• 제목/요약/키워드: On-line balancing

검색결과 136건 처리시간 0.028초

압축성 회전유체에서 발생하는 Taylor-Proudman 유동에 대한 점근해석 (An asymptotic analysis of the Taylor-Proudman flow in a rapidly-rotating compressible fluid)

  • 박준상;현재민
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.341-344
    • /
    • 2002
  • A matched asymptotic analysis is conducted for a compressible rotating flow in a cylindrical container when a mechanical and/or a thermal disturbance is imposed on the wall. The system Ekman number is assumed to be very small. The conditions for the Taylor-Proudman column in the interior, which were also given in the companion paper Park & Hyun, 2002) by means of the energy balancing analysis, have been re-derived. The concept of the variable, the energy content $e[{\equiv}T+2 {\alpha}^2 {\gamma}{\nu}]$, is reformulated, and its effectiveness in characterizing the energy transport mechanism is delineated. It is seen that, under the condition of the Taylor-Proudman column, numerous admissible theoretical solutions for interior flow exist with an associated wail boundary condition. Some canonical examples are illustrated with comprehensive physical descriptions. The differential heating problem on the top and bottom endwall disks is revisited by using the concept of the energy content. The results are shown to be in line with the previous findings.

  • PDF

Analysis and Control of a Modular MV-to-LV Rectifier based on a Cascaded Multilevel Converter

  • Iman-Eini, Hossein;Farhangi, Shahrokh;Khakbazan-Fard, Mahboubeh;Schanen, Jean-Luc
    • Journal of Power Electronics
    • /
    • 제9권2호
    • /
    • pp.133-145
    • /
    • 2009
  • In this paper a modular high performance MV-to-LV rectifier based on a cascaded H-bridge rectifier is presented. The proposed rectifier can directly connect to the medium voltage levels and provide a low-voltage and highly-stable DC interface with the consumer applications. The input stage eliminates the necessity for heavy and bulky step-down transformers. It corrects the input power factor and maintains the voltage balance among the individual DC buses. The second stage includes the high frequency parallel-output DC/DC converters which prepares the galvanic isolation, regulates the output voltage, and attenuates the low frequency voltage ripple ($2f_{line}$) generated by the first stage. The parallel-output converters can work in interleaving mode and the active load-current sharing technique is utilized to balance the load power among them. The detailed analysis for modeling and control of the proposed structure is presented. The validity and performance of the proposed topology is verified by simulation and experimental results.

Optimal DG Placement in a Smart Distribution Grid Considering Economic Aspects

  • Buaklee, Wirote;Hongesombut, Komsan
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권4호
    • /
    • pp.1240-1247
    • /
    • 2014
  • The applications of Distributed Generation (DG) in a smart distribution grid environment are widely employed especially for power balancing and supporting demand responses. Using these applications can have both positive and negative impacts on the distribution system. The sizing and location of their installations are the issues that should be taken into consideration to gain the maximum benefit from them when considering the economic aspects. This paper presents an application of the Bat Algorithm (BA) for the optimal sizing and siting of DG in a smart distribution power system in order to maximize the Benefit to Cost Ratio (BCR), subjected to system constraints including real and reactive power generation, line and transformer loading, voltage profile, energy losses, fault level as well as DG operating limits. To demonstrate the effectiveness of the proposed methodology and the impact of considering economic issues on DG placement, a simplify 9-bus radial distribution system of the Provincial Electricity Authority of Thailand (PEA) is selected for the computer simulation to explore the benefit of the optimal DG placement and the performance of the proposed approach.

품질개선 및 혁신활동에서 재무성과 측정모형의 개발 (Development of Financial Effect Measurement(FEM) Models for Quality Improvement and Innovation Activity)

  • 최성운
    • 대한안전경영과학회지
    • /
    • 제17권1호
    • /
    • pp.337-348
    • /
    • 2015
  • This research introduces the Financial Effect Measurement (FEM) models which measures both the improvement and the innovation performance of Quality Control Circle (QCC) and activities of Six Sigma. Concepts and principle of Comprehensive Income Statement (CIS), Balanced Scorecard (BSC), Time-Driven Activity Based-Costing (TDABC) and Total Productive Maintenance (TPM) are applied in order to develop the 4 FEM models presented in this paper. First of all, FEM using CIS depicts the improvement effects of production capacity and yield using relationships between demand and supply, and line balancing efficiency between bottleneck process and non-bottleneck processes. Secondly, cause-and-effect relation of Key Performance Indicator (KPI) is used to present Critical Success Factor (CSF) effects for QC Story 15 steps of QCC and DMAIC (Define, Measure, Analyze, Improve, and Control) of Six Sigma. The next is FEM model for service management innovation activities that uses TDABC to calculate the time-driven effect for improving the indirect activities according to the cost object. Lastly, FEM model for TPM activities presents the interpretation of improvement effect model of TPM Capital Expenditure (CAPEX) and Operating Expenditure (OPEX) maintenance using profit, cash and Economic Added Value (EVA) as metrics of enterprise values. To better understand and further investigate FEMs, recent cases on National Quality Circle Contest are used to evaluate new financial effect measurement developed in this paper.

SCADA 기능과 전기품질 온라인 감시 및 배전설비 열화감시 기능을 갖는 배전지능화 시스템 개발 (Development of intelligent distribution automation system with the function of substation SCADA, power quality monitoring and diagnosis condition monitoring)

  • 하복남;이성우;신창훈;서인용;장문종;박민호;윤기갑;송일근;이병성;이정철;남궁원
    • 전기학회논문지
    • /
    • 제59권10호
    • /
    • pp.1776-1786
    • /
    • 2010
  • Intelligent distribution automation system have total monitoring and control capability. The system covers substation, distribution network, distributed generations and customers at HV system. Various intelligent distribution facilities installed at distribution systems have voltage sensor, current sensor, aging monitoring sensor. Intelligent Feeder Remote Terminal Unit (IFRTU) tied to intelligent distribution facilities process information from facilities and it checks information of fault, power quality and aging of distribution facilities. The information is transmitted to master station through communication line. The master station have remote monitoring system covers substation, distribution network, distributed generations and customers. It also have various application programs that maintain optimal network operation by using information from on-site devices.

300MW급 증기터빈의 베어링 윤활유 온도조정에 의한 오일휩 제거방법에 관한 연구 (A Study of Bearing Oil Whip Treatment in 300MW Steam Turbine with Oil Temperature Change)

  • 황달연;김화영;문승재;이재헌
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.244-247
    • /
    • 2008
  • The phenomena of oil whip in steam turbine takes place for the un-balancing force between rotor shaft and bearing oil film. The several parameters that affect onset of oil whip have been well known. However, the major parameter of oil whip is shaft mis-alinement. A oil whip causes the high vibration and the shutdown of rotor system. We mostly stop the steam turbine to adjust a shaft re-alinement concerning oil whip. In this case, It needs many costs for maintenance and long shutdown times. In this study, we study and observe the oil whip of the 300MW steam turbine in many years and we conduct the field test for another steam turbine for reducing vibration from oil whip. The results of this study are that a oil whip takes place with a particular rotating speed or a particular turbine output and the oil temperature change is a very effective method for on-line oil whip treatment.

  • PDF

디지털 도어록 혼류공정 최적화 설계를 위한 컴퓨터 시뮬레이션 연구 (A Simulation Study for Analyzing Digital Doorlock Mixed Assembly Process)

  • 윤철호;유기훈;이인철;변의석
    • 한국산학기술학회논문지
    • /
    • 제10권7호
    • /
    • pp.1439-1445
    • /
    • 2009
  • 본 논문에서는 디지털 도어록 혼류 조립 공정에서의 시뮬레이션 분석모델을 제안한다. 이 모델의 목적은 디지털 도어록 생산 공정 설계에 있어서 여러 대안의 성능에 대해 평가하는 것이다. 시뮬레이션 모델을 개발하기 위하여 먼저 시간연구가 수행되었다. 동시에 ARENA 시뮬레이션 도구를 이용하여 공정분석을 수행하였다. 그 결과 현재의 디지털 도어록 혼류 생산 공정은 여러 품종의 수요 증가에 적절한 생산방식을 제공하지 못한다는 문제점을 발견하였고 이를 개선하기 위한 대안을 제안하였다.

Nursing Students' Experience of Sexual Harassment During Clinical Practicum: A Phenomenological Approach

  • Kim, Mijong;Kim, Taeim;Tilley, Donna Scott;Kapusta, Ann;Allen, Denise;Cho, Ho Soon Michelle
    • 여성건강간호학회지
    • /
    • 제24권4호
    • /
    • pp.379-391
    • /
    • 2018
  • Purpose: To describe nursing students' experience of sexual harassment during clinical practicum. Methods: An interpretive phenomenological qualitative approach was used to understand contextual experiences of participants. Individual in-depth interviews were conducted to collect data from thirteen nursing students who experienced sexual harassment during clinical practice in general hospitals at D metropolitan city. All interviews were recorded and transcribed into Korean and English. Transcripts were analyzed using the data analysis method described by Diekelmann, Allen, and Tanner. Results: The following 12 themes emerged from the data: 'unprepared to respond', 'lack of education', 'unsure about when behavior crosses the line', 'power differential for nursing students', 'balancing self-preservation with obligations to patients', 'shame', 'feeling responsible for not being able to prevent the harassment', 'impact on patient care', 'fear of what might have happened', 'fear of repercussions', 'long term impact', and 'peer support'. Conclusion: Participants in this study described feeling an obligation to care for their patients. However, they seemed to be unable to balance this while feeling vulnerable to sexual harassment with strong negative feelings. Helping students recognize and effectively deal with sexual harassment is a critical element to assure quality learning for participants and maintain quality of care during clinical practice.

온라인 전기자동차의 대용량 배터리를 위한 전압-온도를 이용한 패시브 셀 밸런싱 에이전트 (A Passive Cell Balancing Agent by using Voltage and Temperature for Large Batteries in Online Electric Vehicles)

  • 오근현;김종우;서동관;김종돈
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2011년도 춘계학술발표대회
    • /
    • pp.1078-1081
    • /
    • 2011
  • 친환경적 전기자동차에 대한 관심이 커짐에 따라 전력의 효율적인 저장과 관리를 위한 대용량 배터리에 대한 연구가 활발히 진행 중이다. 배터리 용량의 극대화, 안정성, 그리고 수명 등을 위한 다양한 셀 밸런싱 방법들이 소개되고 있다. 기존 패시브 셀 밸런싱 방법은 하드웨어의 기능을 수행하는 것에 초점을 맞추어 배터리 상태에 따라 다양한 반응을 정의하기 어려움으로 효과적인 운용에 한계가 있다. 본 논문에서는 소프트웨어 에이전트 모델을 적용한 배터리 셀 밸런싱 시스템을 제안하며 에이전트가 현재 전압과 온도를 고려한 셀 밸런싱을 수행함으로 고속 충전시에 발생하는 셀간 전압차를 최소화 한다. 또한 충전의 신속성과 셀 전압 안정성을 유지한다. 현재 연구 개발 중인 카이스트 온라인 전기자동차에서 사용 예정인 배터리 관리시스템 기반 시뮬레이션을 수행함으로 제안하는 방법의 유용성을 입증하였다.

Relation between Huggins Constant and Compatibility of Binary Polymer Mixtures in the Aqueous Ternary Systems

  • Isamu Inamura;Makoto Kittaka;Tatsuya Aikou;Kazuhiko Akiyama;Tomoyuki Matsuyama;Masatsugu Hiroto;Hirade, Ken-ichi;Yuji Jinbo
    • Macromolecular Research
    • /
    • 제12권2호
    • /
    • pp.246-250
    • /
    • 2004
  • We have classified a number of aqueous ternary systems containing two different polymers into three types by focusing on the deviation of the Huggins constant k'from the additivity line. Systems of type I have negative deviations of k'; the repulsive interaction between the two different polymers dominates. In systems of type II, k' almost follows the additivity relation; the repulsive and attractive interactions between the two different polymers are balancing. Type III systems have positive deviations of k'; the attractive interactions are relatively dominant. This classification of systems is supported by the fact that the positive and negative deviations of k' from the additivity line also correspond to the sign of interaction parameter between polymer 2 and 3, Δb$\_$23/. Furthermore, we have verified the relatively high compatibility between dextran and poly(vinyl alcohol) by determining the binodal concentration of a liquid-liquid phase separation for a water/dextran/poly(vinyl alcohol) system, which is classified as type III. Thus, we found that the compositional dependence of k' closely relates to the compatibility of binary polymer mixtures in aqueous ternary systems.