• Title/Summary/Keyword: Open-Loop control

Search Result 457, Processing Time 0.032 seconds

6-Axes Articulated Robot Manipulator's Gain Tuning in consideration of dynamic specific (수직 다관절 로봇의 동적 특성을 고려한 Gain Tuning 연구)

  • Chung W.J.;Kim H.G.;Kim K.J.;Kim K.T.;Seo Y.G.;Lee K.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.744-747
    • /
    • 2005
  • This research studied 6-Axes Articulated Robot Manipulator's gain Tuning in consideration of dynamic. First of all, search fur proportional gain of velocity control loop by dynamic signal analyzer. Proportional gain of velocity control loop is connected to dynamic signal analyzer. Next Select free Proportional Gain value. And Select amplitude X of sinusoidal properly so that enough Velocity Feedback Signal may be paid as there is no group to utensil department. Next step, We can get Bode Diagram of Closed loop transfer function response examination in interested frequency. Integral calculus for gain of velocity loop is depended on integral calculus correction's number. We can obtain open loop transfer function by integrator. And we can know bode diagram's special quality from calculated open loop transfer function. With this, Velocity Control Loop's Parameter as inner loop is controlled. Next In moving, when vibration occurs, it controls notch filter. And finally, we have to control fred-forward filter parameter for elevation of control performance.

  • PDF

A Heuristic Approach for Grading Operation of Hydraulic Excavator Systems using SMISMO Valve Configuration (SMISMO 밸브 구조를 채용한 유압식 굴삭기의 평탄화 작업을 위한 휴리스틱 접근)

  • Joh, Joongseon;Hwang, Cheol Min
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.11
    • /
    • pp.1153-1160
    • /
    • 2013
  • SMISMO valve configuration is now starting to draw attention of the researchers of the construction equipment industry to increase the fuel efficiency of their equipment like excavators and wheel-loaders. An open-loop control strategy for grading operation of hydraulic excavator systems using SMISMO valve configuration is investigated in this paper. Tabor's algorithm for 1 d.o.f. SMISMO system under the assumption of quasi-static operation is revealed as not adequate for multi d.o.f. system with large moment of inertia even though the motion of the system is slow. New parameters are proposed in this paper. It modifies Tabor's open-loop control strategy for the grading operation of hydraulic excavators using SMISMO valve configuration. A simulation-based parameter tuning method is also proposed. It uses GA (Genetic Algorithm) to find the best parameter values. Simulation study for a practical hydraulic excavator shows the validity of the proposed open-loop control strategy.

Performance Comparison of Three Different Types of Attitude Control Systems of the Quad-Rotor UAV to Perform Flip Maneuver

  • Lee, Byung-Yoon;Yoo, Dong-Wan;Tahk, Min-Jea
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.14 no.1
    • /
    • pp.58-66
    • /
    • 2013
  • This paper addresses the performance of three different types of attitude control systems for the Quad-rotor UAV to perform the flip maneuver. For this purpose, Quad-rotor UAV's 6-DOF dynamic model is derived, and it was used for designing an attitude controller of the Quad-rotor UAV. Attitude controllers are designed by three different methods. One is the open-loop control system design, another is the PD control system design, and the last method is the sliding mode control system design. Performances of all controllers are tested by 6-DOF simulation. In case of the open-loop control system, control inputs are calculated by the quad-rotor dynamic model and thrust system model that are identified by the thrust test. The 6-DOF realtime simulation environment was constructed in order to verify the performances of attitude controllers.

Vibrational Control of an Underactuated Mechanical System : Control Design Using the Averaging Method (불충분한 작동기를 가진 기계시스템의 진동적제어: 평균화기법을 통한 제어 설계)

  • 이강렬;홍금식;이교일
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.534-537
    • /
    • 1995
  • An open loop vibrational control of underactuated mechanical system with amplitude and frequency modulations is investigated. The underactuated systems sonsidered in the paper are assumed to have free joints with no brake. The active joints are positioned first by a linearizing control, and then periodic oscillatory input are applied to them to move the remaining free joints to their desired states. A systematic way of obtaining averaged systems for the underactuated systems with oscillatory vibration is developed. A complete solution to the open loop control strateegy in terms of determining amplitudes and frequencies for general system is still under investigation. However, a specific control design for 2R manipulator which is obtained through the averaged system is demonstrated.

  • PDF

A Modified Microstep Drive of PM Step Motor (PM 스텝 모터의 개선된 마이크로 스텝 구동)

  • Lee, Tae-Gyoo;Shin, Ki-Sang;Huh, Uk-Youl
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.15-17
    • /
    • 1996
  • In this paper, a modified microstep drive of PM step motor is presented. The open-loop drive of a step motor is attractive and widely accepted in applications of speed and position controls. However, the performance of the step motor is limited under the open-loop drive. The closed-loop control is advantages over the open-loop control not only in that step failure never occurs but that the motion is much quicker and smoother. However, a high resolution sensor is needed for detecting position and speed. The modified microstep drive is constructed as a microstep drive with speed feedback. The advantages of the proposed method is that the controller can be designed by a low resolution sensor and is simpler than other closed-loop controller. A concept of vector control is used for verifying the proposed scheme. Simulations show the performance of the proposed method and a comparison with a classic drive method.

  • PDF

The Implementation of Train Diagram Modeling in the Open-loop Metro Line (Open-loop Metro Line에서의 열차 운전도 모델링의 구현)

  • Hong, H.S.;Yoo, K.K.;Lee, T.S.;Moon, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.527-530
    • /
    • 1995
  • In this paper, traffic modeling and control design was considered to analyze and improve the stability of train diagram in the open-loop Metro line. A complete discrete-event traffic model describing the natural instability of open-loop metro line is analyzed. The traffic stability properties are introduced and easy-to-implement state feed back traffic control algorithms are designed, which satisfied with system stability.

  • PDF

An Effect of Car Performance Influenced to Absorbing Resistane of Air-cleaner Filter for the L. P. G Vehicle of Open Loop Fuel System (Open Loop 연료공급계의 L. P. G 차량에서 공기청정기 필터의 흡기저항이 차량성능에 미치는 영향)

  • Shin, Yong-Wha;Kim, Ki-Hyung;Jung, Jong-An
    • Journal of the Korean Society of Safety
    • /
    • v.10 no.4
    • /
    • pp.36-46
    • /
    • 1995
  • The interest and purpose of this study is to control of air-fuel ratio and develop control device of a spark ignition LPG engine with adopting open loop fuel system. The air-fuel ratio is derived by considering airflow resistane of air cleaner element. The result shows that air-fuel ratio becomes more and more rich when airflow resistance increases. Experiments about the influence of airflow resistance on the engine performance, drivability and emissions are performed. Therefore, it is known that open-loop fuel system depends on the absorbing resistance of air-cleaner.

  • PDF

Design of Closed Loop Pipe Cooling System (냉각수 순환 형태의 파이프 쿨링 공법의 설계)

  • 박찬규;왕인수;구자중
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2001.11a
    • /
    • pp.52-57
    • /
    • 2001
  • In order to control hydration heat in mass concrete, pipe cooling method has been widely used. The pipe cooling method leads to the decrease of curing period by lagging materials as well as the decrease of temperature difference between center and surface of mass concrete member, There are two methods in the pipe cooling system, which are open loop system and closed loop system. However open loop pipe cooling system cannot be applied to the mass concrete structures when cooling water supply is difficult. To control hydration heat of high strength mass foundation in the central area of city, closed loop pipe cooling system was developed to solve the cooling water supply. This paper reports the performance results of hydration heat control with closed loop pipe cooling system.

  • PDF

Performance analysis of feedback controller for vibratory gyroscope at various vacuum levels

  • Sung, Woon-Tahk;Lee, Jang-Gyu;Kang, Tae-Sam
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1537-1541
    • /
    • 2003
  • In this paper, presented is a feedback control performance of vibratory gyroscope at various vacuum levels. Micro gyroscope, whose operation is based on the vibrating motion at the vacuum conditions, is highly influenced by the vacuum level of the operating circumstances. In general, we apply the feedback control scheme to the gyroscope in order to improve the performances of the sensor. And control performances of the gyroscope are related to those vacuum levels. So we need investigate the performances of the closed loop control at various vacuum conditions comparing with those of the open loop. The experimental results show that the sensitivity of the closed loop is less than that of the open loop especially in low vacuum conditions. Therefore, there should be trade-off between sensitivity and other sensor performances such as linearity, bandwidth when we apply feedback control to the gyroscope.

  • PDF

The Mold Close and Open Control of Injection Molding Machine Using Fuzzy Algorithm

  • Park, Jin-Hyun;Lee, Young-Kwan;Kim, Hun-Mo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.575-579
    • /
    • 2005
  • In this paper, the development of an IMM(Injection Molding Machine) controller is discussed. Presently, the Mold Close and Open Control Method of a toggle-type IMM is open-loop control. Through the development, a PC based control system was built instead of an existing controller and a closed-loop control replaced the previous control method by using PC based PLC. To control the nonlinear system of toggle type clamping unit, a fuzzy PI control algorithm was selected and it was programmed by an IL(Instruction List) and a LD(Ladder Diagram) on a PC based PLC. The application of fuzzy algorithm as the control method was also considered to change a control object like a mold replacement or an additional apparatus. For the development of an IMM controller, PC based PLC of PCI card type, distributed I/O modules with CANopen and Industrial PC and HMI (Human Machine Interface) software were used.

  • PDF