• Title/Summary/Keyword: Optical properly

Search Result 122, Processing Time 0.019 seconds

Precise Determination of the Complex Refractive Index and Thickness of a Very Weakly Absorbing Thin Film on a Semi-transparent Substrate Using Reflection Ellipsometry and Transmittance Analysis (반사 타원법과 투과율 분석법을 사용한 반투명 기층 위 매우 약한 광흡수 박막의 두께와 복소굴절률 정밀 결정)

  • Sang Youl Kim
    • Korean Journal of Optics and Photonics
    • /
    • v.35 no.1
    • /
    • pp.1-8
    • /
    • 2024
  • Explicit expressions for the transmission pseudo-ellipsometric constants and transmittance of a semi-transparent glass substrate coated with thin films are presented to determine the optical constants of a very weakly absorbing thin film coated on a glass substrate. The intensity of the multiply reflected light inside the semi-transparent substrate is superposed incoherently and the light absorption by the substrate is properly treated, so that modeling analysis of thin films coated on a semi-transparent substrate can be performed with increased accuracy. The extinction coefficient derived from transmittance analysis is compared to that from ellipsometric analysis in the weakly absorbing region, and the difference between the two extinction coefficients is discussed in relation to the sensitivities of the transmittance and ellipsometric constants. This transmittance analysis, together with ellipsometric analysis, is applied to a glass substrate coated with a SiN thin film, and it is shown that the thickness and complex refractive index of the SiN thin film can be determined accurately, even though the extinction coefficient is very small.

Development of a Personal Compound Stimulus Device for Skin-care (개인용 피부미용 복합자극기 개발)

  • Lee, Jeon;Kim, Chi-Hyun;Chung, Geum-Hee
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.49 no.1
    • /
    • pp.12-19
    • /
    • 2012
  • Recently, the market of skin-care device has been steadily growing up. In this paper, we tried to develop a personal compound stimulus device more competitive than existing products. As the compound stimulus, biochemical stimulus of herbal extraction fluid, thermal stimulus of plate-shaped carbon fiber heater, and optical stimulus of near infrared LED were selected. By some evaluation tests, the thermal stimulation part and the optical stimulation part were found to be developed properly. Additionally, the efficacy of the mixed stimulus of thermal and optical stimulation was tested in C2C12 mouse myoblast. Through RT-PCR analysis, it was found that, by the developed compound stimulus, the expression of collagen I mRNA and collagen III mRNA increased by 4.9 and 1.3 times respectively.

Fabrication of Micro-Heatsink using Nanotemplate (나노 템플레이트를 이용한 마이크로 히트 싱크)

  • 함은주;손원일;홍재민
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.10 no.1
    • /
    • pp.7-11
    • /
    • 2003
  • The semiconductor chips or electronic components generate heat, which causes malfunction of the parts when it was not cooled properly. Bulky heat sink and cooling fan are used to get rid of the heat. However, with this bulky system, it is hard to integrate the electronics system in a small scale. The cooling efficiency of the system depends on the surface area of the heat sink, thermal conductivity of the material and the method of integration. In order to develop a novel cooling system, a micro-heatsink with a large surface area while retaining small volume was fabricated by electroless deposition of gold/copper inside a Track-etched membrane. The structure of the micro-heatsink was investigated using SEM or optical microscope. It was also found that the micro-heatsink is more efficient than a flat copper plate.

  • PDF

Precise Tracking control of Automated Guided Vehicle System (무인반송 차량시스템의 정밀 추적제어)

  • Shin, Doo-Jin;Huh, Uk-Youl
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.50 no.7
    • /
    • pp.313-317
    • /
    • 2001
  • This paper proposed a fuzzy logic cross coupled controller which can enhance the path tracking performance of optically guided AGV(Automated Guided Vehicle). The AGV follows the guide path, it cannot be avoid the deviation from the path due to the inevitable error and the deviation must be corrected. Optically guided AGV used in industrial area is controlled by On-Off controller generally, the experimental AGV has three optical sensors in front body. In this structure, we could not know the leaving distance accurately and steering angle from the guided line, so AGV could not be controlled properly with conventional controller in the case of increasing or decreasing velocity. If we mount additional sensors the AGV, we could know the leaving distance and steering angle from the guided line and proper error compensating methode can be applied. But because cost of sensors are high, the cost of total system is increasing. So, in this paper, to improve the tracking performance of AGV which has the minimum number of sensors and fuzzy logic cross coupled controller is proposed. Some simulations and experimental results are presented to illustrate the performance of the proposed controller.

  • PDF

Interfacial Evaluation of Flax and Hemp Fibers/Polypropylene Composites Using Micromechanical Test and Acoustic Emission (Micromechanical 시험법과 음향방출을 이용한 Flax 와 Hemp섬유 강화된 Polypropylene 복합재료의 계면 물성 평가)

  • Son, Tran-Quang;Hwang, Byung-Sun;Park, Joung-Man
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2005.04a
    • /
    • pp.42-45
    • /
    • 2005
  • Interfacial evaluation of various combinations of both Flax and Hemp fibers/polypropylene were performed by using micromechanical test and nondestructive acoustic emission (AE). It can be because interfacial adhesion between the natural fiber surface and matrix plays an important role in controlling the overall mechanical properties of polymer composite materials by transferring the stress from the matrix to the fiber. It is necessary to characterize the interphase and the level of adhesion to understand the performance of the composites properly. Microfailure mechanism of single Flax fiber bundles were investigated using the combination of single fiber tensile test and nondestructive acoustic emission. Microfailure modes of the different natural fiber/polypropylene systems were observed using optical microscope and determined indirectly by AE and their FFT analysis.

  • PDF

A CCD Camera Lens Degradation Caused by High Dose-Rate Gamma Irradiation (고 선량율 감마선 조사에 따른 렌즈의 열화)

  • Cho, Jai-Wan;Lee, Joon-Koo;Hur, Seop;Koo, In-Soo;Hong, Seok-Boong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.7
    • /
    • pp.1450-1455
    • /
    • 2009
  • Assumed that an IPTV camera system is to be used as an ad-hoc sensor for the surveillance and diagnostics of safety-critical equipments installed in the in-containment building of the nuclear power plant, an major problem is the presence of high dose-rate gamma irradiation fields inside the one. In order to uses an IPTV camera in such intense gamma radiation environment of the in-containment building, the radiation-weakened devices including a CCD imaging sensor, FPGA, ASIC and microprocessors are to be properly shielded from high dose-rate gamma radiation using the high-density material, lead or tungsten. But the passive elements such as mirror, lens and window, which are placed in the optical path of the CCD imaging sensor, are exposed to a high dose-rate gamma ray source directly. So, the gamma-ray irradiation characteristics of the passive elements, is needed to test. A CCD camera lens, made of glass material, have been gamma irradiated at the dose rate of 4.2 kGy/h during an hour up to a total dose of 4 kGy. The radiation induced color-center in the glass lens is observed. The degradation performance of the gamma irradiated lens is explained using an color component analysis.

A Study on the Unification of the Grounding System of SeoulMetro (서울메트로 접지설비 표준화 방안 연구)

  • Kim, Gyun-Sig;Park, Han-Yeong;Back, Yu-Ho
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1027-1036
    • /
    • 2007
  • Since the opening of the Seoul Metro in 1974, the electric railway passengers have been increased rapidly and as the advanced equipments(OC,PSD) were introduced, additional power facilities were built in a limited area for the comfortable transportation environment. Present grounding system were built according to old Electric equipment standards and all the electric signal, communication and electronic equipments were built only for the purposes of protecting building structure, people and electronic equipments. Grounding system which was additionally built in the limited area caused problems with the building structure and it caused secondary damages when earth fault happens. One of the problems is grounding system of the building structure; grounding system does not work properly since grounding equipments are not separated from each other. So, existing grounding system needs to be improved and unified grounding system in the building should be established. The purposed of this study is to analyze all the grounding systems that had been built in different year and to establish unified grounding system of Seoul Metro.

  • PDF

Effects of hydration structure on the femtosecond white light-induced phase transition to crystalline silicon nanocrystal having ultrabright narrowed luminescence

  • Choi, Kyong-Hoon;Wang, Kang-Kyun;Ha, Jeong-Hyon;Kim, Yong-Rok
    • Rapid Communication in Photoscience
    • /
    • v.4 no.3
    • /
    • pp.54-58
    • /
    • 2015
  • Under the condition of femtosecond impulsive nonlinear optical irradiation, the bright and narrowed blue emission of silicon nanocrystal was observed. This synthetic method produced very small (~ 4 nm) oxide-capped silicon nanocrystal having probably ultra small emitting core (~ 1 nm) inferred from luminescence. By controlling the stirring condition, very high efficiencies of luminescence ( 4 fold higher) were obtained compared with the other conventional femtosecond laser fragmentation methods, which was attributed to the differences in hydration shell structure during the femtosecond laser induced irreversible phase transition reaction. When we properly adjusted the irradiation times of the white light continuum and stirring condition, very homogeneous luminescent silicon nanocrystal bands having relatively sharp lineshape were obtained, which can be attributable to the luminescent core site isolated and free from the surface defects.

Development of Heliostat Field Operational Algorithm for 200kW Tower Type Solar Thermal Power Plant (200kW 타워형 태양열발전시스템의 헬리오스타트 필드 운영 알고리즘 개발)

  • Park, Young Chil
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.5
    • /
    • pp.33-41
    • /
    • 2014
  • Heliostat field in a tower type solar thermal power plant is the sun tracking mirror system which affects the overall efficiency of solar thermal power plant most significantly while consumes a large amount of energy to operate it. Thus optimal operation of it is very crucial for maximizing the energy collection and, at the same time, for minimizing the operating cost. Heliostat field operational algorithm is the logics to control the heliostat field efficiently so as to optimize the heliostat field optical efficiency and to protect the system from damage as well as to reduce the energy consumption required to operate the field. This work presents the heliostat field operational algorithm developed for the heliostat field of 200kW solar thermal power plant built in Daegu, Korea. We first review the structure of heliostat field control system proposed in the previous work to provide the conceptual framework of how the algorithm developed in this work could be implemented. Then the methodologies to operate the heliostat field properly and efficiently, by defining and explaining the various operation modes, are discussed. A simulation, showing the heat flux distribution collected by the heliostat field at the receiver, is used to show the usefulness of proposed heliostat field operational algorithm.

Analysis of the Spectro-ellipsometric Data with Backside Reflection from Semi-transparent Substrate by Using a Rotating Polarizer Ellipsometer (반투명 기층에 의한 후면반사를 고려한 회전검광자 방식의 타원측정 및 분석)

  • Seo, Yeong-Jin;Park, Sang-Uk;Yang, Seong-Mo;Kim, Sang-Youl
    • Korean Journal of Optics and Photonics
    • /
    • v.22 no.4
    • /
    • pp.170-178
    • /
    • 2011
  • The spectroscopic ellipsometric constants are analyzed to determine the thickness and the complex refractive index of a film coated on a semi-transparent substrate, with the reflection from the backside of the substrate properly considered. Expressions representing the effect of the backside reflection on ellipsometric constants are derived using the thickness and the complex refractive index of the substrate. The thickness and the complex refractive of an ITO thin film coated on a glass substrate are obtained by using this method. The results agree quite well with the ones obtained by following the conventional modeling procedure where the backside reflection is neglected during ellipsometric measurement and analysis.