• Title/Summary/Keyword: Optics Material

Search Result 394, Processing Time 0.024 seconds

A Comparative Study of Ophthalmic Spectacle Lenses Standards (시력보정용 안경렌즈의 규격에 관한 비교 고찰)

  • Yu, Dong-Sik;Moon, Byeong-Yeon;Son, Jeong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.397-415
    • /
    • 2004
  • This study surveyed differences among KS, ISO, JIS and ANSI ophthalmic spectacle lenses standards. These standards applied to several lenses that were in common currency and we checked over problems and improvements in KS. KS corresponded to ISO, for the most part, and ANSI, partly. But terms, definitions, progressive power lenses standards, UV transmittance and base curves clauses did not exist in KS. There was no differences between nominal data and actual data in important clauses estimation-minimum requirements on refractive power, tolerances on the size of lenses, material and surface quality. But tolerances of thickness, base curves, UV and visible transmittance values were not existing, there were differences among several ophthalmic spectacle lenses in the test of these clauses. These requirements will be needed for better and more comfortable vision.

  • PDF

Design and Manufacture of an Off-axis Aluminum Mirror for Visible-light Imaging

  • Zhang, Jizhen;Zhang, Xin;Tan, Shuanglong;Xie, Xiaolin
    • Current Optics and Photonics
    • /
    • v.1 no.4
    • /
    • pp.364-371
    • /
    • 2017
  • Compared to one made of glass, an aluminum mirror features light weight, compact design, low cost, and quick manufacturing. Reflective mirrors and supporting structures can be made from the same material, to improve the athermal performance of the system. With the rapid development of ultraprecise machining technologies, the field of applications for aluminum mirrors has been developed rapidly. However, most of them are rotationally symmetric in shape, and are used for infrared applications. In this paper, the design and manufacture of an off-axis aluminum mirror used for a three-mirror-anastigmat (TMA) optical system at visible wavelengths is presented. An optimized, lightweight design provides a weight reduction of more than 40%, while the surface deformation caused by earth's gravity can meet the required tolerance. The two pieces of an off-axis mirror can be diamond-turned simultaneously in one setup. The centrifugal deformation of the off-axis mirror during single-point diamond turning (SPDT) is simulated through the finite-element method (FEM). The techniques used to overcome centrifugal deformation are thoroughly described in this paper, and the surface error is reduced to about 1% of the original value. After post-polishing, the form error is $1/30{\lambda}$ RMS and the surface roughness is better than 5 nm Ra, which can meet the requirements for visible-light imaging.

Method for the Assembly of a High-density Multi-channel Deformable Mirror for High Energy Lasers (고에너지 레이저용 고밀집 다채널 실리콘-카바이드 변형거울의 정밀 조립 방법)

  • Hyug-Gyo Rhee;Sunho Cho;Sihyun Kim;Jaehyun Lee;Pilseong Kang
    • Korean Journal of Optics and Photonics
    • /
    • v.35 no.4
    • /
    • pp.170-174
    • /
    • 2024
  • A laser beam propagating in free space can be negatively affected by atmospheric turbulence. To overcome this and correct the wavefront error of the laser beam itself, a deformable mirror (DM), which is a key component of adaptive optics, is widely used. In this paper, a novel precision assembling method is suggested for a multi-channel high-density DM. The material of the mirror sheet of the DM is silicon carbide (SiC), and the actuator is a stacked-type lead-magnesium-niobate (Pb(Mg1/3Nb2/3)O3; PMN). To connect the mirror sheet and each actuator, a flexure is inserted. The flexure can make the DM operate with full strokes without the failure of adhesive. A series of jigs were designed and applied in order to assemble these three parts (the mirror sheet, actuators, and flexures) precisely. After assembly, the performance of the DM was also checked.

Characterization of Hydrogel Tinted Contact Lens Containing 4-iodoaniline using Titanium Silicon Oxide Nanoparticles as Additive (티타늄 실리콘 옥사이드 나노입자를 첨가제로 사용한 4-iodoaniline을 포함한 하이드로젤 착색 콘택트렌즈의 특성)

  • Cho, Seon-Ahr;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.3
    • /
    • pp.315-322
    • /
    • 2014
  • Purpose: The physical and optical characteristics of hydrophilic tinted contact lens containing titanium silicon oxide nanoparticles and the basic hydrogel contact lens material containing 4-iodoaniline were examined. In this study, the utility of titanium silicon oxide nanoparticles as a UV-blocking material for ophthalmologic devices were investigated by measuring the UV transmittance of the produced polymer. Also, titanium silicon oxide nanoparticles only without the addition of 4-iodoaniline in primary contact lens materials by copolymerizing two groups were compared. Methods: For manufacturing hydrogel lens, HEMA, MA, MMA, 4-iodoaniline and a cross-linker EGDMA were copolymerized in the presence of AIBN as an initiator. Also, the titanium silicon oxide nanoparticles was used as additive. After polymerization the physical properties such as water content, refractive index, contact angle and spectral transmittance of produced contact lenses were measured. Results: Measurement of the physical properties of the copolymerized material showed that the water content, refractive index, UV-B transmittance and contact angle were in the range of 35.01~38.60%, 1.4350~1.4418, $34.15{\sim}57.25^{\circ}$ and 1.0~10.0%, respectively. Titanium silicon oxide nanoparticles is not used as an additive in the experimental group, the results of the measurement showed that the water content, refractive index, contan angle and UV-B transmittance of the hydrogel lens polymer was 34.00~36.80%, 1.4378~1.4420, $40.15{\sim}60.16^{\circ}$ and 1.8~25.0%, respectively. Conclusions: Also, the transmittance for UV light was reduced significantly in combinations containing titanium oxide nanoparticles.

A Study of the Upper Layer for Improvement of the Extraction Efficiency in LED (LED 광 추출 효율 향상을 위한 상부 층 특성 고찰)

  • Choi, Chul-Hyun;Lee, Dong-Jin;Yim, Hae-Dong;Kim, Bo-Soon;Sung, Jun-Ho;Lee, Min-Woo;O, Beom-Hoan
    • Korean Journal of Optics and Photonics
    • /
    • v.22 no.1
    • /
    • pp.53-57
    • /
    • 2011
  • In this paper, we improved the light extraction efficiency by considering an additional upper layer on the top surface of a conventional LED. We simulated the LED's light emission as functions of the thickness and the refractive index of the upper layer, and analyzed how the condition improved the light efficiency. When the refractive index's range was from 1.05 to 1.40, the LED emission increased. For that case, the emission also increased as the thickness increased. We experimentally showed that the light extraction efficiency was improved about 22% by forming the upper layer on the top surface of an LED using material with refractive index 1.30 at 589.3 nm. It is expected that forming the upper layer on an LED can easily improve the extraction efficiency.

Theory of polarization grating formation induced by the photosensitivity in birefringent optical fibers

  • An, Sunghyuck
    • Korean Journal of Optics and Photonics
    • /
    • v.5 no.4
    • /
    • pp.487-492
    • /
    • 1994
  • The two-photon bleaching model is generalized to derive the dynamical equations which describe the polarization grating formation induced by the photosensitivity in birefringent optical fibers. The frequency response of the induced polarization grating is studied numerically and its relation to the material parameter is investigated.

  • PDF

The Difference of Tear Break-Up Time by the Fitting States of Soft Contact Lens in Normal and Dry Eyes (정상안과 건성안에서 소프트렌즈 피팅 상태에 따른 비침입성 눈물막 파괴 시간의 차이)

  • Jung, Da I;Lee, Heum Sook;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.4
    • /
    • pp.339-346
    • /
    • 2010
  • Purpose: The study was performed to compare the difference of non-invasive tear break-up time (NIBUT) with alignment or steep fitting of soft contact lens in normal and dry eyes. Methods: Total 40 eyes (aged 20~30 years) were classified to the normal (n=20) or dry eye group (n=20) by the diagnosis methods for dry eyes and worn soft contact lens (polymacon material) with alignment or steep fitting. NIBUTs of lens wearers were separately measured at the points of before wearing, immediately after wearing and after stabilization of tear film. Results: With alignment fitting, averaged NIBUT in the dry eye group after stabilization of tear film was not significantly different from that of the normal eye group. However, averaged NIBUTs in the normal and dry eyes had significant difference when measured immediately after lens wearing. However, the number of eyes having NIBUT less than 4.0 second was 30% higher compared to the number of normal eyes with steep fitting when measured immediately after wearing. Some shorten NIBUT in dry eyes with steep fitting was also shown after stabilization of tear film. Conclusions: These results suggest that wearing soft contact lens in dry eyes differently affect tear film compared to normal eyes. Thus, dry eyes need more advertent fitting for contact lens wearing because of unstable tear film.

Study on the Antibiosis and Physical Properties of Copolymer Containing Silver (은을 포함한 공중합체의 항균성 및 물리적 특성에 관한 연구)

  • Ye, Ki-Hun;Cho, Su-Hyeon;Sung, A-Young
    • Journal of the Korean Chemical Society
    • /
    • v.53 no.5
    • /
    • pp.542-546
    • /
    • 2009
  • Recently, silver has been applied to various fields due to antimicrobial property and high conductivity. We manufactured high-performance ophthalmic material containing silver which could protect eye from environmental factors. We mixed $AgNO_3$ with conventional contact lens material. And then we copolymerized at 70 ${^{\circ}C}$ for 40 minutes under water bath, and estimated antimicrobial activity and physical properties. We used solid culture and liquid culture medium for antimicrobial test. The results of contact lens containing silver showed good antibiosis. In case of physical properties, the results showed 32.35%(water content) and 88.34% (visible transmittance) for each. We judged that we made the copolymer with antimicrobial and physical properties which is suitable for conventional contact lens.

Physical Properties of Styrene Copolymer and Contact Lens Application (스타이렌 공중합체의 물리적 특성 및 콘택트 렌즈로의 응용)

  • Kim, Tae-Hun;Ye, Ki-Hun;Sung, A-Young
    • Journal of the Korean Chemical Society
    • /
    • v.53 no.6
    • /
    • pp.755-760
    • /
    • 2009
  • Styrene is broadly used as a polymer and a copolymer and is useful in manufacturing contact lenses due to its high refractive index. This study used styrene with the cross-linker EGDMA (ethylene glycol dimethacrylate), HEMA (2-hydroxyethyl methacrylate) and the initiator AIBN (azobisisobutyronitrile) for copolymerization. Measurement of the physical characteristics of the copolymerized material showed that the refractive index is 1.4412 - 1.4628, water content 20 - 35%, visible transmittance 82.6 - 87% and the tensile strength 0.143 - 0.344 Kgf. Also, measurements showed that the refractive index and tensile strength increased while the water content decreased as the ratio of styrene increased. Based on the results of this study, the produced copolymer can be estimated to be suitable for use as a material for high performance functional contact lenses.