• 제목/요약/키워드: Oil mist filter

검색결과 10건 처리시간 0.011초

CFD모델링을 통한 오일 미스트필터효율 향상 결정요소에 관한 연구 (Determining Factors to Enhanced Oil Mist Filter Efficiency Using CFD Modeling)

  • 신희재
    • 한국기계가공학회지
    • /
    • 제20권10호
    • /
    • pp.119-127
    • /
    • 2021
  • Small drops in gas cause some problems for downstream equipments such as turbine, compressor and etc. In some cases, we are obliged to remove hazardous liquid mist from gas. In order to remove water or other liquids from the gas, there are some equipments like mesh mist eliminator and vane-plate mist eliminator. oil mist filter is a kind of liquid eliminator equipments used to remove the liquid with 1-10um droplet diameter from the gas. In this paper is determine the factors affecting the oil mist filter efficiency using CFD. length and angle of the filter were considered and the results and compare the results of the efficiency tests, showed error of less than 3%. optimum filter can remove more than 87.3% between 1 and 10um of oil mist.

블로바이 가스 내 오일입자들을 제거하기 위한 필터의 유동특성 수치해석 (Numerical Analysis of Flow Characteristics of the Filter for Separating Oil Mist from Blow-by Gas)

  • 윤정의;채강석;강혁진;정도영
    • 한국자동차공학회논문집
    • /
    • 제24권5호
    • /
    • pp.549-555
    • /
    • 2016
  • This research was performed to determine the oil separation characteristics of the specially designed oil filter installed in a PCV cylinder head passage. The oil filter was specially designed with fleece for separating oil mist from blow-by gas. The fleece, made of fiber fabric material, is placed in the oil filter case to absorb oil mist with a small pressure drop during blow-by gas through the filter. To do this, 3-D CFD analysis was simulated for the simplified PCV system with the oil filter using the commercial code, Ansys CFX. Results showed that the oil filter's efficiency with fleece sharply increased as oil droplet size increased.

원심력 필터 재생기능을 갖춘 오일 미스트 여과 집진장치 개발 (Development of an Oil Mist Collector Equipped with Centrifugal De-oiling System)

  • 김태형;서정윤;하현철;김종철;조진호
    • 한국산업보건학회지
    • /
    • 제15권3호
    • /
    • pp.166-175
    • /
    • 2005
  • Health effects associated with metal working fluid (MWF) exposures include dermatitis, respiratory disease, hypersensitive pneumonitis, and asthma. Frequently, occupational exposures to MWFs are controlled by ventilating an enclosure with an air cleaning unit that includes a fan preceded by various kinds of filtration. There are several kinds of air cleaning units used in machining centers. But the associated troubles have hindered from efficiently using these devices. The main problem is the relatively short period of filter replacement. The reason is that the air cleaning units usually do not have the de-oiling systems, thus leading the earlier clogging of filters and reducing the flow rate of hood. Thus, the first stage of study was conducted to overcome this problem by developing the new oil mist collector equipped with the easy de-oiling system. The principle of de-oiling is that the centrifugal force generated by spinning the drum covered by filter fabric separates oils from the filter fabric. It would be very similar to the spin-dry laundry. By adopting this de-oiling technique, the problems associated with the conventional oil mist collectors could be solved. Several tests/analyses were performed to make the lab-scale oil mist collector. The collection efficiencies and the de-oiling efficiencies of commercially available filter fabrics were tested. Subsequently, the endurance test were conducted by observing SEM photos of filter fabrics and measuring tensile strength/expansion coefficient after spinning the filter drum for 20 minutes at the different rotation speeds. By doing these experiments, the most appropriate filter fabric and rotation speed/duration were selected. Finally, the new oil mist collector was designed. In the near future, this device must be tested in the real machining center.

서브필터 형상에 따른 Oil-mist Filter의 포집효율 향상에 관한 연구 (A Study on the Collecting Efficiency of Oil-mist Filter according to the Sub-filter Shape)

  • 김용선;윤성민;신희재;고상철
    • 한국기계가공학회지
    • /
    • 제18권1호
    • /
    • pp.16-23
    • /
    • 2019
  • Cooking oil in kitchen-fog is the most harmful factor to the health of a cook. The proposed filter is a tool that protects the cooked state, to prevent users from inhaling oil mist in the kitchen. Due to efficiency issues, existing filters are of the mesh type or baffle type. In this paper, CFD analysis is carried out to select a filter with low pressure loss and low efficiency, and to attach the sub-filter to improve efficiency. The results of the analysis on the collection efficiency and pressure loss of three sub-filters, i.e., circle type, droplet type, and cone type, showed that the collection efficiency was 64.09% and the pressure loss was 1.26 mmAq when the circle type sub-filter was applied. The position of the sub-filter showed the best efficiency and pressure loss when it was located at the bottom of the center of the gap of the main filter.

코안다효과를 이용한 필터에 관한 연구 (A Study on Improving Filter Performance Using Coanda Effect)

  • 김용선;석재준;신희재;고상철
    • 한국기계가공학회지
    • /
    • 제19권3호
    • /
    • pp.99-104
    • /
    • 2020
  • Modern people spend a lot of time indoors. Oil mist has a very fatal effect on the cook's health. Range Hood's filter plays a very important role in removing oil mist from kitchen. In this study, we applied coanda effect to increase the collection efficiency of filter. Original, Bottom, Slide Three shapes were simulated, and the two shapes were measured and compared using a wind tunnel tester. Pressure loss is measured below 2.0mmAq for all three filters, making them easy to use indoors. The simulation results were 15% for the original filter, 22% for the bottom filter, and 30% for the slide filter. The wind tunnel tester obtained 26% of the original filter and 30% of the slide filter. Research is needed to increase the collection efficiency by 50%.

미세 분무유 제거를 위한 신개념 특수필터 설계 (New Design of Cap Type Filter for Oil Mist Removal)

  • 김홍건
    • 한국생산제조학회지
    • /
    • 제20권1호
    • /
    • pp.13-16
    • /
    • 2011
  • It is a tendency where the number of the restaurant is increasing recently with advancement of the food service industry. In comparison, Noxiousness fine MIST and the removal are passively done in about offensive odor which occurs meat products processing as emitting like that in the atmosphere. Because adherence lamination in the exhaustion line pipe has need of a periodic cleaning and change, it must discontinue the business of long time. In this paper, The technique development on fine MIST, dust of offensive odor and filtering which occur meat products processing prevents adherence/lamination of fine MIST in exhaustion line pipe. And the source prevents the environmental matter which is emitted in the atmosphere under maximizing boil offensive odor and the filtering effect of noxiousness MIST.

우리나라에서 사용하는 광물유의 유해특성과 관리대책에 관한 연구 - 공기중 MWF 미스트의 측정방법과 관리대책 - (Control and Investigation for Hazardous Characteristics of Metal Working Fluids Used in Korea - A Study on the Control and Sampling Method for Airborne MWF mist -)

  • 백남원;박동욱;윤충식;조숙자;김신범;임호섭
    • 한국산업보건학회지
    • /
    • 제7권2호
    • /
    • pp.171-180
    • /
    • 1997
  • The objectives of this study were both 10 discuss the sampling method for airborne metalworking fluids(MWF)' mist and 10 suggest measures to minimize worker's exposure to carcinogen contained in metalworking fluids. In order to measure airborne MWF mist, it seems to be appropriate to use NIOSH Method #0500(filler weight) rather than NIOSH Method # 5026(analysis by FTIR). Because MWF mist on PVC filter evaporated and migrated during sampling, worker's exposure to MWF could be underestimated. So, when evaluating worker's exposure to MWF mist, other environmental conditions also must be considered. Enclosure and local exhaust ventilation system seems to he the most effective measure and must be constructed with process facility. In order to control worker exposure to carcinogens contained in MWF, distillation type and condition for crude oil, PAH concentration in MWF, and viscosity index of MWF must legally be described.

  • PDF

PVC필터에 채취된 절삭유의 손실에 관한 연구 (Loss of Metalworking Fluids Collected on PVC Filter Due to Contact with Clean Air and Desiccation)

  • 박동욱;하권철
    • 분석과학
    • /
    • 제14권5호
    • /
    • pp.451-457
    • /
    • 2001
  • 절삭유(Metalworking Fludis, MWF) 노출로 인한 건강상의 장애는 암, 호흡기질환, 피부질환이다. MWF는 20여가지 이상의 화학물질이 혼합된 고분자의 화합물로서 상온에서 쉽게 증발되지 않는다. 이러한 특성으로 공기 중 MWF미스트의 측정과 분석은 PVC필터를 이용한 중량법이 국제적으로 공인되어 이용되고 있다. 그러나 사업장에서 MWF는 사용과정에서 분산되면 표면적이 커지고 증발하기 쉬운 상태로 된다. 본 연구는 실험실에서 MWF미스트 발생장치를 제작하여 MWF미스트가 필터에 채취되고 분석되는 과정에서 손실되는 양과 원인을 정량적으로 분석하였다. 즉 챔버에서 MWF가 채취된 PVC필터를 깨끗한 공기로 일정시간동안(10 ~ 240 분) 접촉하고 건조하여 각각의 과정(공기접촉, 건조기간)에서의 손실을 평가하였다. 공기와의 접촉 10분 후에 손실된 MWF양은 원래양의 12.4% - 21.8%였다. 전과정에서 손실된 양의 53.3%가 공기의 접촉초기에 일어나는 것을 확인하였다. PVC필터에 채취된 MWF의 손실은 건조과정에서 일어난 것을 확인하였다. PVC필터에 채취된 MWF의 손실에 영향을 미치는 요인을 분석하기 위한 다중회귀분석에서 MWF의 특성(사용중인 것과 사용하지 않는 것)이 유의한 예측변수였다. 이 연구 결과에 따르면, 국제적으로 공인된 증량법에 의한 공기중 MWF측정은 과소평가되는 것으로 판단된다.

  • PDF

방진마스크의 에어졸 방어효과와 밀착정도 (Protection against Aerosols by particulate Respirators and Fit Performance)

  • 한돈희
    • 한국환경보건학회지
    • /
    • 제27권2호
    • /
    • pp.30-36
    • /
    • 2001
  • This review begins with a brief expression of aerosol capture mechanism of fibrous filter(s) and performance of particulate removing respirators. The more complicated and detailed discussion is not included in this articles. Filtration efficiency and pressure drop are introduced as quality factor ( $q_{F}$) and the way in which filtration efficiency varies with particle size is discussed. Quality factors fro filters recently certified in USA were found to be very higher than those of filters made in Korea, China and USA filters certified with old certified standards. Electrically charged filters are widely used because they have high filtration efficiency and low pressure drop, but their efficiency decreases sharply at the condition occurring wet and oil mist. A discussion is given of respirator leakage through face seal and filter media with fit testing and total inward leakage testing. Since fit factor (FF) refers to the reciprocal of the fraction of the total air entering a respirator through face seal leakage , the degree of fitting performance for respirators is expected with FF. Because respirators made in Korea had generally lower FFs than respirators made in USA, it is necessary to develope respirators that fit properly for Koreans or establish regulations for fit testing.g.

  • PDF

혼합 냉매를 이용한 극저온 J-T 냉동기 관한 실험적 연구 (An Experimental Study of The J-T Cryocooler with Mixed Refrigerant)

  • 이경수;정상권
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제3권1호
    • /
    • pp.64-68
    • /
    • 2001
  • An experimental study on the Joule-Thomson cryocooler with the mixed refrigerant (MR) is described in this paper, J-T refrigeration experiment was performed with a single stage regular air-conditioning compressor The mixed refrigerant in the experiment was composed of 75% mol fraction of $N_2$. 30% moi fraction of CH$_4$. 30% moi fraction of $C_2$H$_{6}$. 10% mot fraction of $C_3$H$_{8}$ and 15% mot fraction of iso-C$_4$H$_{10}$. Oil mist in the MR stream could be eliminated completely by the glass microfiber filter. Since a single stage compressor that had been designed thor R22 is not appropriate for high Pressure ratio of the mixed refrigerant especially during the transient period. two modifications were incorporated to regular J-T refrigeration cycle. First. a Portion of the MR was by-passed at the inlet of the heat exchanger and transferred directly to 7he suction of the compressor in the modified system. Second, a buffer volume was Prepared to change the mass flow rate of refrigerant. The pressure ratio in J-T expansion device was relieved at the beginning of the operation due to the by-Pass scheme. but it gradually decreased during the transient Process as some of the MR component condensed at low temperature. The buffer volume at the suction side was used to increase the MR gas density in the system after the transient cool-down period. Form the experiment with the modified system, the refrigerator could reach the lowest temperature of -152$^{\circ}C$ without cooling load. and about -15$0^{\circ}C$ with 5 W of cooling load . . . .

  • PDF