• 제목/요약/키워드: Optical Interferometer

검색결과 614건 처리시간 0.029초

Electro-optic Electric Field Sensor Utilizing Ti:LiNbO3 Symmetric Mach-Zehnder Interferometers

  • Jung, Hong-Sik
    • Journal of the Optical Society of Korea
    • /
    • 제16권1호
    • /
    • pp.47-52
    • /
    • 2012
  • The use of a $Ti:LiNbO_3$ symmetric Mach-Zehnder interferometric intensity modulator with a push-pull lumped electrode and a plate-type probe antenna to measure an electric field strength is described. The modulator has a small device size of $46{\times}7{\times}1mm$ and operates at a wavelength of $1.3{\mu}m$. The output characteristic of the interferometer shows the modulation depth of 100% and 75%, and $V_{\pi}$ voltage of 6.6 V, and 6.6 V at the 200 Hz and 1 KHz, respectively. The minimum detectable electric field is ~1.84 V/m, ~3.28 V/m, and ~11.6 V/m, corresponding to a dynamic range of about ~22 dB, ~17 dB, and ~6 dB at frequencies of 500 KHz, 1 MHz and 5 MHz, respectively.

Single Mode Lasing in InGaAsP/InP Semiconductor Coupled Square Ring Cavities

  • Hyun, Kyung-Sook;Lee, Taekyu;Moon, Hee-Jong
    • Journal of the Optical Society of Korea
    • /
    • 제16권2호
    • /
    • pp.157-161
    • /
    • 2012
  • This work reports the stability of the resonant characteristics in multimode interferometer coupled square ring semiconductor cavities. Based on the analysis of single square ring cavities, the single mode operations in the multimode interferometer coupled ring cavities are analyzed and the devices are demonstrated on the semiconductor multiple quantum well epitaxial structure. By varying the lasing conditions such as substrate temperature and input pump power, single resonant mode operations are also observed.

Using MZIs for Optical PSBT Transmissions: Requirements for Thermal Stabilization

  • Ducournau, Guillaume;Latry, Olivier;Ketata, Mohamed
    • ETRI Journal
    • /
    • 제28권5호
    • /
    • pp.615-620
    • /
    • 2006
  • In this paper, we discuss the quantification of Mach-Zehnder interferometer (MZI) thermal stabilization which is needed in optical phase shaped binary transmission (PSBT) links. Considering the thermo-optic and thermal expansion effects, we revisit the analytical expression for the thermal drift (GHz/$^{\circ}C$) of the MZI center frequency (denoted here by the 'MZI spectral drift'). An MZI is then used in an experimental transmission system using the optical PSBT format. We study the effect of spectral MZI drift by using a thermally stabilized interferometer and applying a frequency shift to the optical carrier. By using the thermal drift coefficient of the MZI, we find that to ensure low bit error rate fluctuations due to the MZI drift, the thermal stabilization of the device must have an accuracy of $0.5^{\circ}C$.

  • PDF

고해상도 표면 측정을 위한 회전 프리즘 정합 간섭계 (Rotational Prism Stitching Interferometer for High-resolution Surface Testing)

  • 송인웅;권우성;김학용;이윤우;이종웅;양호순
    • 한국광학회지
    • /
    • 제34권3호
    • /
    • pp.117-123
    • /
    • 2023
  • 반사경의 광학면이 넓어질수록 높은 공간 주파수 형상이 광학계의 성능에 큰 영향을 주므로, 대형 반사경 성능 평가에서 이를 측정할 수 있어야 한다. 따라서 높은 주파수의 형상을 샘플링할 수 있는 고해상도 형상 측정 시스템이 필요하다. 본 연구에서는 반사경의 고해상도 형상 측정을 위한 회전 프리즘 정합 간섭계(rotational prism stitching interferometer, RPSI)라는 새로운 방법을 제안한다. RPSI는 기존에 사용되고 있는 상용 간섭계에 빔 확장 렌즈, 이송 거울, 회전 프리즘 등을 추가하여 구성되었으며, 간섭계를 움직이지 않고 원통 좌표계를 기준으로 전체 구경을 아우르는 부분 구경 형상들을 측정한다. 측정된 부분 구경들은 최소자승법을 이용한 부분 구경 정합법을 이용하여 정합되며, 빔확장 렌즈 배율의 제곱만큼 높은 샘플링 밀도로 전체 구경 형상 정보를 복원 가능하다. 3배율을 가지는 RPSI를 이용하여 직경 40 mm의 구면 반사경 형상을 측정하였고, 간섭계 단독으로 측정한 전체 구경 형상과 비교 검증하였다. 약 1 nm RMS의 근소한 차이로 유사한 형상을 잘 복원할 수 있었으며, 간섭계 단독으로 사용한 형상 측정 결과보다 렌즈의 배율의 제곱배만큼 향상된 샘플링 밀도로 형상 측정이 가능함을 확인하였다.

LMS를 이용한 헤테로다인 레이저 간섭계 비선형성 보정 (Nonlinearlity Compensation of Heterodyne laser interferometer based on LMS)

  • 정필중;이우람;유관호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.283-284
    • /
    • 2007
  • In this paper we introduce a compensation of nonlinearity Heterodyne laser interferometer. The Laser Interferometer is used for length measurement in various industries. However, it has nonlinearity error caused by the imperfect optical equipment. This acts as an obstacle in the measurement improvement. We propose an adaptive error compensation using least mean square(LMS) to improve precision.

  • PDF

STUDIES OF HIGH-LATITUDE THERMOSPHERE UTILIZING OPTICAL INSTRUMENTS

  • WON YOUNG-IN;CHO YOUNG-MIN;KIM YONG-HA
    • 천문학논총
    • /
    • 제15권spc2호
    • /
    • pp.27-35
    • /
    • 2000
  • The investigation of the space environment requires the use of experimental and theoretical tools and resources in order to perform the research task. Understanding of these research tools is imperative for proper interpretation of the results. In this paper, we discuss on research tools that are widely used in the field of aeronomy; Fabry-Perot interferometer and Michelson interferometer. These instruments have been used extensively as passive optical devices, spectrally monitoring the natural atmospheric emissions (airglow). This function has made both instruments valuable tools in upper atmospheric studies since they provide the ability to determine the dynamic and thermodynamic properties of the upper atmosphere by monitoring naturally-occuring emission.

  • PDF

변형 삼각간섭계를 이용한 3차원 영상의 광학적 구현 (Optical Implementation of Three-Dimensional Image using Modified Triangular Interferometer)

  • 김수길
    • 조명전기설비학회논문지
    • /
    • 제18권1호
    • /
    • pp.15-20
    • /
    • 2004
  • 복소홀로그램을 광학적으로 구현할 수 있는 시스템을 제안하고, 제안된 시스템이 복소홀로그램을 표현할 수 있다는 것을 이론적으로 입증하였다. 그리고, 변형 삼각간섭계를 이용하여 3차원 영상의 복소홀로그램을 생성하고, 이를 수치적 및 광학적으로 복원한 3차원 영상을 제시하고 분석하였다.

격자형 구조물의 외부 진동 주파수 탐지를 위한 분포형 광섬유 센서 설계 및 실험 (Detection of Excited Vibration frequency on the Latticed Fence Structure Using a Distributed Fiber Optic Sensor)

  • 이종길
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.234-237
    • /
    • 2002
  • To detect external vibration signals on the latticed fence structure, distributed fiber optic sensor using Sagnac interferometer was fabricated and tested. The latticed structure fabricated with dimension of 170cm in width and 180cm in height, the optical fiber, 50m in length, distributed and fixed on the latticed structure. It was verified the sensitivity of the Sagnac interferometer using the PZT phase modulator. Fiber optic external vibration signal spplied to the latticed fence structure from 100Hz to several kHz. The interferometeric fiber optic sensor detected the excited vibration signal very effectively without any signal processing. The detected optical signals were compared and analyzed to the detected acclerometer signals.

  • PDF

마이켈슨 간섭계형 현미경의 특성 연구 (The study of property on the michelson interferometric microscopy)

  • 김경신;권남익
    • 한국광학회지
    • /
    • 제10권5호
    • /
    • pp.369-372
    • /
    • 1999
  • 마이켈슨 간섭계를 이용한 간섭계형 현미경을 구성하고 특성을 조사하였다. 본 마이켈슨 간섭계형 현미경은 시료 표면의 반사 신호와 거울의 반사 신호가 합쳐져서 일어난 간섭 신호를 이용해서 3차원 영상을 얻는다. He-Ne(λ=633 nm)레이저를 사용한 마이켈슨 간섭계는 반파장 (312.5 nm)의 경로차가 생길 때마다 같은 무늬가 반복해져 나타난다. 본 마이켈슨 간섭계형 현미경은 이러한 간섭 신호를 이용하기 때문에 white-light interferometer 수준의 수직 해상도를 얻을 수 있었다. 구성한 마이켈슨 간섭계형 현미경으로 얻은 영상을 공초점 현미경의 영상과 비교 분석하였다.

  • PDF

면외변위 측정을 위한 홀로그래픽 간섭계의 민감도백터의 오차 해석 (Analysis on the error of sensitivity vector of holographic interferometer for measuring out-of-plane displacement)

  • 문상준;강영준;백성훈;김철중
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1994년도 추계학술대회 논문집
    • /
    • pp.515-518
    • /
    • 1994
  • Holographic interferometry is a useful whole-field nondestructive testing for measuring deformations and vibrations of engineering structure. A diverging beam is used as a light source int the most of holographic interferometer practically. For a relatively small object the optical arrangement using a collimated light source has no difficulty in use technically, but for a large object it is difficult to use a collimated beam. In this study we calculate the error of measured displacement from the sensitivity vector dominated by the geometry of optical arrangement for holographic interferometer and show the result obtained with 2-D plots. A Plane surface and a cylindrical surface were chosen as objects to be calculated and computer analysis was carried out for the cases of a diverging beam and a collimated one.

  • PDF