• 제목/요약/키워드: One line type

검색결과 806건 처리시간 0.03초

지역냉방용 아이스슬러리 수송시스템의 배관방식에 따른 특성 (Characteristics of the Ice Slurry Transportation System for District Cooling Depending on the Transportation Lines)

  • 이윤표;정재동;윤석만
    • 설비공학논문집
    • /
    • 제18권7호
    • /
    • pp.571-577
    • /
    • 2006
  • The characteristics of ice packing factor (IPF) at the ice slurry system using one line type are compared with the system using two lines type. The installation space for one transporting line is saved at the one line system. For the one line type, the ice packing factor is reduced along the downstream, but for the two lines type, the ice packing factor is fixed. For the one line system, mass flow rate in the main line is fixed along the down-stream, but for two lines system, the mass flow rate in the main line is reduced along the downstream. For one line system, along the down stream after IPF=0, the temperature at the main steam is increased, and the extracted mass flow is increased. The initial IPF, at which the IPF is not arrived at zero upto the final node, is proposed for the B area.

한전 배전 계통을 이용한 2단장주의 불평형 부하에 따른 중성선 전류의 영향에 관한 연구 (A Study on the Effects of Neutral Current by Unbalanced Load in Two Step Type Pole using KEPCO's Distribution System)

  • 박건우;서훈철;김철환;정창수;유연표;임용훈;이원정
    • 전기학회논문지
    • /
    • 제56권3호
    • /
    • pp.465-471
    • /
    • 2007
  • The one step type pole and two step type pole are used in KEPCO's distribution system. The neutral current increases in three-phase four-wire distribution system due to unbalanced load. Usually, power line and communication line are installed at contiguity by effect of topography in Korea. To this end, the damages such as electrostatic induction, electromagnetic induction and harmonic induction generated by induced voltage and current are occured in power line and communication line. This paper calculates the neutral current in KEPCO's distribution system using EMTP by composing various simulated conditions. Also, these results are verified by vector analysis.

튜브형 line mixer용 element의 비틀음 성형에 대한 연구 (study on twist forming of elements for tube type line mixers)

  • 김권희
    • 소성∙가공
    • /
    • 제5권2호
    • /
    • pp.165-175
    • /
    • 1996
  • the process of strip twisting is practiced for the manufacture of some commercial parts such as elements for tube type line mixers. A thin metal strip with rectangular cross section is twisted thru an angle greater than 180。. Initial geometry is altered in to a complex one with dimen-sional changes. In practice several tryouts are necessary to obtain required dimensional accu-racies. A simple analysis model is proposed to predict the dimensional changes forming torque and axial force.

  • PDF

한전 실 배전계통 모델을 이용한 1단 장주 중성선 전류 계산 (Neutral Current Calculation of the One Step Type Pole using KEPCO's Distribution System)

  • 서훈철;박건우;김철환;정창수;유연표;임용훈;설일호
    • 전기학회논문지
    • /
    • 제56권1호
    • /
    • pp.35-40
    • /
    • 2007
  • The one step type and two step type pole are used in distribution line. If the three phases are not balanced, the communication line can be damaged by induced voltage. This paper calculates the neutral current using KEPCO's distribution system model which is only composed by one step type pole. The used system model is modelled by using ATPDraw and the neutral current is calculated by using EMTP/MODELS. Many cases for abstracting the neutral current characteristics in KEPCO's distribution system are simulated and analyzed.

ON-LINE DYNAMIC SENSING OF SHIP'S ATTITUDE BY USE OF A SERVO-TYPE ACCELEROMETER AND INCLINOMETERS

  • Tanaka, Shogo;Nishifuji, Seiji
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1995년도 Proceedings of the Korea Automation Control Conference, 10th (KACC); Seoul, Korea; 23-25 Oct. 1995
    • /
    • pp.162-165
    • /
    • 1995
  • For an accurate on-line measurement of the ship's attitude the paper develops an intelligent sensing system which uses one servo-type accelerometer and two servo-type inclinometers appropriately located on the ship. By considering the dynamics of the servo-controlled rigid pendulums of the inclinometers, linear equations for the rolling and pitching of the ship are derived separately from each other. Moreover, one accelerometer is used for extracting the heaving signal. Through the introduction of linear dynamic models and the linear observation equations for the heaving, rolling and pitching, the on-line measurement of the three signals can be reduced to the state estimation of the linear dynamic systems. A bank of Kalman filters is adaptively used to achieve the on-line accurate state estimation and to overcome changes in parameters in the linear dynamic models.

  • PDF

On-Line 및 OFF-Line 겸용 전자화폐 (Electronic Money for On-Line and Off-Line)

  • 황욱선;신창균
    • 한국정보과학회논문지:컴퓨팅의 실제 및 레터
    • /
    • 제8권3호
    • /
    • pp.295-302
    • /
    • 2002
  • 이 논문에서는 전자화폐 시스템 사용의 기술적인 문제점에 관한 몇가지 해결방안을 제안한다. 그 해결책은 온/오프 라인 겸용 전자화폐, 원카드, 주문형 시스템, 카드 대 카드 이체 시스템 등이다. 이 대안들이 엔젤플러스 전자화폐 사례에서 소스코드로 기술되었다. 전자화폐는 IC형과 네트워크형으로 분류 한다. 그러나 그들은 통합되어야 한다 최종사용자는 편리성을 위하여 겸용으로 사용되기를 원한다. 이 논문에서는 사례연구에 의하여 온/오프 라인 겸용 전자화폐를 개발한다. 이 논문을 바탕으로 미래연구에서는 소비자지향의 다양한 기능을 소유한 전자화폐 개발이 진행되어야 할 것이다.

마이크로 스트립라인 집중소자를 이용한 일체형 SAW 듀플렉서의 최적설계 및 실험 (Optimal Design and Experiment of One Chip Type SAW Duplexers using Micro_Strip Line Lumped Elements)

  • 이승희;노용래
    • 한국전기전자재료학회논문지
    • /
    • 제16권7호
    • /
    • pp.647-655
    • /
    • 2003
  • Commonly used SAW duplexers have a difficulty on manufacture so that a transmission line is printed on the package or an LTCC multi-layer is needed because a quarter-wave transmission line which is a kind of an isolation network is applied to the SAW duplexers. In this study, new structures of one chip type SAW duplexers are proposed. In the proposed structure, Tx and Rx SAW ladder filters and isolation networks are located on a single 36LiTaO$_3$ piezoelectric substrate. The manufacture process is very simple than commonly used product. It is possible to improve tile performance by means of optimizing the micro-strip line lumped elements. It is easy to integrate and modulate with other surrounding components. The optimal design techniques can be applied to other kind of multi-port devices.

연주복 선호 디자인에 따른 패턴 연구 - 피아노와 성악 중심으로 - (A Study on Pattern of Concert Dress Preference Design)

  • 박성율;홍정민
    • 한국의류산업학회지
    • /
    • 제5권5호
    • /
    • pp.465-469
    • /
    • 2003
  • The present study revealed; that (1) The students majoring in a piano course were the preference type of the performance dress - best line was designed of upper form chest. It was 1.5cm shorter than armhole line, the princess line was preferred Top one piece without sleeves which was designed with slim by bottom line through west dart form best line. The expression method was showing embroidery and bidding, colors were in order to white, ivory, black and blue style. The material was in order to silk with glorious shinning, silk satin and race style. (2) The students majoring in a vocal music were the preference type of the performance dress - the princess line was designed shorter, the west line of back and forth was preferred the one piece of bulk style divided with three partitions. Neck line was 5cm shorter than the middle of back, 9cm shorter than the side neck position, 9cm shorter than the middle of forth, sweet heart neck line with circular sleeve designed 7cm shorter than the side neck position. Colors were in order to ivory, red and yellow style. The material was in order to silk with glorious shinning silk satin and race style.

20대 여성의 체형변화에 따른 원피스 드레스 원형연구 (A Study on One-Piece Dress Pattern According to the Somatotype Alteration of Women in their 20s)

  • 박주희;홍정민;윤진경
    • 한국의류산업학회지
    • /
    • 제7권4호
    • /
    • pp.407-412
    • /
    • 2005
  • This study is to establish the pattern for one piece dress which fits well to the women somatotype with different drop value and is functional and has high body fitness. Selected 2 testers from classified 4 types who were close to the average value and took twice dressing test. After successive correction and revision, patterns of one piece dress for each somatotype were established. M type ; Bust line is established to B/4+1.7 cm. Waist line is W/4+1.5+2.5 cm(dart amount) for front pattern and W/4+0.8+2 cm(dart amount) for back. Hip line is H/4+0.8 cm for front and H/4+0.8 cm for back and the bust dart amount is 2.5 cm. A type ; Bust line is established to B/4+1.7 cm. Waist line is W/4+1.5+2.5 cm (dart amount) for front pattern and W/4+0.8+2 cm(dart amount) for back. Hip line is H/4+1.5 cm for front and H/4+1 cm for back and the bust dart amount is 2.2 cm. X type ; Bust line is established to B/4+1.5 cm for front pattern and B/4+2 cm for back. Waist line is W/4+2+2.5 cm (dart amount) for front and W/4+1+2+1.4 cm(for two darts amount) for back. Hip line is H/4+1 cm for front and H/4+1.3cm for back and the bust dart amount is 2.8 cm. H type; Bust line is established to B/4+1.5 cm for front pattern and B/4+2cm for back. Waist line is W/4+1.7+2.5 cm (dart amount) for front and W/4+0.8+2 cm(dart amount) for back. Hip line is H/4+2 cm for front and H/4+1.5 cm for back and the bust dart amount is 2.8 cm. In order to achieve the objective evaluation on a new pattern in this study, the sensory evaluation for both Imwonja pattern and a new pattern in this study was completed. As a result of sensory evaluation, a new pattern of this study could accomplished a good appearance in reflecting characteristics of each types and could achieved the functional superiority than comparison pattern.

이중퀜치를 이용한 삼상변압기형 초전도한류기의 삼상지락 고장 종류에 따른 고장전류 제한 특성 분석 (Analysis on Fault Current Limiting Characteristics of Three-Phase Transformer Type SFCL using Double Quench According to Three-Phase Ground-Fault Types)

  • 이신원;한태희;임성훈
    • 한국전기전자재료학회논문지
    • /
    • 제36권6호
    • /
    • pp.614-619
    • /
    • 2023
  • The fault current limiting characteristics of three-phase transformer type superconducting fault current limiter (SFCL), which consisted of three-phase primary and secondary windings wound on E-I iron core, one high-TC superconducting (HTSC) element connected with the secondary winding of one phase and another HTSC element connected in parallel with other two secondary windings of two phases, were analyzed. Unlike other three-phase transformer type SFCLs with three HTSC elements, three-phase transformer type SFCL using double quench has the merit to perform fault current limiting operation for three-phase ground faults with two HTSC elements. To verify its proper three-phase ground fault current limiting operation, three-phase ground faults such as single-line ground, double-line ground and triple-line ground faults were generated in three-phase simulated power system installed with three-phase transformer type SFCL using double quench. From analysis of its fault current limiting characteristics based on tested results, three-phase transformer type SFCL using double quench was shown to be effectively operated for all three-phase ground faults.