• Title/Summary/Keyword: One-wire

Search Result 863, Processing Time 0.027 seconds

Charateristics analysis of the joining of YBCO 2G HTS wire (YBCO 2G 선재간 접합 특성 연구)

  • Chang, Ki-Sung;Park, Dong-Keun;Yang, Seong-Eun;Ahn, Min-Cheol;Jo, Dae-Ho;Kim, Hyoun-Kyu;Lee, Hai-Gun;Ko, Tae-Kuk
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.741-742
    • /
    • 2006
  • This paper deals with an efficient superconducting joint method between 2G high superconducting(HTS) wire, YBCO coated conductor(CC). Recently CC is one of the most promising superconducting wire due to high n-value and critical current independency from external magnetic field. It is expected to be used many superconducting application such as fault current limiter, persistent current system and cable etc. In most HTS applications, superconducting magnet is used, and it is necessary to joint between superconducting wire to fabricate superconducting magnet system. A CC tape used in this research consists of copper stabilizer, silver layer, YBCO layer, buffer and substrate. Direct joint using soldering method was inefficient due to resistance of copper, then copper lamination is removed by chemical etching method to reduce resistance between CC tapes. Jointed tapes were fabricated and tested. Transport current through jointed area and induced voltage were measured to characterize the I-V curve. Resistance between CC wire using chemical etching was compared with resistance of direct jointed tapes using soldering method in this paper.

  • PDF

A Study on Magnetic Field Reduction Design Technique around 345 kV Transmission Line with 2-wire Set Passive Loop (2선식 수동루프를 이용한 345[kV] 송전선 주변의 자계저감 설계기법 연구)

  • Kim, Eung Sik
    • Journal of the Korean Society of Safety
    • /
    • v.36 no.5
    • /
    • pp.10-17
    • /
    • 2021
  • The controversy over the risk of the human body being affected by electromagnetic fields emitted from 60 Hz power lines continues without end. There are currently no new studies or research progress being made in this direction that is notable, and the number of civil complaints is gradually increasing. The problem is that each study produces different results, among which the effect of exposure to magnetic fields on childhood leukemia is a major one. In Korea, an electrician who was maintaining a 22.9 kV power line died of leukemia, which has recently been recognized as an occupational disease. Methods to reduce magnetic fields from power lines include shielding with wire loops, incorporating split phases and compaction techniques, installing underground power lines, converting to high-voltage direct current (HVDC), and increasing the ground clearance of transmission towers. Depending on whether a separate power supply is needed or not, there are two types of wire loops: passive loop and active loop. Magnetic field reduction is currently done through underground power lines; however, the disadvantage of this process is high construction costs. Installing passive loops, with relatively low construction costs, leads to lower magnetic field reduction rates than installing underground cables and a weakness to not solving the landscape problem. This methodological study aims at designing methods and reducing the effects of 2-wire set loops-the simplest and most practical. Since the method proposed in this study has been designed after analyzing the distribution of complex electromagnetic fields near the expected loop installation location, a practical design can be implemented without the need for any difficult optimization programming.

Computed Tomography-guided Localization with a Hook-wire Followed by Video-assisted Thoracic Surgery for Small Intrapulmonary and Ground Glass Opacity Lesions (폐실질 내에 위치한 소결질 및 간유리 병변에서 흉부컴퓨터단층촬영 유도하에 Hook Wire를 이용한 위치 선정 후 시행한 흉강경 폐절제술의 유용성)

  • Kang, Pil-Je;Kim, Yong-Hee;Park, Seung-Il;Kim, Dong-Kwan;Song, Jae-Woo;Do, Kyoung-Hyun
    • Journal of Chest Surgery
    • /
    • v.42 no.5
    • /
    • pp.624-629
    • /
    • 2009
  • Background: Making the histologic diagnosis of small pulmonary nodules and ground glass opacity (GGO) lesions is difficult. CT-guided percutaneous needle biopsies often fail to provide enough specimen for making the diagnosis. Video-assisted thoracoscopic surgery (VATS) can be inefficient for treating non-palpable lesions. Preoperative localization of small intrapulmonary lesions provides a more obvious target to facilitate performing intraoperative. resection. We evaluated the efficacy of CT-guided localization with using a hook wire and this was followed by VATS for making the histologic diagnosis of small intrapulmonary nodules and GGO lesions. Material and Method: Eighteen patients (13 males) were included in this study from August 2005 to March 2008. 18 intrapulmonary lesions underwent preoperative localization by using a CT-guided a hook wire system prior to performing VATS resection for intrapulmonary lesions and GGO lesions. The clinical data such as the accuracy of localization, the rate of conversion-to-thoracotomy, the operation time, the postoperative complications and the histology of the pulmonary lesion were retrospectively collected. Result: Eighteen VATS resections were performed in 18 patients. Preoperative CT-guided localization with a hook-wire was successful in all the patients. Dislodgement of a hook wire was observed in one case. There was no conversion to thoracotomy, The median diameter of lesions was 8 mm (range: $3{\sim}15\;mm$). The median depth of the lesions from the pleural surfaces was 5.5 mm (range: $1{\sim}30\;mm$). The median interval between preoperative CT-guided with a hook-wire and VATS was 34.5 min (range: ($10{\sim}226$ min). The median operative time was 43.5.min (range: $26{\sim}83$ min). In two patients, clinically insignificant pneumothorax developed after CT-guided localization with a hook-wire and there were no other complications. Histological examinations confirmed 8 primary lung cancers, 3 cases of metastases, 3 cases of inflammation, 2 intrapulmonary lymph nodes and 2 other benign lesions. Conclusion: CT-guided localization with a hook-wire followed by VATS for treating small intrapulmonary nodules and GGO lesions provided a low conversion thoracotomy rate, a short operation time and few localization-related or postoperative complications. This procedure was efficient to confirm intrapulmonary lesions and GGO lesions.

The fracture resistance of heat pressed ceramics with wire reinforcement (금속선 강화에 따른 열 가압 도재의 파절저항)

  • Jo, Deuk-Won;Dong, Jin-Keun;Oh, Sang-Chun;Kim, Yu-Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.191-198
    • /
    • 2009
  • Statement of problem: Ceramics have been important materials for the restoration of teeth. The demands of patients for tooth-colored restorations and the availability of various dental ceramics has driven the increased use of new types of dental ceramic materials. Improved physical properties of theses materials have expanded its use even in posterior crowns and fixed partial dentures. However, ceramic still has limitation such as low loading capability. This is critical for long-span bridge, because bridge is more subject to tensile force. Purpose: The wire reinforced ceramic was designed to increase the fracture resistance of ceramic restoration. The purpose of this study was to evaluate the fracture resistance of wire reinforced ceramic. Material and methods: Heat pressed ceramic(ingot No.200 : IPS Empress 2, Ivoclar Vivadent, Liechtenstein) and Ni-Cr wire(Alfa Aesar, Johnson Matthey Company, USA) of 0.41 mm diameter were used in this study. Five groups of twelve uniform sized ceramic specimens(width 4 mm, thickness 2 mm, length 15 mm) were fabricated. Each group had different wire arrangement. Wireless ceramic was used as control group. The experimental groups were divided according to wire number and position. One, two and three strands of wires were positioned on the longitudinal axis of specimen. In another experimental group, three strands of wires positioned on the longitudinal axis and five strands of wires positioned on the transverse axis. Three-point bending test was done with universal testing machine(Z020, Zwick, Germany) to compare the flexural modulus, flexural strength, strain at fracture and fracture toughness of each group. Fractured ceramic specimens were cross-sectioned with caborundum disc and grinded with sandpaper to observe interface between ceramic and Ni-Cr wire. The interface between ceramic and Ni-Cr wire was analyzed with scanning electron microscope(JSM-6360, JEOL, Japan) under platinum coating. Results: The results obtained were as follows: 1. The average and standard deviation in flexural modulus, flexural strength and fracture toughness showed no statistical differences between control and experimental groups. However, strain was significantly increased in wire inserted ceramics(P<.001). 2. Control group showed wedge fracture aspects across specimen, while experimental groups showed cracks across specimen. 3. Scanning electron microscopic image of cross-sectioned and longitudinally-sectioned specimens showed no gap at the interface between ceramic and Ni-Cr wire. Conclusion: The results of this study showed that wire inserted ceramics have a high strain characteristic. However, wire inserted ceramics was not enough to use at posterior area of mouth in relation to flexural modulus and flexural strength. Therefore, we need further studies.

An Experimental Study on the Flexural Behavior of One-Way Concrete Slabs Using the Restorative Mortar and Crimped Wire Mesh (크림프 철망 및 단면복구 보수 모르타르를 사용한 일방향 슬래브의 휨 거동에 관한 실험적 연구)

  • Lee, Mun-Hwan;Song, Tae-Hyeob
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.5
    • /
    • pp.569-575
    • /
    • 2007
  • The repair of concrete surfaces does not normally take into account structural tolerance for longer service lift and better capabilities of concrete structures. In particular, the repair of surface spelling completes as mortar is applied, which does not display additional structural performances. The use of crimped wire mesh for better construction and fracture resistance, however, expects to have some reinforcement effects. Particularly, it is also expected that the repair of bottom part in structures built between bridges like irrigation structures results in the increase of flexural resistance. Therefore, this study is intended to perform the repair using crimp wire mesh and examine strength depending on the repair section and depth. For this, a slab with 150 mm in depth, 3,000 mm in length and 600 mm in width and total 8 objects to experiment such as upper part, upper whole, bottom part, bottom whole and crimp wire mesh reinforced are manufactured to perform flexural performance. The results of the analysis show that yield strength and failure load increase as the depth of repair materials in the experiment reinforced with crimp wire mesh get bigger. In the same condition, repair of bottom part is able to increase internal force of bending force. Besides, the results show that partial repair of structures under bending force cannot produce flexural performance. Consequently, the repair method with crimp wire mesh results in the increase of flexural resistance.

Optimization of wiring process in semiconductor with 6sigma & QFD (6시그마와 QFD를 활용한 반도체용 wire공법 최적화 연구)

  • Kim, Chang-Hee;Kim, Kwang-Soo
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.7 no.3
    • /
    • pp.17-25
    • /
    • 2012
  • Wire bonding process in making semiconductor needs the most precise control and Critical To Quality(CTQ). Thus, it is regarded to be the most essential step in packaging process. In this process, pure gold wire is used to connect the chip and PCB(substrate or lead frame). However, the price of gold has been skyrocketing continuously for a long period of time and is expected to further increase in the near future. This phenomenon situates us in an unfavorable condition amidst the competitive environment. To avoid this situation, many semiconductor material making companies developed new types of wires: Au.Ag wire is one material followed by many others. This study is aimed to optimize the parameter in wire bonding with the use of 6sigma and QFD(Quality Function Deployment). 6sigma process is a good means to not only solve the problem, but to increase productivity. In order to find the key factor, we focused on VOB(Voice of Business) and VOC(Voice of Customer). The main factors from VOB, VOC are called CTQ. However, there were times when these main factors were far from offering us the correct answer, thus making the situation more difficult to handle. This study shows that QFD aids in deciding which of the accurate factors to undertake. Normally QFD is used in designing and developing products. 6sigma process is held more effective when it used with QFD.

  • PDF

A Comparative Study of Range of Motion With or Without Distal Interphalangeal Joint Fixation in Replantation of the Amputated Fingertips (수지 첨부 절단창의 재접합술 시 원위지 관절 고정과 운동 범위의 관계)

  • Han, Seung-Kyu;Roh, Si-Young;Kim, Jin-Soo;Lee, Dong-Chul;Ki, Sae-Hwi;Yang, Jae-Won
    • Archives of Reconstructive Microsurgery
    • /
    • v.20 no.1
    • /
    • pp.18-25
    • /
    • 2011
  • Purpose: In the process of replantation of the amputated fingertips, the primary concern was given to survival of the amputees, while the functional aspect of digits after the surgery has been easily neglected. Although an internal fixation with a K-wire is often a part of replantation of the amputated fingertips, little consideration had been given to the study of relationship between distal interphalangeal joint fixation and post operative range of motion. A comparative study in relation to post operative range of motion was done on two different groups, one group with K-wire insertion and the other group without a K-wire insertion at the distal interphalangeal joint. Materials and Methods: The study was done on the cases of a single digit amputation conducted at our institute (the age in the range of 10 to 60) in about four-year of time span from March of 2005 to March of 2009. The cases with a thumb replantation, osteomyelitis or articular surface injury have been excluded from this study. The cases of both head and shaft fracture, except the insertion site of tendon, of distal phalanx of internal fixation with a single K-wire were reviewed for this study. A group of 24 cases without distal interphalangeal joint fixation in comparison to a group of 22 cases with distal interphalangeal joint fixation was reviewed to assess the postoperative range of motion at distal interphalangeal joint on the 6th week after the surgery. And, on the 30th month after the surgery, a group of 10 cases without distal interphalangeal joint fixation in comparison to a group of 10 cases with joint fixation was reviewed. A K-wire was removed in about 5 weeks after the fracture was reunited under the radiographic image, immediately followed by a physical therapy. Result: The active range of motion for a group without interphalangeal joint fixation was measured $49.0^{\circ}$ on average, while $28.6^{\circ}$ was measured for a group with interphalengeal fixation on the 6th week after the surgery. On the 30th month after the surgery, the active range of motion was measured $52.0^{\circ}$ and $55.0^{\circ}$ on average for a group without and with interphalangeal fixation respectively. Conclusion: In the process of replantation of the amputated fingertips, short-term(on the 6th week) improvement of postoperative active motion of range can be expected in the cases without distal interphalangeal fixation in comparison to the cases of interphalangeal joint fixation with a K-wire. However, there seems to be no difference on motion of range in a long-term (on the 30th month) follow up period.

  • PDF

Wire Recognition on the Chip Photo based on Histogram (칩 사진 상의 와이어 인식 방법)

  • Jhang, Kyoungson
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.5
    • /
    • pp.111-120
    • /
    • 2016
  • Wire recognition is one of the important tasks in chip reverse engineering since connectivity comes from wires. Recognized wires are used to recover logical or functional representation of the corresponding circuit. Though manual recognition provides accurate results, it becomes impossible, as the number of wires is more than hundreds of thousands. Wires on a chip usually have specific intensity or color characteristics since they are made of specific materials. This paper proposes two stage wire recognition scheme; image binarization and then the process of determining whether regions in binary image are wires or not. We employ existing techniques for two processes. Since the second process requires the characteristics of wires, the users needs to select the typical wire region in the given image. The histogram characteristic of the selected region is used in calculating histogram similarity between the typical wire region and the other regions. The first experiment is to select the most appropriate binarization scheme for the second process. The second experiment on the second process compares three proposed methods employing histogram similarity of grayscale or HSV color since there have not been proposed any wire recognition method comparable by experiment. The best method shows more than 98% of true positive rate for 25 test examples.

Effect of Shear Deformation During Drawing on Inhomogeneous Microstructures and Textures in High Purity Copper Wires After Annealing (고순도 구리 선재의 어닐링 후 불균질 미세조직과 집합조직에 미치는 신선 시 전단 변형의 영향)

  • Park, Hyun;Kim, Sang-Hyeok;Kim, Se-Jong;Lee, Hyo-Jong
    • Korean Journal of Metals and Materials
    • /
    • v.56 no.12
    • /
    • pp.861-869
    • /
    • 2018
  • To determine the origin of the inhomogeneous microstructure and texture observed in drawn and annealed high purity copper wires, two kinds of drawing process conditions and their influence was investigated. The regular condition, based on a symmetric die, and a condition designed intentionally to produce an inhomogeneous shear deformation using an asymmetric die were employed. The difference in intensity of <111>-<100> distributed texture between the two wires confirmed that the wire drawn under the asymmetric die condition experienced a higher amount of shear deformation. The extensive shear strain in the wire drawn under the asymmetric die condition gave rise to inhomogeneous primary and secondary recrystallization behavior. After annealing at $200^{\circ}C$, grains with <100> texture, which were larger than the surrounding recrystallized grains, were extensively present on one half circle of the wire drawn under the asymmetric die condition, while larger grains with <100> were sparsely observed around the middle region of the wire drawn under the regular condition. Interestingly, the area where the larger grains with <100> texture existed was identical to the area where the high shear strain occurred during drawing in both wires. During annealing at $400^{\circ}C$, grains with <112> texture started to grow abnormally at the center of both wires as a result of secondary recrystallization. After annealing at $900^{\circ}C$ grains with <112> due to secondary recrystallization occupied the entire region of the wire drawn under the regular condition. On the other hand, in the wire drawn under the asymmetric die condition and then annealed at $900^{\circ}C$, the <100> oriented grains as a result of the normal grain growth of the larger <100> grains which were observed after annealing at $200^{\circ}C$, coexisted with the abnormally grown <112> grains. These results indicate that dynamic recrystallization induced by the shear strain during drawing plays an important role in the inhomogeneity of the microstructure and texture of wires after annealing.

The Surgical Treatment of Type V Acute Acromioclavicular Joint Dislocation Using Suture Anchor and Kirschner Wire (봉합 나사못과 Kirschner 강선을 이용한 제 5형 급성 견봉 쇄골 관절 탈구의 수술적 치료)

  • Jung, Gu-Hee;Cho, Chyul-Hyun;Jang, Su-Jin;Jang, Jae-Ho;Kim, Jae-Do
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.2
    • /
    • pp.217-222
    • /
    • 2010
  • Purpose: We wanted to evaluate the clinical outcomes after operative treatment using two suture anchors and Kirschner wire for treating acute Rockwood type V acromioclavicular joint dislocation Materials and Methods: Between May 2006 and May 2009, 10 patients underwent surgical treatment for acute Rockwood type V acromioclavicular joint dislocation using two suture anchors and Kirschner wire and they were followed for a mean of 12.0 (range: 7-31) months. We analyzed the functional results by the Korean shoulder score, the Constant-Murley score and the reduction state of the acromioclavicular joint at the last follow-up. Results: All the cases achieved a satisfactory outcome. The mean Korean shoulder score was 89.9 (range: 81-100) points and the mean Constant-Murley score was 87.8 (range: 82-93) points. According to the radiologic findings, 8 patients achieved anatomical reduction of the acromioclavicular joint: there was a slight loss of reduction in one patient and a partial loss of reduction in one patient. None of the patients had deep infection or re-dislocation. Conclusion: The operative treatment using two suture anchors and Kirschner wire may be used for acute Rockwood type V acromioclavicular joint dislocation, and it has an advantage in that it can prevent chondral injury of the joint.