Browse > Article
http://dx.doi.org/10.4334/JKCI.2007.19.5.569

An Experimental Study on the Flexural Behavior of One-Way Concrete Slabs Using the Restorative Mortar and Crimped Wire Mesh  

Lee, Mun-Hwan (Building & Urban Research Division, KICT)
Song, Tae-Hyeob (Building & Urban Research Division, KICT)
Publication Information
Journal of the Korea Concrete Institute / v.19, no.5, 2007 , pp. 569-575 More about this Journal
Abstract
The repair of concrete surfaces does not normally take into account structural tolerance for longer service lift and better capabilities of concrete structures. In particular, the repair of surface spelling completes as mortar is applied, which does not display additional structural performances. The use of crimped wire mesh for better construction and fracture resistance, however, expects to have some reinforcement effects. Particularly, it is also expected that the repair of bottom part in structures built between bridges like irrigation structures results in the increase of flexural resistance. Therefore, this study is intended to perform the repair using crimp wire mesh and examine strength depending on the repair section and depth. For this, a slab with 150 mm in depth, 3,000 mm in length and 600 mm in width and total 8 objects to experiment such as upper part, upper whole, bottom part, bottom whole and crimp wire mesh reinforced are manufactured to perform flexural performance. The results of the analysis show that yield strength and failure load increase as the depth of repair materials in the experiment reinforced with crimp wire mesh get bigger. In the same condition, repair of bottom part is able to increase internal force of bending force. Besides, the results show that partial repair of structures under bending force cannot produce flexural performance. Consequently, the repair method with crimp wire mesh results in the increase of flexural resistance.
Keywords
flexural behavior; crimped wire mesh; repair; reinforcement; polymer mortar;
Citations & Related Records
연도 인용수 순위
  • Reference
1 엠앤에스인더스트리 주식회사, '이형 와이어로프 PS강연성과 알루미나 폴리사카라이드 폴리머모르타르를 이용한 콘크리트 구조물의 보수.보강 공법 (SRAP공법)', 신기술지정신청서, 2003. 5, pp.257-283
2 한국건설기술연구원, 'RC 구조물의 철근부식 방지 및 보수공법 시스템화 연구', 2000. 12, pp.49-57
3 Beeby, A. W., Concrete in the Oceans, Cracking and Corrosion, Cement and Concrete Association, 1978, pp.1-77
4 김무한, 김규용, 김재환, 조봉석, 김영선, '염해 및 중성화의 복합열화 작용에 의한 표면피복 종류별 철근콘크리트의 부식특성', 대한건축학회논문집 구조계, 21권 9호(통권203호), 2005, pp.97-104
5 허갑수, 윤영호, 양지수, 김석중, 정헌수, '구조용 용접철망을 사용한 일방향 슬래브의 휨 거동에 관한 실험적 연구', 대한건축학회학술발표대회, 13권 2호, 1993, pp.555-558
6 Allen, R. T. L., et al., The Repair of Concrete Structure, 1993, pp.15-32
7 안상호, '경량패널에 탄소섬유시트가 접착된 복합패널로 보강한 RC 슬래브의 휨 거동에 관한 실험적 연구', 대한건축학회논문집 구조계, 18권 4호 (통권162호), 2002, pp.51-58
8 Ross, C. A., Jerome, D. M., and Hughes, M. L., 'Strengthening of Reinforced Concrete Beams with Externally Bonded Composite Laminates', ACI Structural Journal, Vol.96, No.23, 1999, pp.212-220
9 한국건설기술연구원, 'PSMD 보수공법의 현장 적용성 및 품질 평가 연구', 한국건설기술연구원, 2005. 10, pp.487-495