• 제목/요약/키워드: Operation Test

검색결과 5,184건 처리시간 0.037초

Design, Implementation, and Validation of KOMPSAT-2 Software Simulator

  • Lee, Sang-Uk;Lee, Byoung-Sun;Kim, Jae-Hoon;Cho, Sung-Ki
    • ETRI Journal
    • /
    • 제27권2호
    • /
    • pp.140-152
    • /
    • 2005
  • In this paper, we present design features, implementation, and validation of a satellite simulator subsystem for the Korea Multi-Purpose Satellite-2 (KOMPSAT-2). The satellite simulator subsystem is implemented on a personal computer to minimize costs and trouble on embedding onboard flight software into the simulator. An object-oriented design methodology is employed to maximize software reusability. Also, instead of a high-cost commercial database, XML is used for the manipulation of spacecraft characteristics data, telecommand, telemetry, and simulation data. The KOMPSAT-2 satellite simulator subsystem is validated by various simulations for autonomous onboard launch and early orbit phase operations, anomaly operation, and science fine mode operation. It is also officially verified by successfully passing various tests such as the satellite simulator subsystem test, mission control element system integration test, interface test, site installation test, and acceptance test.

  • PDF

단락발전기 용 여자장치의 조작과 기능에 대한 고찰 (The study for function and operation of the excitation equipment for short circuit generator)

  • 김선구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.735-736
    • /
    • 2008
  • There are many equipments for the Short Circuit Test, for example Short Circuit Generator, Induction Motor, Sequence Timer, CLR, Back Up Breaker, Making Switch and Excitation Equipment etc. Gradually an allowable tolerance of the short circuit test voltage is become smaller by the standards for short circuit test. The excitation equipment of short circuit generator is very important for test voltage is adjusted by the excitation equipment. Especially the excitation equipment must be possessed character of exactitude, durability and inalterability because some times around 10,000 times opening and closing short circuit test is requested by clint, which must be done within one minute. The purpose of this study for function and operation of the excitation equipment which rated DC voltage is 1,000V, rated DC current is 300A, rated out put is 30kW and type is YNEX 97S-441/609, is to help operation of short circuit generator.

  • PDF

기어 물림 상태의 타행 주행 저항을 이용한 엔진 운전 조건의 분석 (Analysis of Engine Operation Condition by Using Coastdown Test under Gear Engaged Condition)

  • 심범주;박경석;박준수;민병두
    • 한국자동차공학회논문집
    • /
    • 제20권6호
    • /
    • pp.61-66
    • /
    • 2012
  • Conventional method to transform vehicle driving condition to engine operation mode is to use vehicle road load under neutral gear and mechanical efficiency of drivetrain. But this method requires additional measurement of efficiency of drivetrain on a test rig. And this measurement is normally done at fixed speed and thus estimated accuracy of engine operation mode is not considered to be high enough. This study suggests new method to calculate engine operation mode for prescribed driving mode such as NEDC using vehicle coastdown test under gear engaged condition without measurement of mechanical efficiency of drivetrain. Coastdown test was done under neutral and gear engaged condition for comparison and also trial to extract mechanical loss of drivetrain was carried out. Calculated engine torque by conventional and newly suggested method was compared with actually measured torque of a vehicle on a chassis dynamometer during NEDC. Newly suggested method showed slightly higher accuracy of accumulated brake work during NEDC.

발전소 터빈제어 밸브시험 계통 모델 개발 (Development of Process Model for Turbine Control Valve Test in a Power Plant)

  • 우주희;최인규;박두용;김종안
    • 전기학회논문지
    • /
    • 제60권4호
    • /
    • pp.830-837
    • /
    • 2011
  • A turbine control system which has been operated for years in a nuclear power plant was retrofitted with a newly developed digital control system. After completion of the retrofit, turbine valve tests were performed to ensure the integrity of each valve's control function. The sequence of each valve test is composed of a closing process and a reopening process. To minimize megawatt variation which normally occurs during the test sequence, we employed a kind of compensator algorithm in the new digital control system which also have been used in the old system. There were difficulties finding optimal parameter settings for our new compensator algorithm because the power plant didn't allow us to perform necessary tuning procedures while the turbine is on load operation. Therefore an alternative measure for the compensator tuning which is independent of the turbine actual operation had to be implemented. So, a process model for the test was required to overcome this situation. We analyzed the operation data of the test and implemented the process model by use of input and output variable relations. Also we verified the process model by use of another condition's operating data. The result shows that the output of model is similar to the actual operation data.

구개열 언어의 비음화에 관한 공기역학 및 음향학적 연구 (An Aerodynamic and Acoustic Study of Nasalization in Cleft Palate Speakers.)

  • 이종한;신효근
    • 음성과학
    • /
    • 제5권1호
    • /
    • pp.105-119
    • /
    • 1999
  • Cleft palate patients have general speech problems with resonance disorders and articulation disorders. The aim of this study is to find the aerodynamic and acoustic characteristics of the nasalization in cleft palate speakers. Thirteen control groups and three cleft palate patients pre- and post operation were selected for these studies. The test words are composed by polysyllabic words: consonants between high vowel /i/ analysis. The cleft palate patients repeated test words pre- and post-operation from one, three and six month periods. The subjects repeated test words on Macquirer and on Nasometer Model 6200-3. The aerodynamic and acoustic results of nasalization show as follows: (1) The nasal rate in overall airflow of aspirated consonant for cleft palate patients shows higher levels than that of the control group. It had decreased since one month after operation. (2) The overall airflow of cleft palate patients is higher than in the control group, however oral air pressure is lower than control group. (3) The nasal airflow and the nasal rate in overall airflow of cleft palate patients has higher than the control group, however its decreased after operation. (4) The nasalance scores of cleft palate patients were 40% higher than that of the control group. The scores did not decrease after operation. The nasalance score of lateral and fricative sounds did not decrease after operation.

  • PDF

ASIC의 BIST 할당을 위한 효과적인 BILBO 설계 (Design on the efficient BILBO for BIST allocation of ASIC)

  • 이강현
    • 전자공학회논문지C
    • /
    • 제34C권9호
    • /
    • pp.53-60
    • /
    • 1997
  • In this paper, an efficient BILBO(named EBILBO) is proposed for batch testing application when a BIST (built-in self test) circuit is implemented on ASIC. In a large and complex circuit, the proposed algorithm of batch testing has one pin-count that can easily control 4 test modes in the normal speed of circuit operation. For the implementation of the BIST cifcuit, the test patern needed is generated by PRTPG(pseudo-random test pattern generator) and the ouput is observed by proposed algorithm is easily modified, such as the modelling of test pattern genration, signature EBILBO area and performance of the implemented BIST are evaluated using ISCAS89 benchmark circuits. As a resutl, in a circuit above 600 gates, it is confirmed that test patterns are genrated flexibly about 500K as EBILBO area is 59%, and the range of fault coverage is from 88.3% to 100%. And the optimized operation frequency of EBILBO designed and the area are 50MHz and 150K respectively. On the BIST circit of the proposed batch testing, the test mode of EBILBO is able to execute as realtime that has te number of s$\^$+/n$\^$+/(2s/2p-1) clocks simultaneously with the normal mode of circuit operation. Also the proposed algorithm is made of the library with VHDL coding thus, it will be widely applied to DFT (design for testability) that satisfies the design and test field.

  • PDF

경계면스캔에서의 선택가능한 관측점 시험구조의 개발 (Development of selectable observation point test architecture in the Boundry Scan)

  • 이창희;장영식
    • 한국컴퓨터정보학회논문지
    • /
    • 제13권4호
    • /
    • pp.87-95
    • /
    • 2008
  • 경계면 스캔 구조는 시험대상회로의 출력 값들을 캡쳐하여 스캔경로를 이용하여 TDO로 직렬출력하여 출력 값을 관찰할 수 있는 시험구조이며, Sample/preload명령어를 이용하여 시험대상회로의 특정한 한 순간의 출력만을 캡쳐하여 직렬출력하여 분석할 수 있다. 본 논문에서는 4비트 비동기 카운터회로를 시험대상회로로 선정하고, 정상동작중인 카운터의 특정 출력을 지정하여 특정한 순간의 정적인 출력이 아닌, 연속적인 동적인 출력 값들을 다른 출력결과의 영향 없이 지속적으로 TDO로 출력하여 관찰할 수 있는 선택 가능한 관측점을 가진 시험구조와 시험절차를 개발하였다. 본 논문에서 제안하는 선택 가능한 관측점을 가진 시험구조는 표준에서 정한 시험동작을 정상적으로 수행하며, 관측점의 설정을 위한 명령어가 추가되었다. 4비트 카운터회로에 제안된 선택 가능한 관측점 시험구조를 적용 설계하고, 관측점 설정 명령어를 사용한 시험절차를 Altera의 Max 10.0을 이용한 시뮬레이션을 통해 동작의 정확성을 확인하였다.

  • PDF

척추마취 전립선절제술환자의 음악요법효과에 대한 융합연구 (Convergence study on Effects of Music Therapy in Patients Undergoing Prostatectomy with Spinal Anesthesia)

  • 이영은;김주성
    • 한국융합학회논문지
    • /
    • 제8권1호
    • /
    • pp.97-106
    • /
    • 2017
  • 본 융합연구의 목적은 척추마취하에서 전립선절제수술을 받는 환자의 불안, 피로 및 활력징후에 미치는 선호 음악요법의 효과를 확인하기 위함이다. 본 연구는 비동등성 대조군 전후시차설계에 따라 환자 45명을 대상으로 하였으며 실험군에게는 수술 중 선호하는 음악을 들려주었다. 자료는 수술 30분전, 수술 20분 경과, 수술 40분 경과, 및 마취회복실 입실직후에 구조화된 질문지와 직접 계측을 통해 수집하였으며 기술통계, ${\chi}^2-test$, Fisher's exact test, t-test 및 repeated measures ANOVA로 분석하였다. 연구결과 실험군의 불안과 피로수준은 대조군보다 유의하게 낮았다(p=.001; p=.020). 그러나 수축기혈압, 이완기혈압 및 맥박에서는 두 집단 간 유의한 차이가 없었다(p=.821; p=.473; p=.782). 이상의 연구결과를 통해 척추마취 전립선절제술을 시행하는 환자에게 수술 중 환자의 선호 음악요법을 제공하는 것은 수술 관련 불안과 피로를 완화하는 유용한 간호중재가 될 수 있음을 확인하였다.

동적 네트워크를 이용한 표면실장기 운영 평가 (The evaluation for the operation surface mounters using a dynamic network)

  • 이달상
    • 한국경영과학회:학술대회논문집
    • /
    • 대한산업공학회/한국경영과학회 1996년도 춘계공동학술대회논문집; 공군사관학교, 청주; 26-27 Apr. 1996
    • /
    • pp.570-573
    • /
    • 1996
  • The evaluation test for the operation of rotary type surface mounters which consist of the reel axis, the index table and the X-Y table, has been performed by comparing the new method with the old one in only fields. Because the problem seeking for the optimal operation of rotary type surface mounters, is NP complete, it is almost impossible to get the optimal solutions of large problems. This paper deals with a dynamic network modeling, which can reduce the effort, the cost, and the time used for the performance test of rotary type surface mounters.

  • PDF