• Title/Summary/Keyword: Operational Phase

Search Result 448, Processing Time 0.025 seconds

Characteristics of Two Phase Operation of Two Winding Motor Driven by Reference Current Adaptive Inverter (기준전류추정형 인버어터에 의한 2 권선전동기의 2 상운전특성)

  • 원종수;정의상
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.33 no.8
    • /
    • pp.289-298
    • /
    • 1984
  • The single phase induction motor is recently requested to meet a broad speed control and smooth forward and reverse operation due to the multifarious usages. This paper deals with two phase operation of a two winding motor by reference current adaptive inverter which can supply the currents to satisfy the balanced oeration into the main and auxiliary winding through the entire operational region. According to the roposed system, the starting, forward and reverse and variable speed control of a two winding motor eliminated the capacitor from the capacitor-run motor is also possible. The formation and its principle of the reference current adaptive inverter and characteristic analysis of the motor fed by this apparatus are described in this paper. Excellent agreement with the measured results and calculated values by computer simulation is obtained.

  • PDF

A Design of Phase-Shifted FB-ZVS PWM Converter for Driving Magnetron and Its Average Anode Current Controller

  • Lee Wan-Yun;Chung Gyo-Bum;Shin Pan-Seok
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.140-145
    • /
    • 2001
  • This paper proposes to use a 20[kHz] phase­shifted Full-Bridge (FB) Zero-Voltage-Switched (ZVS) PWM converter in order to drive a 600[W] magnetron, and analyzes the operational modes in a switching period. Additionally, the controller of the average anode current is designed. Simulation studies and experiments verify that the proposed converter and the average anode current controller shows good performance to drive the magnetron.

  • PDF

Repair-Replacement Strategies for Warranted Items with Phase-Type Lifetimes (PH 수명분포를 갖는 보증제품의 수리-교체 전략)

  • Kim, Ho-Gyun;Rao, B. Madhu;Bae, Chang-Ok;Kim, Seung-Chul
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.31 no.4
    • /
    • pp.341-348
    • /
    • 2005
  • This paper is concerned with the question of servicing warranties for repairable items. During the warranty period, each time an item fails the manufacturer has the obligation to restore the item to operational condition either by repairing the item or by replacing it with a new item. In this paper, we consider repair-replacement strategies based on the condition of the failed item. For products with phase-type lifetime distributions where the phases represent the condition of the item, we develop algorithms to determine the expected cost of servicing a warranty and use it in making the repair-replacement decision. Illustrative numerical examples are presented. We also propose a dynamic strategy by taking the expected remaining warranty cost into consideration.

Warranty Servicing Cost Analysis Using Phase-Type Lifetime Distributions (Phase-Type 분포를 이용한 보증서비스 비용 분석)

  • 김호균;백천현;조형수
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.25 no.3
    • /
    • pp.41-48
    • /
    • 2000
  • We consider the question of warranties for repairable items. During the warranty period, each time an item fails the manufacturer has the obligation to restore the item to operational condition either by repairing the item or by replacing it by a new item. In this paper, we consider a warranty policy for making this decision based on the condition of the failed item. For products with phase-type lifetime distributions where the phases represent the condition of the item, we develop algorithms to determine the expected cost of servicing a warranty and use it in making the repair/replacement decision. illustrative numerical examples are presented.

  • PDF

Simulation of the Three-Phase Modified Bridge Tyne Fault Current Limiter for Simplified Power System (삼상 변형 브리지 형태 한류기의 단순계통적용 시뮬레이션)

  • 이응로;이승제;이찬주;김태중;고태국
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2001.02a
    • /
    • pp.68-71
    • /
    • 2001
  • This paper deals with the operational characteristics of the three-phase modified bridge type fault current limiter(FCL) for 3.3kV/200A power system. This is a preliminary step to develop the FCL's faculties for an application to high voltage transmission line. A three-phase modified bridge type FCL consists of transformers, diodes, and a high-Tc superconducting coil. As the results of simulations, when the FCL of 1.5H inductance was installed in the power system. the fault current was reduced to be about 90% of that without FCL.

  • PDF

A novel 622Mbps burst mode CDR circuit using two-loop switching

  • Han, Pyung-Su;Lee, Cheon-Oh;Park, Woo-Young
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.3 no.4
    • /
    • pp.188-193
    • /
    • 2003
  • This paper describes a novel burst-mode clock and data recovery (CDR) circuit which can be used for 622Mbps burst mode applications. The CDR circuit is basically a phase locked loop (PLL) having two phase detectors (PDs), one for the reference clock and the other for the NRZ data, whose operations are controlled by an external control signal. This CDR was fabricated in a 1-poly 5-metal $0.25{\;}\mu\textrm{m}$ CMOS technology. Jitter generation, burst/continuous mode data receptions were tested. Operational frequency range is 320Mhz~720Mhz and BER is less than 1e-12 for PRBS31 at 622Mhz. For the same data sequence, the extracted clock jitter is less than 8ps rms. Power consumption of 100mW was measured without I/O circuits.

An investigation of LPG fuel supply method for Liquid phase LPG injection system (LP가스연료 액상공급시스템 특성연구)

  • Kim, C.U.;Oh, S.M.;Choi, S.J.;Kang, K.Y.
    • Journal of ILASS-Korea
    • /
    • v.9 no.2
    • /
    • pp.18-23
    • /
    • 2004
  • An experimental studies of conventional gasoline fuel pump were carried out to obtain fundamental data fur liquid phase LPG injection(LPLi) system. A regenerative type and a roller-vane type of pumps were investigated in various operational condition. The experiments were performed to obtain flow rate of LPG fuel as a function of pressure differences and temperatures. The regenerative pump had too low flow rate at some experimental conditions to use this pump system for LPLi fuel supply system. On the other hand, the roller-vane type pump can be applied to the system only if its check valve is modified. Cavitation might occur in this system which can result in system noise, flow rate variation, and pump durability problem. To solve these problems the system is needed to increase $NPSH_{re}$(required net positive suction head).

  • PDF

A Dependability Modeling of Software Under Memory Faults for Digital System in Nuclear Power Plants

  • Park, Jong-Gyun;Seong, Poong-Hyun
    • Nuclear Engineering and Technology
    • /
    • v.29 no.6
    • /
    • pp.433-443
    • /
    • 1997
  • In this work, an analytic approach to the dependability of software in the operational phase is suggested with special attention to the hardware fault effects on the software behavior : The hardware faults considered are memory faults and the dependability measure in question is the reliability. The model is based on the simple reliability theory and the graph theory which represents the software with graph composed of nodes and arcs. Through proper transformation, the graph can be reduced to a simple two-node graph and the software reliability is derived from this graph. Using this model, we predict the reliability of an application software in the digital system (ILS) in the nuclear power plant and show the sensitivity of the software reliability to the major physical parameters which affect the software failure in the normal operation phase. We also found that the effects of the hardware faults on the software failure should be considered for predicting the software dependability accurately in operation phase, especially for the software which is executed frequently. This modeling method is particularly attractive for the medium size programs such as the microprocessor-based nuclear safety logic program.

  • PDF

Voltage Oscillation Reduction Technique for Phase Shift Full Bridge Converter (위상 천이 풀 브릿지 컨버터를 위한 전압 진동 제거 기술)

  • Park, Ki-Bum;Kim, Chong-Eun;Moon, Gun-Woo;Youn, Myung-Joong
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.286-288
    • /
    • 2005
  • Conventional phase shift full bridge (PSFB) converter has serious voltage oscillation problem across the secondary rectifier diodes, which would require the dissipate snubber circuit, thus degrades the overall efficiency. To overcome this problem, a new voltage oscillation reduction technique (VORT) which effectively reduce the voltage oscillation of the secondary rectifier diodes for phase shift 1011 bridge converter is proposed. Therefore, no dissipate snubber for rectifier diodes is needed. In addition, since it has wide zero voltage switching (ZVS) range, high efficiency can be achieved. Operational principle, analysis of voltage oscillation, and design consideration are presented compare with that of the conventional PSFB converter. To confirm the validity of the proposed VORT, experimental results from a 420W, 385Vdc/210Vdc prototype are presented.

  • PDF

A Novel Control Strategy for a Three-Phase Rectifier with High Power Factor and Stable Output Voltage

  • Lee, Hong-Hee;Phan, Van-Tung;Sergey, Brovanov;Chun, Tae-Won
    • Journal of Power Electronics
    • /
    • v.7 no.3
    • /
    • pp.203-212
    • /
    • 2007
  • In this paper, a proposed approach to improve the power factor of three-phase rectifiers and to stabilize the output voltage against load change is presented. The elements of the given control strategy are small size, low cost, high performance, and simplicity. The proposed control strategy of switches is based on a prototype of three bi-directional switched consisting of four diodes and one IGBT. A control technique and operational procedure are also developed, both theoretically and experimentally. The experimental results clearly verify the theoretical analysis from the prototype connected to grid unity.