• Title/Summary/Keyword: Opening height

Search Result 216, Processing Time 0.03 seconds

The Field Investigation of Optical Shop Entrance Facilities for the Mobility Impairment from the Universal Design - Focused on Seoul Metropolitan City (유니버설디자인 관점에서 이동약자를 위한 안경원 출입구 편의시설 실태조사 - 서울특별시를 중심으로)

  • Yu, Samyoung;Lee, Sehee;Han, Jinyong;Kim, Youngbin;Choi, Moonsung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.29 no.1
    • /
    • pp.7-19
    • /
    • 2023
  • Purpose: Mobility impairment persons are all people who experience mobility difficulties in their daily lives, which makes up about 30% of the population in Seoul Metropolitan City; this number is expected to increase with population aging. As the number of mobility impairment persons in need of vision correction increases, it is necessary to create the Universal Design guidelines and to provide the foundation to access convenience facilities at the entrance of optical shops, a health and medical institution. Methods: Of the 2,282 optical shops located in Seoul, 252 optical shops were chosen for data collection of actual photos, from April 10, 2022 to September 4, 2022. Based on the photographs, the height difference between the entrance and the sidewalk, safety handles, and opening and closing methods of entrances were investigated, as these factors correspond to the accessibility and the mobility of the mobility impairment persons. Results: Of the 252 optical shops surveyed, 114 (45.2%) have resolved the problems of height difference through improving horizontal accessibility (61) or using ramps (53). 36 (14.3%) optical shops chose automatic doors for opening and closing methods of the entrance. Implications: The rate of installation of access convenience facilities for the entrance of optical shops is slightly lower than the rate of installation of ramps, surveyed by the Ministry of Health and Welfare. It is necessary to apply the Universal Design to access convenience facilities for the entrance of optical shops for not only the mobility impairment persons but all people, regardless of age or ability, to conveniently access healthcare services.

A cephalometric study on the relationship between mandibular opening movement and morphology of craniofacial skeleton (아동의 개구운동과 두개안면골격형태의 상관성 -측모두부방사선 계측법적 연구-)

  • Kim, Min-Shil;Chung, Kyu-Rhim
    • The korean journal of orthodontics
    • /
    • v.30 no.3 s.80
    • /
    • pp.297-306
    • /
    • 2000
  • Lateral cephalometric X-ray films in maximal intercuspation and maximal opening of 68 children were taken and analyzed to examine the pattern of condylar movement and to study the relationship between opening movement and morphologic factors of craniofacial skeleton. The results were as follows : 1. The mean value of maximal opening capacity was 47.1mm, condylar moving distance was 18.1mm, horizontal condyle movement was 17.5mm, vertical condyle movement was 3.8mm and condylar moving angle was $13.1^{\circ}$. 2. The maximal opening capacity had positive relationship with the length of anterior cranial base, mandible and maxillary complex and with posterior facial height and had negative relationship with articular angle, sagittal jaw relationship. 3. Vertical condyle movement and condylar moving angle had positive relationship with articular angle and had negative relationship with gonial angle. 4. Horizontal condyle movement and condylar moving distance had positive relationship with the length of maxillary complex.

  • PDF

Development for Fishing Gear and Method of the Non-Float Midwater Pair Trawl Net (II) - Opening Efficiency of the Model Net according to Front Weight and Wing-end Weight - (무부자 쌍끌이 중층망 어구어법의 개발 (II) - 추와 날개끝 추의 무게에 따른 모형어구의 전개성능 -)

  • 유제범;이주희;이춘우;권병국;김정문
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.39 no.3
    • /
    • pp.189-196
    • /
    • 2003
  • In this study, the vertical opening of the non-float midwater pair trawl net was maintained by controlling the length of upper warp. This was because the head rope was able to be kept linearly and the working depth was not nearly as changed with the variation of flow speed as former experiments in this series of studies have demonstrated. We confirmed that the opening efficiency of the non-float midwater pair trawl net was able to be developed according to the increase in front weight and wing-end weight. In this study, we described the opening efficiency of the non-float midwater pair trawl net according to the variation of front weight and wing-end weight obtained by model experiment in circulation water channel. We compared the opening efficiency of the proto type with that of the non-float type. The results obtained can be summarized as follows:1. The hydrodynamic resistance was almost increased linearly in proportion to the flow speed and was increased in accordance with the increase in front weight and wing-end weight. The increasing rate of hydrodynamic resistance was displayed as an increasing tendency in accordance with the increase in flow speed. 2. The net height of the non-float type was almost decreased linearly in accordance with the increase in flow speed. As the reduced rate of the net height of the non-float type was smaller than that of the net height of the proto type against increase of flow speed, the net height of the non-float type was bigger than that of the proto type over 4.0 knot. The net width of the non-float type was about 10 m bigger than that of the proto type and the change rate of net width varied by no more than 2 m according to the variation of the front weight and wing-end weight. 3. The mouth area of the non-float type was maximized at 1.75 ton of the front weight and 1.11 ton of the wing-end weight, and was smaller than that of the proto type at 2.0∼3.0 knot, but was bigger than that of the proto type at 4.0∼5.0 knot. 4. The filtering volume was maximized at 3.0 knot in the proto type and at 4.0 knot in the non-float type. The optimal front weight was 1.40 ton.

Load-Displacement Formulations of Low-rise Unbounded RC Shear Walls with or without Openings

  • Lou, K. Y.;Cheng, F. Y.;Sheu, M. S.;Zhang, X. Z.
    • Computational Structural Engineering : An International Journal
    • /
    • v.1 no.2
    • /
    • pp.117-130
    • /
    • 2001
  • Investigations of low-rice unbounded reinforced concrete shear walls with or without openings are performed with comparison of analytical and experimental results. Theoretical analysis is based on nonlinear finite element algorithm, which incorporates concrete failure criterion and nonlinear constitutive relationships. Studios focus on the effects of height-to-length ratio of shear walls, opening ratio, horizontal and vertical reinforcement radios, and diagonal reinforcement. Analytical solutions conform well with experimental results. Equations for cracking, yielding and ultimate loads with corresponding lateral displacements are derived by regression using analytical results and experimental data. Also, failure modes of low-rise unbounded shear walls are theoretically investigated. An explanation of change in failure mode is ascertained by comparing analytical results and ACI code equations. Shear-flexural failure can be obtained with additional flexural reinforcement to increase a wall's capacity. This concept leads to a design method of reducing flexural reinforcement in low-rise bounded solid shear wall's. Avoidance of shear failure as well as less reinforcement congestion leer these walls is expected.

  • PDF

Optimum Fire Extinguishing Modeling using Impact Factor Analysis on Water Mist System of Pool Fire (영향인자 분석을 통한 고임화재의 미분무수 최적소화 모델링)

  • Hwang, Won-Jun;Kim, Hwang-Jin;Lee, Sung-Eun;Kim, Sung-Won;Oh, Kyu-Hyung
    • Fire Science and Engineering
    • /
    • v.23 no.5
    • /
    • pp.84-89
    • /
    • 2009
  • In this study, the fire extinguishing experiment was performed using a water mist nozzle with variation of factors which affect on the extinguishing time. The variables were distance from nozzle center to fire location, droplet size, height of nozzle and opening or not. With the experimental data, interaction and sensitivity between factors were analysed with Mini tab and deduce a optimum model of fire extinguishing of water mist system. Based on the experiment and modeling of fire extinguishing with water mist system, the most important factor on extinguishing time is the distance from the center of nozzle to fire and the opening effect was small compare with other factors.

Natural Ventilation Planning by Analysis on Air Velocity Property of a Traditional Korean House (한국 전통주거의 기류 분석을 통한 자연통풍 설계 연구)

  • 최윤정;김인선;허범팔
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2001.05a
    • /
    • pp.117-120
    • /
    • 2001
  • This study is a preliminary research to develop design principles for environmentally friendly housing. The purposes of study are to investigate the literatures related passive design for summer and theory of ventilation, to analyze the indoor airflow patterns in traditional Korean house during summer, and to propose the design factors for effective passive cooling system. The analysis for airflow patterns was focused on the ‘An bang’and the ‘Dae Chung’in the ‘An Chae’of a traditional house located in Seoul. Field measurements of air temperature and air velocity were carried out at 30 different measuring points with 8 different window-opening conditions. The measurements were taken on the hottest summer days in August 2000. It is concluded that from an environmentally friendly standpoint design factors to control indoor thermal environment by a passive cooling system during the summer are as follows; ceiling structure has thermal performance like a time-lag effect, optimum height and length of eaves which can prevent sunlight and divert airflow toward the sitting level, building arrangement acceptable the prevailing wind, strategic window arrangement which makes cross ventilation possible (especially north-south) at the sitting level, window opening condition which is possible to intersect two cross-ventilation stream at the main living areas, northward windows remaining in shade to create the air pressure difference, and planning building shape like a bracket that has optimum width and depth.

  • PDF

A Study on the Mechanical Ventilation System of Bathroom in Apartment House (공동주택 화장실의 기계 환기시스템에 관한 연구)

  • 함진식
    • Journal of the Korean housing association
    • /
    • v.12 no.3
    • /
    • pp.141-148
    • /
    • 2001
  • To design mechanical ventilation for bathroom of apartment houses where air supply and exhaust are taken into consideration, mock-ups of ventilation systems, widely used in bathroom of apartment houses with an area of 100$\textrm{m}^2$, were made and installed in a laboratory. These ventilation mock-ups were available for control of air supply and exhaust, and the sizes of supply openings were 40cm${\times}$1cm, 40cm${\times}$3cm, and 40cm${\times}$5cm. They were installed at five positions, spaced 45cm at a height of 5cm from the floor. The exhaust fan was designed for its operating voltage to be set to five steps(100V, 130V, 150V, 180V and 220V) in order to control its air flow rates. When the size and position of each supply opening were changed with the wind velocity of the exhaust fan set to the step 5, the ventilation rates were measured and analyzed by the concentration decay method of tracer gas method, in order to present an efficient mechanical ventilation system. The results of the study revealed that the ventilations rates would increase in the presence of supply openings, compared to the absence of supply openings, and that the larger the size of the supply opening, the more the ventilation rates. Therefore, it was found necessary to take air supply into consideration.

  • PDF

Articulatory Manifestation of Prosodic Strengthening in English /i/ and /I/

  • Kim, Sa-Hyang;Cho, Tae-Hong
    • Phonetics and Speech Sciences
    • /
    • v.3 no.4
    • /
    • pp.13-21
    • /
    • 2011
  • The present study investigated the effects of two different sources of prosodic strengthening, i.e., boundary and accent, in the articulation of English high front vowels, /i/ and /I/. The vowels were investigated in vowel-initial ('eat' vs. 'it'), /h/-initial ('heat' vs. 'hit') and /p/-initial words ('Pete' vs. 'pit'), which were placed in varying prosodic conditions. Using Electromagnetic Articulograph (EMA), the tongue dorsum positions in the x and y dimensions, the lip opening and the jaw opening (lowering) were measured. With respect to the boundary-induced strengthening, results showed that /i/ and /I/ in vowel-initial words ('eat' - 'it') are produced with a higher tongue position in the domain-intial than domain-medial positions. The fact that the vowels only in the vowel-initial condition showed the domain-intial strengthening (DIS) effect suggests that the DIS effect is localized mainly to the initial position (the locality account). As for the accent-induced strengthening, vowels were produced with a more fronted tongue position and larger lip opening in accented than unaccented positions. This suggests that the presence of accent increases overall sonority of the vowels in various prosodic contexts, and enhances primarily the frontedness of the front high vowels. Taken together, the results indicate that the two types of prosodic strengthening are articulatorily realized differently, supporting the view that they are encoded separately in the speech planning process. The present study also showed the distinction between the two high front vowels in the tongue position (in both the frontedness and the height dimensions), while the jaw did not seem to contribute to the distinction robustly, suggesting that the tongue contributes more in distinguishing the two vowels than the jaw does.

  • PDF

Development of Basic Pants Patterns for Women in Their 20s (20대 성인여성의 팬츠원형 개발)

  • Lee, Mi Sung;Kim, Sora
    • Journal of Fashion Business
    • /
    • v.19 no.1
    • /
    • pp.17-33
    • /
    • 2015
  • This study aimed to develop basic pants patterns reflecting somatotype characteristics of the women in their 20s. In order to develop basic pants patterns for women in their 20s, wearing tests were conducted. With the results of wearing tests, drafting methods were applied by using regression equation for the parts that were found to improper. For the parts where regression equation was not applicable, the results of wearing tests were applied. The results and the conclusion of development of basic pants patterns for women in their 20s were as follows. The waist height was applied for the regression equations of waist to hip length, crotch length, and knee length, and the hip circumference was applied for the regression equations of front leg opening. Also, back leg opening, front knee width and back knee width were calculated based on the front leg opening. For the waistline the ease of 2cm was added, and for the hipline the ease of 4cm was added. H/16 - 1cm was applied for the drafting of front crotch width, and H/8 was applied for the drafting of back crotch width. Pants patterns for women in their 20s on the methods mentioned above were tested for the $2^{nd}$ research wearing tests, and they received good ratings on the items and demonstrated that the developed pants patterns had excellent body fit.

Morphometric Study of the Korean Adult Pituitary Glands and the Diaphragma Sellae

  • Ju, Kyo-Sung;Bae, Hack-Gun;Park, Hyung-Ki;Chang, Jae-Chil;Choi, Soon-Kwan;Sim, Ki-Bum
    • Journal of Korean Neurosurgical Society
    • /
    • v.47 no.1
    • /
    • pp.42-47
    • /
    • 2010
  • Objective: To investigate the morphometric characteristics of the pituitary gland and diaphragma sellae in Korean adults. Methods: Using the 33 formaline fixed adult cadavers (23 male, 10 female), the measurements were taken at the diaphragma sellae and pituitary gland. The authors investigated the relationship between dura and structures surrounding pituitary gland, morphometric aspects of pituitary gland and stalk, and morphometric aspect of central opening of diaphragma sellae. Results: The boundary between the lateral surface of pituitary gland and the medial wall of cavernous sinus was formed by the thin dural layer and pituitary capsule. The pituitary capsule adherent tightly to the pituitary gland was observed to continue from the diaphragma sellae. Mean width, length, and height of the pituitary gland were 14.3${\pm}$2.1, 7.9${\pm}$1.3, and 6.0${\pm}$0.9 mm in anterior lobes, and 8.7${\pm}$1.7, 2.9${\pm}$1.1, and 5.8${\pm}$1.0 mm in posterior lobes, respectively. Although all dimensions of anterior lobe in female were slightly larger than those in male, statistical significance was noted in only longitudinal dimension. The ratio of posterior lobe to the whole length of pituitary gland was about 27%. The mean thickness of pituitary stalk was 2 mm. The diaphragmal opening was 5 mm or more in 26 (78.8%) of 33 specimen. The opening was round in 60.6% of the specimen, and elliptical oriented in an anterior-posterior or transverse direction in 39.4%. Conclusion: These results provide the safe anatomical knowledge during the transsphenoidal surgery and may be helpful to access the possibility of the development of empty sella syndrome.