A Study on the Collision-Avoidance Action of Bottom Trawler under Operation (조업중인 저층 트롤선의 충돌회피 동작에 관한 연구)

  • KIM, Min-Seok;KIM, Jin-Gun;KIM, Jong-Hwa;JEONG, Sun-Beom
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.15 no.1
    • /
    • pp.47-56
    • /
    • 2003
  • Recently with the conclusion of fisheries agreements between Korea and Japan, and between Korea and China, trawlers in korea must operate in smaller fishing ground than before. As a result of this, the possibilities of collisionin increases gradually between trawlers under operation in this area. Authors performed a series of experiments on board to give the information of collision avoiding action to navigators of trawlers. The obtained results are summerized as follows : 1. The greater the rudder angle, the smaller the value of T, but there is no big diffierence in K due to rudder angle. 2. The greatest distance is to be kept by the give way vessel to avoid collision when the crossing course angle is $70^{\circ}{\sim}90^{\circ}$. In this case the safety minimum approaching distance must be more than 5 times of her own length. 3. Risk of collision in crossing is more greater in obtuse situation than in acute one. 4. The navigator of the give way vessel must take an action to avoid collisions outside of the minimum safety approaching distance.

Influence of Design Variables on Flow Characteristics of Poppet Valve using Analysis of Means (평균분석을 이용한 설계변수가 포핏 밸브의 유동특성에 미치는 영향)

  • Jeong, Ja-Young;Choi, Eun-Ho;Kang, Young-Jin;Noh, Yoojeong;Lim, O-Kaung
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.30 no.3
    • /
    • pp.239-248
    • /
    • 2017
  • According to the structure, solenoid valve can be categorized as spool valve or poppet valve. While various research on spool valve which has simple structure and fine susceptibility to contamination has been conducted, poppet valve which has less susceptibility to contamination and advantage in a long time operation still need much research because of its complicated structure. In order to design the poppet valve, various parameters such as the diameter of the poppet, the angle of the poppet, the diameter of the disk, the spring stiffness, the spring preload and flow path structure should be considered. Conventional studies on poppet valve usually take only one design parameters and did not much focused on the effect of the parameters on flow characteristics. In this paper, the change of the flow characteristics according to the design parameters of the poppet valve for 3/2Way solenoid valve is analyzed. The previous studies and the results of initial model analysis was referred for the selection of the design parameters. The effects of design parameters on maximum pressure, minimum pressure, and pressure drop was examined using analysis of means(ANOM).

The circuit design to be power transmission or power distribution using the dual characteristic impedance transmission line (이중 특성 임피던스 전송 선로를 이용한 전력 전송 또는 전력 분배가 가능한 회로 설계)

  • Park, Unghee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.10
    • /
    • pp.2339-2344
    • /
    • 2014
  • of a microstrip transmission line, this transmission line can operate as the microstrip line or the coplanar line according to open or short connection between the ungrounded copper plane and grounded plane on the base plane. Two different type operation of the transmission line means that one transmission line can have two different characteristic impedances. This paper proposes and fabricates the circuit to be operated 2-ports power transmission line or 2-way power divider with the stable input matching characteristic by using this dual-impedance transmission line. The proposed circuit operates 2-ports power transmission line in case of the coplanar line or 2-way power divider line in case of the microstrip line. The fabricated circuit shows $S_{21}$ > -0.2 dB and $S_{11}$ < -15 dB above 700 MHz when the circuit operates 2-ports power transmission line. And, it is $S_{21}$ > -3.8 dB, $S_{11}$ < -10 dB and $S_{21}/S_{31}$ < ${\pm}0.3dB$ above 700 MHz when the circuit operates 2-way power divider.

An Empirical Research on the IoT Basis Gas AMI Platform and Smart Metering Services (IoT 기반 가스 원격검침(AMI) 플랫폼과 서비스의 실증 연구)

  • Lee, Seungwoo;Lee, Sangshin;Song, Min-hwan;Kwon, Youngmin
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.3
    • /
    • pp.1-10
    • /
    • 2020
  • This paper describes the development of a smart advanced metering infrastructure(AMI) architecture and services for using smart metering in gas industry. A general gas AMI system is composed of a smart gas meter, IoT network, the AMI platform, and an operation management system with security functions. The proposed gas AMI platform supports two-way communication between smart metering devices and AMI services and is applied by oneM2M standard to support interoperability between various types of metering devices and heterogeneous IoT networks. To demonstrating AMI system with the proposed platform, we installed about 2,900 smart gas meters in real environments and operated AMI systems for one year. We verified that about 94% of gas meters are normally worked and AMI services are stably operated without error or malfunction.

A Study on the Optimal Width of the Main Span In the 2nd Bridge of lncheon (2) Economic Analysis on Port Operation according to Traffic Schemes in the Main Span (인천항 제2연륙교 적정 주경간 폭 결정에 관한 연구 (2) 주경간의 통항방식에 따른 항만운영의 경제성 분석)

  • Koo Ja-Yun;Kim Seok- Jae;Jang Eun- Kyu
    • Journal of Navigation and Port Research
    • /
    • v.29 no.1 s.97
    • /
    • pp.65-69
    • /
    • 2005
  • A construction project of Incheon 2nd bridge, which is connected between the Incheon Song-Do New Town and the Incheon International Airport in Young-Jong-Do, has been proposed by the private capital in 1999. But the optimal width of the main span has not been decided in spite of the three investigations into the feasibility of ship's safe transit in this planned bridge. In this paper, we study the economic analysis on port operational efficiency according to traffic schemes, one-way or two-way of vessels over 10,000G/T, in the main span of this bridge. In this comparative result, total queueing time due to the one-way in the bridge main span is evaluated 20,362 hours in 2011 and 24,544 hours in 2020. Therefore the demurrage cost and the accumulation cost of freight are evaluated 19.7 billion won in 2011, and 23.3 billion won in 2020, then total accumulated costs during 33 years from 2008 until 2040 are evaluated about 768.9 billion won.

A Study on Revitalization of Rooftop Garden by Assessing the Publicness : a Case of Mullae Roof Garden, Mullae-dong, Seoul (옥상텃밭의 공공성 평가에 따른 이용 활성화 방안 연구)

  • Kwang, Nae-Young
    • Journal of Korean Society of Rural Planning
    • /
    • v.22 no.3
    • /
    • pp.131-142
    • /
    • 2016
  • Urban agriculture, which can be defined as agriculture performed in a city, is suggested as an alternative solution to restore deserted community and expand green land in city area through cultivation activities. In Korea, 'Urban Agriculture Promotion and Support Act' was enforced from May 2012. In addition, in the same year, Seoul Metropolitan Government declared 'the beginning of urban agriculture era,' established municipal ordinance, and increased budget to actively support urban agriculture. As a result, urban agriculture practices have been increasing every year. Yet, the way of developing urban agriculture in a uniform way of expanding green land has led to difficulties of securing proper spaces. Accordingly, 'roof top' spaces have gained attention. This study analyzes rooftop garden, one of the spaces of carrying out urban agriculture, from the publicness perspective. The study selected a case study of a public rooftop garden in Mullae-dong, Yeongdeungpo-gu, investigated present conditions and usage features of the garden, and explored the conditions to be a 'public' roof top garden. Through theoretical analysis, both physical and non-physical indicators were derived for analysis framework; physical aspects- accessibility, locality, openness, comfortness, and non-physical aspects- subjectivity, cooperativeness, and a sense of community. The results of this study are as follows. First, openness and locality scores were the highest, and comfortness scored the lowest, in ensuring the publicness of Mullae roof top garden. Second, non-physical indicators had stronger effect than physical indicators on rooftop garden users' awareness on publicness and building a garden community. In conclusion, in order to vitalize roof top garden, users should be engaged from the very first planning stage of building a garden, opening hours should not be limited, and more importance should be put on users to subjectively manage the operation of rooftop garden than merely creating a physical environment.

Harmonics Assessment for an Electric Railroad Feeding System using Moments Matching Method (모멘트 정합 방법(Moment Matching Method)을 이용한 전기철도 급전시스템의 고조파 평가)

  • Lee, Jun-Kyong;Lee, Seung-Hyuk;Kim, Jin-O
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.1
    • /
    • pp.1-7
    • /
    • 2007
  • Generally, an electric railroad feeding system has many problems due to the different characteristics in contrast with a load of general three-phase AC electric power system. One of them is harmonics problem caused by the switching device existing in the feeding system, and moreover, the time-varying dynamic loads of rail way is inherently another cause to increase this harmonics problem. In Korea power systems, the electric railroad feeding system is directly supplied from the substation of KEPCO. Therefore, if voltages fluctuation or unbalanced voltages are created by the voltage and current distortion or voltage drop during operation, it affects directly the source of supply. The trainloads of electric railway system have non-periodic but iterative harmonic characteristics as operating condition, because the electric characteristic of the electric railroad feeding system is changed by physical conditions of the each trainload. According to the traditional study, the estimation of harmonics has been performed by deterministic way using the steady state data at the specific time. This method is easy to analyze harmonics, but it has limits in some cases which needs an assessment of dynamic load and reliability. Therefore, this paper proposes the probabilistic estimation method, moments matching method(MW) in order to overcome the drawback of deterministic method. In this paper, distributions for each harmonics are convolved to obtain the moments and cumulants of TDD(Total Demand Distortion), and this can be generalized for any number of trains. For the case study, the electric railway system of LAT(Intra Airport Transit) in Incheon International Airport is modeled using PSCAD/EMTDC dynamic simulator. The raw data of harmonics for the moments matching method is acquired from simulation of the LAT model.

A Study on Domestic Distribution Channels of Foreign Clothing Brands and Consumers' Purchase Decision -With focuses on competitiveness of goods and consumer characteristics by distribution channels- (해외의류브랜드의 국내 유통경로와 소비자구매결정에 관한 연구 - 유통경로별 상품경쟁력과 소비자특성을 중심으로 -)

  • Park, Soo-Hong
    • International Commerce and Information Review
    • /
    • v.14 no.2
    • /
    • pp.173-199
    • /
    • 2012
  • The purpose of the study is to test and analyze differences in consumers' satisfaction and influences of competitiveness of goods on consumers' purchase decision by demographic characteristics and by channel distribution. The hypotheses have been tested through T-test and ANOVA with one-way and two-way using SPSS Win Ver. 12.0. The distribution channels are classfied with five ones such as company direct operation shop, agent licensed shop, department store, internet home shopping and outlet goods shop. This study can indirectly suggest a local clothing brand industry countermeasures for raising competitiveness and changing consumer preferences in the open domestic market.

  • PDF

Facility scheduling problem in Grain terminal for reducing demurrage rate (양곡부두의 체선율 감소를 위한 부두 장비 및 사일로 스케줄링 연구)

  • Shin, Jae Young;Park, Jongwon
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2013.06a
    • /
    • pp.60-61
    • /
    • 2013
  • One of the most important indicators for measuring service level and productivity of the port may be a demurrage rate. Currently, in the case of grain terminal of Busan North Port, demurrage rate are recognized at a very high level, in order to improve this, it is tilted more effort operational. In order to reduce the demurrage, there is a way expansion of facility of hardware, such as the replacement of aging equipment, and how manipulative assignment rules of the apparatus of the operation on the software side, such as changing the order of facility allocation. If the financial reasons are out of question, it is possible to expand to reduce the demurrage rate by operational way. Therefore this paper deals with how to operate some of the allocation rules and silo allocation rules of equipment to reduce the work hours with model and how to operate basic equipment and grain terminal of Busan North Port want to be seen by comparative analysis.

  • PDF

A Study on Power Control using PMS (PMS 시스템을 활용한 전력제어에 관한 연구)

  • Kim, Sung-Cheol;Kim, Kyoung-Wook;Woo, Chun-Hee
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.65 no.3
    • /
    • pp.194-198
    • /
    • 2016
  • The electric power industry have recently been building out Smart Grids, a two-way electricity grid that connects power consumers and producers to a network that enables one to respond quickly to any eventuality. The construction of a two-way electricity grid means that the power control process becomes unified, from what used to be separate processes that originate individually from the consumption phase and the production and supply phases. The role of power control that takes place within each section of the power system may be independent. However, this does not mean the independent control sections are operated individually, but are configured to meet a single target and purpose. Each control section possesses enough degree of independency to respond to eventualities that may occur within different stages of the power system, but at the same time, possesses unified system elements for the stability of the entire power system. From this perspective, Smart Grids are widely regarded as the most rational power industry operation plan. A variety of different control and communication systems can be applied for an effective deployment of Smart Grids. Recently, we have seen systems such as PMS(Power Management System) and PAS(Process Automation System) applied in the deployment of Smart Grids, which are developed from the techniques utilized in the industry. The PMS is attracting particular attention for its power operations management ability. In this study, we propose plans for improvement in the rational development of power system controls through case studies of live PMS operations.