• 제목/요약/키워드: Optical Fault

검색결과 76건 처리시간 0.031초

기계적 손상에 의한 실리콘 웨이퍼의 반송자 수명과 표면 거칠기와의 관계 (Relationships between Carrier Lifetime and Surface Roughness in Silicon Wafer by Mechanical Damage)

  • 최치영;조상희
    • 한국전기전자재료학회논문지
    • /
    • 제12권1호
    • /
    • pp.27-34
    • /
    • 1999
  • We investigated the effect of mechanical back side damage in viewpoint of electrical and surface morphological characteristics in Czochralski silicon wafer. The intensity of mechanical damage was evaluated by minority carrier recombination lifetime by laser excitation/microwave reflection photoconductance decay technique, atomic force microscope, optical microscope, wet oxidation/preferential etching methods. The data indicate that the higher the mechanical damage degree, the lower the minority carrier lifetime, and surface roughness, damage depth and density of oxidation induced stacking fault increased proportionally.

  • PDF

광센서를 이용한 과전류 보호계전의 응답특성 연구 (Response characteristic of over current relay using optical sensor)

  • 박병석;안성준;조홍근
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.1364-1366
    • /
    • 1997
  • To operate electric power systems economically and stably, and to supply the electric power of good quality, it is necessary that the measured information (current, voltage, and so on) be detected and transmutted with high reliability and high effieincy. For the reason, the optical magnetic field sensor is possible to rapidly detect to over current and recover when electric power line have fault. In addition, the optical sensor have no electro magnetic distortion and no electric insulation. In this study, we designed OCR(Over Current Relay) using optical sensor. The designed OCR using optical sensor was measured characteristic and compared contentional OCR. This system have highest optical advantages and reliability.

  • PDF

Real-time Monitoring of Ethernet Passive Optical Network Using Burst-mode FBGs

  • Binh, Nguyen Khac;Choi, Su-il
    • Current Optics and Photonics
    • /
    • 제4권3호
    • /
    • pp.186-192
    • /
    • 2020
  • This paper describes a real-time monitoring system in Ethernet passive optical networks (EPON) that uses burst-mode fiber Bragg grating (FBG) optical sensors. The FBG interrogation unit in the optical line terminal (OLT) transmits the monitoring wavelength to optical network units (ONUs). The FBG sensor unit in each ONU returns a burst-mode monitoring signal to the OLT. As the system applies time division multiple access (TDMA), a uniform Bragg wavelength can be used to monitor the EPON system. The FBG interrogation unit analyzes the received burst-mode monitoring signals and outputs fault information on the ONU branches in EPON. The simulation results show the effectiveness of the proposed monitoring system based on TDMA. In addition, we compared the proposed TDMA-based monitoring system with a WDMA-based monitoring system.

해저광케이블 수리를 위한 효율적인 탐지 및 측정 기법 (Efficient Test Techniques for Submarine Cable Repair)

  • 이영선;정재진;신현식
    • 한국전자통신학회논문지
    • /
    • 제3권1호
    • /
    • pp.1-7
    • /
    • 2008
  • 해저광케이블은 국제통신의 98% 이상을 처리하고 있는 국가의 중요한 정보통신 인프라이다. 하지만 선박의 닻, 어선의 어구, 해저 지진 등 다양한 요인으로 인해 고장이 발생하며, 고장 발생시 대용량 해저통신 트래픽의 영향을 최소화하고, 케이블 수리 선박의 운영비용 절감을 위해서 수리 기간을 최대한 단축해야 한다. 해저광케이블 고장 유형은 Shunt Fault, Cable Cut, Open Fault, Fiber Break 등 여러 유형이 있으며, 고장이 발생하면 육상 터미널 국사(육양국)에서 정확하고 신속하게 고장 유형 및 고장 지점을 파악하고, 케이블 수리 선박은 수리 현장으로 출동하여 수리 작업을 수행하게 된다. 수리작업 기간 중 육양국에서는 케이블 수리 선박에서 요청하는 각종 Test를 수행하게 되며, 이때 육양국 Test 기법은 매우 중요하다. 본 논문에서는 해저광케이블 고장 유형 및 고장 지점 탐지 기법을 제시하고, 해저광케이블 수리기간 단축을 위한 육양국 Test 기법을 고찰하고자 한다.

  • PDF

Use of In-Situ Optical Emission Spectroscopy for Leak Fault Detection and Classification in Plasma Etching

  • Lee, Ho Jae;Seo, Dong-Sun;May, Gary S.;Hong, Sang Jeen
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제13권4호
    • /
    • pp.395-401
    • /
    • 2013
  • In-situ optical emission spectroscopy (OES) is employed for leak detection in plasma etching system. A misprocessing is reported for significantly reduced silicon etch rate with chlorine gas, and OES is used as a supplementary sensor to analyze the gas phase species that reside in the process chamber. Potential cause of misprocessing reaches to chamber O-ring wear out, MFC leaks, and/or leak at gas delivery line, and experiments are performed to funnel down the potential of the cause. While monitoring the plasma chemistry of the process chamber using OES, the emission trace for nitrogen species is observed at the chlorine gas supply. No trace of nitrogen species is found in other than chlorine gas supply, and we found that the amount of chlorine gas is slightly fluctuating. We successfully found the root cause of the reported misprocessing which may jeopardize the quality of thin film processing. Based on a quantitative analysis of the amount of nitrogen observed in the chamber, we conclude that the source of the leak is the fitting of the chlorine mass flow controller with the amount of around 2-5 sccm.

과전류 계측을 위한 광자계센서의 구현 (Implementation of Optical Magnetic Field Sensor for Measurement of Over Current)

  • 박해수;노종대;김요희;박병석;안성준;조홍근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 E
    • /
    • pp.1871-1873
    • /
    • 1997
  • The conventional current transformers are often take faults and out of order that for detect to over current of electric power lines because electromagnetic interference. But, it is possible to implement protection relay of high reliability using optical magnetic field sensor which are immunity and small size. The optical magnetic field sensor is possible to rapidly detect to over current and recover when electric power line have fault. And it is not necessary to make with capacitance of electric power lines as optical magnetic field sensor is have linearity from 0 to about 20kA. In this study, we designed and constructed compensative feedback circuit in order to minimize of optical power intensity variation with environ- mental variations(temperature, drive current) of light source. And this system have highest optical advantages and reliability.

  • PDF

반도체 장치의 결함해석 (Fault Analysis of Semiconductor Device)

  • 박석준;최성배;오창섭
    • 에너지공학
    • /
    • 제25권1호
    • /
    • pp.192-197
    • /
    • 2016
  • 새로운 재료가 개발되어 점점 반도체 디바이스의 적용으로 인해 반도체 장치 구조의 미세화를 촉진하고 있고 반도체 디바이스의 제조공정에서는 초기불량이나 일정시간 가동 후의 고장이 끊이지 않고 발생하고 있어 그 결함에 대한 해석은 날이 갈수록 중요해지고 있다. 여기서는 반도체 디바이스의 전기적 고장 검출과 디바이스 결함부의 물리해석에 대해 서술한다. 물리해석에는 주사전자현미경이나 투과전자현미경, 집속이온빔가공장치와 같은 전자나 이온을 이용한 장치가 사용되는데 여기서는 그 사용기술과 특성에 대해 서술하고자 한다.

DWDM기반의 OVPN에서 네트워크 생존성을 위한 제어 메커니즘 연구 ((A Study on the Control Mechanism for Network Survivability in OVPN over IP/GMPLS over DWDM))

  • 조광현;정창현;홍경동;김성운
    • 대한전자공학회논문지TC
    • /
    • 제42권9호
    • /
    • pp.85-96
    • /
    • 2005
  • "인터넷을 기반으로 하는 VPN(Virt at Private Network)"은 비용과 운용측면에서 효율적이다 하지만 광 대역폭 그리고 신뢰성 있는 서비스에 대한 요구의 증가는 IP/GMPLS over DWDM 기반의 백본 네트워크가 차세대 OVPN (Optical VPN)을 위하여 가장 적합한 백본 네트워크로 간주되게 하였다. 그러나, 높은 데이터 전송율을 가지는 OVPN망에서 광 소자의 일시적인 fault/attack에 의해서 일어나는 서비스 파괴는 순식간에 막대한 트래픽 손실을 야기 할 수 있으며, 비 인가된 physical attack 으로 인하여 물리적인 구성소자를 통해 정보가 도청 될 수 있다 또한 데이터 전송을 관리하는 제어 메시지가 변조되거나 복사되어 조작될 경우 데이터가 전송도중 실패하더라도 망의 생존성을 보장할수가 없게 된다. 따라서, OVPN에서는 생존성 문제 (i.e. fault/attack에 대한 물리적인 구조와 광 소자를 고려한 최적의 복구 매커니즘, 그리고 GMPLS 제어메시지의 보안성 있는 전송) 가 중요한 이슈로 대두되고 있다. 본 논문에서는 fault/attack을 관리하기 위해 광 소자들과 공통된 위험 요소를 포함하는 소자들을 분류하고, SRLG (Shared Risk Link Group)를 고려한 경로 설립 스킴과 GMPLS의 RSVP-TE+(Reservation Protocol-Traffic Engineering Extension)와 LMP(Link Management Protocol)의 보안성 제공 메커 니즘을 제안하여, OVPN에서의 생존성을 보장한다. 끝으로 시뮬레이션 결과를 통하여 제안된 알고리즘이 망 생존성을 위하여 더욱 효율적임을 증명하였다.

EMTP를 이용한 광 복합 지중송전케이블 광 유니트 금속관의 시스템 영향분석 (Analysis on System Effects of SUS Tube in Optical Fiber Composite Power Cable Systems Using EMTP)

  • 정채균;장태인;강지원
    • 전기학회논문지
    • /
    • 제63권9호
    • /
    • pp.1180-1185
    • /
    • 2014
  • This paper describes the effects on SUS tube of power optical fiber composite cable on underground transmission lines. The effects on grounding, air gap between SUS tube and metal sheath, contact resistance between outer semi-conducting layer and metal sheath and grounding of SUS tube application or not are variously analysed using EMTP in normal operating condition as well as single line to ground fault. From these results, in this paper, the scheme for protecting the electrically abnormal phenomena will be established on power-optical fiber composite cable of underground transmission lines. This paper can contribute to specification of grounding reference of SUS tube of optical fiber composite power cable system.