• Title/Summary/Keyword: Operation Ratio

Search Result 2,782, Processing Time 0.03 seconds

Estimation of Annual Capacity of Small Hydro Power Using Agricultural Reservoirs (농업용저수지를 이용한 소수력의 연간발전량 추정)

  • Woo, Jae-Yeoul;Kim, Jin-Soo
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.52 no.6
    • /
    • pp.1-7
    • /
    • 2010
  • This study was carried out to investigate the effect of hydro power factors (e.g., irrigation area, watershed area, active storage, gross head) on annual generation capacity and operation ratio for agricultural reservoirs in Chungbuk Province with active storage of over 1 million $m^3$. The annual generation capacity and operation ratio were estimated using HOMWRS (Hydrological Operation Model for Water Resources System) from last 10-year daily hydrological data. The correlation coefficients between annual generation capacity and the hydro power factors except gross head were high (over 0.87), but the correlation coefficients between operational rate and the factors were low (below 0.28). The optimum multiple regression equations of the annual generation capacity were expressed as the functions of watershed area, active storage, and gross head. Also, the simple regression equation of annual generation capacity was expressed as a function of watershed area. The average relative root-mean-square-error (RRMSE) between observed and estimated values by the optimum multiple regression equations was smaller than that by the simple regression equation, suggesting that the former has more accuracy than the latter.

Optimal Microgrid Operation Considering Combined Heat and Power Generation with Variable Heat and Electric Ratio (가변 열전비를 갖는 열병합 발전설비가 포함된 마이크로그리드의 최적 운용)

  • Lee, Ji-Hye;Park, Je-Se
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.10
    • /
    • pp.1548-1553
    • /
    • 2012
  • The important requirement for microgrid operation is to meet the balance between supply and demand. To meet, Combined Heat and Power (CHP) generation should be considered in microgrid scheduling. CHP generation is economical on the side of a consumer because it products heat and power. Therefore, it is high efficient. This paper presents a mathematical model for optimal microgrid operation including CHP generation using the optimal ratio of heat and power due to demand. The objective function and constraints are modeled by linear program (LP). Through the case study, the validation of the proposed model is shown.

A study on the improvement of fuzzy ARTMAP for pattern recognition problems (Fuzzy ARTMAP 신경회로망의 패턴 인식율 개선에 관한 연구)

  • 이재설;전종로;이충웅
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.9
    • /
    • pp.117-123
    • /
    • 1996
  • In this paper, we present a new learning method for the fuzzy ARTMAP which is effective for the noisy input patterns. Conventional fuzzy ARTMAP employs only fuzzy AND operation between input vector and weight vector in learning both top-down and bottom-up weight vectors. This fuzzy AND operation causes excessive update of the weight vector in the noisy input environment. As a result, the number of spurious categories are increased and the recognition ratio is reduced. To solve these problems, we propose a new method in updating the weight vectors: the top-down weight vectors of the fuzzy ART system are updated using weighted average of the input vector and the weight vector itself, and the bottom-up weight vectors are updated using fuzzy AND operation between the updated top-down weitht vector and bottom-up weight vector itself. The weighted average prevents the excessive update of the weight vectors and the fuzzy AND operation renders the learning fast and stble. Simulation results show that the proposed method reduces the generation of spurious categories and increases the recognition ratio in the noisy input environment.

  • PDF

A Novel Vertical Directional Coupler Switch with Switching Operation-Induced, Extinction Ratio-Adjusted, and Extinction Ratio-Enhanced Sections

  • Cho, Sung-Chan;Hong, Hyun-Ha;Yang, Choong-Reol;Choi, Jee-Yon;Kang, Min-Ho;Hwang, Hyun-Yong;Choi, Young-Woo;Kim, Hae-Geun;Jung, Byung-Min;Kim, Boo-Gyoun
    • ETRI Journal
    • /
    • v.24 no.2
    • /
    • pp.109-116
    • /
    • 2002
  • We propose a novel very short (< $300{\mu}m$) vertical directional coupler switch with high extinction ratios larger than 30 dB. The device consists of a switching operation induced section (SOIS), an extinction ratio adjusted section (ERAS), and an extinction ratio enhanced section (ERES). These are achieved by changing the refractive index of one core. The switching operation is induced by changing the refractive index of one core in the SOIS. The improvement of extinction ratios larger than 30 dB for both the cross and bar states is made by controlling the asymmetry of the refractive indices of both cores in the ERES. Through the ERAS, different extinction ratios between the cross and bar states at the end of the SOIS are changed to the same value. For this reason, the optimum asymmetry of the refractive indices of the cores for the maximum extinction ratios and the lengths of ERES are the same for cross and bar states. Design guidelines for high extinction ratios with large tolerances are presented.

  • PDF

A Study on the Performance and Operation Limit of Electrodialysis Cell for HI Concentration (HI 농축에 대한 전기투석 셀의 성능 및 운전한계조건 연구)

  • Lee, Byung-Woo;Jeong, Seong-Uk;Cho, Won-Chul;Kang, Kyoung-Soo;Park, Chu-Sik;Bae, Ki-Kwang;Kim, Young-Ho;Kim, Chang-Hee
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.22 no.6
    • /
    • pp.749-758
    • /
    • 2011
  • The present work explores the performance and operation limit of electrodialysis cell for HI concentration in sulfur iodine thermochemical hydrogen production process, For this purpose, the electrodialysis cell was assembled with Nafion 117 as a PEM membrane and two activated carbon papers as the electrodes. HIx solution was prepared with composition of HI: $I_2$: $H_2O$ = 1: 0.5~2.5: 5.2 in molar ratio. The cell and its peripheral apparatus were placed in the specially designed convective oven in order to uniformly maintain the operation temperature. As operation temperature increased, the amount of water transport from anode to cathode increased, thus reducing HI molarity in catholyte. Meanwhile, the current efficiency was constant as about 90 %, irrespective of temperature change. The cell voltage increased with initial $I_2$ mole ratio as well as anolyte to catholyte mole ratio. Moreover the cell voltage overshot took place within 10 h cell operation, which is due to the $I_2$ precipitation inside the cell. From the analysis of $I_2$ mole ratio in the anolyte, it is noted that operation limit (in $I_2$ mole ratio) of the electrodialysis cell, arising from was measured to be 3.2, which is much lower than bulk solubility limit of 4.7.

Variation of water supply for instream flow from reservoirs with various magnifications of paddy irrigation area to watershed area (유역배율에 따른 저수지의 하천유지용수 공급량)

  • Noh, Jae-Kyoung;Lee, Jae-Nam
    • Korean Journal of Agricultural Science
    • /
    • v.38 no.2
    • /
    • pp.331-341
    • /
    • 2011
  • To provide variation of water supply for instream flow from reservoirs with various magnifications of paddy irrigation area to watershed area, 8 reservoirs were selected to draw operation rule curve and to analyze water supplies from reservoirs. Reliability of 90% for supplying irrigation water from reservoir was able to maintain and instream flow water was able to be supplied only in the reservoir with magnification of paddy irrigation area to watershed area above 3. The more magnification of paddy irrigation area to watershed area increased, the more ratio of irrigation water to total water storage decreased, and the more ratio of instream flow water to total water storage increased. From the heightening 113 reservoirs in Korea, annual irrigation water was estimated to 1,146.05 $Mm^3$ in normal operation, 839.57 $Mm^3$ in withdrawal limited operation, and annual instream flow water was estimated to 149.68 $Mm^3$ in normal operation, 283.19 $Mm^3$ in withdrawal limited operation. It was concluded that withdrawal limited operation was followed to have the premise of saving irrigation water, more instream flow water was able to be supplied from reservoirs with high magnification of paddy irrigation area to watershed area.

The Cooling control system with inverter (인버터를 통한 냉방제어시스템)

  • Moon, Joon-Soo;Woo, Yee-Wan;Park, Jea-Hong
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.43-48
    • /
    • 2011
  • Cooling system's operation ratio shall be controlled automatically by the internal external temperature sensors in rolling stock. The Cooling System shall be the automatic operation ratio control system which automatically controlling the rotation speed of condenser, evaporator etc. using temperature detection from outside and inside of cabin. This paper will examine the cooling system that can be provide comfortable cooling service for passenger in summer.

  • PDF

Excitation Voltage Control of SRM with Multi-Level Inverter (멀티레벨 인버터를 이용한 SRM의 여자전압제어)

  • Kang Yu-Jung;Lee Sang-Hun;Park Sung-Jun;Ahn Jin-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2001.12a
    • /
    • pp.29-32
    • /
    • 2001
  • The application of SRM(Switched Reluctance Motor) is dramatically increasing due to a simple mechanical structure, high efficiency and a good high speed characteristics. To control high conduction ratio in motor operation and regenerative voltage in the generator operation multi-level voltage control is effective. This paper proposes multi-level inverter to have a maximum conduction ratio of SRM. The proposed method is verified by experiments.

  • PDF

Composite Aerostatic Spindle (복합재료 공기정압 주축부)

  • 방경근;장승환;이대길
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 1999.11a
    • /
    • pp.134-138
    • /
    • 1999
  • For the stable operation of high speed aerostatic spindle, the low rotational inertia and high damping ratio of spindle shafts as well as high fundamental natural frequency are indispensable. Conventional steel spindles are not appropriate for very high speed operation because of their high rotational inertia and low damping ratio. In this study, the composite spindles with aerostatic bearing were designed and manufactured with carbon fiber/epoxy composite. The fundamental natural frequency of the composite spindle was evaluated through the modal testing.

  • PDF

Fuzzy Control of Speed Ratio for Electro-Hydraulic Rig Type CVT (전자 유압식 리그형 CVT의 변속비 퍼지제어)

  • Kim, S.H.;Kim, K.W.;Kim, H.S.;Eun, T.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.1 no.3
    • /
    • pp.63-73
    • /
    • 1993
  • In this paper, fuzzy control algorithm for the speed ratio control of the electro-hydraulic rig type continuously variable transmission(CVT) was proposed and the CVT performance tests were carried out for the optimal operation of the engine simulator. The experimental results for the constant throttle and the acceleration modes showed that the engine can be run on the optimum operating line, representing the power and economy mode, by the fuzzy control of the CVT speed ratio. Comparing the PID control with the fuzzy control, it was found that the fuzzy control showed better performance with the faster rising time and smaller steady state error. The result of this study can be used as basic design materials for developing the transmission control unit of the CVT.

  • PDF