• Title/Summary/Keyword: Odor Emission

Search Result 136, Processing Time 0.036 seconds

Charaterization of Odor from Cement Kiln (시멘트공장 소성로 악취 배출특성)

  • Kim, Ji-Hyun;Lim, Hee-Ah;Park, Young-Koo
    • Journal of the Korean Applied Science and Technology
    • /
    • v.34 no.3
    • /
    • pp.694-703
    • /
    • 2017
  • Many residents living near the cement factories are facing unpleasant odors. Thus, various efforts have been attempted to reduce the emission of odorous compounds from the cement manufacturing processes. This study focused on analysis of Acetaldehyde and their dispersion in vicinity of the residential area using theoretical calculation such as numerical simulation and dispersion model. The most significant odor species was acetaldehyde indicating 2 ppb at the test point, and the estimated concentration was similar to the value by Calpuff calculation. The modelling work revealed the emission source of the factory to influence the test site.

Analysis of formaldehyde using DNPH cartridge/LC-MS in the Ban-Woll.Shi-Hwa Industrial Complex (DNPH cartridge/LC-MS 방법에 의한 반월.시화산업단지의 폼알데하이드 분석에 관한 연구)

  • Cho Deok-Hee;Song Il-Seok;Kim In-Gu;Kim Woong-Soo;Kim Jong-Bo;Kim Tae-Hyun;Hwang Sun-Min;Nam Woo-Kyong
    • Journal of environmental and Sanitary engineering
    • /
    • v.21 no.1 s.59
    • /
    • pp.35-43
    • /
    • 2006
  • Formaldehyde is important because of their irritant and toxic properties, mutagenicity and carcinogenicity. In this study, liquid chromatography-mass spectrometry (LC-MS) is used for the analysis of formaldehyde after derivatization with 2,4-dinitrophenylhydrazine (DNPH) cartridge. Analytical parameters such as linearity, repeatability and minimum detection limit were evaluated. The linearity ($r^2$) was 0.9997 when analyte concentration ranges from 25 to $200{\mu}g/l$. The relative standard deviation (%RSD) was 1.25 % for concentration of $200{\mu}g/l$. The minimum detection limit (MDL) was 0.73 ppbv. It was shown that LC-MS method has a great potential for formaldehyde analysis. The results of formaldehyde from the survey of Ban-Woll and Shi-Hwa Industrial Complex samples, the highest level was 6.20, 3.93 ppb, respectively. The highest emission level of formaldehyde at chemical plants in the Ban-Woll' Shi-Hwa Industrial Complex was 5421.25 ppb.

PRELIMINARY STUDY ON COMPOSTING OF THE CATTLE MANURE AND RICE HULLS MIXTURES BY NEGATIVE AERATION

  • Park, K. J.;J. H. Hong;Park, M. H.;Park, W. C.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2000.11c
    • /
    • pp.777-783
    • /
    • 2000
  • Composting by negative aeration is a reasonable proposition to control odor generated during composting process. Cattle manure and rice hulls mixtures were composted in a bin composting system by negative aeration. Continuous(CA) and intermittent(IA) aeration methods were applied to analyze the composting characteristics. The composting temperature and the ammonia emission during composting were investigated according to the aeration methods. The main problem for the negative aeration was the generation of condensate in the suction line of blower. The quantity of condensate was significant for continuous aeration. The aeration method should be modified to escape from the cooling effect of continuous aeration at the initial stage of composting. It took a longer time to finish a composting for intermittent aeration on account of lower aeration. It was concluded that the composting by negative aeration could be accomplished by either continuous or intermittent aeration method if the flow rate would be controlled more efficiently and the water vapor in suction line of blower could be removed effectively. Ammonia emission increased up to maximum value of 675ppm for continuous aeration while 300ppm for intermittent aeration. However, the cumulative value of ammonia emission was larger for intermittent aeration than for continuous aeration.

  • PDF

Performance of a Biofilter for Odor Removal during Manure Composting

  • Park, K.J.;Hong, J.H.;Choi, M.H.
    • Agricultural and Biosystems Engineering
    • /
    • v.3 no.2
    • /
    • pp.59-64
    • /
    • 2002
  • Odor generated during composting of livestock manure is mainly due to ammonia emission. Biofiltration is a desirable method to control composting odor. This study was conducted to analyze the efficiency of using fresh compost as a biofilter. A mixture of cattle manure and recycled compost was composted in a bin equipped with a suction-type blower. The exhaust gas was filtered through the fresh compost. Residence time was controlled by the flow rate of exhaust gas and the depth of filtering materials. At the aeration rate of 30 L/min(experiment I), ammonia reduction rate varied from 100% to -15% for biofilter A(residence time 56.5 s) and almost 100% for biofilter B(residence time 113 s). At the aeration rate of 30 L/min, the cumulative ammonia reduction rate was 80.5% for biofilter A and 99.9% for biofilter B. At the aeration rate of 50 L/min(experiment II), the lowest reduction rate showed a negative value of -350% on the 8th and 9th day for biofilter A(residence time 33.9 5), and 50% on the loth day for biofilter B(residence time 67.8s). At the aeration rate of 50 L/min, the cumulative ammonia reduction rate was 82.5% fur biofilter A and 97.4% for biofilter B. Filtering efficiency was influenced by residence time. The moisture content(MC) and total nitrogen(T-N) of the filtering material were increased by absorbing moisture and ammonia included in the exhaust gas, while pH was decreased and total carbon(T-C) remained unchanged during the filtering operation.

  • PDF

A preliminary evaluation on mixed probiotics as an antimicrobial spraying agent in growing pig barn

  • Shanmugam, Sureshkumar;Jae Hong, Park;In Ho, Kim
    • Journal of Animal Science and Technology
    • /
    • v.64 no.6
    • /
    • pp.1035-1045
    • /
    • 2022
  • The purpose of this study is to examine whether spraying an anti-microbial agent into the slurry pit will reduce the noxious odor substances from piggery barns. For this, a total of 200 crossbred ([Landrace × Yorkshire] × Duroc) growing pigs with an initial average body weight (BW) of 23.58 ± 1.47 kg were selected and housed in two different rooms, i.e. control (CON) and treatment (TRT). Each room has 100 pigs (60 gilts and 40 borrows). For a period of 42 days, all pigs were fed with corn-soybean meal-based basal diet. Later the noxious odor substances were measured by the following methods. First, fecal samples were randomly collected and stored in sealed and unsealed containers, and sprayed with the non-anti-microbial agent (NAMA) (saline water) and multi-bacterial spraying (MBS) agent (200 :1, mixing ratio-fecal sample : probiotic), Second, the slurry pit of CON and TRT rooms were directly sprayed with NAMA and MBS, respectively. The fecal sample that was stored in sealed and un-sealed containers and sprayed with MBS significantly reduced NH3 and CO2 concentration at the end of day 7. However, at the end of day 42, the fecal sample showed a lower H2S, methyl mercaptans, acetic acid, and CO2 concentration compared to the unsealed container. Moreover, at the end of days 7, 14, 21, 28, 35, and 42 compared to the CON room and TRT room slurry pit emits lower concentrations of NH3, acetic acid, H2S, and methyl mercaptans, and CO2 into the atmosphere. Based on the current findings, we infer that spraying anti-microbial agents on pig dung would be one of the better approaches to suppress the odor emission from the barn in the future.

Seasonal concentrations and emission characteristics of odorous compounds produced from swine facilities in Jeju Island (제주지역 양돈시설에서 발생하는 악취물질의 계절별 농도 및 배출 특성)

  • Song, Jung-Min;Yang, Hyo-Sun;Ko, Han-Jong;Kim, Young Ju;Kim, Ki Youn;Kang, Chang-Hee
    • Analytical Science and Technology
    • /
    • v.26 no.6
    • /
    • pp.364-374
    • /
    • 2013
  • The major ten odorous compounds have been analyzed from four swine facilities in Jeju Island, in order to investigate the emission characteristics and odor contribution by different ventilation systems and manure treating types. From the study, the concentrations of $NH_3$ and TMA were high at the enclosed ventilation and scraper type facilities in winter season, and the sulfur compounds ($H_2S$, $CH_3SH$, DMS, DMDS) as well as volatile fatty acids (PA, n-BA, n-VA, iso-VA) showed high concentrations at the enclosed ventilation type facilities during winter season. The concentrations of nitrogen and sulfur compounds were high at slurry manure treat facilities. However, the volatile fatty acids (VFA) were relatively high in the scraper type swine facilities. The odor quotients of n-BA were high at four swine facilities, therefore the volatile fatty might be considered as the major odor causing compounds. Moreover the sum of odor quotient (SOQ) was high at the enclosed ventilation and scraper type facilities, and the odor contributions by volatile fatty acids were high in all swine facilities.