• Title/Summary/Keyword: Open circuit

Search Result 1,163, Processing Time 0.141 seconds

Determination of Critical Chloride Content of Ordinary Portland Cement Concrete by Linear Polarization Technique (선형분극법을 이용한 보통프틀랜드시멘트 콘크리트의 임계염화물량)

  • Kim, Hong-Sam;Cheong, Hai-Moon;Ahn, Tae-Song
    • Journal of the Korean Ceramic Society
    • /
    • v.44 no.9
    • /
    • pp.524-528
    • /
    • 2007
  • The results of evaluating steel corrosion in concrete containing chloride content of various levels indicated that the more chloride content in concrete leads to the lower potential and higher corrosion current density. However, the open circuit potential of steel varied with time and exposure condition, and the corelation between the open circuit potential and corrosion current density was not obvious. In order to determine the critical threshold content of chloride of steel corrosion in concrete, the concept of average corrosion current density was employed. The range of critical chloride content in portland cement concretes was about $1.56{\sim}1.77%$($Cl^-$, %, wt of cement content) along with water-cement ratio, and higher water-cement ratio resulted in reduction in critical threshold chloride content.

State of Charge Estimation of Li-Ion Battery Based on CIM and OCV Using Extended Kalman Filter (전류적산법과 OCV 방법을 결합한 Li-Ion 배터리의 충전상태 추정)

  • Park, Joung-Ho;Cha, Wang-Cheol;Cho, Uk-Rae;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.11
    • /
    • pp.77-83
    • /
    • 2014
  • The Estimation of State of Charge(SOC) for batteries is an important aspect of a Battery Management System(BMS). A method for estimating the SOC is proposed in order to overcome the individual disadvantages of the current integral and Open Circuit Voltage(OCV) estimation methods by combining them using Extended Kalman filter(EKF). The non-linear characteristics of the Li-Ion RC battery model used in this study is also solved through EKF. The proposed method is simulated in a Matlab environment with a Li-Ion Kokam battery (3.7V, 1,500mAh). Results showed that there is an improvement in the estimation error when using the proposed model compared to the conventional current integral method.

An Open Circuit Fault Diagnostic Technique in IGBTs for AC to DC Converters Applied in Microgrid Applications

  • Khomfoi, Surin;Sae-Kok, Warachart;Ngamroo, Issarachai
    • Journal of Power Electronics
    • /
    • v.11 no.6
    • /
    • pp.801-810
    • /
    • 2011
  • An open circuit fault diagnostic method in IGBTs for the ac to dc converters used in microgrid applications is developed in this paper. An ac to dc converter is a key technology for microgrids in order to interface both distributed generation (DG) and renewable energy resources (RES). Also, highly reliable ac to dc converters are necessary to keep converters in continuous operation as long as possible during power switch fault conditions. Therefore, the proposed fault diagnostic method is developed to reduce the fault detection time and to avoid any other fault alarms because continuous operation is desired. The proposed diagnostic method is a combination of the absolute normalized dc current technique and the false alarm suppression algorithm to overcome the long fault detection time and fault alarm problems. The simulation and experimental results show that the developed fault diagnostic method can perform fault detection within about one cycle. The results illustrate that the reliability of an ac to dc converter interfaced with a microgrid can be improved by using the proposed fault diagnostic method.

Dynamic Characteristics of Moving Coil Type Linear Oscillatory Actuator (가동코일형 리니어 왕복 액추에이터의 동특성)

  • Jang, S.M.;Jeong, S.S.;Kweon, C.;Park, H.C.;Moon, S.J.;Park, C.I.;Chung, T.Y.
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.3
    • /
    • pp.180-187
    • /
    • 2000
  • A moving-coil-type linear oscillatory actuator(LOA) consists of the NdFeB permanent magnets with high specific energy as the stator, a coil-wrapped nonmagnetic hollow rectangular structure. The LOA system was represented by the voltage equation of coil and the mechanical equation of motion. This set of equations was manipulated in state-space form. The EMF constant kE of equation parameters in state-space form can be obtained by using the induced voltage in armature coils at open circuit test. kE and other parameters provide the system matrices and transfer function for frequency response and dynamic simulation. Voltage source inverter-fed LOA is examined aiming to compare with results of simulation.

  • PDF

Anode-supported Type SOFCs based on Novel Low Temperature Ceramic Coating Process

  • Choi, Jong-Jin;Ahn, Cheol-Woo;Kim, Jong-Woo;Ryu, Jungho;Hahn, Byung-Dong;Yoon, Woon-Ha;Park, Dong-Soo
    • Journal of the Korean Ceramic Society
    • /
    • v.52 no.5
    • /
    • pp.338-343
    • /
    • 2015
  • To prevent an interfacial reaction between the anode and the electrolyte layer during the conventional high-temperature co-firing process, an anode-supported type cell with a thin-film electrolyte was fabricated by low-temperature ceramic thick film coating process. Ni-GDC cermet composite was used as the anode material and YSZ was used as the electrolyte material. Open circuit voltage and maximum power density were found to strongly depend on the surface uniformity of the anode functional layer. By optimizing the microstructure of the anode functional layer, the open circuit voltage and maximum powder density of the cell increased to 1.11 V and $1.35W/cm^2$, respectively, at $750^{\circ}C$. When a GDC barrier layer was applied between the YSZ electrolyte and the LSCF cathode, the cell showed good stability, with almost no degradation up to 100 h. Anode-supported type SOFCs with high performance and good stability were fabricated using a coating process.

Evaluation of Solar Cell Properties of Poly-Si Thin Film Fabricated with Novel Process Conditions for Solid Phase Crystallization (고상 결정화법을 위한 새로운 공정조건으로 제작된 다결정 Si 박막의 태양전지 특성 평가)

  • Kweon, Soon-Yong;Jeong, Ji-Hyun;Tao, Yuguo;Varlamov, Sergey
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.9
    • /
    • pp.766-772
    • /
    • 2011
  • Amorphous Si (a-Si) thin films of $p^+/p^-/n^+$ were deposited on $Si_3N_4$/glass substrate by using a plasma enhanced chemical vapor deposition (PECVD) method. These films were annealed at various temperatures and for various times by using a rapid thermal process (RTP) equipment. This step was added before the main thermal treatment to make the nuclei in the a-Si thin film for reducing the process time of the crystallization. The main heat treatment for the crystallization was performed at the same condition of $600^{\circ}C$/18 h in conventional furnace. The open-circuit voltages ($V_{oc}$) were remained about 450 mV up to the nucleation condition of 16min in the nucleation RTP temperature of $680^{\circ}C$. It meat that the process time for the crystallization step could be reduced by adding the nucleation step without decreasing the electrical property of the thin film Si for the solar cell application.

A study on the method of manufacturing $TiO_2$ photoelectrode for improving the photocurrent of dye-sensitized solar cells (염료감응형 태양전지 광전류 향상을 위한 $TiO_2$ 광전극 제작방법에 관한 연구)

  • Baek, Hyung-Ryul;Han, Zhen-Ji;Park, Kyung-Hee;Gu, Hal-Bon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.354-355
    • /
    • 2006
  • We manufactured photoelectrode of dye-sensitized solar cells (DSC) by using three methods such as squeeze method, spray method, and combination method (squeeze method first, spray method second). We examined how the morphology of an electrode's surface, the pore between particles, and condensation have an effect on an open-circuit voltage, photocurrent, fill factor, and energy conversion efficiency. Open-circuit voltage of dye-sensitized solar cells manufactured by using three methods is about 0.66V when the photoelectrode of the three DSCs is about $5{\mu}m$ thick. Photocurrent and fill factor and conversion efficiency of DSC manufactured by using squeeze method is 18.5 and 34 and 7.8, respectively. Photocurrent and fill factor and conversion efficiency of DSC manufactured by using spray method is 3.62 and 62 and 2.8, respectively. Photocurrent and fill factor and conversion efficiency of DSC manufactured by using combination method is 10.7 and 46 and 5.9, respectively. In conclusion, we find that the combination method is better than the other two methods in such respects as energy conversion efficiency and fill factor.

  • PDF

Ammonia neutralization and removal using electrolyzed-acidic water (전해산성수를 이용한 암모니아 중화와 제거)

  • Choi, Weon-Kyung
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.5
    • /
    • pp.185-190
    • /
    • 2021
  • An electrolyzed-acidic water treatment was investigated as a methods for removing ammonia, which is a cause of odor in life environment. The prepared electrolyzed-acidic water was found out as stable solvent capable of neutralizing weak alkaline ammonia by measuring changes in pH and ORP. It was found out that ammonia was removed from the mixture solution of electrolyzed-acidic water and ammonia water by the UV-vis absorbance analysis and electrochemical open-circuit potential measurement. The neutralized ammonia by electrolyzed-acidic water and effectively removed odor was measured using ammonia gas detecter. Consequently, we recommend the electrolyzed-acidic water can effectively and safely remove ammonia in eco-friendly.

Degradation diagnosis of parallel-connected lithium-ion battery cells via non-constructive electrochemical approach (병렬 연결된 리튬이온전지 셀의 비파괴 전기화학적 열화상태 진단)

  • Lee, Garam;Jeong, Jiyoon;Kim, Yong-Tae;Choi, Jinsub
    • Journal of the Korean institute of surface engineering
    • /
    • v.55 no.4
    • /
    • pp.231-235
    • /
    • 2022
  • As environmental pollution becomes more serious, the demand for electric vehicles (EVs) and lithium-ion batteries for electric vehicles is rapidly increasing worldwide. Accordingly, the amount of waste batteries is also increasing, and a technology for recycling and reusing them is required. In order to reuse a used battery, it is necessary to non-destructively diagnose the deterioration condition of the battery. Therefore, in this study, we investigate the diagnosis of degradation for parallel-connected lithium-ion battery cells through non-constructive electrochemical approach. As the number of parallel-connected cells increased, in addition to linear degradation, abrupt step-like degradation occurred, which is attributed to the predominant degradation of specific cells. In addition, it is confirmed that deteriorated cells among multiple cells can be distinguished through a simple measurement of open circuit voltage (OCV).

Corrosion Resistance Evaluation of Aluminum Thermal Spray Coated AA5083-H321 (알루미늄 열용사 코팅된 AA5083-H321의 내식성 평가)

  • Il-Cho Park;Sungjun Kim;Min-Su Han
    • Corrosion Science and Technology
    • /
    • v.22 no.2
    • /
    • pp.108-114
    • /
    • 2023
  • In this study, anti-corrosion effect was investigated through various electrochemical experiments after applying Al thermal spraying technology to AA5083-H321. Open circuit potential and anodic polarization curves were analyzed through electrochemical experiments in natural seawater. The shape of the surface was observed using a scanning electron microscope (SEM) and a 3D microscope before and after the experiment. Component and crystal structure were analyzed through EDS and XRD. As a result, the surface roughness of AA5083-H321 and the Al thermal sprayed coating layer increased due to surface damage caused by anodic dissolution reaction during the anodic polarization experiment. The corrosion rate of AA5083-H321 was relatively low because the Al thermal spray coating layer contained structural defects such as pores and crevices. Nevertheless, the open circuit potential of the Al thermal spray coating layer in natural seawater was measured about 0.2 V lower than that of AA5083-H321. Thus, a sacrificial anode protection effect can be expected.