• Title/Summary/Keyword: Open Door

Search Result 261, Processing Time 0.026 seconds

A Study on Smoke Movement in Room Fires with Various Pool Fire Location

  • Jeong, Jin-Yong;Ryou, Hong-Sun
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.11
    • /
    • pp.1485-1496
    • /
    • 2002
  • In order to investigate the fire-induced smoke movement in a three-dimensional room with an open door, numerical and experimental study was performed. The center, wall, and corner fire plumes for various sized fires were studied experimentally in a rectangular pool fire using methanol as a fuel. The numerical results from a self-developed SMEP (Smoke Movement Estimating Program) field model were compared with experimental results obtained in this and from literature. Comparisons of SMEP and experimental results have shown reasonable agreement. As the fire strength became larger for the center fires, the air mass flow rate in the door, average hot layer temperature, flame angle and mean flame height were observed to increase but the doorway-neutral-planeheight and the steady-state time were observed to decrease. Also as the wall effect became larger in room fires, the hot layer temperature, mean flame height, doorway-neutral-planeheight and steady-state time were observed to increase. In the egress point of view considering the smoke filling time and the early spread of plume in the room space, the results of the center fire appeared to be more dangerous as compared with the wall and the corner fire. Thus it is necessary to consider the wall effect as an important factor in designing efficient fire protection systems.

Getting On and Off an Elevator Safely for a Mobile Robot Using RGB-D Sensors (RGB-D 센서를 이용한 이동로봇의 안전한 엘리베이터 승하차)

  • Kim, Jihwan;Jung, Minkuk;Song, Jae-Bok
    • The Journal of Korea Robotics Society
    • /
    • v.15 no.1
    • /
    • pp.55-61
    • /
    • 2020
  • Getting on and off an elevator is one of the most important parts for multi-floor navigation of a mobile robot. In this study, we proposed the method for the pose recognition of elevator doors, safe path planning, and motion estimation of a robot using RGB-D sensors in order to safely get on and off the elevator. The accurate pose of the elevator doors is recognized using a particle filter algorithm. After the elevator door is open, the robot builds an occupancy grid map including the internal environments of the elevator to generate a safe path. The safe path prevents collision with obstacles in the elevator. While the robot gets on and off the elevator, the robot uses the optical flow algorithm of the floor image to detect the state that the robot cannot move due to an elevator door sill. The experimental results in various experiments show that the proposed method enables the robot to get on and off the elevator safely.

Unsteady Wind Pressure Analysis on PSD Considering Subway Station Configurations (지하철 역사 형상을 고려한 PSD 비정상 풍압해석)

  • Kim, Yu-Sung;Kim, Yo-Han;Shin, Kwang-Bok;Lee, Eun-Kyu;Kim, Dong-Hyun
    • Journal of the Korean Society for Railway
    • /
    • v.11 no.1
    • /
    • pp.13-18
    • /
    • 2008
  • In this study, unsteady wind pressure analyses on platform screen door (PSD) have been conducted considering the flow intereference effects between the moving train and the configuration of subway station. The major role of PSD prevents passenger accidents, wind pressure, polluted dust and noise when the train is entering the station platform. Computational fluid dynamic method with moving gird algorithm has been adopted to accurately predict unsteady pressure levels exerted on the PSD. Closed and open type station configuration are considered. Also, wind pressure levels for passing and stopping drive motion of the entering train are presented and practically compared each other.

Characterization of household solid waste and current status of municipal waste management in Rishikesh, Uttarakhand

  • Rawat, Suman;Daverey, Achlesh
    • Environmental Engineering Research
    • /
    • v.23 no.3
    • /
    • pp.323-329
    • /
    • 2018
  • The municipal solid waste (MSW) management system in one of the Class II Indian cities i.e. Rishikesh was studied and analysed to identify the key issues in solid waste management in the city. A total of 329 solid waste samples from 47 households were collected to characterize the household solid waste (HSW). The average (HSW) generation rate was 0.26 kg/c/d and it was composed of organic waste (57.3%), plastics (14%), paper (10.9%), and glass and ceramic (1.3%) and other materials (16.5%). There was an inverse relationship between household waste generation rate and family size (p < 0.05). The MSW management system practiced in Rishikesh is unsound. There is no waste segregation at source, no provisions of composting and no recycling by formal sector. The collection and transportation of waste is inadequate and inappropriate. Collected waste is dumped in open dumping site without scientific management. Following are some recommendations for developing a sustainable solid waste management system in Rishikesh city: (1) sensitize people for segregation at source; (2) promote reduction, reuse and recycling of wastes; (3) promote community based composting; (4) provision for 100% door to door collection and; (5) formalize the informal sectors such as rag pickers and recycling industries.

A Flow Analysis of a Refrigeration Warehouse where an Unusual Death of an Operator Occurred by Deficiency of Oxygen

  • Park, Chan-Seong;Moon, Jung-Eun;Kim, Yoon-Ho;Kim, Jin-Pyo
    • International Journal of Safety
    • /
    • v.5 no.2
    • /
    • pp.29-33
    • /
    • 2006
  • A numerical flow analysis of the case of a refrigeration warehouse where an unusual death of an operator occurred by deficiency of oxygen is performed by using STAR-CD program of the computational fluid dynamics (CFD) code. The refrigeration room of the warehouse for storing the fruits maintains an atmosphere of 95% nitrogen and 5% oxygen by volume. When the operator was found dead in the refrigeration room, the room was in normal operating conditions except for the fact that the auxiliary door had been left open. For the flow analysis, unsteady 3-dimensional natural convection with mass transfer is considered. The flow analysis result is compared with the oxygen concentration level measured against time during on-site investigation. The change in oxygen concentration level in the warehouse due to the opening of the auxiliary door is found to be negligible.

Improvement of Formability in Automobile Panels by Variable Blank Holding Force with Consideration of Nonlinear Deformation Path (비선형변형경로를 고려한 가변 블랭크 홀딩력을 통한 자동차 판넬의 성형성 향상)

  • Jeong, Hyun Gi;Jang, Eun Hyuk;Song, Youn Jun;Chung, Wan Jin
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.32 no.11
    • /
    • pp.945-952
    • /
    • 2015
  • In drawing sheet metal, the blank holding force is applied to prevent wrinkling of the product and to add a tensile stress to the material for the plastic deformation. Applying an inappropriate blank holding force can cause wrinkling or fracture. Therefore, it is important to determine the appropriate blank holding force. Recent developments of the servo cushion open up the possibility to reduce the possibility of fracture and wrinkling by controlling the blank holding force along the stroke. In this study, a method is presented to find the optimal variable blank holding force curve, which uses statistical analysis with consideration of the nonlinear deformation path. The optimal blank holding force curve was numerically and experimentally applied to door inner parts. Consequently, it was shown that the application of the variable blank holding force curve to door inner parts could effectively reduce the possibility of fracture and wrinkling.

A Fluid Analysis to develop the Damper for Tsunami Prevention in Nuclear Power Plant (원자력 발전소에서 쓰나미 방지용 댐퍼 개발을 위한 유동해석)

  • Chin, Do-Hun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.24 no.1
    • /
    • pp.53-59
    • /
    • 2021
  • The purpose of this study is to develop a damper that protects against the dangers of tidal waves since there's no function to block the inflow of large amounts of water into the inside When natural disasters such as tidal waves occur. Therefore, it intended to derive the design data by simulating through flow analysis in order to predict the pressure that a damper configured to open and close manually or automatically receives. It examined the preceding researches first and conducted the flow analysis, to predict the force of the damper installed on the bottom of the building's outside to prevent the inflow of seawater into the inside when natural disaster occurring. As a result, it showed that, in the event of a tsunami, it moved about 170m and the time impacting the damper occurred within about eight seconds, and, at the moment, the damper door was pressured about 17bar. Also, it could identify that the load was approximately 900kN and the force by the fluid was applied to the damper door.

EDR platform construction using ELK Stack and Sysmon (ELK Stack과 Sysmon을 이용한 EDR 플랫폼 연구)

  • Shin, Hyun-chang;Kong, Seung-Jun;Oh, Myung-ho;Lee, Dong-hwi
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.10a
    • /
    • pp.333-336
    • /
    • 2022
  • With the development of IT technology, cybercrime is becoming sophisticated and intelligent. In particular, in the case of BackDoor, which is used in the APT attack (intelligent continuous attack), it is very important to detect malicious behavior and respond to infringement because it is often unaware that it has been damaged by an attacker. This paper aims to build an EDR platform that can monitor, analyze, and respond to malicious behavior in real time by collecting, storing, analyzing, and visualizing logs in an endpoint environment in real time using open source-based analysis solutions ELK Stack and Sysmon.

  • PDF

The Efficiency and Improvement of the Highway Wild-Life Fences for Decrease of Mammals Road-kill - In Case of Manjong~Hongchun Section on Jungang Highway - (포유류 로드킬 저감을 위한 고속도로 유도울타리 효율성 및 개선방안 연구 - 중앙고속도로 만종~홍천 구간을 사례로 -)

  • Song, Jeong-Seok;Lee, Kyong-Jae;Ki, Kyong-Seok;Jun, Ik-Yo
    • Korean Journal of Environment and Ecology
    • /
    • v.25 no.5
    • /
    • pp.649-657
    • /
    • 2011
  • This study had targeted the Manjong Junction~Hongchun interchange section of Jungang highway in order to analyze the efficiency and improvement of the highway wild-life fences. Being analyzed wild-life fence as an effective facility for the prevention of road-kill, it had founded that the wild animals did not jump over even the two layer guardrail, concrete barrier and noise barrier, fence for rock fall. For the section with high road-kill decrease effect after installing the wild-life fence, the effect was higher at wild-life fence with the height of 1.0m where the door had not been installed and the well connected points of road facility than the area with fence height of 1.5m. The road-kill decrease effect was also high at the well managed areas even if the door has not been installed. Also, road-kill had occurred by concentrating around the end of wild-life fence after installing the fence, Moreover road-kill had also occurred around the cutting section. The door of wild-life fence had higher amount of road-kill occurrence as the installation interval was closer. it was analyzed that the door management has a lot of effect on road-kill decrease. The fence for rock fall, two layer guardrail and concrete barrier having the effect of wild-life fence installed on the road would have to be installed by connecting with wild-life fences through proper facility improvement. Although the door should not be installed if possible, it should be installed as automatic door or gravity door to prevent the door from leaving the door open. An escape route has to be formed for the prompt escape away from the road for the animals entered through the ending section of the fence. The eco-corridor has to be made by restoring the soil layer of dual purpose eco-corridor forming a planting area. Also, the dead body after the accident has to be disposed to the outer section of the road immediately in order to prevent the secondary road-kill by the predator from the road-kill. The fence has to be installed as 500m or longer in both ways, in other words 1,000m or longer, from the targeted spot of minimum accident prevention while connecting up to the bridge or box culvert, etc that are next road facilities if possible to guide wild animals safely to the eco-corridor.

A Study on Indoor Radon Concentrations in Urban Area (도시 일부지역에서의 실내 라돈농도에 관한 연구)

  • 김순애;백남원
    • Journal of Environmental Health Sciences
    • /
    • v.28 no.2
    • /
    • pp.89-98
    • /
    • 2002
  • This study was taken in general hospital, hotel, shopping center, underground cafe, school, house, for the purpose of investigating the distribution of indoor radon concentration in urban area, by E-PERM which approved U.S. EPA, between August and November 1999. There are two sampling Places were exceed 148 ㏃/㎥(4 pCi/L; U.S EPA remedial level), difference mean is 24.0㏃/㎥ when compared with underground vs. aboveground indoor radon concentration in the same building and ratio is 1.6, so underground area is higher than aboveground (p<0.05). Influencing factors were examined. They related to the location of sampler(detector) open or near the door is lower radon concentration than inside portion, which explains probably open area has better ventilated air and dilutes indoor radon concentration. Temperature has a negative relationship (p<0.05) with indoor radon concentration and relative humidity has a positive (p<0.05) Simultaneously to investigate water radon concentration, collected piped-water and the results were very low, which is the same in piped-water concentration other countries. In conclusion, underground indoor radon concentration is higher than aboveground. Concentration was related to sampling spot, open portion is lower than inside. Higher the temperature, lower the indoor radon concentrations. On the other hand higher the relative humidity, higher the indoor radon concentrations. Indoor radon concentration is influenced by sampling point, temperature, relative humidity.