• 제목/요약/키워드: Optical Microscope

검색결과 1,386건 처리시간 0.027초

세포 골격의 시각화 구현을 위한 단일 편광 조정 편광현미경 (Single polarization modulation polariscopic microscope for visualization of cytoskeleton)

  • 신인희;;안남희;신상모;김덕영
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2008년도 하계학술발표회 논문집
    • /
    • pp.269-270
    • /
    • 2008
  • Single polarization modulation polariscopic microscope for visualization of cytoskeleton was proposed for the first time. Algorithm of the single polarization modulation polariscopic microscope has beeen explained and accuracy and precision of the single polarization modulation polariscopic microscope have been measured in this paper.

  • PDF

수정 진동자를 이용한 근접장광학계 (Near-Field Scanning Optical Microscope) 제작 및 특성연구 (A study on the feedback control system for near field scanning optical microscope based on the tuning fork oscillator)

  • 윤선현
    • 한국광학회지
    • /
    • 제10권4호
    • /
    • pp.267-272
    • /
    • 1999
  • 근접장광학계 (Near-Field Scanning Optical Microscope :NSOM)의 표본과 팁의 거리 유지를 위해 소리굽쇠모양의 수정발진자 (tuning forktype quartz crystal unit)의 한쪽 다리에 광섬유를 고정시키고 광섬유 팁을 수정발진자와 같이 진동하게 만들어 사용하였다. 수정 진동자는 광섬유 팁이 시료에 얼마나 가까이 갔느냐에 따라 진폭이 바뀌게 되고 이 변화를 일반적인 방법인 레이저 빛에 의하여 읽어내는 것이 아니라 바로 수정 발진자의 임피던스 변화에 따른 전압 변화를 측정하여 알아냈다. 팁이 표면에 접근함에 따라 수정발진자 진동폭의 변화와 팁을 통해 들어오는 빛의 세기 변화 등을 측정하여 계의 감도를 조사하였다.

  • PDF

광섬유의 직접 구동에 의한 공초점 현미경 (Scanning confocal microscope by direct oscillation of an optical fiber)

  • 김종배;류광현;박두성;노정은;권남익
    • 한국광학회지
    • /
    • 제14권1호
    • /
    • pp.80-84
    • /
    • 2003
  • 두 가지의 다른 방법으로 광섬유를 직접 구동하여 공초점 현미경을 제작하였다. 압전소자와 튜닝 포크는 광섬유를 진동시키는데 사용하였다. 6 frame의 640$\times$480 픽셀 영상을 압전소자 진동으로 1초 동안 얻었고, 1 frame의 640$\times$480 픽셀 영상을 튜닝 포크 진동으로 1초 동안 얻었다 이러한 광섬유의 진동은 confocal 영상에 일그러짐을 주지 않았다.

광학현미경을 이용한 비접촉식 치수측정시스템의 교정 (Calibration of Optical Dimensional Measurement System Using Optical Microscope)

  • 박현구;박민철;김승우
    • 한국정밀공학회지
    • /
    • 제14권11호
    • /
    • pp.118-125
    • /
    • 1997
  • Non-contacting optical microscopes are increasingly used in recent industrial applications of probes for coordinate measuring machines. They have been found more efficient than conventional touch trigger porbes with ball tips especially in inspecting small-sized objects. There are two major factors affecting measuring accuracy: (1) geometric relations between coordinate systems, (2) magnification ratios of a microscope. In order to determine the magnification ratios exactly, optical imaging of edge was theroretically analyzed and practically adopted to image processing for edge detection. In addition, this paper proposes a geometric calibration method to obtain exact coordinates of measured points from the relations between the machine coordinate system and the image. In the method, the error according to the squareness between the machine axises was also removed. The method was practically adopted to a real coordinate measuring machine. An ultraprecision measurement of 0.2 um uncertainty can be practically achieved.

  • PDF

초정밀 열 영상 현미경 광학계 개발 (Development of the Ultra Precision Thermal Imaging Optical System)

  • 양순철;원종호
    • 한국정밀공학회지
    • /
    • 제27권12호
    • /
    • pp.15-21
    • /
    • 2010
  • Recently, there is a demand for a thermal imaging microscope in the medical field as well as the semi-conductor industry Although the demand of the advanced thermal imaging microscope has been increased, it is very difficult to obtain the technology of developing a thermal camera, because it is used for defense industry. We developed the ${\times}5$ zoom microscope which has $3\;{\mu}m$ spatial resolution to research the design and fabrication of the IR (Infrared) optical system. The optical system of the IR microscope consists of four spherical lenses and four aspheric lenses. We verified individual sensitivity of each optical parameter as the first order approach to the analysis. And we also performed structure and vibration analysis. The optical elements are fabricated using Freeform 700A. The measurement results of surface roughness and form accuracy using NT 2000 and UA3P are Ra 2.36 nm and P-V $0.13\;{\mu}m$. Finally we ascertained resolution power of $3\;{\mu}m$ using USAF (United State Air Force) 1951 IR resolution test chart.

Developing a Cantilever-type Near-field Scanning Optical Microscope Using a Single Laser for Topography Detection and Sample Excitation

  • Ng'ang'a, Douglas Kagoiya;Ali, Luqman;Lee, Yong Joong;Byeon, Clare Chisu
    • Current Optics and Photonics
    • /
    • 제5권3호
    • /
    • pp.229-237
    • /
    • 2021
  • The capabilities of the near-field scanning optical microscope (NSOM) for obtaining high resolution lateral topographical images as well as for mapping the spectroscopic and optical properties of a sample below the diffraction limit of light have made it an attractive research field for most researchers dealing with optical characteristics of materials in nano scales. The apertured NSOM technique involves confining light into an aperture of sub-wavelength size and using it to illuminate a sample maintained at a distance equal to a fraction of the sub-wavelength aperture (near-field region). In this article, we present a setup for developing NSOM using a cantilever with a sub-wavelength aperture at the tip. A single laser is used for both cantilever deflection measurement and near-field sample excitation. The laser beam is focused at the apex of the cantilever where a portion of the beam is reflected and the other portion goes through the aperture and causes local near-field optical excitation of the sample, which is then raster scanned in the near-field region. The reflected beam is used for an optical beam deflection technique that yields topographical images by controlling the probe-sample in nano-distance. The fluorescence emissions signal is detected in far-field by the help of a silicon avalanche photodiode. The images obtained using this method show a good correlation between the topographical image and the mapping of the fluorescence emissions.

근접장 주사 현미경을 이용한 광도파로 특성 연구 (A study for the waveguide characterization using the near-field scanning optical microscope)

  • 지원수;김대찬;정재완;이승걸;오범환;이일항
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2001년도 제12회 정기총회 및 01년도 동계학술발표회
    • /
    • pp.122-123
    • /
    • 2001
  • 본 연구에서는 주사 근접장 광학 현미경(Near-field Scanning Optical Microscope, 이하 NSOM이라 한다)을 이용하여 빛이 전파되고 있는 광 도파로 주변에 형성되는 evanescent field를 측정함으로써 광도파로 내부에서의 빛의 전파특성을 알아보았다. 광소자의 설계에 있어서 광도파로 내부에서의 빛이 어떻게 전파되어지는 가는 매우 중요한 인자가 된다. (중략)

  • PDF

물체표면의 3차원 정밀형상측정을 위한 공초점 현미경에 관한 연구 (A Study on Confocal Microscope for A Precise 3-Dimensional Surface Measurement)

  • 송대호;안중근;강영준;채희창
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 추계학술대회 논문집
    • /
    • pp.233-236
    • /
    • 1997
  • In modem industry, the accuracy and the surface-finish requirements for machined parts have been becoming ever more stringent. Optical method in measurements is playing an important role in vibration measurement, crack and defect detection and surface topography with the advent of opto-mechatronics. In this study, the principle of the general confocal microscope is introduced for surface measurement, and the advanced confocal microscope that has better measuring speed than the traditional confocal microscope is developed. A study on improving the resolution of the advanced confocal microscope is followed. Finally, Software for data acquisition and analysis of various parameters in surface geometrical features has been developed.

  • PDF

레이저 유도 광열 효과를 이용하여 제작된 오목한 광섬유 팁의 곡률 반경에 관한 연구 (A Study on the Radius of Curvature of Concave Optical Fiber Tips fabricated by Laser-Induced Photothermal Effect)

  • 최지원;손경호;유경식
    • 한국전자통신학회논문지
    • /
    • 제14권5호
    • /
    • pp.871-876
    • /
    • 2019
  • 본 논문에서는 플루오린화 수소산(Hydrofluoric acid: HF) 수용액과 광섬유에 인가된 $1.55{\mu}m$ 파장의 레이저를 통해 유도된 광열 효과를 이용하여 오목한 광섬유 팁을 제작하였다. 제작 과정에서 인가한 레이저의 세기, 식각 시간, HF 수용액의 농도에 따른 광섬유 팁 오목 면의 곡률 반경을 광학 현미경을 이용하여 측정하였으며 곡률 반경이 세 변인에 대하여 어떻게 변화하는지 분석하였다. 또한, Free Spectral Range(FSR)와 Scanning electron microscope(SEM) 촬영을 통해 현미경을 이용한 측정 방법의 신뢰성을 검증하였다. 본 논문을 통해 광섬유 팁의 오목 면 제작 과정에서 변인에 따라 곡률 반경을 조절할 수 있게 됨으로써 기존의 HF 수용액을 이용한 광섬유 식각 방법의 한계점을 극복할 수 있었다.

근접장 주사 광학현미경을 이용한 광 도파로 특성 연구 (Characterization of optical waveguides with near - field scanning optical microscope)

  • 지원수;김대찬;이승걸;오범환;이일항
    • 한국광학회지
    • /
    • 제13권4호
    • /
    • pp.301-307
    • /
    • 2002
  • 광 도파로를 따라 전파하는 빛의 특성을 측정하기 위해 근접장 주사 광학현미경(Near-field scanning optical microscope, NSOM)으로 광 도파로의 표면에 형성된 에바네슨트 파 evanescent wave)의 분포를 측정하였다. 사용된 NSOM은 photon scanning tunneling microscope방식으로 본 연구의 목적에 적합하도록 직접 제작한 것이다. 광원 파장 1550㎚에서 단일 모드 다중 모드 채널형 광 도파로에 대해 도파로 표면에 형성된 에바네슨트 파의 분포를 측정하였으며, 3차원 빔전파방법(Beam Propagation Method)으로 계산된 수치 해석 결과와 두 모드 간의 간섭 형상을 직접적으로 확인할 수 있었다.