• 제목/요약/키워드: Oil-Immersed Transformer

검색결과 55건 처리시간 0.023초

최상부 유온 상승 특성을 이용한 100kVA 이하 유입식 배전용 변압기의 과부하 판정 기준 (Overload Criterion of Mineral-Oil-immersed Distribution Transformers Rated 100kVA and Less Using the Characteristics of Top-Oil Temperature Rising)

  • 윤상윤;김재철;박창호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권11호
    • /
    • pp.559-567
    • /
    • 2002
  • This paper presents the general recommendations for the overload criterions of mineral-oil-immersed distribution transformers rated 100kVA and less. For this purpose, we analyze the characteristics of top-oil temperature rising for mineral-oil-immersed power distribution transformer rated 100kVA and less, manufactured in Korea, In order to analyze the characteristics of top-oil temperature rising due to the distribution transformer loading, we performed experiments at KERI (Korea Electrical Research Institute) from December 2000 to May 2001. The restraint of ambient temperatures for the experiment results is solved using the results of foreign standards. Finally, we present the overload criterions of distribution transformer for summer and winter season, respectively.

유입변압기용 절연유의 절연파괴특성 (Electrical Breakdown Properties of Insulating Oils for oil-immersed transformer)

  • 이인성;신현택;이종필;이수원;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.605-608
    • /
    • 2001
  • With the intention of investigating the breakdown properties of oil-immersed transformer oils in temperature range of 20∼100[$^{\circ}C$], we are made researches AC breakdown in the gap of 500∼2,500[$\mu\textrm{m}$]. The classification for the physical properties of oil for oil-immersed transformer by FTH and $^1$H-NMR experiments was confirmed to type of mineral oils. As the dependance of breakdown properties due to electrode gap length variation, breakdown voltage was found increasing according to the increase of gap, while dielectric strength was decreasing. As a result the characteristics for AC breakdown, It goes to prove that the breakdown voltage was increased to 90[$^{\circ}C$] but decreased over 90[$^{\circ}C$] in the temperature range. Also, breakdown voltage was found increasing in the increase of gap and the rising of temperature according to Weibull distribution.

  • PDF

식물유 및 광유를 사용한 배전변압기의 열열화에 따른 절연유의 코로나 개시전압 및 전기적 특성에 대한 연구 (A Study on Corona Inception Voltage and Dielectric Characteristics of Thermally Aged Mineral and Vegetable Insulation Oil in Medium Voltage Power Transformer)

  • 정중일;허창수
    • 전기학회논문지
    • /
    • 제66권12호
    • /
    • pp.1745-1750
    • /
    • 2017
  • Starting from the distribution transformer, the insulation oil for the oil immersed power transformer is being used to convert the vegetable oil from the existing mineral oil. Vegetable oil is better in temperature characteristics and insulation performance, is not toxic, and has better biodegradable characteristic than that of mineral oil. In order to investigate the corona inception voltage and dieclectic charateristics of the two insulating oils, three oil immersed transformers using mineral oil and vegetable oil were made and thermal cyclic aged. In this paper, the changes in the corona discharge inception voltage, chemical and electrical properties of the two sampled insulating oils from the transformers had been studied.

100kVA 이하 유입식 배전용변압기의 과부하 판정기준 설정 (Overload Criterion of Mineral-Oil-Immersed Distribution Transformers Rated 100kVA and Less)

  • 윤상윤;김재철;이영석;박창호;손화영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.6-8
    • /
    • 2001
  • This paper covers general recommendations for top-oil temperature rising of mineral-oil-immersed power distribution transformer rated 100kVA and less, manufactured in Korea. In order to analyze the top-oil temperature rising due to the distribution transformer loading we performed experiments for oil-immersed distribution transformer, manufactured in domestic at KERI(Korea Electrical Research Institute) from December 2000 to May 2001. The magnitude of loading were changed, and the top-oil temperatures for each time were measured. Finally, we present the overload criteria of distribution transformer for summer and winter season in domestic. respectively.

  • PDF

유입변압기용 절연유의 절연파괴특성 (Electrical Breakdown Properties of Insulating Oils for oil-immersed transformer)

  • 이인성;신현택;이종필;이수원;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집 Vol.14 No.1
    • /
    • pp.605-608
    • /
    • 2001
  • With the intention of investigating the breakdown properties of oil-immersed transformer oils in temperature range of $20\sim100[^{\circ}C]$, we are made researches AC breakdown in the gap of $500\sim2500[{\mu}m]$. The classification for the physical properties of oil for oil-immersed transformer by FTIR and H-NMR experiments was confirmed to type of mineral oils. As the dependance of breakdown properties due to electrode gap length variation, breakdown voltage was found increasing according to the increase of gap, while dielectric strength was decreasing. As a result the characteristics for AC breakdown, It goes to prove that the breakdown voltage was increased to $90[^{\circ}C]$ but decreased over $90[^{\circ}C]$ in the temperature range. Also, breakdown voltage was found increasing in the increase of gap and the rising of temperature according to Weibull distribution.

  • PDF

활선중 절연유 분석을 통한 유입변압기 건전성 평가 방법에 관한 연구 (A Study on the Health Evaluation Method of Oil-immersed Transformer through Analysis of Insulating Oil)

  • 신연진;임재용
    • 한국안전학회지
    • /
    • 제38권6호
    • /
    • pp.1-8
    • /
    • 2023
  • The health state of the oil transformer is evaluated by the age of use and the state of internal defects. Mineral Oil, used as an insulator for oil transformers, creates specific gases and compounds through chemical reactions caused by heat, moisture, and partial discharge inside the transformer. It is possible to determine the aging and defect of the transformer through these gases and compounds. So, it is an important indicator to evaluate the health of a transformer. In this study, factors for assessing the health of transformers were hierarchically categorized, and key factors for each hierarchy were selected for design weighting. These weights were determined through surveys conducted with experts in the fields of transformer design, operation, and quality. For the health of a transformer, defect-related factors are approximately three times more important than factors related to aging. Additionally, defect-related factors showed a higher weighting for gases generated at high temperatures. Furthermore, Furan was determined to have a high weight, directly associated with insulating paper aging. Based on these findings, a health index was proposed, and a comparative analysis was conducted by categorizing 40 operational transformers into normal and comparison groups to evaluate and validate it.

유침절연 변압기에서 연속적 수분제거 유효성에 관한 연구 (Study on the Effectiveness of Continuous Water Removal in Oil Immersed Transformers)

  • 선종호;황돈하;김진수
    • 조명전기설비학회논문지
    • /
    • 제30권2호
    • /
    • pp.20-25
    • /
    • 2016
  • This paper describes the effectiveness of continuous water removal in oil immersed transformers. Insulation oil in which insulation papers were immersed were prepared for tests and water concentrations in oil with heating time were measured at five oil temperatures. Also, the tests that water dissolved in $100^{\circ}C$ oil was removed at once and continuously at $50^{\circ}C$ and $100^{\circ}C$ were performed for consideration of effective method for water removal. Test results indicated that the oils for water measurement have to be extracted at similar temperatures and water in oil has to be continuously removed at higher temperatures for more effective water management of transformers.

지하철 유입 변압기의 FN 선도를 이용한 위험도 평가 연구 (A Study on the Risk Assessment for Oil Immersed Transformer of Subway with FN curve)

  • 최승혁;이종우
    • 전기학회논문지
    • /
    • 제63권8호
    • /
    • pp.1152-1158
    • /
    • 2014
  • In Modern society, various important systems is operated such as nuclear plant, chemistry industry, railway system and so on. But these systems can cause high risky accidents. Hence, these systems are required to ensure the individual and societal risk criteria. In this paper, we reviewed EU risk criteria which is already operated in UK and Netherlands, then we proposed acceptable risk criteria and estimated risk of oil immersed transformer for subway with FN curve.

퍼지 알고리즘을 이용한 유중 변압기의 안전진단 및 평가에 관한 연구 (A Study on the Safty Diagnosis and Evaluation of Oil-immersed Transformer using fuzzy Algorithm)

  • 김영일
    • 전기학회논문지P
    • /
    • 제55권4호
    • /
    • pp.190-195
    • /
    • 2006
  • In this paper, safety algorithm of transformer is introduced for the sake of MV/LV distribution customers by using fuzzy theory. The current-carrying capacity of transformer is usually determined by the maximum temperature at which the transformer is permitted to operate. Overload of transformer has an effect on transformer utilization rate and maximum temperature rises as well as maximum ambient temperature of insulating materials. Therefore, we proposed the safety algorithm considering the overload of transformer and ambient temperature in this paper. We introduced the correlational equations between each parameters using experimental data of IEEE std C57.91-1995, and deduced the result using fuzzy reasoning. We guessed the safety algorithm making a diagnosis for the safety status of oil-immersed transformer.

전철 급전시스템의 22900/1200V 유입변압기 안전성 분석 (Safety Analysis and Safety Measures of 22900/1200V Oil Immersed Transformer at Power Supply System)

  • 이종수;이종우
    • 전기학회논문지
    • /
    • 제62권9호
    • /
    • pp.1335-1342
    • /
    • 2013
  • Subway is electrified railway system nowadays, in which liquid dielectric transformers have been widely used, though mold type transformers are replacing it. The transformers supplies large electric power and have innate hazards causing accidents under operation. A number of researcher have carried out on failures of it and have oriented to identify transformer's failure causes and how to maintain it healthy state. The transformer failures can cause serious accidents which can provoke economic loss and leads persons to kill. In this paper, we carried out a safety activity to reveal hazards and to estimate risk of subway liquid dielectric transformers using FMEA, HAZOP and What-if methods. In case of installing safety devices in oil immersed transformer, we tried to evaluate an effect on a subsystem's failure rate. We proposed how to design subsystem failure rate and safety device failure rates.