• Title/Summary/Keyword: Optimal Sensitivity

Search Result 1,234, Processing Time 0.029 seconds

An EMQ Model in An Unreliable Machine (불완전한 생산 시스템에서의 경제적인 생산량 결정)

  • Kim, Chang-Hyun;Hong, Yu-Shin;Kim, Soo-Young
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.20 no.2
    • /
    • pp.3-17
    • /
    • 1994
  • This paper presents an EMQ model which determines an optimal manufacturing lot size in an unreliable machine. The machine has an exponentially distributed life time, and requires a constant time to repair when it fails. We 1) derive an average cost function, 2) obtain an optimal lot size and show that it is unique, 3) carry out sensitivity analysis to examine the effect of machine parameters (life time, time to repair) to optimal lot size.

  • PDF

Die Shape Optimal Design in Bimetal Extrusion by The Finite Element Method (유한요소법에 의한 이중 금속봉 압출 공정의 금형 형상 최적설계)

  • 변상민;황상무
    • Transactions of Materials Processing
    • /
    • v.3 no.3
    • /
    • pp.302-319
    • /
    • 1994
  • A new approach to die shape optimal design in bimetal extrusion of rods is presented. In this approach, the design problem is formulated as a constrained optimization problem incorporated with the finite element model, and optimization of the die shape is conducted on the basis of the design sensitivities. The combinations of the core and sleeve materials.

  • PDF

Optimal Tolerance Design within Limited Costs using Genetic Algorithm (유전 알고리즘을 이용한 한계비용내의 최적 공차 설계)

  • 장현수;이병기;김선호
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.22 no.49
    • /
    • pp.33-41
    • /
    • 1999
  • The original tolerances, which are assigned by designers on the basis of handbooks and experience, cannot always be expected to be optimal or feasible, because they may yield an unacceptable manufacturing costs. So the systematic tolerance design considering manufacturing costs should be done. Therefore, this research analyzes the tolerance within the tolerance design using Monte-Carlo simulation method and sensitivity analysis and using genetic algorithm by tolerance allocation method. The genetic algorithm was developed for allocation of the optimal tolerance under the manufacturing limitation cost.

  • PDF

Optimal Design of Linear Viscous Damping System for Vibration Control of Adjacent Building Structures (인접구조물의 진동제어를 위한 선형감쇠시스템의 최적설계)

  • Park, Kwan-Soon;Ok, Seung-Yong;Koh, Hyun-Moo
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.10 no.3 s.49
    • /
    • pp.85-100
    • /
    • 2006
  • This paper proposes an optimal design method of linear viscous dampers for the seismic performance of two adjacent structures with different heights. Accordingly, connection method using diagonal bracing between two floors and connection method between two structures are considered, and the effectiveness of the latter method is confirmed through the comparison of the frequency response functions with respect to damping capacity. Moreover, optimal damping to minimize the response of the adjacent structures in the frequency domain is found. The sensitivity of natural frequency and modal damping according to the damper capacity at each floor is obtained for the optimally designed system. From the sensitivity analysis, the modal damping is evaluated to be very sensitive to the damper installed at higher floor. Therefore, sensitivity-based damping distribution method is proposed. Diagonal bracing connection method, uniform distribution method and sensitivity-based distribution method are compared to each other in terms of seismic performance. The comparative results demonstrate that the proposed method is an effective seismic design method for the adjacent structures.

Experimental Validation of Topology Design Optimization (밀도법 기반 위상 최적설계의 실험적 검증)

  • Cha, Song-Hyun;Lee, Seung-Wook;Cho, Seonho
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.26 no.4
    • /
    • pp.241-246
    • /
    • 2013
  • From the numerical results of density-based topology design optimization, a CAD geometric model is constructed and fabricated using 3D printer to experimentally validate the optimal design. In the process of topology design optimization, we often experience checkerboard phenomenon and complicated branches, which could result in the manufacturing difficulty of the obtained optimal design. Sensitivity filtering and morphology methods are used to resolve the aforementioned issues. Identical volume fraction is used in both numerical and experimental models for precise validation. Through the experimental comparison of stiffness in various designs including the optimal design, it turns out that the optimal design has the highest stiffness and the experimental result of compliance matches very well with the numerical one.

Joint Decision of Optimal Procurement Policy and Optimal Order ize for a Product Recovery System (회수제품 재가공이 이루어지는 시스템에서 최적 신제품 구매정책과 최적 주문량에 대한 연구)

  • Kim, Eungab;Jeong, Bongju
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.34 no.4
    • /
    • pp.398-407
    • /
    • 2008
  • We consider a product recovery system that a single product is stocked in order to meet a demand from customers who may return products after usage. This paper addresses a problem of when to release a procurement process to replenish serviceable inventory and how many new products to procure. The structure of the optimal procurement policy is examined and numerically identified as a monotonic threshold curve. A numerical procedure is presented to jointly find the optimal procurement order size, optimal procurement policy, and optimal discounted profit. Sensitivity analysis also indicates that these optimal performance measurements have monotonic properties with respect to system parameters.

An Experimental Investigation on the Contamination Sensitivity of an Automotive Fuel Pump

  • Lee Jae-Cheon;Shin Hyun-Myng
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.6 no.3
    • /
    • pp.51-55
    • /
    • 2005
  • This study addresses the contamination sensitivity test of a typical fuel pump for an automotive vehicle. The objective of the study is to find the contamination sensitivity coefficient of a fuel pump on specific contaminant particle sizes so that an optimal fuel filter could be selected. To achieve the objective, the degradation of discharge flow rate of the fuel pump is measured under the experiments of various contaminants size ranges of ISO test dust up to $80\;{\mu}m$. The fundamental theory of contamination sensitivity is introduced and the contamination sensitivity coefficients are estimated using the experimental data. Maximum contamination sensitivity coefficient of $5\chi\;10^{-6}\;L/min{\cdot}Ea$ is found in the contaminant size range of $40\;{\mu}m\~50\;{\mu}m$. The magnified picture of the surface of vane disc reveals that the abrasive wear is the principal cause of discharge flow rate degradation. Hence, this study reveals that a high efficiency filter for contaminant particles especially in the size range of $30\;{\mu}m\~70\;{\mu}m$ especially should be used to maintain the service life of the fuel filter.

An Experimental Investigation on The Contamination Sensitivity of An Automotive Fuel Pump (자동차 연료펌프의 오염민감도 실험 연구)

  • 이재천;장지현;신현명
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.6
    • /
    • pp.102-108
    • /
    • 2004
  • This study addresses the contamination sensitivity test of a typical fuel pump for automotive vehicle. The objective of the study is to find the contamination sensitivity coefficient of fuel pump on specific contaminant particle sizes so that optimal fuel filter could be selected. To achieve the objective, the degradation of discharge flow rate of fuel pump was measured under the experiments of various contaminants size ranges of ISO test dust up to 80${\mu}{\textrm}{m}$. The fundamental theory of contamination sensitivity was introduced and the contamination sensitivity coefficients were estimated using the experimental data. Maximum contamination sensitivity coefficient of $5{\times}10^{-6}$ L/minㆍEa was found on the contaminant size range of 40${\mu}{\textrm}{m}$∼50${\mu}{\textrm}{m}$. The magnified picture of the surface of vane disc revealed that the abrasive wear was the principal cause of discharge flow rate degradation. Hence, this study revealed that high efficiency filter on the contaminant particle size range of 30${\mu}{\textrm}{m}$∼70${\mu}{\textrm}{m}$ especially should be used to maintain the service lift of the fuel filter.

Studies on the Edwardsiellosis of cultured flounder, Paralichthys oliuaceus;- Characteristics, pathgenicity and control of Edwardsiella tarda - (양식넙치(Paralichthys olivaceus)의 복수증에 관한 연구 - Edwardsiella tarde의 일부 특성과 병원성 및 대책 -)

  • 한재철;김영진;서형석;김영길;이근광;안병목
    • Korean Journal of Veterinary Service
    • /
    • v.20 no.1
    • /
    • pp.11-18
    • /
    • 1997
  • Characteristics, pathogenicity and control of the causative organisms isolated front diseased cultured flounder, Paralichthys olivaceus were studied. The causative organisms were identified as E tarda by biochemical and biophysical characteristics. Also, it strains were named as E tarda KBF-1 and E tarda KMF-1, and optimal pH of E tarda KBF-1 and E tarda KMF-1 were 8.0, and optimal concentration of NaCl. E tarda KBF-1 was 0% and E tarda KMF-1 was 1%. In the pathogenicity test, 0~10 of the flounders of artificially infected group(E tarda KBF-1) with $1.0{\times}10^7$ cfu/fish were died within 60 hrs, but 0~9 flounders infected group with 41.0{\times}10^6$ cfu/fish were died within 60 hrs. Also, 0~10 flounders infected group(E tarda KMF-1) with $1.0{\times}10^7$ cfu/fish were died within 36 hrs, while 0~7 flounders infected with $1.0{\times}10^6$ cfu/fish were died within 60 hrs. Drug sensitivity of E tarda KBF-1 strain was resistant to AM, CF and N, and intermediate to E, K and S, and sensitivity to C, G, SxT and FF. But E tarda KMF-1 strain was resistant to CF, E and V, and intermediate to AM, C, N and SxT, and sensitivity to GM and FF.

  • PDF

Comparison of the Pediatric Balance Scale and Fullerton Advanced Balance Scale for Predicting Falls in Children With Cerebral Palsy

  • Kim, Gyoung-mo
    • Physical Therapy Korea
    • /
    • v.23 no.4
    • /
    • pp.63-70
    • /
    • 2016
  • Background: The Pediatric Balance Scale (PBS) and the Fullerton Advanced Balance (FAB) scale were used to assess balance function in patients with balance problem. These multidimensional clinical balance scales provide information about potential risk factors for falls. Objects: The purpose of this study was to investigate and compare the predictive properties of the PBS and FAB scales relative to fall risk in children with cerebral palsy (CP) using a receiver operating characteristic analysis. Methods: In total, 49 children with CP (boy=21, girl=28) who were diagnosed with level 1 or 2 according to the Gross Motor Function Classification System participated in this study. The PBS and FAB were performed, and verified cut-off score, sensitivity, specificity, and the area of under the curve (AUC). Results: In this study, the PBS scale was as a predictive measure of fall risk, but the FAB was not significant in children with CP. A cut-off score of 45.5 points provided optimal sensitivity of .90 and specificity of .69 on the PBS, and a cut-off score of 21.5 points provided optimal sensitivity of .90 and specificity of .62 on the FAB. Both scales showed moderately accurate of AUC with .79 and .76, respectively. Conclusion: The PBS is a useful screening tool for predicting fall risk in children with cerebral palsy, and those who score 45.5 or lower indicate a high risk for falls and are in need of balance intervention.