heat transfer and absorption rate were enhanced with the increase of LiBr solution flow rate. Those values for different absorber pressures showed the same qualitative trends. The optimum flow rate of solution was obtained as three times of the designed flow rate.

  • PDF

A Study on Decision of Optimum Installed Reserve Rate using Probabilistic Reliability Criterion (확률론적인 신뢰도기준에 의한 적정설비예비율의 결정에 관한 연구)

  • Park, Jeong-Jae;Choi, Jae-Seok;Yun, Yong-Bum;Jung, Young-Bum
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.8
    • /
    • pp.1318-1326
    • /
    • 2008
  • This paper proposes an alternative methodology for deciding an optimum deterministic reliability level (IRR; Installed Reserve Rate) by using probabilistic reliability criterion (LOLE; Loss of Load Expectation). Additionally, case studies using the proposed method induce the characteristics of relationship between the probabilistic reliability index (LOLE) and deterministic reliability index (IRR) for 2008 and 2010 years in Korea power system. The case study presents a possibility that an optimum IRR level in Korea can be assessed using the proposed method. Korea power system has been using the LOLE criterion to determine the adequacy of installed capacity (ICAP) requirement. The criterion in Korea is that the loss of load expectation shall not exceed the available capacity more than five day in ten years (=0.5[days/year]), The probabilistic reliability evaluation and production cost simulation program which is called PRASim is used in order to evaluate the relationship and optimum IRR in this paper.

Optimum Design of Multi-Stacking Current Lead Using HTS Tapes (고온초전도 테이프를 이용한 적층형 전류 도입선의 최적설계)

  • 설승윤;김민수;나필선
    • Progress in Superconductivity and Cryogenics
    • /
    • v.3 no.1
    • /
    • pp.35-39
    • /
    • 2001
  • The optimum cross-sectional area profile of gas-cooled high-temperature superconductor(HTS) current lead is analyzed to have minimum helium boil-off rate. The conventional constant area HTS lead has much higher helium consumption than the optimum HTS lead considered in this study. The optimum HTS lead has variable cross-sectional area to have constant satiety factor. An analytical formula of optimum shape of lead and temperature profile are obtained. For multi-stacking HTS current leads, the optimum tape lengths and minimum heat dissipation rate are also formulated. The developed formulations are applied to the Bi-2223 material, and the differences between constant area, constant safety-factor, and multi-stacking current leads are discussed.

  • PDF