• Title/Summary/Keyword: Optical injection

Search Result 525, Processing Time 0.028 seconds

Effect on the Electrical Characteristics of OLEDs Depending on Amorphous Fluoropolymer (유기발광다이오드의 전기적 특성에 미치는 Teflon-AF의 영향)

  • Shim, Sang-Min;Han, Hyun-Suk;Kang, Yong-Gil;Kim, Weon-Jong;Hong, Jin-Woong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.9
    • /
    • pp.750-754
    • /
    • 2011
  • In this research, the electric characteristic of organic light-emitting diodes(OLEDs) was studied depending on thickness of amorphous fluoropolymer(Teflon-AF) which is the material of hole injection layer to improve electric characteristic of OLEDs. Sample composition was fabricated in double layer. The basic structure was fabricated by ITO/tris(8-hydroxyquinoline) aluminum (Alq3)/Al and the 2 layer was fabricated by ITO/2,2-Bistrifluoromethyl-4,5-Difluoro-1,3-Dioxole(Teflon-AF)/tris(8-hydro xyquinoline) aluminum (Alq3)/Al. The experiment was carried with variation of thickness of Teflon-AF at 1.0, 2.0, 2.5, 3.0 nm. The result showed when Teflon-AF thickness was 2.5 nm, the electric and optical characteristic were well performed. Moreover, when it was compared with Teflon-AF without materials, it was improved 15.1 times more on luminance, 12.7 times more on luminous efficiency and 12.1 times more on external quantum efficiency. Therefore, OLEDs element with optimum hole injection layer reduced energy barrier and driving voltage, and confirmed that it improved efficiency widely.

Improved Current Source Design to Measure Induced Magnetic Flux Density Distributions in MREIT

  • Oh Tong-In;Cho Young;Hwang Yeon-Kyung;Oh Suk-Hoon;Woo Eung-Je;Lee Soo-Yeol
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.1
    • /
    • pp.30-37
    • /
    • 2006
  • Injecting currents into an electrically conducting subject, we may measure the induced magnetic flux density distributions using an MRI scanner. The measured data are utilized to reconstruct cross-sectional images of internal conductivity and current density distributions in Magnetic Resonance Electrical Impedance Tomography (MREIT). Injection currents are usually provided in a form of mono-polar or bi-polar pulses synchronized with an MR pulse sequence. Given an MRI scanner performing the MR phase imaging to extract the induced magnetic flux density data, the current source becomes one of the key parts determining the signal-to-noise ratio (SNR) of the measured data. Since this SNR is crucial in determining the quality of reconstructed MREIT images, special care must be given in the design and implementation of the current source. This paper describes a current source design for MREIT with features including interleaved current injection, arbitrary current waveform, electrode switching to discharge any stored charge from previous current injections, optical isolation from an MR spectrometer and PC, precise current injection timing control synchronized with any MR pulse sequence, and versatile PC control program. The performance of the current source was verified using a 3T MRI scanner and saline phantoms.

Hydrogen sulfide protects from acute kidney injury via attenuating inflammation activated by necroptosis in dogs

  • Wang, Shuang;Liu, XingYao;Liu, Yun
    • Journal of Veterinary Science
    • /
    • v.23 no.5
    • /
    • pp.72.1-72.14
    • /
    • 2022
  • Background: The treatment of acute kidney injury (AKI), a common disease in dogs, is limited. Therefore, an effective method to prevent AKI in veterinary clinics is particularly crucial. Objectives: Hydrogen sulfide (H2S) is the third gaseous signal molecule involved in various physiological functions of the body. The present study investigated the effect of H2S on cisplatin-induced AKI and the involved mechanisms in dogs. Methods: Cisplatin-injected dogs developed AKI symptoms as indicated by renal dysfunction and pathological changes. In the H2S-treated group, 50 mM sodium hydrosulfide (NaHS) solution was injected at 1 mg/kg/h for 30 min before cisplatin injection. After 72 h, tissue and blood samples were collected immediately. We performed biochemical tests, optical microscopy studies, analysis with test kits, quantitative reverse-transcription polymerase chain reaction, and western blot analysis. Results: The study results demonstrated that cisplatin injection increased necroptosis and regulated the corresponding protein expression of receptor interacting protein kinase (RIPK) 1, RIPK3, and poly ADP-ribose polymerase 1; furthermore, it activated the expressions of inflammatory factors, including tumor necrosis factor-alpha, nuclear factor kappa B, and interleukin-1β, in canine kidney tissues. Moreover, cisplatin triggered oxidative stress and affected energy metabolism. Conversely, an injection of NaHS solution considerably reduced the aforementioned changes. Conclusions: In conclusion, H2S protects the kidney from cisplatin-induced AKI through the mitigation of necroptosis and inflammation. These findings provide new and valuable clues for the treatment of canine AKI and are of great significance for AKI prevention in veterinary clinics.

Preparation and Characterization of Cy5.5-conjugated Biocompatible Polymeric Micellar Nanoparticles for Optical Imaging (광학 영상을 위한 Cy5.5가 결합된 생체적합성 고분자 마이셀 나노입자의 제조 및 특성분석)

  • Kim, Hyo-Jeong;Kim, Byung-Jin;Lee, Ha-Yeong;Jung, Suk Hyun;Jeong, Seo-Young;Yuk, Soon-Hong;Shin, Byung-Cheo;Seong, Ha-Soo;Choi, Youn-Woong;Ha, Dae-Chul;Choi, Sun-Hang;Lee, Soo-Min
    • Journal of Pharmaceutical Investigation
    • /
    • v.39 no.6
    • /
    • pp.393-400
    • /
    • 2009
  • PHEA (hydroxyethyl-aspartamide)-mPEG (methoy-polyethyleneglycol)-$C_{16}$ (hexadecylamine)-ED (ethylenediamine) was prepared as a drug delivery carrier. The structure and molecular weight of polymers were characterized by $^1H$-NMR and gel permeation chromatography. Micelle size and shape were measured by electro-photometer light scattering and transmission electron microscope. The mean diameter of micelles was 23 nm in aqueous solution. To evaluate the potential of these polymeric micelles as a drug carrier, PSI-mPEG-$C_{16}$-ED was conjugated with Cy5.5 for Near-Infrared Fluorescent (NIRF) based optical imaging. PSI-mPEG-$C_{16}$-ED-Cy5.5 was injected intravenously into mice (n=5) and in vivo NIRF imaging was performed during 48 h after injection. The biodistribution study at 24 h after injection showed the longcirculation property of PSI-mPEG-$C_{16}$-ED-Cy5.5. Therefore, PSI-mPEG-$C_{16}$-ED micelles could be a promising drug carrier and imaging agent.

Study on the gate cutting of light guiding plate for mobile using quenching element (박형 도광판의 음각, 양각 마이크로 패턴 성형성에 관한 연구)

  • Hwang, Chul-Jin;Kim, Jong-Sun;Min, In-Gi;Kim, Jong-Dug;Yoon, Kyung-Hwan
    • Design & Manufacturing
    • /
    • v.2 no.5
    • /
    • pp.1-4
    • /
    • 2008
  • LCD-BLU (Liquid Crystal Display - Back Light Unit) is one of kernel parts of LCD unit and it consists of several optical sheets(such as prism, diffuser and protector sheets), LCP (Light Guide Plate), light source (CCFL or LED) and mold frame. The LGP of LCD-BLU is usually manufactured by forming numerous dots with $50-200{\mu}m$ in diameter on it by erosion method. But the surface of the erosion dots of LGP is very rough due to the characteristics of the erosion process during the mold fabrication, so that its light loss is high along with the dispersion of light into the surface. Accordingly, there is a limit in raising the luminance of LCD-BLU. Especially, the negative and positive micro-lens pattern fabricated by modified LiGA with thermal reflow process was applied to the optical design of LGP.

  • PDF

The Study on the Luminescent Element of Electro Chromisn in Polyelectrolyte (고분자전해질 Electro Chromism의 발광소자에 관한 연구)

  • 국상훈;고두석
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.2 no.1
    • /
    • pp.65-74
    • /
    • 1988
  • For experiment, we made the electro chemical display element with the NESA glass of display electrode which had low resistance. Density of injection charge, optical density and response characteristics were observed through coloring and achromatizing phemomena in the display element As optical electric chemical reaction was occured in $WO_3$ and cell, it was possible to repeat colouring and achromatizing, and the colouring characteristics was good. And the higher colouring and achromatizing voltage, the lower resistance of electrode and the thinner $WO_3$film was, the better response characteristics. With analyzing phenomena of electro chromism, we could find the possibility of practical use of the coloring and achromatizing element for clock, instrument and guide plate.

  • PDF

Investigation of Polishing Characteristics of Fused Silica Glass Using MR Fluid Jet Polishing (MR Fluid Jet Polishing 시스템에 의한 Fused Silica Glass 연마특성 고찰)

  • Lee, Jung-Won;Cho, Yong-Kyu;Cho, Myeong-Woo
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.5
    • /
    • pp.761-766
    • /
    • 2012
  • Abrasive fluid jet polishing processes have been used for the polishing of optical surfaces with complex shapes. However, unstable and unpredictable polishing spots can be generated due to the fundamental property of an abrasive fluid jet that it begins to lose its coherence as the jet exits a nozzle. To solve such problems, MR fluid jet polishing has been suggested using a mixture of abrasives and MR fluid whose flow properties can be readily changed according to imposed magnetic field intensity. The MR fluid jet can be stabilized by imposed magnetic fields, thus it can remain collimated and coherent before it impinges upon the workpiece surface. In this study, MR fluid jet polishing characteristics of fused silica glass were investigated according to injection time and magnetic field intensity variations. Material removal rates and 3D profiles of the generated polishing spots were investigated. From the results, it can be confirmed that the developed MR fluid polishing system can be applied for stable and predictable precise polishing of optical parts.

Electrical Leakage Levels Estimated from Luminescence and Photovoltaic Properties under Photoexcitation for GaN-based Light-emitting Diodes

  • Kim, Jongseok;Kim, HyungTae;Kim, Seungtaek;Choi, Won-Jin;Jung, Hyundon
    • Current Optics and Photonics
    • /
    • v.3 no.6
    • /
    • pp.516-521
    • /
    • 2019
  • The electrical leakage levels of GaN-based light-emitting diodes (LEDs) containing leakage paths are estimated using photoluminescence (PL) and photovoltaic properties under photoexcitation conditions. The PL intensity and open-circuit voltage (VOC) decrease because of carrier leakages depending on photoexcitation conditions when compared with reference values for typical LED chips without leakage paths. Changes of photovoltage-photocurrent characteristics and PL intensity due to carrier leakage are employed to assess the leakage current levels of LEDs with leakage paths. The current corresponding to the reduced VOC of an LED with leakage from the photovoltaic curve of a reference LED without leakage is matched with the leakage current calculated using the PL intensity reduction ratio and short-circuit current of the LED with leakage. The current needed to increase the voltage for an LED with a leakage under photoexcitation from VOC of the LED up to VOC of a reference LED without a leakage is identical to the additional current needed for optical turn-on of the LED with a leakage. The leakage current level estimated using the PL and photovoltaic properties under photoexcitation is consistent with the leakage level measured from the voltage-current characteristic obtained under current injection conditions.

High-Frequency Modeling and Optimization of E/O Response and Reflection Characteristics of 40 Gb/s EML Module for Optical Transmitters

  • Xu, Chengzhi;Xu, Y.Z.;Zhao, Yanli;Lu, Kunzhong;Liu, Weihua;Fan, Shibing;Zou, Hui;Liu, Wen
    • ETRI Journal
    • /
    • v.34 no.3
    • /
    • pp.361-368
    • /
    • 2012
  • A complete high-frequency small-signal circuit model of a 40 Gb/s butterfly electroabsorption modulator integrated laser module is presented for the first time to analyze and optimize its electro-optic (E/O) response and reflection characteristics. An agreement between measured and simulated results demonstrates the accuracy and validity of the procedures. By optimizing the bonding wire length and the impedance of the coplanar waveguide transmission lines, the E/O response increases approximately 5% to 15% from 20 GHz to 33 GHz, while the signal injection efficiency increases from approximately 15% to 25% over 18 GHz to 35 GHz.

A Wide-range Tunable Wavelength-stabilization Technique for Semiconductor Lasers

  • Chen, Han;Qiao, Qinliang;Min, Jing;He, Cong;Zhang, Yuanyuan
    • Current Optics and Photonics
    • /
    • v.5 no.4
    • /
    • pp.384-390
    • /
    • 2021
  • This paper presents a wide-range tunable wavelength-locking technology based on optoelectronic oscillation (OEO) loops for optical fiber sensors and microwave photonics applications, explains the theoretical fundamentals of the design, and demonstrates a method for locking the relative wavelength differences between a leader semiconductor laser and its follower lasers. The input of the OEO loop in the proposed scheme (the relative wavelength difference) determines the radio-frequency (RF) signal frequency of the oscillation output, which is quantized into an injection current signal for feedback to control the wavelength drift of follower lasers so that they follow the wavelength change of the leader laser. The results from a 10-hour continuous experiment in a field environment show that the wavelength-locking accuracy reached ±0.38 GHz with an Allan deviation of 6.1 pm over 2 hours, and the wavelength jitter between the leader and follower lasers was suppressed within 0.01 nm, even though the test equipment was not isolated from vibrations and the temperature was not controlled. Moreover, the tunable range of wavelength locking was maintained from 10 to 17 nm for nonideal electrical devices with limited bandwidth.