• Title/Summary/Keyword: Operation room fire

Search Result 38, Processing Time 0.023 seconds

Smoke Control Experiment of a Very Deep Underground Station Where Platform Screen Doors are Installed (I) - Analysis on Smoke Control Performance on the Platform (스크린도어가 설치된 대심도 지하역사의 제연 실험 I - 승강장에서의 제연의 효과 분석)

  • Park, Won-Hee;Kim, Chang-Yong;Cho, Youngmin;Kwon, Tae-Soon;Lee, Duck-Hee
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.8 no.7
    • /
    • pp.485-496
    • /
    • 2018
  • In this paper, the smoke behavior in an underground station on operation of the fans in the ventiliation of the station was measured by the experimental method when the fire occurred in the underground station platform where the platfrom screen door was installed. The ventilation characteristics were compared when the ventilation system was operated and when the ventilation system was not operated when a fire occurred at the platform where the clean door was closed. To simulate the fire smoke, the smoke generated from the smoke generator was heated using a hot air fan. The transmittance was measured using a smoke density meter to quantitatively measure fire smoke. If the screen door is closed and the ventilation system of the underground station does not work, it is confirmed that if a fire occurs in the platform, smoke accumulates inside the platform, evacuating passengers is very difficult and can lead to a very dangerous situation. On the other hand, under the condition that the ventilation facility of the subway station is operated, the smoke evacuates to the outside through the ventilation facility of the underground station, and airflow is formed in the direction from the waiting room to the waiting area, so that the passenger located on the platform can safely evacuate toward the concourse. In the following paper, we will discuss the concurrent effect of tunnel ventilation through tunnel vent near the platform.

Principal Component Analysis on Marine Casualties Occurred at Korean Littoral Sea in Recent 5 Years (최근 5년간 국내 연근해에서 발생한 해양사고에 대한 주성분분석)

  • KIM, Yeong-Sik
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.28 no.2
    • /
    • pp.465-472
    • /
    • 2016
  • Principal Component Analysis (PCA) is useful statistical technique for finding patterns in data, and expressing the data in such a way as to highlight their similarities and differences. In this paper, 1417 marine casualties occurred in Korean littoral sea in recent 5 years, were examined by the PCA. The main results obtained were as follows : 1. Most of marine casualties resulted from the human factors such as careless operation and insufficient engine maintenance. 2. Collision and standing mainly resulted from steering room-related human factors such as careless guard, inadequate ship-handling, however engine damage and fire explosion mainly resulted from engine room-related human factor such as bad handling of engine system. 3. No. 1 principal component represents accident frequency, No. 2 principal component represents the cause and No. 3 principal component represents the pattern of marine casualties, respectively.

Insulation Characteristics for a Conduction-Cooled HTS SMES

  • Cheon H.G.;Baek S.M.;Seong K.C.;Kim H.J;Kim S.H.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.7 no.2
    • /
    • pp.39-43
    • /
    • 2005
  • Toward the practical applications, on operation of conduction-cooled HTS SMES at temperatures well below 77 K should be investigated, in order to take advantage of a greater critical current density of HTS and considerably reduce the size and weight of the system. Recently, research and development concerning application of the conduction-cooled HTS SMES that is easily movement are actively progressing in Korea. Electrical insulation under cryogenic temperature is a key and an important element in the application of this apparatus. However, the behaviors of insulators for cryogenic conditions in air or vacuum are virtually unknown. Therefore, this work focuses on the breakdown and flashover phenomenology of dielectrics exposed in vacuum for temperatures ranging from room temperature to cryogenic temperature. Firstly, we summary the insulation factors of the magnet for HTS SMES. And a surface flashover as well as volume breakdown in air and vacuum has been investigated with two kind insulators. Finally, we will discuss applications for the HTS SMES including aging studies on model coils exposed in vacuum at cryogenic temperature.

A Study on ground fault at low voltage line and apparatus in urban railway station (도시철도역사의 저압선로 및 기기에서의 지락사고 방지 방안에 관한 검토)

  • Min Kyung-Yun;Kim Jin-Ho;Han Hag-Su
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.699-704
    • /
    • 2005
  • In the station of the railway and the subway various illumination equipment and a general power equipment for a passenger convenience, the signal equipment and the communication equipment which is necessary to the train operation provided. At the all of like this equipment from the electric room which is established in each station by changing from high voltage to low voltage and it supplies from the illumination transformer, the power transformer and the signal transformer. If it supplies to the equipment from the high voltage to the low voltage, it must be established to contact protection device in between the high voltage coil and the low voltage coil. Also it must do the grounding faulting device at the low voltage lines, the earthing devices at apparatus for the protection of an electric shock and an electric fire by the electric relation law. Compared the related regulations between the facilities which require protective functions such as grounding fault or earthing in public utilities like subway stations, and the facilities which do not require line earthing or protective functions such as electricity supplied for signalling the train. Also, will describe a countermeasure for the accident from a grounding fault.

  • PDF

A Study on the Consciousness of Fare-fighting Officers for the Establishment and Pevitalization of Integrated Disaster Management System (통합재난관리체계 구축 및 활성화를 위한 소방공무원 의식조사 연구)

  • Bae, Young-Son;Koo, Won-Hoi;Shin, Ho-Joon;Baek, Min-Ho
    • Journal of the Society of Disaster Information
    • /
    • v.10 no.1
    • /
    • pp.151-158
    • /
    • 2014
  • In this study, the problems in the domestic disaster management system were identified through the examination of the system, relevant implications were drawn through the present status of domestic integrated disaster management system, and the consciousness survey for the integrated disaster management system targeting fire-fighting officers in the front line of the disaster was carried out to identify the measures to improve the system. Based on the findings, the measures to establish and revitalize the integrated disaster management system was presented, and the contents of the measures are as follows. In order to establish and revitalize the integrated disaster management system, the following measures should be prepared for each item. In the organizational aspect, the coordination system between government agencies should be established properly and the relevant information should he shared and delivered smoothly. In the legal and institutional aspect, the improvement is required to prevent any miscommunications in the coordination and joint operation plan through the collaboration between government agencies should be established in consideration of characteristics of each government agency. Also, in the aspect of system, the equipment should be maintained and updated continuously in order to respond to rapidly changing disasters and the organization, laws, institutions and system should be improved systematically and harmoniously. And, the detailed measures appropriate for the characteristics of domestic disasters should be prepared through the examination of advantages and disadvantages of integrated disaster management system in advanced countries in details and the detailed plans for the establishment of integrated situation management system in relevant organizations and the unification of situation room through the establishment of efficient integrated management system should be established.

An Improvement in Level of Facility Security Operation (시설보안 운영수준 향상방안)

  • Chung, Tae-Hwang;Chang, Hang-Bae
    • Korean Security Journal
    • /
    • no.32
    • /
    • pp.205-225
    • /
    • 2012
  • This study is to present an improvement of facility security through the evaluation of facility security operation level. To fulfill the purpose of the study, a survey of some facilities was conducted and the result was analyzed as follows; First, although security personnels were deployed in the facilities, the level of security personnel operation was relatively low. Second, job education training level was relatively proper, that is relevant to the result that show the level of service mind and the working mind of security personnel were proper, also relevant to the relatively good work shift system. Third, although situation room was operated well, the level of restricted area set-up and access control of visitor were low, and the level of article inspection and vehicle access control were very low. Forth, the level of security manual application that include detailed security method and procedure was proper. But accident prevention and response manual application was lower than security manual application, that show preparation for fire and negligent-accident is passive. For the improvement of facility security, the high level part and low level part in the survey result could be merged. For example, we could specify factors that show low level in the survey such as security personnel operation, access control of visitor and vehicle, article inspection, accident prevention and response in the security manual and promote education circumstance that show high level.

  • PDF

A Study on the Analysis of Bus Machine Learning in Changwon City Using VIMS and DTG Data (VIMS와 DTG 데이터를 이용한 창원시 시내버스 머신러닝 분석 연구)

  • Park, Jiyang;Jeong, Jaehwan;Yoon, Jinsu;Kim, Sungchul;Kim, Jiyeon;Lee, Hosang;Ryu, Ikhui;Gwon, Yeongmun
    • Journal of Auto-vehicle Safety Association
    • /
    • v.14 no.1
    • /
    • pp.26-31
    • /
    • 2022
  • Changwon City has the second highest accident rate with 79.6 according to the city bus accident rate. In fact, 250,000 people use the city bus a day in Changwon, The number of accidents is increasing gradually. In addition, a recent fire accident occurred in the engine room of a city bus (CNG) in Changwon, which has gradually expanded the public's anxiety. In the case of business vehicles, the government conducts inspections with a short inspection cycle for the purpose of periodic safety inspections, etc., but it is not in the monitoring stage. In the case of city buses, the operation records are monitored using Digital Tacho Graph (DTG). As such, driving records, methods, etc. are continuously monitored, but inspections are conducted every six months to ascertain the safety and performance of automobiles. It is difficult to identify real-time information on automobile safety. Therefore, in this study, individual automobile management solutions are presented through machine learning techniques of inspection results based on driving records or habits by linking DTG data and Vehicle Inspection Management System (VIMS) data for city buses in Changwon from 2019 to 2020.

The Research on the Life-safety Implementation using the Natural Light LED Lamp in the Disaster Prevention and Safety Management (방재안전 자연광 LED 조명을 이용한 생활안전 개선에 관한 연구)

  • Lee, Taeshik;Seok, Gumcheul;So, Yooseb;Choi, Byungshik;Kim, Jaekwon;Cho, Woncheol
    • Journal of Korean Society of Disaster and Security
    • /
    • v.9 no.2
    • /
    • pp.53-62
    • /
    • 2016
  • This paper is shown the new method using LED Light, which the light environment is upgraded the natural LED light in the area of Disaster Prevention and Safety Management (PDSD), which the events of deaths is reduced on the Suicide, the Infectious diseases, the safety accidents, the Traffic Accident, the crime, the fire, the Nature Disaster, and which the health and the environment and the safety is implemented using the value of the color LED Light. Research findings include,during 3 weeks in the November 2016, in the ten residents (average living 28.7 years, age 67.5 years) with depressive symptoms in the northern part of Seoul, according to the request of the user, the PDSD natural light LED lighting was installed in the home bedroom or the living room, expectations for the ability to restore physical and mental stability were high (88%), in the same way, after 1 week and 3 weeks, the physical and mental changes were compared and the results,84% in the first week and 90% in the third week and thereafter, the effect of relieving depression was high. We conclude that patients with depression have a good sleep, an uneasy feeling, a sense of security, a good night's sleep, and a good feeling. The PDSD LED Light is expected to contribute in the various areas, which reduced the suicides, which give increased immunity from infectious diseases, which give a crash to reduce accidents caused by negligence, which improve the safe operation of heavy vehicles in which a traffics accident incidence installed on the highest point, which improve the safety function on the 'safety way home' for the safety of the community, which due to fire gives alleviate the emotional anxiety of firefighters, which improve the environment for long-term control room working during decision making caused by natural disasters.