A comparative study on the accuracy of impression body according to the types of impression tray (임플란트 인상 채득 시 트레이 종류에 따른 인상체의 정확도에 관한 비교 연구)

  • Yi, Hyun-Jung;Lim, Jong-Hwa;Lee, Joon-Seok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.1
    • /
    • pp.48-54
    • /
    • 2010
  • Purpose: The objective of this study was to evaluate and compare the accuracy of impression body taking by the closed and the open tray impression technique with 3 types of impression tray. Individual tray, metal stock tray and polycarbonate tray were used. Materials and methods: Nine closed tray impressions were taken by individual tray, metal stock tray and polycarbonate stock tray, respectively with polyether impression material. 9 open tray impressions were also acquired by same manner. Precision analysis on the master models was performed by attaching the reference frameworks with alternate single screws and measuring the vertical fit discrepancy of respective analogues in working cast with a stereo microscope. Data were analyzed by 1 way ANOVA and independent t-test. Results: The average fit accuracy of impression bodies was calculated. With the closed tray impression technique, there were significant statistical differences in vertical fit discrepancy according to the types of tray. The individual tray group showed the lowest value and the polycarbonate stock tray group represented the highest. With the open tray impression technique, there was no significant difference in vertical fit discrepancy. Significant statistical difference in vertical fit discrepancy was found between the open and the closed impression technique with the polycarbonate stock tray. Conclusion: From the results above, more precise impressions could be acquired by the rigid individual tray compared with the polycarbonate stock tray. It was hard to get consistent accuracy impressions by the closed tray impression technique with polycarbonate stock trays.

Building Open API Ontologies based (ll Semantics for Smart Mashup (스마트 매쉬업을 위한 시맨틱 기반 Open API 온톨로지 구축 기법)

  • Lee, Yong Ju
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.7 no.3
    • /
    • pp.11-23
    • /
    • 2011
  • Recently, Open APIs are getting attention with the advent of Web 2.0. Open APIs are used to combine services and generate new services by Mashup. However, the growing number of available Open APIs raises a challenging issue how to locate the desired APIs. We automatically build ontologies from WSDL, WADL, HTML, and their underlying semantics. The key ingredient of our method is a technique that clusters input/output parameters in the collection of API methods into semantically meaningful concepts, and captures the hierarchical relationships between the terms contained in a parameter. These semantic ontologies allow search engines to support a similarity search for Open APIs based on various protocols such as SOAP, REST, JavaScript, and XML-RPC, and significantly improve the quality of APIs matching by the clustering and hierarchical relationships mechanism.

RADIOGRAPHIC ANALYSIS OF THE TEMPOROMANDIBULAR JOINT BY THE STANDARDIZED PROJECTION TECHNIQUE (악관절규격촬영법에 의한 과두위의 분석 연구)

  • Choe Han Up
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.13 no.1
    • /
    • pp.7-15
    • /
    • 1983
  • The purpose of this study was to investigate the radiographic images of the condylar head in clinically normal subjects and the TMJ patients using standardized projection technique. 45 subjects who have not clinical evidence of TMJ problems and 96 patients who have the clinical evidence of TMJ problems were evaluated, but the patients who had fracture, trauma and tumor on TMJ area were discluded in this study. For the evaluation of radiographic images, the author has observed the condylar head positions in closed mouth and 2.54㎝ open mouth position taken by the standardized transcranial oblique lateral projection technique. The results were as follows: 1. In closed mouth position, the crest of condylar head took relatively posterior position to the deepest point of the glenoid fossa in 8.9 % of the normals and in 26.6% of TMJ patients. 2. In 2.54㎝ open mouth position, condylar head took relatively posterior position to the articular eminence in 2.2% of TMJ patients and 39.6% of the normals. 3. In open mouth position, the horizontal distance from the deepest point of the glenoid fossa to the condyla head was 13.96㎜ in the normals and 10.68㎜ in TMJ patients. 4. The distance of true movement of condyalr head was 13.49㎜ in the normals and l0.27㎜ in TMJ patients. 5. The deviation of mandible in TMJ patients was slightly greater than that of the normals.

  • PDF

Open Intramedullary Nail with Tension Band Sutures on Proximal Humeral Fracture (상완골 근위부 골절에 시행한 긴장 대 봉합을 동반한 관혈적 골수강내 고정술)

  • Park, Jin-Young;An, Jin-Woo;Lee, Sung-Churl
    • Clinics in Shoulder and Elbow
    • /
    • v.6 no.2
    • /
    • pp.149-160
    • /
    • 2003
  • Purpose: to determine the results after open intramedullary nailing and tension band suture technique in proximal humerus fracture for improving the stability and decreasing the complications. Materials and Method: Authors reviewed 27 patients treated by open intramedullary nailing and tension band suture technique. Mean follow-up period was 39 months (24-59months). Surgical neck fracture were 6 cases, surgical neck fracture with shaft fracture were 3 cases, three part fracture with greater tuberosity fracture were 17 cases, four part fracture was 1 case and fracture and dislocation were 2 cases Results: We got the bony union in 26 cases. Average pain scale was 1 point (0-6), Neer score was 86 point(45-99) and ASES score was 85 point(40-100). We separate all cases in two groups based on age (65 years), L-spine t-score (-2.5) and Neer classification (2 and 3 part). There is no significance in pain scale, Neer score and ASES score between each group. Conclusion: As a method of surgical treatment on severe proximal humeral fractures, we recommend intramedullary nailing and tension band suture technique and it may have particular advantages in early exercise and satisfactory functional outcome.

Design of a Binding for the performance Improvement of 3D Engine based on the Embedded Mobile Java Environment (자바 기반 휴대용 임베디드 기기의 삼차원 엔진 성능 향상을 위한 바인딩 구현)

  • Kim, Young-Ouk;Roh, Young-Sup
    • Journal of Korea Multimedia Society
    • /
    • v.10 no.11
    • /
    • pp.1460-1471
    • /
    • 2007
  • A 3-Dimensional engine in a mobile embedded device is divided into a C-based OpenGL/ES and a Java-based JSR184 which interprets and executes a byte code in a real-time. In these two standards, the JSR184 supporting Java objects uses more processor resources than an OpenGL/ES and thus has a constraint when it is used in an embedded device with a limited computing power. On the other hand, 3-Dimensional contents employed in existing personal computer are created by utilizing advantages of Java and secured numerous users in European market, due to the good quality in contents and extensive service in a commercial network, GSM. Because of the reason, a mobile embedded device used in a GSM network needs a JSR184 which can provide an existing Java-based 3-Dimensional contents without extra conversion processes, but the current version of Java-based 3-Dimensional engine has drawbacks in application to commercial products because it requires more computing power than the mobile embedded device. This paper proposes a binding technique with the advantages of Java objects to improve a processing speed of 3-Dimensional contents in limited resources of a mobile embedded device. The technique supports a JSR184 standard interface in the upper layer to utilize 3-Dimensional contents using Java, employs a different code-conversion language, KNI(Kilo Native Interface), in the middle layer to interface between OpenGL/ES and JSR184, and embodies an OpenGL/ES standard in the lower layer. The validity of the binding technique is demonstrated through a simulator and a FPGA embedding an ARM.

  • PDF

Implementation of an OpenFlow-based Access Point Virtual Switch for Monitoring and Virtualization of Legacy Wireless LAN

  • Lee, Hyung-Bong;Park, Ji-Hoon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.21 no.1
    • /
    • pp.65-72
    • /
    • 2016
  • Network virtualization is an emerging technology for solving the rigidity of the physical network infrastructure. The innovative technique virtualizes all resources in the network, including the network links and nodes, and provides a number of virtual networks on a single network infrastructure. In order to realize a virtual network, a thorough and complete monitoring of all resources in the network should be performed firstly. OpenFlow is an open source stack for network virtualization. However, it is impossible to apply OpenFlow to AP-based legacy wireless LAN environment because OpenFlow targets ethernet-based LAN environment. In this paper, we implement an adaptor-styled virtual switch for AP-based wireless LAN through customizing the Open vSwitch which is a virtual switch of OpenFlow. The evaluation test results show that the implemented OpenFlow stack operates successfully. The implemented OpenFlow stack can now be plugged immediately in existing AP-based wireless LAN environment and plays network resource monitoring. In the future, we can develop wireless LAN virtualization applications on the wireless OpenFlow stack.

The Effectiveness of Vacuum-Assisted Closure (V.A.C) Dressing combined with Silver Dressing Material in Open Fracture of the Foot and Ankle (족부 및 족관절의 개방성 골절 환자에서 음압 치료와 실버 드레싱 제재 복합 치료의 유용성)

  • Lee, Yu-Sang;Cho, Jae-Ho;Park, Jin;Han, Seung-Hwan
    • Journal of Korean Foot and Ankle Society
    • /
    • v.12 no.2
    • /
    • pp.156-162
    • /
    • 2008
  • Purpose: Open fractures of the foot and ankle require prompt repair of the wound due to the complexity of anatomy, insufficiency of soft tissues and inadequate blood supply. Early flaps and skin grafts are used for this purpose yet general condition of the patient as well as local wound environment often precludes such treatment options. Vacuum- Assisted Closure (VAC) is recently being used in such cases. This study was done to validate the use of VAC together with silver antimicrobial dressing materials in contaminated open fracture wounds. Materials and Methods: We have selected 10 patients with Gustillo-Anderson type III open fractures of the foot & ankle treated with VAC and silver antimicrobial dressing materials from March 2007 to January 2008. The relationship between duration of treatment with wound size, contamination, and degree of soft tissue damage was analyzed. Results: The average age of patients was 36.6 years. The average amount of VAC application time was 23.4 days. Silver dressing materials were used for 16.8 days. Average wound healing time was 51.9 days. Statistically significant relationship was found between wound size, VAC application time and silver dressing material application time. No complications such as osteomyelitis were found after treatment. Conclusion: VAC technique is recently being used in open fractures with wide skin and soft tissue defects, producing good results. A wide array of dressing materials such as silver dressing is in development. We have incorporated the VAC technique together with silver dressing materials in the treatment of open fractures and achieved complication free results.

  • PDF

Outcomes of Closed versus Open Rhinoplasty: A Systematic Review

  • Gupta, Rohun;John, Jithin;Ranganathan, Noopur;Stepanian, Rima;Gupta, Monik;Hart, Justin;Nossoni, Farideddin;Shaheen, Kenneth;Folbe, Adam;Chaiyasate, Kongkrit
    • Archives of Plastic Surgery
    • /
    • v.49 no.5
    • /
    • pp.569-579
    • /
    • 2022
  • Open and closed rhinoplasty are two main approaches to perform nasal modifications. According to current literature, there is no current consensus among plastic surgeons and otolaryngologists on which technique is preferred in terms of aesthetic result, complications, and patient satisfaction. This study uses published research to determine whether open or closed rhinoplasty leads to superior patient outcomes. Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines for systematic reviews were followed and a literature search was conducted in four databases based on our search strategy. Articles were then imported into COVIDENCE where they underwent primary screening and full-text review. Twenty articles were selected in this study after 243 articles were screened. There were 4 case series, 12 retrospective cohort studies, 1 prospective cohort study, 1 case-control, and 2 outcomes research. There were three cosmetic studies, eight functional studies, and nine studies that included both cosmetic and functional components. Sixteen studies utilized both open and closed rhinoplasty and four utilized open rhinoplasty. Both techniques demonstrated high patient and provider satisfaction and no advantage was found between techniques. Based on available studies, we cannot conclude if there is a preference between open or closed rhinoplasty in terms of which technique leads to better patient outcomes. Several studies determined that open rhinoplasty and closed rhinoplasty leads to comparative patient satisfaction. To make outcome reporting more reliable and uniform among studies, authors should look to utilize the Nasal Obstruction and Septoplasty Effectiveness scale and the Rhinoplasty Outcome Evaluation.

Judgement in artificial eruption of embedded teeth from an oral surgery perspective: review article

  • Mahardawi, Basel;Kumar, KC;Arunakul, Kanin;Chaiyasamut, Teeranut;Wongsirichat, Natthamet
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.46 no.1
    • /
    • pp.12-18
    • /
    • 2020
  • Impacted teeth are a frequent phenomenon encountered by every clinician. The artificial eruption of embedded teeth is the process of directing an impacted tooth into normal occlusion. This procedure is currently attracting attention, with the aim of finding the best technique to use according to each case. This article presents key information regarding impacted incisors, canines, and premolars. In addition, we describe the most common techniques to use for artificial eruption, the open and closed techniques. We review the literature concerning these techniques and outline how clinicians can manage every type of impacted tooth.