• 제목/요약/키워드: Odor emission

검색결과 136건 처리시간 0.022초

매립지 메탄 및 악취 배출 저감을 위한 바이오커버 및 바이오필터의 현장적용 평가 연구 (Evaluation of field application of biocover and biofilter to reduce landfill methane and odor emissions)

  • 채정석;전준민;오경철;류희욱;조경숙;김신도
    • 실내환경 및 냄새 학회지
    • /
    • 제16권2호
    • /
    • pp.139-149
    • /
    • 2017
  • In order to reduce odor and methane emission from the landfill, open biocovers and a closed biofilter were applied to the landfill site. Three biocovers and the biofilter are suitable for relatively small-sized landfills with facilities that cannot resource methane into recovery due to small volumes of methane emission. Biocover-1 consists only of the soil of the landfill site while biocover-2 is mixed with the earthworm casts and artificial soil (perlite). The biofilter formed a bio-layer by adding mixed food waste compost as packing material of biocover-2. The removal efficiency decreased over time on biocover-1. However, biocover-2 and the biofilter showed stable odor removal efficiency. The rates of methane removal efficiency were in order of biofilter (94.9%)>, biocover-1(42.3%)>, and biocover-2 (37.0%). The methane removal efficiency over time in biocover-1 was gradually decreased. However, drastic efficiency decline was observed in biocover-2 due to the hardening process. As a result of overturning the surface soil where the hardening process was observed, methane removal efficiency increased again. The biofilter showed stable methane removal efficiency without degradation. The estimate methane oxidation rate in biocover-1 was an average of 10.4%. Biocover-2 showed an efficiency of 46.3% after 25 days of forming biocover. However, due to hardening process efficiency dropped to 4.6%. After overturn of the surface soil, the rate subsequently increased to 17.9%, with an evaluated average of 12.5%.

축산시설의 축종별 악취물질 농도 특성과 악취도 평가 (Assessment of Odor Characterization and Odor Unit from Livestock Facilities by animals)

  • 장영기;정봉진;김정;송기봉;김호정;유용희
    • 환경영향평가
    • /
    • 제19권1호
    • /
    • pp.29-38
    • /
    • 2010
  • At recent the number of livestock is increased and the size of farm has changed to large facilities in Korea. So the livestock facilities have become one of major sources of odor emission. The purpose of this study is to analyze the concentration and assessment of odor unit from livestock facilities for cow, dairy, swine and poultry. The eleven odor pollutants such as $H_2S$, ($CH_3$)SH, $(CH_3)_2S$, $(CH_3)_2S_2$, $CH_3N$, $NH_3$, $(CH_3)_2N$, $(CH_3)_3N$, butyric acid, valeric acid and isovaleric acid, measured for assessment of the odor concentrations from livestock facility. As the results, it is found that the major matters of odor from livestock facilities were $NH_3$ and $H_2S$. The highest concentration of $NH_3$ is measured as 15 ppm at henhouse and $H_2S$ is measured as 858 ppb at penpig facilities. In the comparison of the average odor unit from livestocks, it is found that the highest odor unit was from swine and the lowest odor unit was from cow facility. So odor unit from swine facilities was 12 to 30 times higher than the odor unit from cow facilities.

Development of an Odor Abatement System for Swine Manure Treatment Facilities

  • Lee, S.H.;Yun, N.K.;Kim, G.W.;Yum, S.H.;Cho, Y.H.
    • 한국축산시설환경학회지
    • /
    • 제14권1호
    • /
    • pp.1-8
    • /
    • 2008
  • This study was conducted to solve the problem of public grievance owing to odor of a pig farm. Odor emissions from pig production systems mainly originate from liquid manure storage and solid manure fermentation. The low-cost odor abatement system (OAS) for application at liquid manure storage tank and solid manure fermentation facilities was developed in this study. The OAS adapted odor removing principles of a biofilter and biotrickling filter. The OAS is very simplified in structure. The appearance of the OAS had a form of cylindrical or cubical shape. The system performance was monitored for about one year after stabilization. A 7 seconds empty bed contact time for the OAS was adapted to achieve the odor reduction levels. The commercial type of OAS was constructed with media comprised of wood chips. Moisture content always remained above 50% wet basis. Average ammonia removal efficiency for the developed design was 89% at the liquid manure storage tank. Also, the removal efficiency at a solid manure fermentation facility was 86% on ammonia.

  • PDF

익산지역에서 직접관능법에 의한 악취관리 사례 연구 (Application case of odor management applied direct olfactory method in Iksan)

  • 김화옥;박희근;신대윤;강공언
    • 환경위생공학
    • /
    • 제24권2호
    • /
    • pp.17-30
    • /
    • 2009
  • In Iksan city, there have been a lot of complaints caused by offensive odor from residents living near the public environmental infrastructures and the Iksan industrial complex. To solve these problems, it is important to know the present condition of odor pollution level in these areas, the emission characteristics of malodorous gases in temporal and spatial variations in addition to meteorological components, and the facilities of major sources emitting malodorous compounds. The objectives of this study is to make the odor monitoring network for 20 people who lived and worked in areas where the environmental infrastructures and the Iksan industrial complex are located and their neighboring areas for six months from June 1st to October 31st in 2008 in Iksan and to monitor the temporal and regional frequency and characteristics of odor intensity using direct olfactory methods. As a result of odor monitoring, the highest frequency of sensed odor per month and 20 people for six months was found to be 107 in July, followed by 84 in September, 80 in August, 54 in June, 38 in October, respectively. Odor intensity trend showed a regional trend in the decreasing order of Dongsan-dong, Busong-dong, and Palbong-dong. Odor was widely perceived from night through next morning and considered as the sense of excreta, chemicals, sewage, compost, waste, etc. When high odor intensity was sensed, there were constant meteorological characteristics: relative humidity was 80~90%, wind speed was less than 0.5~1 m/sec, and main wind directions were from the east, the southeast, and the south.

Los Angeles와 San Francisco의 악취 저감 시스템을 통해 본 우리나라 하수도의 악취 저감 방안 (The measures to reduce sewer odor in South Korea through sewer odor reduction system in Los Angeles and San Francisco)

  • 지현욱;유성수
    • 상하수도학회지
    • /
    • 제32권5호
    • /
    • pp.445-451
    • /
    • 2018
  • Urban sanitary sewer systems can aid in preventing inundation, and can improve civil health by effectively disposing stormwater and wastewater. However, since sewage odor can cause adverse effects, numerous technical and administrative studies have been conducted for reducing such odor. European countries and the United States of America (USA) built modern sewer systems in the late 19th century, and have since been endeavoring to eliminate sewage odors. Several cities of the USA, such as Los Angeles (LA) that has a separate sewer system and San Francisco (SF) that has a combined sewer system, have produced and distributed odor control master plan manuals. Features common in the odor reduction plans of both these cities are that the odor reduction programs are operated in all the respective local regions and are supported by administrative systems. The primary aspectual difference between the two said programs is that the city of LA employs a sewage air purification system, whereas the city of SF controls the emission of major odor causing compounds. Compared to the existing sewer odor reduction systems of these two cities, South Korea is still in the initial phase of development. Through technical studies and policy implementations for sewer odor reduction, a foundation can be laid for improving the civil health quality.

국내 화학물질 배출량 특성에 관한 연구: 악취물질 중심으로 (A Study on the Emission Characteristics of Odorous Substances in Korea)

  • 임지영;전다영;김보경;류지성;윤대식;이청수
    • 한국환경보건학회지
    • /
    • 제45권5호
    • /
    • pp.465-473
    • /
    • 2019
  • Objectives: A variety of industries handling hazardous chemicals emit odorous substances. Based on the emission characteristics of major odor substances from the results of hazardous chemical substance emissions, we will define basic data for improving the management methods of odorous substances. Methods: A survey of hazardous pollutant emissions for 2010-2016 was conducted through the Pollutant Release and Transfer Register homepage. Eight kinds of designated odor substances (ammonia, hydrogen sulfide, dimethyl disulfide, acetaldehyde, styrene, toluene, xylene, methyl ethyl ketone) provided the study subjects. The status of chemical accidents for the target substances was analyzed using the Chemistry Safety Clearing-house system. Results: From 2010 to 2016, it was found that more than 30% of businesses that emitted odorous substances accounted for more than 50% of the total emissions of the eight substances. Emissions of xylene, toluene, methyl ethyl ketone, and ammonia were found, in that order, and they made up more than 90% of the total emitted. By region, about 70% of odorous substances were emitted in the top-four regions: Gyeongsangnam-do Province, Ulsan, Gyeonggi-do Province, and Jeollanam-do Province. Conclusion: Recently, the amount of chemical emissions has been continuously increasing, including those that can cause odor. Odorous substances can be a serious risk to the lives of local residents. Systematic research is needed for the health protection of residents.

적환장에서 발생하는 악취 분포 특성에 관한 연구 (A Study on Emission Characteristics of Odor Compounds from Waste Transfer Station)

  • 전재식;김은숙;유승성;오석률;최한영
    • 한국환경보건학회지
    • /
    • 제39권5호
    • /
    • pp.418-425
    • /
    • 2013
  • Objective: This study was carried out for the purpose of identifying major substances contributing to the production of odor and evaluating the characteristic of odors. Methods: Complex odor and 17 odorous compounds were measured at 18 waste transfer stations located in Seoul. Results: The dilution ratio value of complex odor ranged from 4 to 30 times in the boundary layer of 18 waste transfer stations. At 6 measurement points among the 18 waste transfer stations, the dilution ratio values exceeded standards (15 times). When the results were evaluated in terms of their contribution to the formation of malodor, the patterns indicated that the highest concentration values in the residential waste disposal process were of i-valeraldehyde and acetaldehyde, while butyraldehyde and acetaldehyde accounted for a large proportion of odorous compounds from the waste recycling process. Conclusions: It was found that butyraldehyde and acetaldehyde were the primary compounds released from the food waste disposal process. Overall, aldehyde compounds were the greatest contributor to detectable odor intensity emitted at the waste transfer stations.

대구시 서구 산업단지 주변 지역의 악취오염도와 악취감시시스템 운영 평가 (Evaluation of the Odor around an Industrial Complex Area and the Operational Effects of the Odor Monitoring System in Seo-gu, Daegu City)

  • 이명숙;금종록;강동훈;조항욱;권병윤;김은덕;이찬형;송희봉;신상희
    • 한국환경보건학회지
    • /
    • 제47권1호
    • /
    • pp.45-54
    • /
    • 2021
  • Objectives: This study evaluated the odor around an industrial complex area (#1-#5) and the operational effects of the Odor Monitoring System in Seo-gu in Daegu City. Methods: Samples were collected from November 2012 to December 2018 and were analyzed for complex odor. The odor occurrence rate and the odor reduction rate were calculated. Results: In 2018, the mean concentration of complex odor decreased 20.9% and the odor occurrence rate decreased from 65.0 to 27.5% around the industrial complex area (#1-#5) in Seo-gu compared to 2013. After the operation of the Odor Monitoring System, the standard excess rate (3.0%→40.8%) and the excess concentration of complex odor (1,442→4,304) increased at odor-emitting workplaces. In addition, the mean concentration of complex odor (15.9%) and the odor occurrence rate (60.6%→32.9%) around the industrial complex area (#1-#5) and the number of odor complaints (23.4%) in Seo-gu decreased. Conclusion: In order to reduce the odor around the industrial complex area, it is important to improve the odor emitting facilities. The Odor Monitoring System uses scientific and systematic monitoring methods that can help control and manage the odor emission facilities.

효소복합체가 양돈슬러리 및 돈사 악취발생에 미치는 영향 (Effects of Enzyme Complex on Odor Emission from Swine Slurry and Swine Buildings)

  • 정기한;한정철;곽석준;정재두;이진우;김두환
    • 한국축산시설환경학회지
    • /
    • 제14권1호
    • /
    • pp.15-22
    • /
    • 2008
  • 본 연구는 효소복합체 처리가 양돈분뇨의 액비화 과정의 악취제어 가능성을 조사하기 위하여 액비저장 탱크에 4주간 저장하면서 효소복합체 처리, 폭기 처리, 효소와 폭기 동시 처리 및 대조구로 나누어 비교하였다. 또한 효소복합체를 돈사에 살포하여 돈사내 공기의 질과 양돈장 부지경계선에서의 복합악취농도를 조사하였는데, 그 결과를 요약하면 다음과 같다. 효소복합체와 폭기 처리는 양돈분뇨의 액비화 과정의 암모니아와 황화수소 농도에 영향을 미치는 것으로 조사되었으며, 암모니아와 황화수소 농도는 4주간의 액비화 과정 동안 지속적으로 감소되었다. 효소복합체의 일정 수준 처리는 양돈분뇨 액비화 과정의 악취저감을 위한 효율적인 수단이 될 수 있을 것으로 판단된다. 효소복합체와 폭기 처리는 양돈분뇨의 액비화 과정의 총질소, 총인 및 암모니아성 질소 농도에 영향을 미치는 것으로 조사되었으며, 효소복합체 처리는 양돈분뇨 액비의 품질 유지와 악취저감을 위한 하나의 기술적 대안으로 충분한 것으로 보인다. 효소복합체 살포는 돈사내 공기의 질을 개선하고 양돈장의 부지경계선에서의 복합악취 저감에도 효과적으로 작용하는 것으로 나타났다. 이상의 결과를 요약하면, 효소복합체 처리는 양돈분뇨 액비화 과정의 악취제어와 고품질 액비제조 가능성이 인정되며, 돈사 내부 및 양돈장 환경개선과 악취저감 효과가 있는 것으로 판단된다.

  • PDF

2003년부터 2015년까지 CA 인증 공기청정기의 성능 시험 결과 분석 (Analysis of performance test results of CA-certified air cleaners from 2003 to 2015)

  • 김학준;홍기정;우창규;한방우;김용진
    • 한국입자에어로졸학회지
    • /
    • 제13권1호
    • /
    • pp.17-23
    • /
    • 2017
  • In this study, the test results obtained from the performance tests for CA (Korea Association of Cleaning Air) certificated air cleaners which had been commercially available in Korea from 2003 to 2015 were analyzed. Among the test parameters such as flow rate, particle collection efficiency, clean air delivery rate (CADR), ozone emission, odor removal efficiency and noise level, noise level and CADR were correlated with flow rates. Collection and odor removal efficiencies were 20% higher than the limit of the CA certification. The ozone emissions from the air cleaners were negligible because all the air cleaners were equipped with only HEPA filters, not electrostatic precipitation method which produces ozone.