Efficient Test Techniques for Submarine Cable Repair

해저광케이블 수리를 위한 효율적인 탐지 및 측정 기법

  • 이영선 (전남대학교 전자통신공학과) ;
  • 정재진 (전남대학교 전자통신공학과) ;
  • 신현식 (전남대학교 전자통신공학과)
  • Received : 2008.01.14
  • Accepted : 2008.02.27
  • Published : 2008.03.30

Abstract

Submarine cable is the most important IT infrastructure for international communication across oceans. However, a cable fault rarely happens by ship's anchor, fishing gears, submarine earthquake, and so on, and we need to improve on repair time for the reducing expenses of cable repair ship as well as the stability of high-capacity submarine optical network. There are several kinds of cable faults such as Shunt fault, Cable cut, Open fault and Fiber break. When a fault is occurred, cable landing stations(CLS) have to analysis failure quickly and accurately to find the type and the location of a cable fault. During the repair period, CLS should swiftly perform the tests requested by cable repair ship. In order to make rapid progress on cable repair, CLS test technique is very important. So, in order to reduce the repair time, this paper is studying the CLS test techniques of locating a submarine cable fault and of checking the splicing point performed by cable repair ship.

해저광케이블은 국제통신의 98% 이상을 처리하고 있는 국가의 중요한 정보통신 인프라이다. 하지만 선박의 닻, 어선의 어구, 해저 지진 등 다양한 요인으로 인해 고장이 발생하며, 고장 발생시 대용량 해저통신 트래픽의 영향을 최소화하고, 케이블 수리 선박의 운영비용 절감을 위해서 수리 기간을 최대한 단축해야 한다. 해저광케이블 고장 유형은 Shunt Fault, Cable Cut, Open Fault, Fiber Break 등 여러 유형이 있으며, 고장이 발생하면 육상 터미널 국사(육양국)에서 정확하고 신속하게 고장 유형 및 고장 지점을 파악하고, 케이블 수리 선박은 수리 현장으로 출동하여 수리 작업을 수행하게 된다. 수리작업 기간 중 육양국에서는 케이블 수리 선박에서 요청하는 각종 Test를 수행하게 되며, 이때 육양국 Test 기법은 매우 중요하다. 본 논문에서는 해저광케이블 고장 유형 및 고장 지점 탐지 기법을 제시하고, 해저광케이블 수리기간 단축을 위한 육양국 Test 기법을 고찰하고자 한다.

Keywords