• 제목/요약/키워드: Open-end load

검색결과 48건 처리시간 0.032초

PZT계 압전 세라믹 파이버 복합체의 기계적 물성과 압전 풍력 에너지 하베스팅 특성 (Mechanical Properties and Wind Energy Harvesting Characteristics of PZT-Based Piezoelectric Ceramic Fiber Composites)

  • 이민선;박진우;정영훈
    • 한국전기전자재료학회논문지
    • /
    • 제34권2호
    • /
    • pp.90-98
    • /
    • 2021
  • Piezoelectric ceramic fiber composite (PCFC) was fabricated using a planar electrode printed piezoelectric ceramic fiber driven in transverse mode for small-scale wind energy harvester applications. The PCFC consisted of an epoxy matrix material and piezoelectric ceramic fibers sandwiched by interdigitated electrode (IDE) patterned polyimide films. The PCFC showed an excellent mechanical performance under a continuous stress. For the fabrication of PCB cantilever harvester, five -PCFCs were vertically attached onto a flexible printed circuit board (PCB) substrate, and then PCFCs were serially connected through a printed Cu circuit. The energy harvesting performance was evaluated applying an inverted structure, which imples its free leading edge located at an open end but the trailing edge at a clamped end, to enhance strain energy in a wind tunnel. The output voltage of the PCB cantilever harvester was increased as the wind speed increased. The maximum output power was 17.2 ㎼ at a resistance load of 200 ㏀ and wind speed of 9 m/s. It is considered that the PCB cantilever energy harvester reveals a potential use for wind energy harvester applications.

모래지반에 타입된 모형 개단강관 말뚝의 지지력 분석 (Bearing Capacity of Model Open -Ended Steel Pipe Pile Driven into Sand Deposit)

  • 백규호;이종섭;이승래
    • 한국지반공학회지:지반
    • /
    • 제9권1호
    • /
    • pp.31-44
    • /
    • 1993
  • 말뚝이 설치되는 동안과 하중이 재하되는 동안에 유발되는 관내토의 거동과 관내토가 개단 말뚝의 지지력에 미치는 영향, 그리고 관내토의 하중전이 메카니즘 등을 알아보기 위하여, 개단말뚝의 단면부에 작용하는 지지력과 관내토에 의한 지지력 및 외주면마찰력을 분리하여 측정할 수 있도록 제작된 모형 개단강관말뚝과 압력조절이 가능한 토조를 이용하여 모래지반을 대상으로한 모형말뚝실험을 실시하였다. 실험결과로부터, 개단말뚝의 폐색정도는 폐색길이비(PLR)보다는 특정회수율(${\gamma}$)에 의하여 더 정화히 성의될 수 리음을 알 수 있으며, 내주면마찰력의 대부분은 말뚝 선단부로부터 말뚝내경의 3배까지의 영역에 존재하는 관내토에 의하여 발생되는 것으로 나타났다. 또한 전체 지지력에서 내주면마찰력이 차지하는 비율은 외주면마찰력이 차지하는 비율보다 상당히 크기 때문에, 개단말쪽의 지지력 산정시 내주면마찰력은 필수적으로 고려되어야 한다.

  • PDF

부하측 이상 검출 차단 장치를 내장한 고효율 자기식 네온 변압기의 설계 (Design of a High Efficiency Neon Transformer with Abnormal Load Interrupting Circuit)

  • 변재영;김윤호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.723-726
    • /
    • 2002
  • In this paper, a high efficiency leakage transformer for neon tube is developed to improve its power factor, to reduce its core loss and weight by using a technique of shape optimization and direction of grain-oriented silicon steel sheet. A protection circuit is designed for all types of neon transformer loaded with one or more neon lamps. Whenever the neon tube fails to be started up or comes to the life end, or encounters faults with open-circuits at the output terminals of the neon transformer, the protection circuit will be initiated to avoid more critical hazards. These neon transformers need a protection circuit to prevent from current stresses on circuit components by neon tube fail. The input of the transformer is automatically cut off when the abnormal condition occurs, preventing waste of no-load power. As the results of the study, the core weight is reduced by $11\%$, the power factor improved by $5\%$ and the efficiency increased by $6\%$ compared with the conventional type due to the employment of the grain-oriented steel sl)eel and the optimized core shape.

  • PDF

The Influence of Forest Fire Simulation on the Properties of Polymer Insulators

  • Lee, Won-Kyo;Choi, In-Hyuk;Lee, Dong-Il;Han, Se-Won
    • Transactions on Electrical and Electronic Materials
    • /
    • 제10권5호
    • /
    • pp.161-164
    • /
    • 2009
  • Forest fire simulation tests were performed with polymer and porcelain insulators at GOCHANG Power Testing Center. These tests consisted of open flames causing a temperature rise of up to $600{\sim}800^{\circ}C$ measured at the insulator surfaces. Mechanical and electrical characteristics such as the specific mechanical load, the low frequency dry flashover voltage and the impulse flashover voltage were analyzed for the polymer insulators before, during and after the simulation tests and then compared to the porcelain insulators. At the end of the fire simulation tests, there was no detrimental deterioration of any of the insulators. All the insulators passed the KEPCO specification criteria. This study showed that the forest fire simulation had no impact on the polymer insulators.

폴리머 애자의 산불 신뢰성 평가 연구 (A Study on the reliability analysis of Forest Fire on Polymer Insulators)

  • 이원교;최인혁;황갑철;최한열
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.460-461
    • /
    • 2008
  • The forest fire simulation tests were performed with polymer and porcelain insulators at Gochang testing center. These tests consisted of energizing 90 kV at line-to-ground voltage of 154 kV lines and open flame rising up to $600-630^{\circ}C$ as being measured at insulator surface. Mechanical and electrical characteristics such as specific mechanical load, leakage current, low frequency dry flashover voltage and impulse flashover voltage were analyzed for the polymer insulators before, during and after simulation tests compared with porcelain insulators. At the end of fire simulation tests, there was no detrimental deterioration of any insulators. All insulators passed the criteria of KEPCO specification. This study showed that forest fire simulation had no impact on polymer insulators.

  • PDF

A New Architecture to Offload Network Traffic using OpenFlow in LTE

  • Venmani, Daniel Philip;Gourhant, Yvon;Zeghlache, Djamal
    • 한국산업정보학회논문지
    • /
    • 제17권1호
    • /
    • pp.31-38
    • /
    • 2012
  • Next generation cellular applications and smart phone usage generate very heavy wireless data traffic. It becomes ineluctable for mobile network operators to have multiple core network entities such as Serving Gateway and Packet Data Network Gateway in 4G-LTE to share this high traffic generated. A typical configuration consists of multiple serving gateways behind a load-balancer which would determine which serving gateway would service a end-users'request. Such hardware is expensive, has a rigid policy set, and is a single point of failure. Another perspective of today's increasingly high data traffic is that besides it is being widely accepted that the high bandwidth L TE provides is creating bottlenecks for service providers by the increasing user bandwidth demands without creating any corresponding revenue improvements, a hidden problem that is also passively advancing on the newly emerging 4G-LTE that may need more immediate attention is the network signaling traffic, also known as the control-plane traffic that is generated by the applications developed for smartphones and tablets. With this as starting point, in this paper, we propose a solution, by a new approach considering OpenFlow switch connected to a controller, which gains flexibility in policy, costs less, and has the potential to be more robust to failure with future generations of switches. This also solves the problem of scaling the control-plane traffic that is imperative to preserve revenue and ensure customer satisfaction. Thus, with the proposed architecture with OpenFlow, mobile network operators could manipulate the traffic generated by the control-plane signaling separated from the data-plane, besides also reducing the cost in installing multiple core-network entities.

오픈 소스 기반의 아두이노를 이용한 건조기 내 유기 시료의 실시간 수분측정 모니터링에 관한 연구 (A Study on Real-Time Monitoring for Moisture Measurement of Organic Samples inside a Drying Oven using Arduino Based on Open-Source)

  • 김정훈
    • 벤처혁신연구
    • /
    • 제5권2호
    • /
    • pp.85-99
    • /
    • 2022
  • 시판되고 있는 실험용 및 산업용 건조기는 일반 드라이오븐, 열풍 순환 건조기, 진공건조기, 동결건조기 등으로 구분되고 기능, 크기 및 용량 등에 따라 그 종류도 다양하다. 그러나 제품의 품질 제어 및 성능 개선을 위해 중요한 요소인 수분측정이 적용되지 않아 현재는 건조 종료 후 임의로 중량을 칭량하기 때문에 매우 수동적이다. 일반적으로 수분을 측정하기 위한 방법은 직접적인 측정법과 간접적인 측정법으로 구분되고 수분 분리 전.후의 질량 또는 부피 변화와 같은 직접적인 측정법이 주로 이용된다. 상대적으로 열전도도, 마이크로파 등과 같은 간접적인 측정법은 측정 장비를 활용하기 때문에 적용이 제한적이다. 본 연구에서는 오픈소스 기반의 아두이노를 이용하여 비교적 손쉽게 수분측정 시스템을 설계하여 외부 환경요인에 영향 받지 않고 수분 변화량 및 무게 변화를 실시간으로 모니터링 하였다. 구체적으로 수분 민감도 물질 및 식품 건조에 적합한 60℃와 80℃에서 작동할 수 있는 온.습도 및 로드셀 측정 센서를 건조기 내부에 패키징하여 각종 변화량을 측정하였다. 또한 바나나, 배, 톱밥의 유기 시료를 이용한 반복적인 실험을 통해서도 건조시간 및 온도에 따른 증발율 변화와 로드셀 측정값에 있어 안정적인 응답특성을 나타냄으로써 성능 안전성을 확보할 수 있었다. 향후 온.습도 범위의 확대와 CFD(Computational Fluid Dynamics) 프로그램과의 비교 분석을 통해 신뢰도를 더욱 향상시킬 수 있을 것으로 판단된다.

송전용 폴리머 애자에 대한 산불 영향 평가 (The Influence of Forest Fire on the Polymer Insulator for Transmission Lines)

  • 최인혁;이동일;이철호;강병규;이원교;박준호
    • 한국전기전자재료학회논문지
    • /
    • 제20권9호
    • /
    • pp.787-792
    • /
    • 2007
  • To understand the effects of forest fires on polymer insulators for transmission lines, the forest fire simulation tests were performed with polymer and porcelain insulators at Gochang testing center. These tests consisted of energizing 90 kV at line-to-ground voltage of 154 kV lines and open flame rising up to $600-630^{\circ}C$ as being measured at insulator surface. Mechanical and electrical characteristics such as specific mechanical load, leakage current, low frequency dry flashover voltage and impulse flashover voltage were analyzed for the polymer insulators before, during and after simulation tests compared with porcelain insulators. At the end of fire simulation tests, there was no detrimental deterioration of any insulators. All insulators passed the criteria of KEPCO specification. This study showed that forest fire simulation had no impact on polymer insulators.

Study on the effect of ties in the intermediate length Cold Formed Steel (CFS) columns

  • Anbarasu, M.;Kumar, S. Bharath;Sukumar, S.
    • Structural Engineering and Mechanics
    • /
    • 제46권3호
    • /
    • pp.323-335
    • /
    • 2013
  • This work aims to study the effect of stiffener ties in the behavior of intermediate length open section Cold-Formed Steel (CFS) Columns under axial compression. A comparative study on the behaviour and strength of Cold Formed Steel Columns by changing the direction of projection of lips (i.e., inwards or outwards) are also done. In this work two types of sections were considered Type-I section with lip projecting outwards (hat) and Type-II section with lip projecting inwards (channel). The length of the columns is predicted by performing elastic buckling analysis using CUFSM software. The theoretical analysis is performed using DSM - S100;2007, AS/NZ: 4600-2005 and IS: 801-1975. The compression tests are carried out in a 400 kN loading frame with hinged-hinged end condition. The non-linear numerical analysis is performed using Finite Element software ANSYS 12.0 to simulate the experimental results. Extensive parametric study is carried out by varying the width and spacing of the stiffener ties. The results are compared; the effects of stiffener ties on behaviour and load carrying capacity on both types of columns are discussed.

Bending of a cracked functionally graded nanobeam

  • Akbas, Seref Doguscan
    • Advances in nano research
    • /
    • 제6권3호
    • /
    • pp.219-242
    • /
    • 2018
  • In this study, static bending of an edge cracked cantilever nanobeam composed of functionally graded material (FGM) subjected to transversal point load at the free end of the beam is investigated based on modified couple stress theory. Material properties of the beam change in the height direction according to exponential distributions. The cracked nanobeam is modelled using a proper modification of the classical cracked-beam theory consisting of two sub-nanobeams connected through a massless elastic rotational spring. The inclusion of an additional material parameter enables the new beam model to capture the size effect. The new non-classical beam model reduces to the classical beam model when the length scale parameter is set to zero. The considered problem is investigated within the Euler-Bernoulli beam theory by using finite element method. In order to establish the accuracy of the present formulation and results, the deflections are obtained, and compared with the published results available in the literature. Good agreement is observed. In the numerical study, the static deflections of the edge cracked FGM nanobeams are calculated and discussed for different crack positions, different lengths of the beam, different length scale parameter, different crack depths, and different material distributions. Also, the difference between the classical beam theory and modified couple stress theory is investigated for static bending of edge cracked FGM nanobeams. It is believed that the tabulated results will be a reference with which other researchers can compare their results.