• 제목/요약/키워드: Optical path

검색결과 491건 처리시간 0.037초

옵티컬 플로우를 이용한 로봇축구의 볼 위치 및 경로 설정 (The ball position and Path Plain for the robot-soccer using Optical flow)

  • 양광현;정헌;최한수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 G
    • /
    • pp.3004-3006
    • /
    • 1999
  • In this paper, we present the ball position and path plain method for the robot-soccer using optical flow. As we compare a optical flow method with a general method within the accurate and effective ball position information of robot-soccer or the path planning, we prove accurate and effective optical flow algorithm to apply ball position and path plain for robot-soccer

  • PDF

LDL Cholesterol Testing Device using Serial Reflected Face-to-Face Mirror System

  • Choi, Min-Seong;Yoo, Jae-Chern
    • Journal of the Optical Society of Korea
    • /
    • 제17권4호
    • /
    • pp.296-299
    • /
    • 2013
  • A low density lipoprotein (LDL) cholesterol testing device, structured with serial reflected face-to-face mirror (SRM) allowing spectrophotometry measurements, is presented. The spectrophotometry has been employed to measure the amount of light that a sample absorbs, but it generally should have had path length longer than 10 mm to secure enough sensitivity. Such requirement of path length has often been problematic in implementing a thin type of lab on a disc (LOD). We developed the SRM system which was implemented in a detection chamber with 1.4mm thickness, providing path length longer than 10mm, and thus straightforwardly being applicable to LOD as thin as a compact disc. The experimental results show that the SRM system gives not only a much thinner design compared to the conventional spectrophotometry-based LOD but also a comparable performance to already commercialized spectrometers.

Common-path Optical Interferometry for Stabilized Dynamic Contrast Imaging: A Feasibility Study

  • Seung-Jin, Lee;Young-Wan, Choi;Woo June, Choi
    • Current Optics and Photonics
    • /
    • 제7권1호
    • /
    • pp.65-72
    • /
    • 2023
  • The motion of organelles inside a cell is an important intrinsic indicator for assessing cell physiology and tissue viability. Dynamic contrast full-field optical coherence tomography (D-FFOCT) is a promising imaging technology that can visualize intracellular movements using the variance of temporal interference signals caused by biological motions. However, double-path interferometry in D-FFOCT can be highly vulnerable to surrounding noise, which may cause turbulence in the interference signals, contaminating the sample dynamics. Therefore, we propose a method for stabilized D-FFOCT imaging in noisy environments by using common-path interferometry in D-FFOCT. A comparative study shows that D-FFOCT with the proposed method achieves stable dynamic contrast imaging of a scattering phantom in motion that is over tenfold more noise-insensitive compared to the conventional one, and thus this imaging capability can provide cleaner motion contrast images. With the proposed approach, the intracellular dynamics of biological samples are imaged and monitored.

Common-path Optical Coherence Tomography for Biomedical Imaging and Sensing

  • Kang, Jin-U.;Han, Jae-Ho;Liu, Xuan;Zhang, Kang
    • Journal of the Optical Society of Korea
    • /
    • 제14권1호
    • /
    • pp.1-13
    • /
    • 2010
  • This paper describes a development of a fiber optic common-path optical coherence tomography (OCT) based imaging and guided system that possess ability to reliably identify optically transparent targets that are on the micron scale; ability to maintain a precise and safe position from the target; ability to provide spectroscopic imaging; ability to imaging biological target in 3-D. The system is based on a high resolution fiber optic Common-Path OCT (CP-OCT) that can be integrated into various mini-probes and tools. The system is capable of obtaining >70K A-scan per second with a resolution better than $3\;{\mu}m$. We have demonstrated that the system is capable of one-dimensional real-time depth tracking, tool motion limiting and motion compensation, oxygen-saturation level imaging, and high resolution 3-D images for various biomedical applications.

광섬유 레이저에서의 광궤환에 대한 연구 (Study on Optical Feedback in Optical Fiber Laser)

  • 최규남
    • 한국정보통신학회논문지
    • /
    • 제11권5호
    • /
    • pp.985-990
    • /
    • 2007
  • 코히런트 광섬유 센서의 해상도를 향상시키기 위하여 광원의 코히런스 길이를 향상시키는 방법에 대하여 연구하였다. 넓은 파장범위에 걸쳐서 레이저 광을 생성할 수 있고 발광 파장대역이 장거리 전송이 가능한 통신용 광섬유의 저 손실 대역인 광섬유 레이저의 코히런스 길이를 향상시키기 위하여 레이저의 광궤환 기법을 이용하였다. 본 논문에서는 광섬유 레이저의 단거리 및 장거리 광궤환 루프가 코히런스 길이에 미치는 영향을 Mach-Zehnder Interferometer를 이용하여 연구하였다. 광궤환 전력량과 광궤환 루프에서의 변조형태가 코히런스에 미치는 영향을 조사하였다. 주파수 천이도는 200m 길이차를 갖는 비대칭 간섭계에서의 위상간섭 정도를 측정하여 계산하였다. 광섬유 레이저에서 단거리 광궤환 루프는 450kHz/sec로 주파수 천이도를 축소시키는데 효과가 있었고 장거리 광궤환 루프는 50kHz/sec로 주파수 천이도를 더 향상시키는 효과가 있음을 알 수 있었다. 실제 코히런트 광센서에 응용 시 고감도 침입자 감지가 기대된다.

Wavelength Shar ing Optimization for Integrated Optical Path and Optical Packet Switch

  • Nguyen, Khanh-Huy;Bui, Dang-Quang;Hwang, Min-Tae;Choi, Myeong-Gil;Hwang, Won-Joo
    • 한국멀티미디어학회논문지
    • /
    • 제13권12호
    • /
    • pp.1805-1813
    • /
    • 2010
  • In this paper, we address the issue of how to improve performance of integrated optical path and optical packet. For supporting ultra-high-speed traffic, integration of optical paths and packets in a switch is one of key techniques in New Generation Networks. However, the wavelength allocation for optical packets and optical paths has not been efficiently resolved yet because there lacks of a systematic model for evaluating performance of the integrated switch. This paper models the operation of the integrated switch as a system of two servers, one for optical paths and the other for optical packets. From the model, we utilize Newton method to find an optimal policy for sharing of wavelength resources. Afterwards, we propose an algorithm to dynamically allocate wavelength resources in an integrated switch. Finally, we evaluate performance of that algorithm.

주야 관측경용 빔 분리프리즘을 위한 1× Optical Path Relay Adapter 설계 (Design of 1× Optical Path Relay Adapter for Beam Splitting Prism used in Day & Night Scope)

  • 이동희;최규정;정인;박승환
    • 한국안광학회지
    • /
    • 제17권4호
    • /
    • pp.441-447
    • /
    • 2012
  • 목적: 본 연구는 주야 관측경에 사용되는 빔 분리프리즘용 $1{\times}$ 광로 연장 어댑터(optical path relay adapter) 설계 개발에 관한 것이다. 방법: 상용 C-mount 경통구조를 가지는 줌렌즈 광학계와 빔 분리프리즘을 사용하여 주간 야간용 관측경을 만들기 위해서는 줌렌즈 광학계의 상의 크기는 변하지 않으면서 결상면의 위치를 길게 늘일 수 있는 광로 연장 어댑터가 필요하다. 이에 우리는 lens module 모드를 사용할 수 있는 CodeV 프로그램을 이용하여 $1{\times}$ 광로 연장 어댑터를 설계할 수 있었다. 결과: 우리는 빔 분리 프리즘을 갖는 주야 관측경용 광로 연장 어댑터를 설계 할 수 있었는데, 이 광학계는 EFL이 -Q56.0 mm, 배율이 +1.0배, 첫 번째 렌즈에서 마지막 렌즈까지의 거리가 약 20.4 mm인 특징을 갖는 광학계가 되었다. 이 시스템의 분해능은 40% MTF 값 기준으로 30 lp/mm인 특성을 보여준다. 이 특성은 설계되어진 광로 연장 어댑터는 3세대 영상증폭관(IIT: image intesifier tubes)의 분해능을 충분히 수용할 수 있는 광학계임을 보여준다. 결론: 30 lp/mm에서 MTF 40%인 성능을 가지면서, 첫 번째 렌즈에서 마지막 렌즈까지의 거리가 20.4 mm, EFL이 -Q56.0 mm, 배율이+1.0인 광학적 특성을 갖는 광로 연장 어댑터를 설계하여 적용함으로써 우리는 상용 C-mount 결상 경통구조를 가지는 줌렌즈 광학계와 3세대 영상증폭관(IIT)과 빔 분리프리즘으로 이루어진 새로운 형태의 주야 관측경을 개발할 수 있었다.

광 마이크로폰 개발을 위한 광 경로해석 및 실험 (Optical Path Analysis and Experiments for Optical Microphone)

  • 권휴상;김경우;김진기;제우성
    • 제어로봇시스템학회논문지
    • /
    • 제13권3호
    • /
    • pp.210-217
    • /
    • 2007
  • The theoretical formulations are derived for calculating optical power change for intensity modulated fiber optical microphone. The optical power change is due to optical paths, misalignment and geometry of optical coupler. Based on the theoretical equations, three different optical couplers are simulated with respect to several angles of optical couplers. In order to evaluate the formulation, a multi-mode to multi-mode coupler which is one of abovementioned optical couplers is designed and characterized by carving out both static experiments and dynamic experiments. Considering experimental results, this paper conclude that the theoretical formulations is very useful for design optical coupler and this kind of fiber optic sensor is adequate to microphone.

살아있는 세포 영상획득을 위한 common-path phase microscopy (Common-path phase microscopy for lives cell imaging)

  • 이지용;이승락;;김덕영
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2008년도 하계학술발표회 논문집
    • /
    • pp.273-274
    • /
    • 2008
  • We present a quantitative phase microscopy for live cells. This method uses the principles of common path inteferometry and single shot phase image. This system has the ability to measure live cells quantitatively with subnanometer path length stability and millisecond scale aquisition time.

  • PDF

An Optical Cavity Design for an Infrared Gas Detector Using an Off-axis Parabolic Mirror

  • Jeong, You-Jin;Kang, Dong-Hwa;Seo, Jae-Yeong;Jo, Ye-Ji;Seo, Jin-Hee;Choi, Hwan-Young;Jung, Mee-Suk
    • Current Optics and Photonics
    • /
    • 제3권5호
    • /
    • pp.374-381
    • /
    • 2019
  • This study examined a method for designing the optical cavity of a non-dispersive infrared gas detector. The infrared gas detector requires an optical cavity design to lengthen the ray path. However, the optical cavity with multiple reflecting surfaces has off-axis aberration due to the characteristics of the reflecting optical system. The rays were parallelized by using the off-axis parabolic mirror to easily increase the ray path and eliminate off-axis aberration so that the rays are admitted to the effective area of the infrared detector uniformly. A prototype of an infrared gas detector was produced with the designed optical cavity to confirm the performance.