• 제목/요약/키워드: Optical monitoring system

검색결과 458건 처리시간 0.025초

AE신호를 이용한 micro-grooving의 상태감시 (State Monitoring of Micro-Grooving using AE Signal)

  • 이희석;손성민;김성렬;안중환
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 추계학술대회 논문집
    • /
    • pp.332-335
    • /
    • 1997
  • With the advance of precision technique, the optical system is more precise and complex and the machining method of optical element which is composed of micro-grooves is developed. Especially, the method of micro-grooving using diamond tool is used widely owing to many merit, but has problems of damage of surface roughness due to tool wear and tool fracture. This paper deals with state monitoring using AE RMS in the micro-grooving. The change of AE RMS is very small with increment of cutting velocity and depth of cut. In spite of constance magnitude of principal force in machining using diamond tool of tool wear and tool fracture, AE RMS is highly fluctuated. Because changing of cutting state has relevance to surface roughness profile, surface toughness profile is expected using AE RMS.

  • PDF

구조물 안전 모니터링용 파장 스위핑 레이저를 위한 스위핑 자동 선형화 (Sweeping Automatic Linearization for Wavelength Swept Laser Used in Structure Safety Monitoring)

  • 이덕규;엄진섭
    • 센서학회지
    • /
    • 제29권1호
    • /
    • pp.51-58
    • /
    • 2020
  • In this study, a novel method for sweeping automatic linearization of wavelength swept laser is proposed. Through the test performed on the implemented laser, the linear sweeping is held up well with a 97% decrease in nonlinearity, and 60 nm sweeping range, 1 kHz sweeping frequency, and 8.8 mW average optical power were obtained. The proposed method uses fiber Bragg grating array, optical-electronic conversion circuit, FPGA embedded module, and a LabVIEW program to generate new compensated wave patterns which were applied to the fiber Fabry-Perot tunable filter. Linear sweeping can reduce the cumbersome and time-consuming recalibration process required for nonlinear sweeping. Additionally, the proposed method provides more accurate measurement results for the structure safety monitoring system.

광추적기와 내부 비전센서를 이용한 수술도구의 3차원 자세 및 위치 추적 시스템 (3D Orientation and Position Tracking System of Surgical Instrument with Optical Tracker and Internal Vision Sensor)

  • 조영진;오현민;김민영
    • 제어로봇시스템학회논문지
    • /
    • 제22권8호
    • /
    • pp.579-584
    • /
    • 2016
  • When surgical instruments are tracked in an image-guided surgical navigation system, a stereo vision system with high accuracy is generally used, which is called optical tracker. However, this optical tracker has the disadvantage that a line-of-sight between the tracker and surgical instrument must be maintained. Therefore, to complement the disadvantage of optical tracking systems, an internal vision sensor is attached to a surgical instrument in this paper. Monitoring the target marker pattern attached on patient with this vision sensor, this surgical instrument is possible to be tracked even when the line-of-sight of the optical tracker is occluded. To verify the system's effectiveness, a series of basic experiments is carried out. Lastly, an integration experiment is conducted. The experimental results show that rotational error is bounded to max $1.32^{\circ}$ and mean $0.35^{\circ}$, and translation error is in max 1.72mm and mean 0.58mm. Finally, it is confirmed that the proposed tool tracking method using an internal vision sensor is useful and effective to overcome the occlusion problem of the optical tracker.

Noninvasive Hematocrit Monitoring Based on Parameter-optimization of a LED Finger Probe

  • Yoon, Gil-Won;Jeon, Kye-Jin
    • Journal of the Optical Society of Korea
    • /
    • 제9권3호
    • /
    • pp.107-110
    • /
    • 2005
  • An optical method of measuring hematocrit noninvasively is presented. An LED Light with multiple wavelengths was irradiated on fingernail and transmitted light from the finger was measured to predict hematocrit. A finger probe contained an LED array and detector. Our previous experience showed that prediction accuracy was sensitive to reliability of the finger probe hardware and we optimized the finger probe parameters such as the internal color, detector area and the emission area of a light source based on Design of Experiment. Using the optimized finger probe, we developed a hematocrit monitoring system and tested with 549 persons. For the calibration model with 368 persons, a regression coefficient of 0.74 and a standard deviation of 3.67 and the mean percent error of $8\%$ were obtained. Hematocrits for 181 persons were predicted. We achieved a mean percent error of $8.2\%$ where the regression coefficient was 0.68 and the standard deviation was 3.69.

실시간 마모량 측정을 통한 대형 기계윤활시스템의 파손발생 진단사례 (A case study on the failure diagnosis of plant machinery system by implementing on-line wear monitoring)

  • 윤의성;장래혁;공호성;한흥구;권오관;송재수;김재덕;엄형섭
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1998년도 제27회 춘계학술대회
    • /
    • pp.321-327
    • /
    • 1998
  • This paper presented a case study on the application of on-line wear monitoring technique to a high duty air-turbo-compressor system. Main objects monitored were a gear unit and metal bearings, both shown frequent troubles due to the severe operation conditions at heavy dynamic load. The air-turbo-compressor system needs secure condition monitoring because it is one of the main utilities in steel making industry. Temperature and vibration characteristics have been mainly on-line monitored in this system for a predictive maintenance; however, it has been shown that they are not fairly good enough to give an early warning prior to the machine failure. In this work, an on-line Opto Magnetic Detector(OMD) was implemented for an on-line wear monitoring, which quantitatively measured the contamination level of both ferrous and non-ferrous wear particles by detecting the change in optical density of used oil. Results showed that the application of on-line OMD system was satisfactory in diagnosis of the machine system.

  • PDF

분포형 광섬유 음향 센서 기반 HVDC 해저케이블 모니터링 기술 연구 (A Study on HVDC Underwater Cable Monitoring Technology Based on Distributed Fiber Optic Acoustic Sensors )

  • 최영국;정효영;김희운;김명진;강희운;김영호
    • 센서학회지
    • /
    • 제32권3호
    • /
    • pp.199-206
    • /
    • 2023
  • This study presents a novel monitoring technique for underwater high-voltage direct current (HVDC) cables based on the Distributed Acoustic Sensor (DAS). The proposed technique utilizes vibration and acoustic signals generated on HVDC cables to monitor their condition and detect events such as earthquakes, shipments, tidal currents, and construction activities. To implement the monitoring system, a DAS based on phase-sensitive optical time-domain reflectometry (Φ-OTDR) system was designed, fabricated, and validated for performance. For the HVDC cable monitoring experiments, a testbed was constructed on land, mimicking the cable burial method and protective equipment used underwater. Defined various scenarios that could cause cable damage and conducted experiments accordingly. The developed DAS system achieved a maximum measurement distance of 50 km, a distance measurement interval of 2 m, and a measurement repetition rate of 1 kHz. Extensive experiments conducted on HVDC cables and protective facilities demonstrated the practical potential of the DAS system for monitoring underwater and underground areas.

초고압 지중선로 감시시스템 연구 (Surveillance System For Underground Power Transmission Lines)

  • 한기만;이광철;김충식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 B
    • /
    • pp.618-620
    • /
    • 1993
  • This system using optical fiber provides various information about underground tunnel and power transmission lines-atmospheric temperature, humidity, oil pressure, flammable gas, cable behavior, and so on. To transmit various data and to keep reliability, optical MUXs are adopted. User can easily operate monitoring software by using GUI.

  • PDF

구조물의 정적 및 동적 거동 모니터링을 위한 광섬유 기반 하이브리드 신경망 계측 시스템 (Optical Fiber-Based Hybrid Nerve Measurement System for Static and Dynamic Behavior of Structures)

  • 박영수;송광용;진승섭;박영환;김성태
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제24권2호
    • /
    • pp.33-40
    • /
    • 2020
  • 광섬유를 이용한 구조물 건전도 모니터링은 다양한 연구가 이루어졌다. 광섬유는 다중 및 분포로 변형률을 계측 할 수 있다. 광섬유 센서 중, FBG 센서는 동적 응답 계측과 정밀도가 높은 장점이 있지만, 계측 포인트의 제한이 있다. 분포형 광섬유 센서는 계측 포인트가 1000개가 넘지만, 샘플링 속도가 낮아 동적 계측이 불가능하다. 본 연구에서는 FBG와 브릴루안 상관영역 측정법의 장점만을 이용한 하이브리드 신경망 센서 계측 시스템이 제안하였다. 광섬유 브래그 격자를 포함한 광섬유를 이용하여 정적응답과 동적 응답을 선택적으로 계측 할 수 있는 계측 시스템이다. 제안된 시스템검증을 위하여 실내 실험을 수행하였으며, 기존의 센서와의 비교를 통해 정확도와 재현성을 검증하였다. 제안된 시스템을 활용하여, 동적 응답을 상시 계측하고, 전역적인 구조물의 상태를 평가한다. 이상 상태가 감지 되면, 분포형 계측 시스템을 이용하여 정적 응답을 계측하여, 구조물의 국부적인 상태를 평가한다. 제안된 시스템을 통해 효율적인 구조물 건전도 모니터링에 활용될 수 있을 것으로 판단된다.

광섬유 센서의 보링 바 삽입에 의한 진동측정 (The Vibration Measurement of Boring Process by Using the Optical Fiber Sensor at inside of Boring Bar)

  • 송두상;홍준희;곽양양
    • 한국정밀공학회지
    • /
    • 제28권6호
    • /
    • pp.709-715
    • /
    • 2011
  • Chattering in cutting operations are usually a cumbersome part of the manufacturing process in mechanical. Particular, machining performance such as that of the boring process is limited by cutting condition at the movable components. Among various sources of chatter vibration, detrimental point in cutting condition is found a mechanical condition on overhang. It limits cutting speed, depth, surface roughness and tool wear failure as result because the all properties are varying with the metal removal process. In this case, we have to observe the resonance frequencies of a boring bar for continuous cutting. In the established research, boring bar vibration of cutting system has been measured with the aid of accelerometer. However, the inherent parameters of internal turning operations are severely limit for the real time monitoring on accelerometers. At this point, this paper is proposed other method for real time monitoring during continuous cutting with optical fiber at the inside of boring bar. This method has been used a plastic fiber in the special jig on boring bar by based on experimental modal analysis. In this study, improvement of monitoring system on continuous internal cutting was attempted using optical fiber sensor of inside type because usually chattering is investigated experimentally measuring the variation in chip thickness. It is demonstrated that the optical fiber sensor is possibility to measure of chattering with real time in boring process.