• Title/Summary/Keyword: On Line Maintenance

Search Result 630, Processing Time 0.021 seconds

Research on Navigation-aids Information System

  • Zhang, Xing-Gu;Peng, Guo-Jun;Xiang, Lu;Chen, Xin
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2006.10a
    • /
    • pp.56-62
    • /
    • 2006
  • This thesis researches on the application of computer, modern communication, GIS, GPS, AIS and World-Wide-Web in the field of navigation-aids information system, and has realized an integrated system consisted of navigation-aids information GIS platform, navigation-aids monitoring system and navigation-aids information distribution system. This system has strong integration capability, and has realized navigation-aids information distribution based on WEBGIS at the first time. It strongly promotes navigation-aids daily management and maintenance, and this system provides technique guarantee fur ships and marine departments to acquire navigation-aids information in time, by rule and line expediently.

  • PDF

An improved cross-correlation method based on wavelet transform and energy feature extraction for pipeline leak detection

  • Li, Suzhen;Wang, Xinxin;Zhao, Ming
    • Smart Structures and Systems
    • /
    • v.16 no.1
    • /
    • pp.213-222
    • /
    • 2015
  • Early detection and precise location of leakage is of great importance for life-cycle maintenance and management of municipal pipeline system. In the past few years, acoustic emission (AE) techniques have demonstrated to be an excellent tool for on-line leakage detection. Regarding the multi-mode and frequency dispersion characteristics of AE signals propagating along a pipeline, the direct cross-correlation technique that assumes the constant AE propagation velocity does not perform well in practice for acoustic leak location. This paper presents an improved cross-correlation method based on wavelet transform, with due consideration of the frequency dispersion characteristics of AE wave and the contribution of different mode. Laboratory experiments conducted to simulate pipeline gas leakage and investigate the frequency spectrum signatures of AE leak signals. By comparing with the other methods for leak location identification, the feasibility and superiority of the proposed method are verified.

Framework for Estimating Appropriate Construction Duration of CFRD in the Planning Phase

  • Kim, In Kyum;Kim, Kyong Ju;Yun, Won Gun
    • International conference on construction engineering and project management
    • /
    • 2015.10a
    • /
    • pp.604-605
    • /
    • 2015
  • To secure quality of dam construction needs appropriate construction duration. Tight construction schedule may have negative influence on infrastructure quality, work safety and maintenance cost. It is necessary to reflect proper construction duration in the planning phase. There have been standards for estimating construction duration of building and industrial complex development but dam construction have not. In order to estimate construction duration of CFRD, feasible study reports and design reports were analyzed to acquire available information. After that, considering on construction duration methods such as comparison with similar cases, approximate estimating formula, approximate quantity assumption were adapted to Critical Path items. Hence, this study present framework for construction duration estimating of CFRD in the planning phase. This framework can be applied other types of dam along the same line.

  • PDF

A Development of The Dynamic Reconfigurable Components based on Software Product Line : Guided Weapon System (소프트웨어 프로덕트 라인공학을 적용한 동적 재구성 컴포넌트 개발 : 유도무기체계)

  • Lee, Jae-Oh;Lee, Jae-Jin;Suk, Jee-Beom;Seo, Yoon-Ho
    • Journal of the Korea Society for Simulation
    • /
    • v.19 no.4
    • /
    • pp.179-188
    • /
    • 2010
  • The concern of Software Product Line(SPL) engineering is spreading widely because the program or product developers are able to satisfy the customer's demands quickly and give a way to handle maintenance efficiently. SPL is a reuse paradigm that reuse common parts and adopts variable parts optionally to form a differentiated product by analyzing domains. Purposes of this paper are to design an architecture which has a dynamic reconfiguration function and to develop basic components which are the basic unit of reconfiguration to raise the reuse level of the guided weapon system using the SPL. Initially we design an architecture and define basic components for developing a dynamic reconfigurable components based on SPL. Then we develop the composer for physical components and behavior components referenced by behavior models of OneSAF.

Development of On-tine Partial Discharge Monitoring System for High-Voltage Motor Stator Windings (고압 전동기 고정자 권선의 운전중 절연감시 시스템 개발)

  • Hwang, D.H.;Sim, W.Y.;Park, D.Y.;Gang, Dong-Sik;Kim, Y.J.;Song, S.O.;Kim, H.D.
    • Proceedings of the KIEE Conference
    • /
    • 2001.11a
    • /
    • pp.224-226
    • /
    • 2001
  • In this paper, a novel high-voltage motor monitoring system (HVMMS) is proposed. This system monitors the insulation condition of the stator winding by on-line measurements of partial discharge (PD). Sensor, EMC (Epoxy-Mica Coupler) is used for PD measurement PD signals are continuously measured and digitized with a peak-hold A/D converter to build the database of the high-voltage motor's insulation condition. Also, this system can communicate with the central monitoring system via RS-485. This helps more efficient operation and maintenance of the generator.

  • PDF

A Metamodeling Approach for Leader Progression Model-based Shielding Failure Rate Calculation of Transmission Lines Using Artificial Neural Networks

  • Tavakoli, Mohammad Reza Bank;Vahidi, Behrooz
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.6
    • /
    • pp.760-768
    • /
    • 2011
  • The performance of transmission lines and its shielding design during a lightning phenomenon are quite essential in the maintenance of a reliable power supply to consumers. The leader progression model, as an advanced approach, has been recently developed to calculate the shielding failure rate (SFR) of transmission lines using geometrical data and physical behavior of upward and downward lightning leaders. However, such method is quite time consuming. In the present paper, an effective method that utilizes artificial neural networks (ANNs) to create a metamodel for calculating the SFR of a transmission line based on shielding angle and height is introduced. The results of investigations on a real case study reveal that, through proper selection of an ANN structure and good training, the ANN prediction is very close to the result of the detailed simulation, whereas the Processing time is by far lower than that of the detailed model.

A Fault Effect to Induced Voltage of Gas Pipeline in Transmission Systems (송전계통에서 고장에 따른 Gas Pipeline 유도전압 분석)

  • Kim, Hyun-Soo;Rhee, Sang-Bong;Kim, Chul-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.10
    • /
    • pp.1720-1725
    • /
    • 2008
  • Because of the continuous increasing of energy consumption, metallic pipelines are widely used to supply services to customers such as gas, oil, water, etc. Most common metallic pipelines are underground and are now frequently being installed in nearby electric power lines. In recent years, buried gas pipeline close to power lines can be subjected to hazardous induction effects, especially during single line to ground faults. because it can cause corrosion and it poses a threat to the safety of workers responsible for maintenance. Accordingly, it is necessary to take into consideration for analysis of induced voltage on gas pipelines in transmission lines. This paper analyzed the induced voltage on the gas pipelines due to the 154kV transmission lines in normal case and in different faulty case conditions using EMTP (Electro-Magnetic Transients Program).

Development on Integrated Management System for Outdoor Light Facility (야외 조명시설 통합관리 시스템 개발에 관한 연구)

  • Jeon, Chang-Dae;Chang, Byong-Kun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.8
    • /
    • pp.15-21
    • /
    • 2006
  • This paper concerns developing an integrated online/offline light facility management system using internet and building a database system for control box and street light. Also, we designed the system to minimize the disparity with the conventional management system by referring to an old management ledger format. Thus, the proposed method may enable the system manager to administer the light facility efficiently and to reduce the manpower and maintenance cost, economically.

An innovative design method for nonlinear tuned mass damper

  • Li, Luyu;Du, Yongjia
    • Structural Monitoring and Maintenance
    • /
    • v.5 no.2
    • /
    • pp.261-272
    • /
    • 2018
  • The commonly used TMD design method in the project assumes the TMD has pure linearity. However, in real engineering TMD will exhibit nonlinear behaviors. Without considering the nonlinearity of TMD, the control effect of the TMD that is designed by the linear design method, may be worse and even enlarge the structural response. In this paper, based on the previous study results of nonlinear TMD, the improved design method for engineering application is proposed. The linear design method and the improved design method are compared. Taking the best parameter obtained by the improved design method is less than or equal to 90% of that obtained by the original design method as the dividing line. The critical nonlinear coefficient, reaching which value the improved design method needs to be used, is given. Finally, numerical simulations on two engineering examples are conducted to proof the results.

Human Hazard by Outdoor Electrical Facilities in Submerged Area (옥외 전기시설물 침수시 누설전류에 의한 인체영향)

  • 하태현;이현구;배정효;김대경
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.12
    • /
    • pp.602-607
    • /
    • 2003
  • We show three-dimensional distribution of voltages resulted from the leakage current originated from outdoor electrical facilities in a submerged area. In case these facilities are grounded by the neutral line multiple grounding method, the existence of ungrounded electrical facilities can cause a disastrous effect on near-by passengers. In order to investigate this situation, we installed a real-scale test field for the experiment type I (for the leakage current path between a enclosure grounded electrical facility and another enclosure grounded one), and that for the experiment type II (for the leakage current path between a enclosure grounded electrical facility and another ungrounded one). For both cases, we carried out three-dimensional monitoring of the voltage distribution while varying additional conditions such as the exposure of the underground cables and the finishing of cable connection part. The result shows that a disastrous effect on human safety can arise from the leakage current without a pertinent measure for the construction and maintenance of outdoor electrical facilities.