• 제목/요약/키워드: Operating Capacity

검색결과 1,189건 처리시간 0.02초

인버터 스크롤 압축기를 사용한 멀티 에어컨의 냉방 특성에 대한 실험적 연구 (Experimental Study on Cooling Characteristics of Multi - Air Conditioner using Inverter Scroll Compressor)

  • 권영철;고국원;진의선;허삼행;전용호;이영덕;박인규
    • 설비공학논문집
    • /
    • 제16권4호
    • /
    • pp.311-317
    • /
    • 2004
  • In the present study, the cooling characteristics of the multi-air conditioner (A/C) using an inverter scroll compressor are experimentally investigated for the number of the indoor units and the operating conditions (2$0^{\circ}C$, 24$^{\circ}C$, 26$^{\circ}C$) under the cooling standard conditions by KS C 9306. In the case of the simultaneous operation for 3 indoor units, the cooling capacity, the mass flow rate and the input power have a decreasing trend and COP has an increasing trend, with decreasing the difference in the operating temperature of the indoor unit and the room temperature. In the case of the simultaneous operation for 2 indoor units, the COP of the indoor unit with large cooling capacity is high when the operating temperature is high, but the COP of the indoor unit with low cooling capacity is high when the operating temperature is low. In the case of the single operation for one unit, when the large cooling capacity of the indoor unit is less than 50% the compressor operates at the minimum operation frequency region and the COP decreases.

슈퍼컴퓨터센터의 최적 운영환경을 위한 기반시설 용량 산정에 관한 연구 (A Study on the Infra-Capacity Analysis for Optimal Operating Environments of Supercomputer Center)

  • 류영희;성진우;김덕수;길성호
    • KIEAE Journal
    • /
    • 제10권2호
    • /
    • pp.19-24
    • /
    • 2010
  • According to the increasing demands of supercomputer, an exclusive supercomputer building is requested to install a supercomputer for promoting high-end R&D as well as creating the public service infrastructure in the national level. KISTI, as a public supercomputer center with the 4th supercomputer (capacity of 360Tflops), is experiencing shortage of infrastructure systems, caused by increased capacity. Thus, it is anticipated that the situation will be growing serious when the 5th and 6th supercomputers will be installed. On this study, analyzed on the 5th supercomputer system through projecting performance level and optimal operating environments by assessing infra-capacity. Explored way to construct optimal operating environments through infrastructure-capacity analysis of supercomputer center. This study can be of use for reviewing KISTI's conditions as the only supercomputer center in Korea. In addition, it provides reference data for planning the new exclusive supercomputer center in terms of feasibility, while analyzing infrastructure systems.

국가적 관점에서 용도별 ESS 적정용량 산정을 위한 운전수리모델 수립에 대한 연구 (A Study on Establishing Operation Mathematical Model for Optimum Capacity Estimation of the ESS Applications for each in the Nationwide Perspective)

  • 김정훈;윤석민
    • 전기학회논문지
    • /
    • 제65권6호
    • /
    • pp.969-978
    • /
    • 2016
  • Around the world are increasing the demand for ESS. Currently, the domestic is expected to benefit by operating ESS. In the domestic, it is expected to benefit from operations of the installed ESS because of the introduction of ESS less capacity. However ESS capacity to the maximum profit occurs is unknown. ESS is different from the charge-discharge characteristics and the reserve to replace, depending on the application. Therefore, it should be established in accordance with the ESS optimal capacity according to the purpose used because it can maximize the quality and efficiency of the electric energy. To the ESS optimal capacity estimation by the purpose used, It should compare the investment cost caused by ESS facility installation and operation cost caused by operating ESS. In this paper, the operation mathematical model for estimating marginal operation costs established. In operation mathematical model, operating cost is considered fuel cost and no-load cost start-up cost. Because no-load cost and start-up cost are not related to cost and power plant output, there are expressed an integer variable costs as a step function.

Three Buffer 맥동관 냉동기에 관한 실험적 연구 (An Experimental Study of a Therr Buffer Pulse Tube Refrigerator)

  • 박성재;고득용;김효봉;신완순
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제1권2호
    • /
    • pp.54-59
    • /
    • 1999
  • An experimental study was carried out to improve the cooling capacity and performance of the pulse tube refrigerator. Three buffer pulse tube refrigerator was designed and fabricated, and the experimental apparatus operating process of the therr buffer pulse tube refrigerator and results obtained with the performance test. The cooldown characteristics and load characteristics are described. The lowest temperature measured in the three buffer pulse tube refrigerator was 88K and the cooling capacity at the optimum operating condition was 27 W at 120K.

  • PDF

발전용량 및 풍속에 따른 국내 풍력 발전단지의 효율성 분석 (The Effect of Power Generation Capacity and Wind Speed on the Efficiency of the Korean Wind Farms)

  • 이중우;고광근;이기광
    • 경영과학
    • /
    • 제30권2호
    • /
    • pp.97-106
    • /
    • 2013
  • Of the new and renewable energies currently being pursued domestically, wind energy, together with solar photovoltaic energy, is a new core growth driver industry of Korea. As of May 2012, 33 wind farms at a capacity of 347.8MW are in operation domestically. The purpose of this study was to compare and analyze how efficiently each operational wind farm is utilizing its power generation capacity and the weather resource of wind. For this purpose, the study proceeded in 3 phases. In phase 1, ANOVA analysis was performed for each wind farm, thereby categorizing farms according to capacity, region, generator manufacturer, and quantity of weather resources available and comparing and analyzing the differences among their operating efficiency. In phase 2, for comparative analysis of the operating efficiency of each farm, Data Envelopment Analysis (DEA) was used to calculate the efficiency index of individual farms. In the final phase, phase 3, regression analysis was used to analyze the effects of weather resources and the operating efficiency of the wind farm on the power generation per unit equipment. Results shows that for wind power generation, only a few farms had relatively high levels of operating efficiency, with most having low efficiency. Regression analysis showed that for wind farms, a 1 hour increase in wind speeds of at least 3m/s resulted in an average increase of 0.0000045MWh in power generation per 1MW generator equipment capacity, and a unit increase in the efficiency scale was found to result in approximately 0.20MWh power generation improvement per unit equipment.

충전압력 및 작동주파수 특성 연구에 의한 스터링 냉동기 개발 (The effect of the charging pressure and operating frequency in the Stirling Cryocooler)

  • 박성제;홍용주;김효봉;고득용;김양훈;유병건;이기백
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제3권2호
    • /
    • pp.62-68
    • /
    • 2001
  • This paper presents manufacturing process and test results in the optimum pressure and operating frequency for the free piston free displacer(FPFD) Stirling cryocooler designed and manufactured by Korea Institute of Machinery &Materials (KIMM). FPFD Stirling cryocooler is currently under development uses opposed linear motors to drive opposed pistons . The performance of FPFD Stirling cryocooler is evaluated as a function fo charging pressure and operating frequency. In general as the operating frequency of the compressor is increaed but natural frequency of the displacer is almost constant. The prototype has achieved no load temperature of 49K and cooling capacity of 0.5W at 7.2K.

  • PDF

열전모듈 제습기의 에너지 효율과 성능에 미치는 설계 인자의 영향 분석 (The Analysis of the Effects of Design Parameters on the Energy Efficiency and Performance of TEM Dehumidifiers)

  • 이태희
    • 한국지열·수열에너지학회논문집
    • /
    • 제16권3호
    • /
    • pp.1-7
    • /
    • 2020
  • To provide a design direction for high efficiency thermoelectric module(TEM) dehumidifiers, the effects of design factors of TEM dehumidifiers on dehumidification energy efficiency and performance were numerically investigated. The design factors considered in this study are the TEM capacity, the performance of heat exchangers on the heating and cooling surfaces of the TEM. The higher capacity of the TEM results the higher dehumidification energy efficiency and performance at some operating voltage. The enhanced performance of the heat exchanger on heating surface increased the dehumidification energy efficiency and performance at all the operating voltage. The enhanced performance of the heat exchanger on cooling surface decreased the dehumidification energy efficiency and performance at all operating voltage.

정박지의 효율적 운영을 위한 세칙 개정방안 (A Study on the Revision of Regulations for Effective Operation of Anchorage)

  • 윤귀호
    • 해양환경안전학회지
    • /
    • 제20권4호
    • /
    • pp.398-404
    • /
    • 2014
  • 우리나라 주요 항만에 규정되어 있는 정박지와 관련한 운영 세칙은 항만마다 정박지 운영 기준이나 정박지 선박수용능력에 대한 단위가 단일화 되어있지 않으며, 동일한 사안에 대해 다른 용어들을 사용하고 있다. 이로 인해 정박지를 운영하거나 이용하고자 하는 당사자들에게 큰 혼란을 주고 있는 상황이다. 본 연구에서는 국내 주요 항만의 정박지 운영 세칙을 검토하여 세칙명, 단위 및 용어의 단일화 방안을 제안하였다. 아울러 정박지 운영상의 혼란을 최소화하기 위하여 외국 주요 항만의 정박지 현황 검토를 통하여 향후 세칙 개정시 정박지 명칭 부여 원칙, 정박지 선박수용능력 단위 및 정박지의 수용가능한 선박 척수의 설정이 이루어지도록 제안하였다.

On-off 제어계통을 갖는 냉동기의 최적제어에 관한 연구 (A study on the optimum control of refrigerator with on-off control system)

  • 하주식;김원녕;김경근;오철
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제9권4호
    • /
    • pp.317-327
    • /
    • 1985
  • In the case of temperature control of air conditioning and refrigerating system, it is possible to operate the system continuously by controlling the cooling capacity of refrigerating machines. But on-off control system has been adopted for refrigerating system which has more large capacity than that required to remove the generated heat. In this on-off control system, it can be considered that there exists some optimum condition for the refrigerating capacity, operating cycle, running hour, and the temperature difference between thermostat setting value and real one. In this paper, an equation was derived to express the temperature variation of the refrigerated object (Nybrine) and later two evaluating functions were derived. One is for the temperature difference and another is for operating cycle and running hour. The weighted sum of these two functions is defined as the criterion function for the evaluation of the control performance of the system, and then the optimum running condition is investigated in the sense of minimizing the criterion function. Experiments showed that the heat balance equation derived for the temperature variation and the estimation of the time constant of the refrigerated system are appropriate. By conclusion, if a proper weighting factor D is selected, the optimum conditions exist for the refrigerating capacity, running hour, and operating cycle in the on-off temperature control of the refrigerating system.

  • PDF

발전소용 공랭식 응축기(ACC)의 작동조건 변화에 따른 성능특성에 대한 수치적 연구 (A Numerical Study on the Performance Characteristics of a Power Plant Air-Cooled Condenser (ACC) Affected by Changes in Operating Conditions)

  • 박경민;주기홍;박창용
    • 한국생산제조학회지
    • /
    • 제26권2호
    • /
    • pp.243-250
    • /
    • 2017
  • A numerical study was conducted to calculate the cooling capacity variation of a power plant ACC (air-cooled condenser) caused by changes in operating conditions. A numerical model was developed using the ${\varepsilon}-NTU$ and finite volume method, containing 100 elements for a single low fin tube. The model was validated through a comparison of cooling capacity between the simulated values and manufacturer's data. Even though simple assumptions and previously presented heat transfer correlations were applied to the model, the prediction error was 1.9%. The simulated variables of the operating conditions were air velocity, air temperature, and mass flux. The analysis on the variation of thermal resistance along the tube showed that the water side thermal resistance was higher than the air side thermal resistance at the downstream end of the tube, indicating that the ACC capacity could be increased by applying technology to enhance in-tube flow condensation heat transfer.