• 제목/요약/키워드: Optical Probe

검색결과 597건 처리시간 0.021초

Femtosecond degenerate and nondegenerate pump-probe experiments in bulk GaAs below the band gap

  • Yahng, J. S.;Kim, D. S.;Fatti, N.Del;Vallee, F.
    • Journal of the Optical Society of Korea
    • /
    • 제1권2호
    • /
    • pp.100-103
    • /
    • 1997
  • We perform degenerate and nondegenerate pump-probe experiments on bulk GaAs at 100 K below the band gap. We mostly observe a negative differential transmission signal both in the degenerate and nondegenerate experiments. We interpret our signal as due to two-photon absorption. This negative signal has a different origin from the normally considered band gap renormalization for resonant excitations.

Double clad fiber probe for fluorescence spectroscopy

  • Wang, Ling;Lee, Byeong-Ha
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2007년도 하계학술발표회 논문집
    • /
    • pp.35-36
    • /
    • 2007
  • We report a probe using a single double clad fiber (DCF) for fluorescence spectroscopy. Bidirectional separate transmission for excitation and fluorescence light in a single fiber was implemented. A DCF coupler made by side-polished method could extract none but the collected fluorescence signals propagating in inner cladding mode, thereby diminishing the interference of silica background generated by the excitation in core mode. The experimental results show that the fluorescence spectra of biological tissues obtained using the DCF probes have much less silica background than using a standard multiple-mode fiber.

  • PDF

RIE를 이용한 $Si_3$$N_4$막이 증착된 나노 탐침의 식각 및 제작 (Fabrication and Etching of Nano-probe Slide covered with $Si_3$$N_4$ by RIE)

  • 정은희;임상엽;주홍렬;박승한
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2003년도 하계학술발표회
    • /
    • pp.290-291
    • /
    • 2003
  • 근접장 측정에서 가장 많이 쓰이는 근접장 광섬유 탐침은 몇가지 단점을 가지고 있다. 단점 중 하나는 광 전달율이 매우 낮다는 점이다. 전형적으로 근접장 광섬유 탐침의 aperture가 100nm일때 빛이 통과할 때의 광 전달율은 $10^{-5}$만큼 떨어진다. 그리고 sample과 probe간의 수십 nm의 근접장거리를 유지하기 위해 복잡한 장치가 필요하다는 점이다. 이러한 단점을 보완하여 본 연구실에서는 근접장 측정에서 핵심이 되는 근접장 광섬유 탐침의 새로운 개념인 나노 탐침 제작을 연구하였다. (중략)

  • PDF

Development of Prototype Stylus Prototype for Large Optics Testing

  • Yang, Ho-Soon;Walker, David
    • Journal of the Optical Society of Korea
    • /
    • 제5권2호
    • /
    • pp.60-66
    • /
    • 2001
  • The authors discuss a prototype stylus profilometer designed to measure large optics. It consists of a low contact force type probe system, laser reference system, interferometric distance measurement system, and horizontal driving system. The probe contacts the surface ; the height and the horizontal distances of the measurement points are measured by the interferometer. The freely propagated laser beam provides the reference line during the measurement. The developed stylus profilometry shows only $\pm$60 nm of P-V error for the 157 mm diameter spherical mirror.

레이저 다이오드의 직접 광주파수 변조를 이용한 광섬유의 브릴루앙 이득 스펙트럼 측정 (Measurement of Brillouin Gain Spectrum of Optical Fiber Using Direct Optical Frequency Modulation of Laser Diode)

  • 서민성;윤승철;박희갑
    • 한국광학회지
    • /
    • 제17권2호
    • /
    • pp.143-148
    • /
    • 2006
  • 광섬유 내 브릴루앙 산란의 이득 스펙트럼을 측정하는 새로운 방법을 제안하고 실험하였다. 기존의 측정 방식과는 달리, 주입전류를 직접 변조하여 광주파수 변조된 하나의 레이저 다이오드로부터 펌프광과 프로브광을 발생시키고, 주입전류를 사각파로 변조할 때 나타나는 광주파수 처핑을 이용하여 펌프/프로브간 광주파수 차이를 연속적으로 변화시키는 방법으로 브릴루앙 이득 스펙트럼을 측정하였다. 통신용 단일모드 광섬유의 브릴루앙 이득 스펙트럼을 측정하여 기존 문헌의 결과와 거의 일치하는 결과를 얻었다.

광학식 수광 프로브의 실험적 성능평가 (Experimental Performance Evaluation of Optical Receiving Probe)

  • 양영준
    • 한국산업융합학회 논문집
    • /
    • 제7권3호
    • /
    • pp.265-271
    • /
    • 2004
  • A light collecting probe named Multi-colored Integrated Receiving Optics (MICRO) is experimentally examined to verify its performance. For these purposes, the time-series signals of MICRO probe is compared with those of electro-static probe and light-guided probe by monitoring, for example. such as OH radical chemiluminescence. CH radical band and droplet Mie scattering In addition, the experiment was conducted by using laminar premixed Bunsen flame, turbulent premixed Bunsen flame and premixed spray flame, respectively. It was confirmed that the performance of MICRO probe was very useful and convenient to obtain the chemiluminescence signals from local regions in turbulent premixed Bunsen flame and premixed spray flame.

  • PDF

G.652, G.653, G.655 광섬유에 대해 측정된 FWM 및 XPM 효율의 채널간격에 대한 의존성 (Dependence of XPM and FWM efficiencies on channel spacing for G.652, G.653, G.655 optical fibers)

  • 김근영;이용기
    • 한국광학회지
    • /
    • 제14권1호
    • /
    • pp.17-22
    • /
    • 2003
  • 본 논문은 다양한 분산값을 갖는 G.652. G.653, G.655(I),(II),(III) 광섬유에 대해 채널간격에 따른 FWM 효율을 측정하고 그 결과를 해석적으로 얻은 값과 비교 분석하였다. 또한 pump-probe 실험 구성을 사용하여 각 광섬유에 있어서 XPM 효율을 측정함으로써 색분산과 채널 간격이 XPM에 미치는 영향을 분석하였다.

Effect of Amplified Spontaneous Emission on the Gain Recovery of a Semiconductor Optical Amplifier

  • Lee, Hojoon
    • 한국광학회지
    • /
    • 제29권1호
    • /
    • pp.32-39
    • /
    • 2018
  • The impact of the amplified spontaneous emission (ASE) on the gain recovery time of a bulk semiconductor optical amplifier (SOA) is investigated. The gain-recovery time is obtained by determining the time evolution of the gain, carrier density, and ASE in an SOA, after the propagation of a short pump pulse and continuous-wave (CW) probe of gain dynamics. In the simulation, a wide-band-semiconductor model, which can be characterized by the material gain coefficient over a wide wavelength range, is used, because the gain bandwidth of a practical SOA is very wide. The pump pulse and counterpropagating CW probe field are considered in the simulation, with the ASE noise spectrum equally divided.

Implementation of Cost-effective Common Path Spectral Domain Free-hand Scanning OCT System

  • Shoujing Guo;Xuan Liu;Jin U. Kang
    • Current Optics and Photonics
    • /
    • 제7권2호
    • /
    • pp.176-182
    • /
    • 2023
  • Optical coherence tomography (OCT) is being developed to guide various ophthalmic surgical procedures. However, the high cost of the intraoperative OCT system limits its availability mostly to the largest hospitals and healthcare systems. In this paper, we present a design and evaluation of a low-cost intraoperative common-path free-hand scanning OCT system. The lensed fiber imaging probe is designed and fabricated for intraocular use and the free-hand scanning algorithm that could operate at a low scanning speed was developed. Since the system operates at low frequencies, the cost of the overall system is significantly lower than other commercial intraoperative OCT systems. The assembled system is characterized and shows that it meets the design specifications. The handheld OCT imaging probe is tested on multilayer tape phantom and ex-vivo porcine eyes. The results show that the system could be used as an intraoperative intraocular OCT imaging device.