• Title/Summary/Keyword: Optical Interferometer

Search Result 614, Processing Time 0.028 seconds

Electro-optic Electric Field Sensor Utilizing Ti:LiNbO3 Symmetric Mach-Zehnder Interferometers

  • Jung, Hong-Sik
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.1
    • /
    • pp.47-52
    • /
    • 2012
  • The use of a $Ti:LiNbO_3$ symmetric Mach-Zehnder interferometric intensity modulator with a push-pull lumped electrode and a plate-type probe antenna to measure an electric field strength is described. The modulator has a small device size of $46{\times}7{\times}1mm$ and operates at a wavelength of $1.3{\mu}m$. The output characteristic of the interferometer shows the modulation depth of 100% and 75%, and $V_{\pi}$ voltage of 6.6 V, and 6.6 V at the 200 Hz and 1 KHz, respectively. The minimum detectable electric field is ~1.84 V/m, ~3.28 V/m, and ~11.6 V/m, corresponding to a dynamic range of about ~22 dB, ~17 dB, and ~6 dB at frequencies of 500 KHz, 1 MHz and 5 MHz, respectively.

Single Mode Lasing in InGaAsP/InP Semiconductor Coupled Square Ring Cavities

  • Hyun, Kyung-Sook;Lee, Taekyu;Moon, Hee-Jong
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.2
    • /
    • pp.157-161
    • /
    • 2012
  • This work reports the stability of the resonant characteristics in multimode interferometer coupled square ring semiconductor cavities. Based on the analysis of single square ring cavities, the single mode operations in the multimode interferometer coupled ring cavities are analyzed and the devices are demonstrated on the semiconductor multiple quantum well epitaxial structure. By varying the lasing conditions such as substrate temperature and input pump power, single resonant mode operations are also observed.

Using MZIs for Optical PSBT Transmissions: Requirements for Thermal Stabilization

  • Ducournau, Guillaume;Latry, Olivier;Ketata, Mohamed
    • ETRI Journal
    • /
    • v.28 no.5
    • /
    • pp.615-620
    • /
    • 2006
  • In this paper, we discuss the quantification of Mach-Zehnder interferometer (MZI) thermal stabilization which is needed in optical phase shaped binary transmission (PSBT) links. Considering the thermo-optic and thermal expansion effects, we revisit the analytical expression for the thermal drift (GHz/$^{\circ}C$) of the MZI center frequency (denoted here by the 'MZI spectral drift'). An MZI is then used in an experimental transmission system using the optical PSBT format. We study the effect of spectral MZI drift by using a thermally stabilized interferometer and applying a frequency shift to the optical carrier. By using the thermal drift coefficient of the MZI, we find that to ensure low bit error rate fluctuations due to the MZI drift, the thermal stabilization of the device must have an accuracy of $0.5^{\circ}C$.

  • PDF

Rotational Prism Stitching Interferometer for High-resolution Surface Testing (고해상도 표면 측정을 위한 회전 프리즘 정합 간섭계)

  • In-Ung Song;Woo-Sung Kwon;Hagyong Khim;Yun-Woo Lee;Jong Ung Lee;Ho-Soon Yang
    • Korean Journal of Optics and Photonics
    • /
    • v.34 no.3
    • /
    • pp.117-123
    • /
    • 2023
  • The size of an optical surface can significantly affect the performance of an optical system, and high spatial frequency errors have a greater impact. Therefore, it is crucial to measure the surface figure error with high frequency. To address this, a new method called rotational prism stitching interferometer (RPSI) is proposed in this study. The RPSI is a type of stitching interferometer that enhances spatial resolution, but it differs from conventional stitching interferometers in that it does not require the movement of either the mirror tested or the interferometer itself to obtain sub-aperture interferograms. Instead, the RPSI uses a beam expander and a rotating Dove prism to select particular sub-apertures from the entire aperture. These sub-apertures are then stitched together to obtain a full-aperture result proportional to the square of the beam expander's magnification. The RPSI's effectiveness was demonstrated by measuring a 40 mm diameter spherical mirror using a three-magnification beam expander and comparing the results with those obtained from a commercial interferometer. The RPSI achieved surface testing results with nine times higher sampling density than the interferometer alone, with a small difference of approximately 1 nm RMS.

Nonlinearlity Compensation of Heterodyne laser interferometer based on LMS (LMS를 이용한 헤테로다인 레이저 간섭계 비선형성 보정)

  • Jeong, Pil-Joong;Lee, Woo-Ram;You, Kwan-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2007.10a
    • /
    • pp.283-284
    • /
    • 2007
  • In this paper we introduce a compensation of nonlinearity Heterodyne laser interferometer. The Laser Interferometer is used for length measurement in various industries. However, it has nonlinearity error caused by the imperfect optical equipment. This acts as an obstacle in the measurement improvement. We propose an adaptive error compensation using least mean square(LMS) to improve precision.

  • PDF

STUDIES OF HIGH-LATITUDE THERMOSPHERE UTILIZING OPTICAL INSTRUMENTS

  • WON YOUNG-IN;CHO YOUNG-MIN;KIM YONG-HA
    • Publications of The Korean Astronomical Society
    • /
    • v.15 no.spc2
    • /
    • pp.27-35
    • /
    • 2000
  • The investigation of the space environment requires the use of experimental and theoretical tools and resources in order to perform the research task. Understanding of these research tools is imperative for proper interpretation of the results. In this paper, we discuss on research tools that are widely used in the field of aeronomy; Fabry-Perot interferometer and Michelson interferometer. These instruments have been used extensively as passive optical devices, spectrally monitoring the natural atmospheric emissions (airglow). This function has made both instruments valuable tools in upper atmospheric studies since they provide the ability to determine the dynamic and thermodynamic properties of the upper atmosphere by monitoring naturally-occuring emission.

  • PDF

Optical Implementation of Three-Dimensional Image using Modified Triangular Interferometer (변형 삼각간섭계를 이용한 3차원 영상의 광학적 구현)

  • 김수길
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.1
    • /
    • pp.15-20
    • /
    • 2004
  • We presented the optical reconstruction system of complex hologram and theoretically demonstrated that the proposed system could display complex hologram. And we made the complex hologram of a three-dimensional image using the modified triangular interferometer, and presented and analyzed the three-dimensional images numerically and optically reconstructed from it.

Detection of Excited Vibration frequency on the Latticed Fence Structure Using a Distributed Fiber Optic Sensor (격자형 구조물의 외부 진동 주파수 탐지를 위한 분포형 광섬유 센서 설계 및 실험)

  • Lee, Jong-Kil
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.234-237
    • /
    • 2002
  • To detect external vibration signals on the latticed fence structure, distributed fiber optic sensor using Sagnac interferometer was fabricated and tested. The latticed structure fabricated with dimension of 170cm in width and 180cm in height, the optical fiber, 50m in length, distributed and fixed on the latticed structure. It was verified the sensitivity of the Sagnac interferometer using the PZT phase modulator. Fiber optic external vibration signal spplied to the latticed fence structure from 100Hz to several kHz. The interferometeric fiber optic sensor detected the excited vibration signal very effectively without any signal processing. The detected optical signals were compared and analyzed to the detected acclerometer signals.

  • PDF

The study of property on the michelson interferometric microscopy (마이켈슨 간섭계형 현미경의 특성 연구)

  • 김경신;권남익
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.5
    • /
    • pp.369-372
    • /
    • 1999
  • We have constructed an interferometric microscopy using a Michelson interferometer and a He-Ne laser. The three dimensional image was obtained by the interference from the reflected signal by a sample surface and from the reflected signal by a mirror. The axial resolution obtained by Michelson interferometric microscopy is as good as that of the white-light interferometer, but the same fringe is obtained when optical path difference is half-wavelength. The image from Michelson interferometric microscopy was compared with the images from the various types of confocal microscopy.

  • PDF

Analysis on the error of sensitivity vector of holographic interferometer for measuring out-of-plane displacement (면외변위 측정을 위한 홀로그래픽 간섭계의 민감도백터의 오차 해석)

  • 문상준;강영준;백성훈;김철중
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.515-518
    • /
    • 1994
  • Holographic interferometry is a useful whole-field nondestructive testing for measuring deformations and vibrations of engineering structure. A diverging beam is used as a light source int the most of holographic interferometer practically. For a relatively small object the optical arrangement using a collimated light source has no difficulty in use technically, but for a large object it is difficult to use a collimated beam. In this study we calculate the error of measured displacement from the sensitivity vector dominated by the geometry of optical arrangement for holographic interferometer and show the result obtained with 2-D plots. A Plane surface and a cylindrical surface were chosen as objects to be calculated and computer analysis was carried out for the cases of a diverging beam and a collimated one.

  • PDF