• 제목/요약/키워드: Optic Lens

검색결과 100건 처리시간 0.02초

Effect of Lu3Al5O12:Ce3+ and (Sr,Ca)AlSiN3:Eu2+ Phosphor Content on Glass Conversion Lens for High-Power White LED

  • Lee, Hyo-Sung;Hwang, Jong Hee;Lim, Tae-Young;Kim, Jin-Ho;Jeon, Dae-Woo;Jung, Hyun-Suk;Lee, Mi Jai
    • 한국세라믹학회지
    • /
    • 제52권4호
    • /
    • pp.229-233
    • /
    • 2015
  • Currently, the majority of commercial white LEDs are phosphor converted LEDs made of a blue-emitting chip and YAG yellow phosphor dispersed in organic silicone. However, silicone in high-power devices results in long-term performance problems such as reacting with water, color transition, and shrinkage by heat. Additionally, yellow phosphor is not applicable to warm white LEDs that require a low CCT and high CRI. To solve these problems, mixing of green phosphor, red phosphor and glass, which are stable in high temperatures, is common a production method for high-power warm white LEDs. In this study, we fabricated conversion lenses with LUAG green phosphor, SCASN red phosphor and low-softening point glass for high-power warm white LEDs. Conversion lenses can be well controlled through the phosphor content and heat treatment temperature. Therefore, when the green phosphor content was increased, the CRI and luminance efficiency gradually intensified. Moreover, using high heat treatment temperatures, the fabricated conversion lenses had a high CRI and low luminance efficiency. Thus, the fabricated conversion lenses with green and red phosphor below 90 wt% and 10 wt% with a sintering temperature of $500^{\circ}C$ had the best optical properties. The measured values for the CCT, CRI and luminance efficiency were 3200 K, 80, and 85 lm/w.

콘택트렌즈의 물리화학적 특성에 따른 라이소자임과 알부민의 흡착 특성 (Adsorption Properties of the Lysozyme and Albumin with Physicochemical Properties of the Contact Lens)

  • 성유진;유근창;전진
    • 한국안광학회지
    • /
    • 제18권3호
    • /
    • pp.261-270
    • /
    • 2013
  • 목적: FDA 기준에 의해 분류된 시판용 콘택트렌즈와 실험실에서 제조한 콘택트렌즈의 물리화학적 특성에 따라 라이소자임과 알부민의 흡착 특성을 살펴보고자 한다. 방법: 실험실에서 제조한 렌즈는 HEMA(2-hydroxyethyl methacrylate)와 TRIM(3-(trimethoxysilyl) propyl methacrylate) 등의 모노머를 사용하였으며 캐스트몰드 방법으로 제조하였다. 라이소자임과 알부민을 함유한 인공눈물을 제조하였다. 각각의 렌즈에 대해 흡착시간(48시간)과 인공눈물의 pH(pH 6, 6.8, 7.4, 8.2, 9)에 따라 단백질 흡착량 변화를 추적하고, 콘택트렌즈에 흡착된 각각의 단백질은 HPLC로 정량하였다. 결과: 두 단백질의 흡착에 대한 평형상태 도달하는 시간은 하이드로겔 렌즈에 비해 실리콘하이드로겔 렌즈에서 더 오래 걸렸다. 평형상태에서 두 단백질에 대한 흡착량은 실리콘하이드로겔 렌즈에 비해 하이드로겔 렌즈, 비이온성 렌즈에 비해 이온성 렌즈에서 높게 나타났다. 또한, 고함수 렌즈에서는 라이소자임이, 저함수 렌즈에서는 알부민의 흡착량이 많았으며, 이온성 고함수의 Group IV 하이드로겔 렌즈(H4)에서는 라이소자임만이 흡착되었다. 인공눈물의 pH에 따른 두 단백질의 흡착량은 각 단백질의 등전점에 가까워질수록 증가하였다. 결론: 라이소자임의 흡착량은 콘택트렌즈의 함수율보다는 렌즈 표면의 이온성에 더 큰 영향을 받으며, 알부민은 렌즈 표면의 이온성보다 함수율에 더 많은 영향을 받는다. 실리콘하이드로겔 렌즈에서 단백질의 흡착은 콘택트렌즈의 극성뿐만 아니라 실리콘 모노머에 포함된 Si 원자수와 그 화학적 구조에 의해 결정되는 세공의 크기 등이 함께 고려되어야 한다.

백색 LED용 저 연화점 유리를 이용한 색 변환 렌즈의 제조 조건에 따른 광 특성 (Optical Properties as Process Condition of Color Conversion Lens Using Low-softening Point Glass for White LED)

  • 채유진;이미재;황종희;임태영;김진호;정희석;이영식;김득중
    • 한국세라믹학회지
    • /
    • 제50권6호
    • /
    • pp.454-459
    • /
    • 2013
  • Recently, remote phosphors have been reported for application to white LEDs to provide enhanced phosphor efficiency compared with conventional phosphor-based white LEDs. In this study, a remote phosphor was produced by coating via screen printing on a glass substrate with different numbers of phosphor coating. The paste consists of phosphor, lowest softening glass frits, and organic binders. The remote phosphor could be well controlled by varying the phosphor content rated paste. After mounting the remote phosphor on top of a blue LED chip, CCT, CRI, and luminance efficiency were measured and values of 5300 K, 62, and 117 lm/W were respectively obtained in the 80 wt% phosphor with 3 coating layers sintered at $800^{\circ}C$.

적외선 광학 소재의 초정밀 선삭가공시 발생하는 미세균열 연구 (Micro-Crack Analysis from Ultra-Precision Diamond Turning of IR Optic Material)

  • 정병준;김건희;명태식;정의식;최환진;여인주;전민우
    • 한국정밀공학회지
    • /
    • 제33권11호
    • /
    • pp.905-910
    • /
    • 2016
  • Infrared (IR) optic lens can be fabricated by a single point diamond turning (SPDT) machine without subsequent polishing process. However, this machining process often leaves micro-cracks that deteriorate the surface quality. In this work, we propose an experimental design to remove micro-cracks on IR lens. The proposed design gathered data between cutting process condition and Rt surface roughness. This is of great importance because the scale of micro-cracks is a few micrometer. Rt surface roughness is suitable for analyzing maximum peak height signals of the profile. The experimental results indicate that feed per revolution variable is one of the most dominant variable, affecting the generation micro-cracks on IR lens surfaces.

광학렌즈의 사출압축성형에서 오버플로우를 이용한 웰드라인과 복굴절 저감 (Reduction of Birefringence and Weld-Line using Over-Flow in Injection Compression Molding for Optic Lens)

  • 공기환;이진효;강병욱;곽태수
    • 한국기계가공학회지
    • /
    • 제17권1호
    • /
    • pp.95-100
    • /
    • 2018
  • This study has focused on the weld-line and birefringence reduction of a plastic optic lens using over and CAE analysis in injection compression molding. A concave lens, which has a thin thickness in the center and a large difference in thickness between the center and the periphery, often causes weld-line defects during injection molding. CAE analysis has been applied to optimize the overflow design in order to reduce the weld-line defects and the polarization defects. To reduce the weld line and birefringence defects, overflow design and application using CAE analysis show that the measured birefringence values of the specimens before the overflow application were 46.8nm and 36.9nm, and the values after the over-flow application were 13.6nm and 14.0nm. From the experimental results, it is confirmed that birefringence is greatly improved when overflow is applied.

전자빔조사에 의한 HEMA의 중합과 소프트콘택트렌즈 제조 (Polymerization of HEMA by Electron beam Irradiation and Fabrication of Soft contact lens)

  • 황광하;신중혁;성유진;정근승;전진
    • 한국안광학회지
    • /
    • 제17권2호
    • /
    • pp.135-141
    • /
    • 2012
  • 목적: 전자빔(electron beam)을 이용한 HEMA(2-hydroxyethyl methacrylate)의 중합과정에 대한 최적의 전자빔조사(irradiation) 조건을 살펴보고, 전자빔과 일반적인 열중합 방법에 의해 제조된 콘택트렌즈의 물리적 특성을 각각 비교함으로써 콘택트렌즈 제조에 전자빔조사 방법의 활용가능성을 알아보고자 한다. 방법: 중합에 사용된 모노머(monomer)나 첨가제의 구성비 그리고 전자빔흡수선량(0~120 kGy)에 따라 HEMA의 중합정도를 관찰하여 전자빔조사(irradiation)에 의한 중합여부와 최적의 중합조건을 제시하였다. 동일한 반응물 구성비에 대해 전자빔과 열중합의 두 가지 다른 중합방법을 이용하여 고분자를 합성하였다. 각각의 고분자로부터 제조된 소프트콘택트렌즈에 대해 함수율, 산소전달률(Dk/t), 광투과율 등의 물리화학적 특성을 FT-IR 결과를 이용하여 비교 분석하였다. 결과: 전자빔조사선량(0~120 kGy)에 따라 살펴본 HEMA의 중합률은 100 kGy 이상에서 99% 이상으로 나타났으며, 사용된 모노머의 구성비나 광개시제와 가교제 등의 첨가에 무관하게 높은 중합률을 보였다. 전자빔 조사에 의해 제조된 렌즈의 함수율은 열중합 방법에 의해 제작된 렌즈에 비해 10% 이상 높게 나타났다. 산소전달률(Dk/t)도 함수율과 마찬가지로 전자빔조사방법에 의해 제조된 렌즈에서 더 높게 나타났으며, 순수한 HEMA의 경우는 약 2배 정도 높은 값을 보였다. FT-IR 분석결과, 전자빔 조사방법에 의해 제조한 렌즈에서 친수성 증가와 관계되는 OH group의 농도가 증가하였고 이에 따른 분자간 수소결합의 농도가 증가함을 확인하였다. 두 가지 다른 중합방법에 의해 제조된 렌즈의 가시광선(380~800 nm) 영역에서 광 투과율은 제조방법과는 상관없이 유사하였으며, 90% 이상의 높은 값을 나타내었다. 결론: HEMA를 기본으로 구성된 다양한 반응혼합물과 개시제나 가교제의 첨가가 없는 순수한 HEMA에 100kGy 이상의 전자빔을 조사할 경우 중합이 성공적으로 이루어졌다. 또한 순수한 HEMA에 100kGy의 전자빔을 조사하여 중합된 고분자로부터 제조된 콘택트렌즈에서 가장 높은 함수율과 산소전달률을 나타내어 전자빔조사조건에 따라 물리적특성이 다른 콘택트렌즈의 제조가 가능함을 확인하였다.

볼렌즈를 이용한 광학식 진직도 측정시스템 (Optical Straightness Measuring System Using a Ball-lens)

  • 이민호;조남규
    • 한국정밀공학회지
    • /
    • 제31권12호
    • /
    • pp.1133-1139
    • /
    • 2014
  • This paper proposes a simple method to improve a sensitivity of a straightness measurement system for a linear stage, which is applied to a system based on a geometric optic method. An optical system for this method is composed of a corner-cube retro-reflector, a ball-lens and a twodimensional position sensitive detector (2D PSD). The effectiveness of the proposed method was examined theoretically, and verified experimentally using a prototype measurement system. The results show that the measuring sensitivity was dependent on the size of the ball-lens and the setup position of PSD from the ball-lens, and that the proposed method is efficient method to improve the measuring sensitivity.

전반사 렌즈를 이용한 LED 등명기 광학계 설계 (A Optical System Design of LED Marine Lanterns Based on a TIR Collimator Lens)

  • 고동현;이윤철
    • 조명전기설비학회논문지
    • /
    • 제29권11호
    • /
    • pp.1-5
    • /
    • 2015
  • In this paper, we propose the optical system design for a medium sized LED marine lanterns which simplifies the multi-layer structure into a single structure. In order to satisfy the target fixed intensity(35,000cd) and vertical divergence($-2.5^{\circ}{\sim}-4.0^{\circ}$, $+2.5^{\circ}{\sim}+4.0^{\circ}$), we use the total internal reflection collimator lens. And a Monte Carlo simulation has been utilized to optimize a condition of a LED package, TIR lens and outside lens. The computer simulation results indicated that this LED marine lanterns can produce of a fixed intensity(35,382cd) and vertical divergence($-3.1^{\circ}{\sim}+2.5^{\circ}$). Using the this optical system, we achieve the target value of LED lanterns.

칼라필터 렌즈(ChromaGenTM)를 이용한 읽기능력 향상에 대한 임상연구 (The Study on Improvement of Reading Ability for Dyslexia Wearing Color filter lens (ChromaGenTM Lens))

  • 이석주;박지훈;이소희;황광하;유근창
    • 한국안광학회지
    • /
    • 제16권1호
    • /
    • pp.65-74
    • /
    • 2011
  • 목적: 본 연구는 시각적 난독증 증상을 나타내는 호소군을 대상으로 칼라필터렌즈인 크로마젠($ChromaGen^{TM}$)렌즈를 착용함으로써 읽기능력의 향상정도를 알아보고자 하였다. 방법: 설문을 통한 난독증 의심 학생 52명을 대상으로 윌킨스 독서속도검사법을 이용하여 난독증 교정렌즈인 크로마젠 렌즈를 착용 전과 후 그리고 3개월 동안 착용한 후 읽기능력의 향상정도를 알아보았다. 결과: 1분 동안의 읽은 단어 숫자는 크로마젠 렌즈 착용자가 평균 110.26${\pm}$22.07 단어를 읽었고, 나안 또는 교정안경 착용자는 평균 106.42${\pm}$22.70의 단어를 읽었다. 크로마젠 렌즈 3개월 착용 후에는 평균 114.16${\pm}$21.86 단어를 읽었고, 나안 또는 교정안경을 착용한 학생은 109.96${\pm}$21.67 단어를 읽었다. 크로마젠 렌즈 착용 전과 후에 대한 3개월 동안 크로마젠 렌즈를 착용한 후의 읽기능력은 각각 3.70%${\pm}$0.29(p=0.01, t=2.26), 4.50%${\pm}$0.10(p=0.01, t=2.78)의 향상을 보였으며 통계학적 유의성이 있었다(p<0.05). 크로마젠 렌즈의 교정 3개월 후 난독증 증상의 개선에 대한 만족도 조사에서 전체 대상자 중 88.4%가 크로마젠 렌즈에 의해 난독증 증상이 개선되었다고 답하였다. 결론: 시각적 난독증의 증상이 의심되는 대상자에게 난독증 교정안경렌즈인 크로마젠 렌즈는 읽기능력 향상에 효과가 있었으며 통계학적으로 유의성이 있었다(p<0.05).