• Title/Summary/Keyword: Oil-paper insulation

Search Result 149, Processing Time 0.03 seconds

Analysis of Produced By-products Due to Oil/Paper Degradation on Power Transformers (전력용 변압기의 열화에 의해 생성된 부산물의 분석)

  • Kim, Jae-Hoon;Han, Sang-Ok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.9
    • /
    • pp.1561-1565
    • /
    • 2007
  • According to thermal degradation on power transformers, it is known that electrical, mechanical and chemical characteristics for power transformer's oil-paper are changed. In the chemical property, especially, when the kraft paper is aged, the cellulose polymer chains break down into shorter lengths. It causes decrease in both tensile strength and degree of polymerization of paper insulation. Also the paper breakdown is accompanied by an increase in the content of various furanic compounds within the dielectric liquid. It is known that furanic components in transformer oil come only from the decomposition of insulating paper rather than from the oil itself. Therefore the analysis of furanic degradation products provides a complementary technique to dissolved gas analysis for monitoring transformers when we evaluate the aging of insulating paper by the total concentration of carbon monoxide and carbon dioxide dissolved in oil only. Recently, the analysis of furanic compounds by high performance liquid chromatography(HPLC) using IEC 61198 method for estimating degradation of paper insulation in power transformers has been used more conveniently for assessment of oil-paper. It is know that the main products which is produced by aging are 2-furfuryl alcohol, 2-furaldehyde(furfural), 2-furoic acid, 2-acetylfuran, 5-methyl-2-furaldehyde, and 5-hydroxymethyl-2-furaldehyde. For investigating the accelerated aging process of oil-paper samples we manufactured accelerating aging equipment and we estimated variation of insulations at $140^{\circ}C$ temp. during 500 hours. Typical transformer proportions of copper, silicon steel and iron have been added to oil-paper insulation during the aging process. The oil-paper insulation samples have been measured at intervals of 100 hours. Finally we have analyzed that 2-furoic acid and 2-acetylfuran products of furanic compounds were detected by HPLC, and their concentrations were increased with accelerated aging time.

Electrical Breakdown Properties of Oil-paper Insulation under Pulsating Voltage Influenced by Temperature

  • Bao, Lianwei;Li, Jian;Zhang, Jing;Li, Xudong
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.6
    • /
    • pp.1735-1743
    • /
    • 2016
  • Insulation of valve-side windings in converter transformer withstands pulsating voltages, which will produce more serious insulation problems. In this paper, the electric breakdown experiments of oil-paper insulation specimens were executed at pulsating voltages and different temperatures. Experiment and analysis results showed that the breakdown voltage decreased with increasing temperature under pulsating voltage. The influence of temperature proves to be more significant once the temperature exceeds a limitation threshold. A fitting formula between breakdown voltage and the temperature was reported. Finally, in order to clearly understand the breakdown properties under pulsating voltage, the electric field distribution and space charge behavior under pulsating voltage at different temperature were discussed.

Electrical Properties of Liquid Insulation as a Function of Temperature (온도에 따른 액체 절연유의 전기적 특성 )

  • Tae-Hee Kim;Yong-Sung Choi
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.37 no.3
    • /
    • pp.280-285
    • /
    • 2024
  • In this paper, the electrical properties of liquid insulating oil were analyzed by changing the ambient temperature change at 10℃ in-tervals from 0℃ to 30℃ through an insulation breakdown experiment in order to analyze the insulation performance of liquid in-sulating oil that varies according to temperature changes. As a result, it was confirmed through experiments that the lower the am-bient temperature, the higher the insulation breakdown voltage, depending on both the electrode shape and the electrode interval, and it was determined that the lower the ambient temperature, the higher the insulation performance of the liquid insulating oil.

Space Charge Behavior of Oil-paper Insulation Thermally Aged under Different Temperatures and Moistures

  • Zhou, Yuan-Xiang;Huang, Meng;Chen, Wei-Jiang;Jin, Fu-Bao
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.1124-1130
    • /
    • 2015
  • Moisture and high temperature are the most important factors that lead to the ageing of oil-paper insulation, but the research about space charge characteristics of oil-paper insulation does not take the combined effect of ambient temperature, moisture and thermal ageing into account. The pulsed electroacoustic (PEA) method was used to investigate the influence of moisture and temperature on space charge characteristics of oil paper at different ageing stages. The results showed that moisture could speed up formation of space charge in oil paper when water concentration was low, but the formation was restrained if the water concentration was high. At the beginning of thermal ageing, heterogeneous charge accumulation had predominance, but it gradually changed to homogeneous charge injection with ageing. It was believed that moisture concentration could speed up ageing and enhance charge accumulation on one hand, and accelerate or slow down the establishment speed of space charge on the other hand, therefore, charge accumulation type changed with ageing. The more seriously the oil-paper insulation was thermally aged, the deeper the trap energy level was, hence more space charge was trapped, which could be speeded up by increasing the ageing temperature, but the effect of ambient temperature did not fit the Arrhenius law.

Partial Discharge Process and Characteristics of Oil-Paper Insulation under Pulsating DC Voltage

  • Bao, Lianwei;Li, Jian;Zhang, Jing;Jiang, Tianyan;Li, Xudong
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.2
    • /
    • pp.436-444
    • /
    • 2016
  • Oil-paper insulation of valve-side windings in converter transformers withstand electrical stresses combining with AC, DC and strong harmonic components. This paper presents the physical mechanisms and experimental researches on partial discharge (PD) of oil-paper insulation at pulsating DC voltage. Theoretical analysis showed that the phase-resolved distributions of PDs generated from different insulated models varied as the increase of the applied voltages following a certain rule. Four artificial insulation defect models were designed to generate PD signals at pulsating DC voltages. Theoretical statements and experimental results show that the PD pulses first appear at the maximum value of the applied pulsating DC voltage, and the resolved PD phase distribution became wider as the applied voltage increased. The PD phase-resolved distributions generated from the different discharge models are also different in the phase-resolved distributions and development progress. It implies that the theoretical analysis is suitable for interpretation of PD at pulsating DC voltage.

Research on Dielectric Characteristics of Environmental-Friendly Vegetable Insulation Oil for the Pole Transformer (주상변압기 적용을 위한 친환경 식물성절연유의 절연특성 연구)

  • Kwag, Dong-Soon
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.6
    • /
    • pp.81-85
    • /
    • 2010
  • In recent years, environmental concerns have been raised on the use of poorly biodegradable fluids in electrical apparatus in regions where spills from leaks and equipment failure could contaminate the surroundings. The vegetable insulation oils are highly biodegradable, have negligible effect on the environment, human health and ecosystem. Therefore, to assure their safe use in electrical power systems, it may require some processing and modification to improve some of their physical, chemical, thermal and electrical properties. This paper provides a comparative results of the electrical breakdown properties of several vegetable insulation oils and mineral oil to use as dielectric fluid in environmental-friendly pole transformer. Also, the electrical breakdown property of the Nomex and kraft insulation papers in vegetable insulation oil is examined.

A Study on Corona Inception Voltage and Dielectric Characteristics of Thermally Aged Mineral and Vegetable Insulation Oil in Medium Voltage Power Transformer (식물유 및 광유를 사용한 배전변압기의 열열화에 따른 절연유의 코로나 개시전압 및 전기적 특성에 대한 연구)

  • Jeong, Jung-Il;Huh, Chang-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.12
    • /
    • pp.1745-1750
    • /
    • 2017
  • Starting from the distribution transformer, the insulation oil for the oil immersed power transformer is being used to convert the vegetable oil from the existing mineral oil. Vegetable oil is better in temperature characteristics and insulation performance, is not toxic, and has better biodegradable characteristic than that of mineral oil. In order to investigate the corona inception voltage and dieclectic charateristics of the two insulating oils, three oil immersed transformers using mineral oil and vegetable oil were made and thermal cyclic aged. In this paper, the changes in the corona discharge inception voltage, chemical and electrical properties of the two sampled insulating oils from the transformers had been studied.

Optimal Design of an Antenna for the Detection of Partial Discharges in Insulation Oil (절연유중 부분방전 검출을 위한 안테나의 최적 설계)

  • Lee, Jung-Yoon;Jo, Hyang-Eun;Park, Dae-Won;Kil, Gyung-Suk;Oh, Jae-Geun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.4
    • /
    • pp.309-314
    • /
    • 2013
  • This paper dealt with the radiated electromagnetic wave detection of partial discharge (PD) in oil for insulation diagnostics of oil-immersed transformers. Three types of electrode system were fabricated to simulate the insulation defects that could occur in oil-immersed transformers. Frequency components of radiated electromagnetic wave in oil was measured by broadband bi-conical antennas of 300 MHz~2 GHz and a spectrum analyzer of 9 kHz~3 GHz. Frequency component of electromagnetic waves from PD in oil were highly distributed at 500 MHz. From the result, a narrow-band monopole antenna with the center frequency of 500 MHz was fabricated. We could detect PD signal in insulation oil without an influence of external noise by a measurement system which consists of the prototype monopole antenna, a LNA (Low Noise Amplifier), an oscilloscope and a spectrum analyzer.

Study on Vegetable Oil Application of the Pole Transformer (식물성절연유의 주상변압기 적용 연구)

  • Kwag, Dong-Soon;Kim, Sang-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2009.04a
    • /
    • pp.169-171
    • /
    • 2009
  • In recent years, environmental concerns have been raised on the use of poorly biodegradable fluids in electrical apparatus in regions where spills from leaks and equipment failure could contaminate the surroundings. For development of the environmental-friendly pole transformer using vegetable oil, we discussed the insulation construction of the transformer and the dielectric characteristics of the Nomex insulation paper in vegetable oil. Based on the experimental data, the insulation of the transformer is designed.

  • PDF

Positioning of Partial Discharge in Insulation Oil (유중 부분방전의 위치 추정)

  • Kil, Gyung-Suk;Park, Dae-Won;Jang, Un-Yong;Seo, Dong-Hoan;Park, Hee-Chul
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1861-1867
    • /
    • 2010
  • This paper described the positioning algorithm of partial discharge in insulation oil by acoustic method for the application of an on-line diagnosis in oil-immersed transformers. In the experiment, five AE sensors having the resonant frequency of 150 kHz were used, and a signal conditioner was fabricated. A needle-plane electrode system which is composed of a needle with a curvature radius of $10{\mu}m$ and a plane electrode with a diameter of 60 mm was installed to simulate partial discharges in insulation oil. From the time difference of arrival (TOA) of acoustic signal, we calculated the location of partial discharge in insulation oil. In the experiment, an algorithm of positioning of PD occurrence by the time difference of arrival was proposed. From the experimental results, the positioning error of PD calculated by three AE sensors was within 4%.

  • PDF