• Title/Summary/Keyword: One-step

Search Result 4,652, Processing Time 0.042 seconds

One-Step-Ahead Control of Waveform and Detection Threshold for Optimal Target Tracking in Clutter (클러터 환경에서 최적의 표적 추적을 위한 파형 파라미터와 검출문턱 값의 One-Step-Ahead 제어)

  • Shin Han-Seop;Hong Sun-Mog
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.43 no.1 s.307
    • /
    • pp.31-38
    • /
    • 2006
  • In this paper, we consider one-step-ahead control of waveform parameters (pulse amplitudes and lengths, and FM sweep rate) as well as detection thresholds for optimal range and range-rate tracking in clutter. The optimal control of the combined parameter set minimizes a tracking performance index under a set of parameter constraints. The performance index includes the probability of track loss and a function of estimation error covariances. The track loss probability and the error covariance are predicted using a hybrid conditional average algorithm The effect of the false alarms and clutter interference is taken into account in the prediction. Tracking performance of the one-step-ahead control is presented for several examples and compared with a control strategy heuristically derived from a finite horizon optimization.

Blind Equalization with Arbitrary Decision Delay using One-Step Forward Prediction Error Filters (One-step 순방향 추정 오차 필터를 이용한 임의의 결정지연을 갖는 블라인드 등화)

  • Ahn, Kyung-seung;Baik, Heung-ki
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.2C
    • /
    • pp.181-192
    • /
    • 2003
  • Blind equalization of communication channel is important because it does not need training signal, nor does it require a priori channel information. So, we can increase the bandwidth efficiency. The linear prediction error method is perhaps the most attractive in practice due to the insensitive to blind channel equalizer length mismatch as well as for its simple adaptive implementation. Unfortunately, the previous one-step prediction error method is known to be limited in arbitrary decision delay. In this paper, we propose method for fractionally spaced blind equalizer with arbitrary decision delay using one-step forward prediction error filter from second-order statistics of the received signals for SIMO channel. Our algorithm utilizes the forward prediction error as training signal and computes the best decision delay from all possible decision delay. Simulation results are presented to demonstrate the performance of our proposed algorithm.

The effect of screw tightening techniques on the detorque value in internal connection implant superstructure (내부연결 임플란트 상부구조물에서 나사조임술식이 풀림토크값에 미치는 영향)

  • Choi, Jung-Han
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.4
    • /
    • pp.243-250
    • /
    • 2010
  • Purpose: This study evaluated the effect of different screw tightening sequences and methods on detorque values in a well-fitting implant superstructure. Materials and methods: A fully edentulous mandibular master model and a metal framework directly connected to four parallel implants (Astra Tech) with a passive fit to each other were fabricated. Six stone casts were made with a splinted impression technique to represent a 'well-fitting' situation with the metal framework. Detorque values were measured twice after screw tightening using 20 Ncm. Detorque values and minimum detorque values for three screw tightening sequences (1-2-3-4, 2-4-3-1, and 2-3-1-4) and for two tightening methods (two-step and one-step) were analyzed using multi-way analysis of variance and two-way analysis of variance, respectively, at a .05 level of significance. Results: The mean detorque values for screw tightening sequences ranged from 12.8 Ncm (2-4-3-1) to 13.1 Ncm (2-3-1-4), and for screw tightening methods were 13.1 Ncm (two-step) and 11.8 Ncm (one-step). The mean of mimimum detorque values for screw tightening sequences were 11.1 Ncm (1-2-3-4) and 11.2 Ncm (2-4-3-1 and 2-3-1-4), and for screw tightening methods were 11.2 Ncm (two-step) and 9.9 Ncm (one-step). No statistically significant differences among three screw tightening sequences were found for detorque values and for mimimum detorque values. But, statistically significant differences between two screw tightening methods were found for two values. Two-step screw tightening method showed higher detorque value (P = .0003) and higher minimum detorque value (P = .0035) than one-step method. Conclusion: Within the limitations of this study, the screw tightening sequence was not a critical factor for the detorque values in a well-fitting implant superstructure by the splinted impression technique. But, two-step screw tightening method showed greater detorque values than one-step method.

Three Dimensional Multi-step Inverse Analysis for Optimum Blank Design in Sheet Metal Forming (박판금속성형의 최적 블랭크 설계를 위한 삼차원 다단계 역해석)

  • Lee, Choong-Ho;Huh, Hoon
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1997.03a
    • /
    • pp.179-182
    • /
    • 1997
  • One-step inverse methods based on deformation theory causes some amount of error. The amount of error is generally increased as the deformation path is more complex. As a remedy, a new three dimensional multi-step inverse method is introduced for optimum design of blank shapes and strain distributions from desired final shapes. The approach extends a one-step inverse method to a multi-step inverse method in order to reduce the amount of error. The algorithm developed is applied to square cup drawing to confirm its validity by demonstrating reasonably accurate numerical results.

  • PDF

A Study on the Comparison of One Step Method and Two Step Method to Improve Reporting of CA 19-9 Results (CA 19-9 결과보고 개선을 위한 One step 방식과 Two step 방식의 비교에 관한 연구)

  • Jae-Seok An;Ji-Na Kim;Kwang-Seo Park;Eun-Bit Joo;Sang-Hyuk Yoon;Yoon-Cheol Kim
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.28 no.1
    • /
    • pp.81-87
    • /
    • 2024
  • Purpose: CA 19-9 is the most widely used tumor marker for the diagnosis of digestive system tumor, especially pancreatic and biliary tract cancer. This study was conducted to improve the result value near reference range by comparing the reagents of CA 19-9 one step method and two step method. In addition, it was intended to establish a standard for selecting reagents. Material and Methods: 120 patients who visited the National Cancer Center in 2023 were selected as subjects for this study. The reagents used in the study were CA 19-9 IRMA kits (Shinjin, Korea) and three types of reagents were compared. Two step method reagent that is currently being used (A), one step method reagent (B) and two step method reagent improved by request (C) were compared and regression analysis was performed on their data. And we also performed recovery test, linearity test and hook effect test for each reagent. Result: There were 46 cases of reagent B in which the concentration value was lower than the result measured in reagent A that was previously used, and 77 cases of reagent C. As a result of regression analysis of reagents A, B, and C, the coefficients of determination of reagents A and B, reagents A and C, and reagents B and C were 0.653, 0.577, and 0.875. In the recovery rate test and the linearity test, the results of all reagents were good, and in the hook effect test, reagent B showed a hook effect at a low value. Conclusion: The improved reagent C appears to have been improved based on the concentration value of reagent B, which the manufacturer judged to be more stable at low concentrations. The hook effect in reagent B can be a fatal reason for disqualification when selecting reagents in general patient samples which high-concentration samples appear frequently. The first improved reagent C will be able to be used once it is confirmed that it has more stability for various concentration values.

A One-Step System for Convenient and Flexible Assembly of Transcription Activator-Like Effector Nucleases (TALENs)

  • Zhao, Jinlong;Sun, Wenye;Liang, Jing;Jiang, Jing;Wu, Zhao
    • Molecules and Cells
    • /
    • v.39 no.9
    • /
    • pp.687-691
    • /
    • 2016
  • Transcription activator-like effector nucleases (TALENs) are powerful tools for targeted genome editing in diverse cell types and organisms. However, the highly identical TALE repeat sequences make it challenging to assemble TALEs using conventional cloning approaches, and multiple repeats in one plasmid are easily catalyzed for homologous recombination in bacteria. Although the methods for TALE assembly are constantly improving, these methods are not convenient because of laborious assembly steps or large module libraries, limiting their broad utility. To overcome the barrier of multiple assembly steps, we report a one-step system for the convenient and flexible assembly of a 180 TALE module library. This study is the first demonstration to ligate 9 mono-/dimer modules and one circular TALEN backbone vector in a one step process, generating 9.5 to 18.5 repeat sequences with an overall assembly rate higher than 50%. This system makes TALEN assembly much simpler than the conventional cloning of two DNA fragments because this strategy combines digestion and ligation into one step using circular vectors and different modules to avoid gel extraction. Therefore, this system provides a convenient tool for the application of TALEN-mediated genome editing in scientific studies and clinical trials.

Damage Detection of Railroad Tracks Using Piezoelectric Sensors (압전센서를 이용하는 철로에서의 손상 검색 기술)

  • Yun Chung-Bang;Park Seung-Hee;Inman Daniel J.
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2006.04a
    • /
    • pp.240-247
    • /
    • 2006
  • Piezoelectric sensor-based health monitoring technique using a two-step support vector machine (SYM) classifier is discussed for damage identification of a railroad track. An active sensing system composed of two PZT patches was investigated in conjunction with both impedance and guided wave propagation methods to detect two kinds of damage of the railroad track (one is a hole damage of 0.5cm in diameter at web section and the other is a transverse cut damage of 7.5cm in length and 0.5cm in depth at head section). Two damage-sensitive features were extracted one by one from each method; a) feature I: root mean square deviations (RMSD) of impedance signatures and b) feature II: wavelet coefficients for $A_0$ mode of guided waves. By defining damage indices from those damage-sensitive features, a two-dimensional damage feature (2-D DF) space was made. In order to minimize a false-positive indication of the current active sensing system, a two-step SYM classifier was applied to the 2-D DF space. As a result, optimal separable hyper-planes were successfully established by the two-step SYM classifier: Damage detection was accomplished by the first step-SYM, and damage classification was also carried out by the second step-SYM. Finally, the applicability of the proposed two-step SYM classifier has been verified by thirty test patterns.

  • PDF

Speedy Two-Step Thermal Evaporation Process for Gold Electrode in a Perovskite Solar Cell

  • Kim, Kwangbae;Park, Taeyeul;Song, Ohsung
    • Korean Journal of Materials Research
    • /
    • v.28 no.4
    • /
    • pp.235-240
    • /
    • 2018
  • We propose a speedy two-step deposit process to form an Au electrode on hole transport layer(HTL) without any damage using a general thermal evaporator in a perovskite solar cell(PSC). An Au electrode with a thickness of 70 nm was prepared with one-step and two-step processes using a general thermal evaporator with a 30 cm source-substrate distance and $6.0{\times}10^{-6}$ torr vacuum. The one-step process deposits the Au film with the desirable thickness through a source power of 60 and 100 W at a time. The two-step process deposits a 7 nm-thick buffer layer with source power of 60, 70, and 80 W, and then deposits the remaining film thickness at higher source power of 80, 90, and 100 W. The photovoltaic properties and microstructure of these PSC devices with a glass/FTO/$TiO_2$/perovskite/HTL/Au electrode were measured by a solar simulator and field emission scanning electron microscope. The one-step process showed a low depo-temperature of $88.5^{\circ}C$ with a long deposition time of 90 minutes at 60 W. It showed a high depo-temperature of $135.4^{\circ}C$ with a short deposition time of 8 minutes at 100 W. All the samples showed an ECE lower than 2.8 % due to damage on the HTL. The two-step process offered an ECE higher than 6.25 % without HTL damage through a deposition temperature lower than $88^{\circ}C$ and a short deposition time within 20 minutes in general. Therefore, the proposed two-step process is favorable to produce an Au electrode layer for the PSC device with a general thermal evaporator.

High Step-Up Converter with Hybrid Structure Based on One Switch

  • Hwu, K.I.;Peng, T.J.
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.4
    • /
    • pp.1566-1577
    • /
    • 2015
  • A novel high step-up converter is presented herein, which combines the conventional buck-boost converter, the charge pump capacitor and the coupling inductor. By doing so, a quite high voltage conversion ratio due to not only the turns ratio but also the duty cycle, so as to increase design feasibility. It is noted that the denominator of the voltage conversion ratio is the square of one minus duty cycle. Above all, there is no voltage spike across the switch due to the leakage inductance and hence no passive or active snubber is needed, and furthermore, the used switch is driven without isolation and hence the gate driving circuit is relatively simple, thereby upgrading the industrial application capability of this converter. In this paper, the basic operating principles and the associated mathematical deductions are firstly described in detail, and finally some experimental results are provided to demonstrate the effectiveness of the proposed high step-up converter.

A study of application for train station of step by step construction method of ADS (자율분산시스템 단계적 구축방식의 철도역 적용에관한 연구)

  • Ahn Jin;Kim Ryu-ho;Lee Young-Soo;Kim Eun-Hee;Hong Soon-Heum;Kim Young-Hoon;Park Bum-Hwan
    • Proceedings of the KSR Conference
    • /
    • 2005.05a
    • /
    • pp.843-848
    • /
    • 2005
  • Currently the train traffic control system is built wholly by one package construction. It is under variable circumstance such as variation of signalling equipment and station expansion. This condition reduces system reliability and availability. And the term of system change is longer than 10 years, so it is hard to update to the latest technology and the new function. In order to do the system should be replaced to new one completely. The step by step construction of ADS(Autonomous Decentralized System) is one of the solution. So the simulation of it on the real station help to find system requirement and verify good of online expansion and online test.

  • PDF