• Title/Summary/Keyword: Oil collection rate

Search Result 22, Processing Time 0.034 seconds

Study on Performance Evaluation of Marine Kitchen Ventilation Hood (선박용 주방 환기후드의 성능평가에 관한 연구)

  • Kim, Dong-Gyu;Chung, Yong-Hyun;Kum, Jong-Soo
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.26 no.6
    • /
    • pp.1373-1379
    • /
    • 2014
  • The purpose of this research is to evaluate the performance of the Ventilation hood and to make better oil collection for improvement. In order to complete the purpose, the research range has limited a kitchen cooking utensil used in preparing food in vessels. Assessment was carried out with reference(ASTM F1704-09) to the specification. Evaluation items of ventilation hood were flow visualization, oil collection rate and noise levels. When filter angle was 40 degrees, oil collection rate was increased by 9%.

Performance Test of Vortex-Disc Skimmers (Vortex-Disc형 유회수기의 성능평가)

  • Yu J.S.
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.2 no.2
    • /
    • pp.95-102
    • /
    • 1999
  • Various types of oil response equipments and oil recovery vessels are being developed in Korea from the 1990s to respond nil spill accidents. It should be considered prior to the selection of the oil skimmers to make the oil recovery system more efficient at early stage of oil spill accidents. Rotating baldes of vortex skimmer beneath the water surface concentrate oil and draw it into the weir, where it flows to a collection sump. In this study a recently developed Vortex-Disc skimmer(model : VDS-50) is introduced and the performance test results for the skimmer are discussed.

  • PDF

An Experimental Investigation on Fire Characteristics of Light Oil & Methanol for Spilled Surface (경유와 메탄올의 유출표면에 따른 화재특성에 관한 실험적 고찰)

  • Lee, Jung-Yon;Jung, Ki-Chang;Kim, Hong
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.6
    • /
    • pp.103-108
    • /
    • 2010
  • In this study, tank truck incidents of road transport of hazardous materials to experimental investigated the potential fire hazard. Real scale fire was to perform experiments for on this qualitative and quantitative data collection and analysis. Particularly affected by radiant heat from the flames caused and damage estimates range investigated accordingly. Flame temperature, internal temperature of tank and emitted radiation from the flames was investigated. The flame of light oil spill caused a fire at a temperature of about $300^{\circ}C$ high in comparison with the methanol by combustion of diesel and methanol, according to the difference, the flame duration changes varies depending on the Burning rate, amount of radiant heat flux from light oil fire was 4 times increases compared with fire of methanol. Depending on spill locations(kinds of road surfaces, absorbing rate) and the longer the duration of the flame important factors for the internal temperature of tank truck rise was found. Dirt roads than paved road accident in a fire caused by leakage of hazardous was could the higher the damaged. Therefor, Fire suppression activities should be required in particular to be around.

Fire Characteristics for Spill Rate of Light oil and Methanol (경유와 메탄올의 유출속도에 따른 화재특성)

  • Lee, Jung Yun;Kim, Hong
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.5
    • /
    • pp.54-60
    • /
    • 2016
  • In this study, tank truck incidents of road transport of hazardous materials to experimental investigated the potential fire hazard. Real scale fire was to perform experiments for on this qualitative and quantitative data collection and analysis. Particularly affected by radiant heat from the flames caused and damage estimates range investigated accordingly. Flame temperature, internal temperature of tank and emitted radiation from the flames was investigated. The flame of light oil spill caused a fire at a temperature of about $300^{\circ}C$ high in comparison with the methanol by combustion of diesel and methanol, according to the difference, the flame duration changes varies depending on the Burning rate. Depending on spill rate(30, 60, 90 and $120{\ell}/min$) and the longer the duration of the flame important factors for the internal temperature of tank lorry rise was found. Road accident in a fire caused by leakage of hazardous was could the higher the damaged. Therefor, Fire suppression activities should be required in particular to be around.

A Study on Dust Collection Efficiency of Axial-vane Type Cyclone for Oil Mist (오일미스트용 축상 유입식 사이클론의 집진효율에 관한 연구)

  • Yi, Chung-Seob;Shin, Hae-Joong;Lee, Chi-Woo
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.3
    • /
    • pp.415-420
    • /
    • 2012
  • Dust collecting performance of axial-vane type cyclone for oil mist was analyzed in this study. For predicting cut diameter size of cyclone, the number and angle of vane (${\beta}_2{^{\prime}}$) was calculated by CFD. As the result, ${\beta}_2{^{\prime}}$ was decreased as the number of vane was increased and the angle of inclination (${\beta}_2{^{\prime}}$) decreased, and it cause strong swirl flow. Therefore, it could be confirmed that as the number of vane was increased and the angle of inclination was decreased, cut diameter size was decreased. Also, by verifying the results of CFD through experiment, the cut diameter size could be 2 ${\mu}m$ at 4 $m^3/min$ of flow rate.

The study on collection efficiency of two-stage electrostatic precipitator using non-metallic electrode for improve corrosion resistance and light weight (내부식성과 경량성 향상을 위한 비금속 재질 집진판의 2단 전기집진기 집진효율 연구)

  • An, So-Hee;Lee, Yeawan;Kim, Ye-Sle;Kim, Yong-Jin;Han, Bangwoo;Kim, Hak-Joon
    • Particle and aerosol research
    • /
    • v.17 no.2
    • /
    • pp.21-27
    • /
    • 2021
  • We developed non-metallic electrodes that can replace metallic electrodes of the electrostatic precipitator(ESP) for the purpose of light weight, corrosion resistance, cost reduction. We manufactured three types of collection electrodes made of stainless steel (M), Carbon ink coating layer-Plastic sheet-Carbon ink coating layer (CPC), and Plastic sheet-Carbon ink coating layer-Plastic sheet (PCP). We studied the collection efficiency of a two-stage ESP using oil mist particles with and without collection stage by changing the flow rate, the material of collection electrode, and the applied voltage of the pre-charger module and the collection module. Here we measured concentrations of particles at diameters of 0.45 ㎛ (CMD; count median diameter) and 3.0 ㎛ (MMD : mass median diameter), as well as PM2.5 and PM10. As a result of the experiment, two-stage ESP had 22~25% higher collection efficiency in PM2.5 than one-stage ESP at the same applied voltage. The difference in collection efficiency by varying the materials of collection electrodes was less than 5%. The weight of the non-metallic electrode was only one eighth the weight of the metal electrode. CPC electrode had a thickness of 0.27 mm, which was 1.5 times thinner than a thickness of PCP electrode, so when the flow rate increased, the CPC electrodes couldn't be kept at equal intervals due to the fluttering unlike PCP electrodes. In addition, the PCP-CPC collection module of the present experiment followed the theoretical efficiency based on Deutsch equation and Cochet's charging theory.

Development of an Oil Mist Collector Equipped with Centrifugal De-oiling System (원심력 필터 재생기능을 갖춘 오일 미스트 여과 집진장치 개발)

  • Kim, Tae-Hyeung;Seo, Jeoung-Yoon;Ha, Hyun-Chul;Kim, Jong-Cheul;Cho, Jin-Ho
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.3
    • /
    • pp.166-175
    • /
    • 2005
  • Health effects associated with metal working fluid (MWF) exposures include dermatitis, respiratory disease, hypersensitive pneumonitis, and asthma. Frequently, occupational exposures to MWFs are controlled by ventilating an enclosure with an air cleaning unit that includes a fan preceded by various kinds of filtration. There are several kinds of air cleaning units used in machining centers. But the associated troubles have hindered from efficiently using these devices. The main problem is the relatively short period of filter replacement. The reason is that the air cleaning units usually do not have the de-oiling systems, thus leading the earlier clogging of filters and reducing the flow rate of hood. Thus, the first stage of study was conducted to overcome this problem by developing the new oil mist collector equipped with the easy de-oiling system. The principle of de-oiling is that the centrifugal force generated by spinning the drum covered by filter fabric separates oils from the filter fabric. It would be very similar to the spin-dry laundry. By adopting this de-oiling technique, the problems associated with the conventional oil mist collectors could be solved. Several tests/analyses were performed to make the lab-scale oil mist collector. The collection efficiencies and the de-oiling efficiencies of commercially available filter fabrics were tested. Subsequently, the endurance test were conducted by observing SEM photos of filter fabrics and measuring tensile strength/expansion coefficient after spinning the filter drum for 20 minutes at the different rotation speeds. By doing these experiments, the most appropriate filter fabric and rotation speed/duration were selected. Finally, the new oil mist collector was designed. In the near future, this device must be tested in the real machining center.

Analysis of Behavior Characteristics of Water Pollutants in Yeongsan River Using 3D Hydraulic Model (3차원 수리 모델을 이용한 영산강 수질오염물질의 수체 내 거동 특성 분석)

  • Hye Yeon Oh;Eun Jung Kim;Jung Hyun Choi
    • Journal of Korean Society on Water Environment
    • /
    • v.39 no.6
    • /
    • pp.439-450
    • /
    • 2023
  • The Yeongsan River, a major water resource for Jeollanam-do, that is adjacent to industrial complexes and agricultural areas, is exposed to water pollution. Therefore, it is necessary to investigate the impact of water pollution incidences and prepare response systems for river environment safety for other water resources in the future. Environmental Fluid Dynamics Code (EFDC) was applied to the mainstream of the Yeongsan River where residential, commercial, and agricultural areas are located to analyze the behavior of pollutants conducting the scenario analysis. Considering the pollutants that affected the study area, two pollutants, oil and benzene, with different physical and chemical characteristics were selected for the analysis. As a result of comparing the actual and simulated values of the water elevation, temperature, and flow rate, it was confirmed that the model adequately reproduced the hydraulic characteristics of the Yeongsan River. The oil flow dynamics showed that an increase in flow rate led to reduction in the maximum height of the slick. Notably, the behavior of the oil was predominantly influenced by the wind conditions. In the case of benzene, lower flow scenarios exhibited decreased arrival times and residence times accompanied by an elevation in the maximum concentration levels. From the results of pollutant behavior in the study area, it is feasible to utilize the section of tributary confluence for collection and the weir area for dilution. This study enhances the understanding of the pollutant's behavior with different characteristics and develops effective control systems tailored to the physicochemical attributes of pollutants.

Release Behavior and Characterization of PCL Microcapsules Containing Lemongrass Oil (레몬그라스 오일을 함유하는 PCL마이크로캡슐의 특성과 방출거동)

  • Park, Jong-Kwon;Kim, Ji-Eun;Jeong, Noh-Hee
    • Applied Chemistry for Engineering
    • /
    • v.26 no.3
    • /
    • pp.341-346
    • /
    • 2015
  • In this study, poly ${\varepsilon}$-caprolactone(PCL) microcapsules containing lemongrass oil was prepared by the solvent evaporation method. Effects of concentrations of PCL and poly vinyl alcohol (PVA) as well as stirring speeds when preparing microcapsules were investigated. Specific peaks of lemongrass oil in PCL microcapsules at 1600 and $2900cm^{-1}$ were observed by FT-IR. The particle size and shape of microcapsules were also measured by polarizing microscope and optical microscopy. The average particle size of microcapsules decreased with increasing the stirring rate. At the stirring speed of 1500 rpm, and 1 wt% of each PCL and PVA concentrations, the smallest particles were formed. Collection efficiencies of lemongrass oil of 77.5% and 69.5% were obtained when 1.5 wt% of PCL and 2 wt% of PVA were used, respectively. In addition, the release behavior and antioxidant activity of lemongrass oil from PCL microcapsules were examined using UV-Vis spectrophotometry. When 0.5 wt% PCL and 2.0 wt% PVA were used with the slow stirring rate, microcapsules showed a fast release rate. The characteristics of antioxidant activity exhibited similar to that of the release behavior.

The Regulatory Framework of Taiwan′s Municipal Waste Recycling

  • Lee, Shou-Chien
    • Proceedings of the IEEK Conference
    • /
    • 2001.10a
    • /
    • pp.19-23
    • /
    • 2001
  • In addition to landfilling and incineration, waste minimization and recycling have become priorities in Taiwan's municipal waste management strategies over the past 10 years. Major recycling initiatives being implemented in Taiwan include producer responsibility, "pay-as-you-throw, " and mandatory sorting provisions. Currently, the producer responsibility regime established under the Waste Disposal Act and administered by the Environmental Protection Administration (EPA) requires that manufacturers or importers of listed items, including containers, batteries. cars, motorcycles ("scooters"), tires, oil, televisions, refrigerators, air conditioners, washing machines, computers, and printers, pay recycling fees to government recycling funds. EPA then uses the recycling funds to subsidize collection and recycling. The 2001 recycling fund budget totals NT$57 billion (NT$35 = US$l). Under the producer responsibility regime, EPA-designated retailers ("sellers") must accept end-of-life items returned to them by the consumers. At the local level, Taipei City implements a pay-as-you-throw program, whereby citizens pay waste collection and treatment fees through the purchase of special trash bags approved by the Taipei City Government. However. recyclables that are separated by citizens are collected free-of-charge by the City. Taichung City and Kaohsiung City, on the other hand, enforce mandatory sorting schemes, whereby citizens face penalties if they don't separate recyclables from the trash before pick-up. These programs have resulted in a significant reduction in municipal waste. Per capita waste collected per day has dropped from 1.143 kg in 1997 to 0.978 kg in 2000. Targeting a 10% recycling rate for municipal waste in 2001. EPA plans to research and develop new recycling techniques, expand the scope of producer responsibilities, and strengthen existing municipal recyclable collection programs. To this end, among other initiatives, EPA has prepared a draft "Resource Recycling and Reuse Act" that would complement the existing producer responsibility programs by incorporating into the current recycling framework the concept of product life-cycle management.

  • PDF