• Title/Summary/Keyword: Operating point loss

Search Result 119, Processing Time 0.023 seconds

Fluid-Dynamic Study for the Chemical Cleaning of Young-Heung Thermal Power Plant Boiler Pipelines (영흥화력발전소 보일러배관 화학세정을 위한 유동검토)

  • Kim, Jin-Kwon;Kang, Shin-Hyoung
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.665-672
    • /
    • 2004
  • Chemical cleaning of boiler pipelines is necessary before the commissioning of thermal power plant after many years of construction. Fluid-Dynamic study for the chemical cleaning of boiler piplelines in Young-Heung thermal power plant is carried out. First, flow velocity necessary to sustain and exhaust solid particles in the vertical pipelines is calculated. Second, the flowrate necessary to make the calculated velocities in each vertical pipelines is calculated. Third, all the pipelines are analyzed with the Piping Systems Fluid Flow software to calculated the pressure loss in the pipelines. Finally, the operating point of the applied pump is calculated with the help of the same software.

  • PDF

According to the operating mode analysis loss of 3-Level NPC Inverter and T-type Inverter used in offshore wind power (해상 풍력 발전용 3-Level NPC 인버터와 T-type 인버터의 동작방식에 따른 손실 분석)

  • Kim, Han-Soo;Kim, Jeong-Heon;Hong, Seok-Jin;Shin, Soo-Cheol;Lee, Jong-Moo;Won, Chung-Yeun
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.421-422
    • /
    • 2013
  • 본 논문에서는 3-레벨의 NPC(Neutral Point Clamped) VSC와 T-type VSC를 시뮬레이션용 열 모델링 기법을 이용하여 스위칭과 도통 손실을 비교 분석하였다. 두 가지 토폴로지의 인버터동작과 회생동작에서의 주파수에 따른 효율을 시뮬레이션을 통하여 고찰 하였다.

  • PDF

Efficiency Optimization Control for High Performance Operation of Synchronous Reluctance Motor (동기 리럭턴스 전동기의 고성능 운전을 위한 효율 최적화 제어)

  • 정동화;이정철;이홍균
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.2
    • /
    • pp.51-56
    • /
    • 2001
  • This paper is proposed an efficiency optimization control algorithm for a synchronous reluctance motor (SynRM) which minimizes the copper and iron losses. fen exists a variety of combinations of d and q-axis current which provide a specific motor torque. The objective of the efficiency optimization controller is to seek a combination of d and q-axis current components, which provides minimum losses at a certain operating point in steady state. It is shown that the current components which directly govern the torque production have been very well regulated by the efficiency optimization control scheme. The proposed algorithm allows the electromagnetic losses in variable speed and torque drives to be reduced while keeping good torque control dynamics. Simulation results are presented to show the validity of the proposed algorithm.

  • PDF

Research and Analysis of Difference Hybrid DC Circuit Breaker Topologies for MVDC Distribution System (MVDC 배전시스템에서 다양한 복합형 직류 차단기의 토폴로지 연구 및 분석)

  • Go, Yu-Ran;Min, Myung-Hwan;An, Tae-Pung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.6
    • /
    • pp.503-510
    • /
    • 2020
  • The importance of DC breakers as key protection equipment is increasing in accordance with growing concerns on MVDC distribution network systems without DC/AC conversion. Different from the situation in AC systems, no natural zero-crossing point exists in DC systems. Thus, DC breaker technology is more difficult than AC breaker technology. The solutions for DC breakers can be divided into three types: mechanical, power electronics, and hybrid. In this study, the operating principles of several topologies of hybrid circuit breakers and that of the proposed DC breaker are analyzed and simulated by sorting two types. The breakers are compared in terms of the type and number of semiconductors, volume, power loss, auxiliary components, isolation, and other aspects. The advantages and disadvantages of the breakers are also analyzed.

A Study of the Tip Clearance Effect to the Performance of an Axial-Type Fan (축류형 송풍기의 익단간극이 성능에 미치는 영향에 관한 연구)

  • Cho, Chong-Hyun;Jung, Yang-Beom;Kim, Young-Cheol;Cho, Soo-Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.11 no.6
    • /
    • pp.7-17
    • /
    • 2008
  • Fan performances are obtained with various tip clearance gaps and stagger angles of the rotor. A tested fan is an axial-type fan of which the casing diameter is 806 mm. Two different rotors are applied to this test. One is designed on the basis of the free vortex method along the radial direction and the other is designed using the forced vortex method. The operating conditions are varied to the ultimate off-design point as well as the deign point. Overall efficiency, total pressure and input power are compared with the tip clearance gaps and different stagger angle. The experimental results show that changing of the stagger angle has minor influence to the performance when the same rotor is applied. When the tip clearance gap is less than 5% of the rotor span, the overall efficiency, total pressure loss and input power reduction are varied linearly with the variation of the tip clearance gaps. On the design point, the overall efficiency is decreased to the rate of 2.8-2.9 to the increasing of the tip clearance, but the changing rate of the overall efficiency is alleviated when the fan operates at off-design points. In particular, this rate is more quickly declined on a fan with the rotor designed using the forced vortex method. The result of the total pressure shows that the pressure reduction rate is a 0.08-0.1 according to the tip clearance, and additionally the input power reduction rate is a 0.045-0.065 at design point.

Utilization of Body Computed Tomography Scanners in Non-Metropolitan Area (비수도권(非首都圈) 지역(地域)에서의 전신용(全身用) X선(線) CT의 이용(利用))

  • Park, Young-Sun
    • Journal of radiological science and technology
    • /
    • v.8 no.2
    • /
    • pp.29-45
    • /
    • 1985
  • Computed Tomography Scanner (CT) is highly expensive in operation as well as purchasing. That reason may cause not only to increase the burden of patients but also to waste the capital resources leading to financial difficulties. However the numbers of CT installed throughout the country is increasing, because of efficiency in medical care, patient's concern, competitions among the hospitals within the same area. In the non-Metropolitan area the scanners were expected to be less utilized and less profitable. Nine hospitals equipped with the CT were studied on the utilization of that equipment during the period from November 1984 to February 1985 in non-Metropolitan area and break-even point in one hospital was analyzed for estimating profitabilities. The results were as follows ; 1. Among those nine hospitals, four hospitals had less than 400 beds, which is one of the restrictive minimum standards on the installation of Whole-body Computed Tomography Scanner. 2. The operating time during the normal operation period was longer than those of any other studies, but the accumulated down time was also longer than those of any other studies. The average number of scanning per week for each CT was 45, while the estimated number of for the break-even point was 56.7 cases. 3. When the downtime was excluded in calculating the average operation would be much closer to the cases for the break-even point. Therefore the break-down of the equipment was to be a main cause of the low profitability. 4. The average scanning rate for head area was 33.6%, however three of the nine hospitals showed about 20%. 5. If scanning ratio for the body parts excepting head was increased, the number of scanning for the break-even point would be diminished. 6. The small size hospital especially located near the Metropolitan area showed largest loss in the CT operation. In purchasing the highly expensive equipments in hospitals, demand should be taken into account and planning is recommended.

  • PDF

Anti-Parallel Diode Pair(APDP) Mixer over 3~5 GHz for Ultra Wideband(UWB) Systems (역병렬 다이오드를 이용한 초광대역 시스템용 3~5 GHz 혼합기 설계)

  • Jung Goo-Young;Lee Dong-Hwan;Yun Tae-Yeoul
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.7 s.98
    • /
    • pp.681-689
    • /
    • 2005
  • This paper presents an ultra wide band(UWB) mixer using anti-parallel diode pair(APDP) with simulation and measurement results. The proposed mixer adopts the even-harmonic direct conversion mixing, which consists of a couple of filter, in-phase wilkinson power divider, wideband $45^{\circ}$ power divider, and APDP. The m mixer is operating over 3.1 to 4.8 GHz and producing quadrature(I/Q) outputs with a conversion loss of 18 dB and input third order intercept point($IIP_3$) of 15 dBm. I/Q outputs also have difference of about 0.5 dB and phase difference of ${\times}3^{\circ}$ and $P_{1dB}$ of 2 dBm.

Design of Fractal Structure Wideband Antenna for 4G IMT-Advanced AccessPoint Applications (4세대 이동통신 Accesspoint용 Fractal구조 광대역 안테나 설계)

  • Kim, Dong-Hwan;Kim, Gab-Gi
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.1
    • /
    • pp.195-201
    • /
    • 2014
  • In this paper, an AccessPoint compact microstrip patch antenna was designed by using L-shaped feeding structure of a Fractal Structure and the compact antenna can be obtained by the rare formed presence of the resonance flow which is called "Crossed-Diagonal". CST's MicroWave5.0 was used for the design. As the operating characteristics of the patch antenna, it showed the characteristic of 1031 [MHz] or 29.4% in the range of 3.202 [GHz] ~ 4.233 [GHz] when an input return loss is less -10 [dB] and VSWR 2:1, also as it is in this paper, we got simulation results such as, gains of the E-plane and H-plane are 8.7 [dBi] and 8.6 [dBi] for this is the single patch, and 3 [dB] beamwidth is $43.9^{\circ}$ at E-plane and $78.7^{\circ}$ at H-plane.

A Study on Minimizing of Condenser Pressure Loss according to the Temperature Rise of the Seawater for Korean Standard Coal-fired Power Plants (표준석탄화력 발전소 해수온도 상승에 따른 복수기 압력 손실 최소화 방안)

  • An, Hyo-Yoel;Moon, Seung-Jae
    • Plant Journal
    • /
    • v.11 no.2
    • /
    • pp.45-51
    • /
    • 2015
  • In this paper, studied condenser operating management which is affecting power plants efficiency considering the cost of poor quality. Sea water temperature and condenser pressure have clear correlation in S power plants. As the sea water temperature changes, condenser pressure changed -1.7~+20 mmHg from design condenser pressure(38.1 mmHg). Use the heat rate correction curve from manufactory company, realized that efficiency and cost of poor quality changed 0.0201%, 12,830 won/h at Unit #1,2 but 0.0155%, 9,832 won/h when condenser pressure 1 mmHg rise. Also, checked that it is changed depend on seasonal corresponding operation, plant ageing and the point of preventive maintenance like overhaul maintenance. This study said if we considered complying with management range and planning overhaul maintenance, then it could help reducing operating maintenance losses minimum 2.5 billion won per 1 year (case : Unit #1, forty days maintenance).

  • PDF

Neural Network Based On-Line Efficiency Optimization Control of a VVVF-Induction Motor Drive (인공신경망을 이용한 VVVF-유도전동기 시스템의 실시간 운전효율 최적제어)

  • Lee, Seung-Chul;Choy, Ick;Kwon, Soon-Hak;Choi, Ju-Yeop;Song, Joong-Ho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.2
    • /
    • pp.166-174
    • /
    • 1999
  • On-line efficiency optimization control of an induction motor drive using neural network is important from the v viewpoints of energy saving and controlling a nonlinear system whose charact81istics are not fully known. This paper p presents a neural networklongleftarrowbased on-line efficiency optimization control for an induction motor drive, which adopts an optimal slip an밍J.lar frequency control. In the proposed scheme, a neuro-controller provides minimal loss operating point i in the whole range of the measured input power. Both simulation and experimental results show that a considerable e energy saving is achieved compared with the conventional constant vlf ratio operation.

  • PDF