• Title/Summary/Keyword: Ocular lens

Search Result 98, Processing Time 0.031 seconds

A study of the manual procedure of ocular prosthesis (의안의 제조 방법에 관한 연구)

  • Kim, Jai Min;Park, Dong Hwa;Yoo, Geun Chang;Kim, Soon Ae;Cho, Seung Kwon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.2
    • /
    • pp.95-99
    • /
    • 2002
  • To investigate the manual procedure for custom fitting of ocular prosthesis and the cytotoxicity induced by extract solution of prosthetic eye, this study was performed. These procedures included the trial fitting of the wax model, impression molding, the an of iris color duplication, sclera mold made from the prosthetic wax model, scleral tints and vascular pattern, finishing and polishing. Inhibition of cell growth for extract solution was measured by MTT assay. Extract solution did not show the cytotoxicity. This study suggests that the manual procedure for custom fitting of ocular prosthesis is good for education of students.

  • PDF

The Characteristics of Diamond-like Carbon Films Deposited by Low Frequency(60Hz) Plasma CVD at Room Temperature for Optical lens (광학렌즈를 위한 저주파(60Hz) 플라즈마 CVD로 실온에서 제작한 다이아몬드성 탄소 박막의 특성)

  • Kang, Sung Soo;Lee, Won Jin;Sung, Duk Yong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.1 no.1
    • /
    • pp.23-28
    • /
    • 1996
  • Hydrogenated amorphous carbon films were fabricated by low frequency(60Hz) Plasma enhanced Chemical vapor deposition(LF-PECVD) at room temperature. The LF_PECVD has a couple of advantages as follows: cheap, and the employment of low power density makes the damage of samples small. The a-C:H films deposited in this work were highly transparent(99%), highly resistance(109-1011${\Omega}$-cm), and very uniform. The samples were deposited by the decomposition of CH4 and H2 mixing gas in the pressure rate range of 1% to 30%. The deposition rates, optical gap, and hydrogen contents are increased with CH4 contents.

  • PDF

EYE IRRITATION TEST OF LENS WASHING AGENTS CLlWELLTM ON NEW ZEALAND WHITE RABBITS (렌즈 보존액 CLlWELLTM에 대한 안점막자극성시험)

  • Jang, Woo-Yeong;Lee, Jeong-Yeong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.2
    • /
    • pp.67-78
    • /
    • 2007
  • The eye irritant test of lens washing agent, CLIWELL$^{TM}$ was conducted using Draize methods according to KFDA Guidelines. In addition, to test the potential toxicity of test articles, the ratio of inflammatory cells and non-inflammatory epitheloid cells was also observed using smear cytology methods against ocular discharge. At sacrifice, the histopathological changes on Cornea, Iris, Retina and Sclera were also observed in all animals. Slight irritancy of cornea and conjunctiva was observed at 1, 2 and 3 days after dropping in non-washing group. The MIOI of these points are detected as 4.50, 1.67 and 0.67, respectively. In washing group, slight irritancy of cornea and conjunctiva were observed at 1 and 2 days after dropping with MIOI as 0.67, respectively. Therefore, CLIWELL$^{TM}$ was considered as non-irritating materials because the MIOI is detected below 5.00 throughout the whole experimental periods in both washing and non-washing groups and the IAOI was also detected as 4.50. Except for significant increase of the inflammatory cell ratios in ocular discharge at 1 day after dropping of non-washing group compared to that non-treated intact eyes, no meaningful changes on smear cytology of ocular discharges are observed in this study. In addition, no abnormal histopathological changes on the cornea, iris, retina and sclera were also detected in CLIWELL$^{TM}$ dropping group compared to that of non-treated intact eyes.

  • PDF

The State and Problem of the Soft Contact Lens Wearer (소프트 콘택트렌즈 착용자의 실태와 문제점)

  • Kim, Douk-Hoon;Hwang, Sun-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.3 no.1
    • /
    • pp.249-258
    • /
    • 1998
  • This study was researched the state and problem of the soft contact Lens wear by the history and inverted microscopy. The results was as follows; 1. The first use of contact lens wear was the 15 years and the last use was the 26 years. The first age of most contact lens wear was the 19 years. 2. In the almost contact lens wearers, the first visual test was the optical shop. 3. At present, almost soft contact lens purchase the optical shop 4. At present, most contact lens wearer like a soft type. 5. At present, most soft contact lens were a domestic production, and some subjects were foreign country production, but some subjects were unknown. 6. After contact lens wear, most subjects don't known the corrected visual acuity, especially, almost people don't known the binocular visual acuity. 7. At present, on soft contact lens color, the teens like the non-color contact lens, twenties like the color contact lens, but thirties was not known. 8. On the advantage of soft contact lens knowledge, most teens and twenties were only one, thirties was unknown. 9. On the disadvantage of soft contact lens knowledge, most teens and thirties were only one, twenties were two. 10. On the side effect of soft contact lens wearer, teens was one, and twenties and thirties don't known. 11. On the main symptoms of soft contact lens wearer, total kinds were seven, On these kinds, most subjects were not symptoms, the next order was unknown on the symptom. But, On the symptoms, the main symptoms was the pain and dry eye. 12. At present, the research on the surface morphology of soft contact lens by inverted microscope, the lens repture, lens folding, foreign body immersion and etc were present. Above the study, most contact lens was soft lens, and the purchase was the optical shop, on the other hand, the knowledge of soft contact lens and visual acuity was few. As a results, On the practical problems of soft contact lens wear, the optician have to the soft contact lens treatment and aftercare by law and educational supporting.

  • PDF

A Clinical Study of Ocular Dimention and Visual Acuity Before and After Cataract Surgery Over Ninety Years Old (90세 이상 초고령 환자들의 백내장 수술전.후 안수치와 시력에 관한 임상연구)

  • Lee, Jung-Mi;Kim, In-Suk;Shin, Jin-Ah
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.275-280
    • /
    • 2010
  • Propose: Due to the rapid growth of medical technologies and the increasing population of older people, we investigated clinical status of ocular dimensions and visual acuity for pre and post cataract surgeries of people over age 90. Methods: From March 2007 to February 2009, we investigated eighty-two eyes of forty-eight patients who had undergone cataract surgeries at an ophthalmic clinic (Ansung, Kyungi-do), investigated maximum corrected vision, axial length, anterior chamber depth and accompanied ocular diseases before and after the surgeries based on the collected data. Results: As patients aged, axial length unchanged but anterior chamber depth decreased over all due to the increase of intraocular lens thickness, and men tended to have a higher degree than women. Seventy-one (86.6%) of eighty-two eyes showed improved corrected vision than before surgeries and forty-three (52.4%) eyes could see more than visual acuity of 0.5. Conclusions: Patients with the systemic disease and accompanied ocular disease showed low vision less than 0.5 after cataract surgery compared to same healthy age peoples. But the others improved correction visual acuity more than 0.5, so the cataract surgery was surely necessary for people over 90 years old and also the presence of ocular disease could have a great influence on correction visual acuity.

Comparison of Accommodative Response among Emmetropes, Spectacle and Contact Lens Wearer (정시, 안경 및 콘택트렌즈 착용자의 조절반응량 비교)

  • Lee, Kyu-Byung;Park, Jeehyun;Kim, Hyojin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.4
    • /
    • pp.403-410
    • /
    • 2012
  • Purpose: The purposes of this study are to investigate accommodative response among emmetropes, spectacle wearer and contact lens wearer, and correlation between refractive error and accommodative respons for each group. Methods: The 72 subjects(144 eyes) who do not have any ocular diseases were participate in this study. Subjects were categorized into emmetropes, spectacle wearer and contact lens wearer by refractive error using closed-field auto-refractometer. We measured dominant eye, naked/habitual visual acuity and refractive error of monocular/binocular vision of refractive error for far/near distance with open-field auto-refractometer and calculated accommodative lag. Results: There were no significant difference of accommodative lag between right and left eye dominant and non-dominant eye, monocular and binocular vision, and spectacle lens wearer and contact lens wearer, However the accommodative lag of binocular vision was severe than monocular vision at near. The lag of myopia was larger than emmetropes, and male was larger than female. Significant correlation was found between refractive error and accommodative lag in total subjects and the same result was found in emmetropes and contact lens wearer. However there were no significant correlation in the spectacle wearer. Conclusions: There were significant difference between emmetrops and myopes in terms of accommodative lag, however accommodative lag of spectacle wearer was not different with contact lens wearer in myopes. There were also significant correlation between refractive error and accommodative lag in emmetropes and contact lens wearer, but the accommodative lag of spectacle wearer was not significantly correlated with refractive error.

The Clinical Examination of Netspeg Lens for Good Visual Acuity (시력 개선을 위한 Netspeg 렌즈의 임상적 검증)

  • Kim, Douk-Hoon;Bae, Han-Young;Kim, Sun-Tae
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.3
    • /
    • pp.281-291
    • /
    • 2006
  • The aim of this study was performed the clinical test using Netspeg lens for good visual acuity on subjects with abnormal refraction status. The subjects of one hundreds adults (fifty males, fifty females, mean=21 years, range=19 to 24) were recorded. The subjects were researched the history including the systemic health, medication, genetics, allergy, systemic disease and ocular disease. The refraction test was recorded the monocular and binocular using objective method. Visual acuity was performed the binocular status using the Netspeg lens and CR-39. Stereopsis test was performed the titmus fly and TNO at near distance using Netspeg lens and CR-39. The P-VEP test was used the 16 pattern size(Bausch Lomb, production in USA) with three channels. Also Subjects viewed the p-vep stimulus with binocular vision through the corrected visual acuity using the Netspeg lens and CR-39. The contrast sensitivity test was performed the contrast sensitivity chart(pelli-Robertson, USA) at 1m distance using the Netspeg lens and CR-39. The ultrastructure of surface on the Netspeg lens and CR-39 was observed the SEM(JMS-5800, made in Japan). The results of this study was as follows: 1. In corrected visual acuity of abnormal refraction using the Netspeg lens and CR-39, the Netspeg lens wearer were acquired the good visual field and clear visual acuity comparative to CR-39 wearer in the subject vision test. however the comfort of visual acuity was similar results in the Netspeg lens and CR-39. Also the subjects of Netspeg lens wearer was good visual acuity more than CR-39 wearer and in the analysis of P-VEP, the amplitude of wave on Netspeg lens used appears to be better through the CR-39(p>0.5). Besides, on the contrast sensitivity, the Netspeg lens wearer was good results than CR-39. The value on stereopsis with TNO by Netspeg lens wearer was better than CR-39 in results. However, in the stereopsis test with Titmus, the Netspeg lens and CR-39 wearer was similar results. 2. The ultrastructure of Netspeg lens surface was the smooth and fine shape more than CR-39. Also, Netspeg lens have a fine line structure in ultrastructure. In conclusion, the results of this study conformed that the surface ultrastructure of Netspeg lens used is more specific pin hole design structure than CR-39. This study indicated that the vision of Netspeg lens used have a better than CR-39 in the corrected visual acuity for abnormal refraction eye. Therefore, In this paper, we suggested that the ultrastructure and line structure of Netspeg lens was related to good visual function. However the visual function of the aspheric Netspeg and ultra waterproof Netspeg lens was similar results.

  • PDF

The Corneal Effects Induced by Ultraviolet Radiation (자외선에 의한 각막의 영향)

  • Kim, Douk Hoon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.2
    • /
    • pp.229-234
    • /
    • 2002
  • The human eye and skin is exposed daily to solar energy. Expecially, the ultraviolet radiation (UVR) exposure has been damaged as an important causative factor in corneal disease. These damage of cornea was effected the retina. Therefore the eye function was effected very significant damage. As a results the protect of UVR in the eye is very important in ocular health. Therefore in living the intensive ultraviolet radiation environment by solar energy, human eye have protected the cornea and eyeball by the UV-blocking sunglass, eyeglass, goggles, and contact lens. Finally the specific UV-blocker lens devices available to the primary care for the subjects by optician. Of course, in the future these specific lenses have to development and study by fellowship.

  • PDF

Molecular characterization of Acanthamoeba isolated from amebic keratitis related to orthokeratology lens overnight wear

  • Lee, Jun-Joo;Jeong, Hae-Jin;Lee, Ji-Eun;Lee, Jong-Soo;Xuan, Ying-Hua;Kong, Hyun-Hee;Chung, Dong-Il;Ock, Mee-Sun;Yu, Hak-Sun
    • Parasites, Hosts and Diseases
    • /
    • v.44 no.4 s.140
    • /
    • pp.313-320
    • /
    • 2006
  • In an effort to characterize, on the molecular scale, the Acanthamoeba initially isolated from the cornea of an amoebic keratitis patient associated with overnight-wear orthokeratology lens in Korea, we conducted mitochondrial DNA restriction fragment length polymorphism, 18S rDNA sequencing, and drug sensitivity analyses on the isolate (KA/PE1). The patient was treated with polyhexamethylene biguanide, chlorhexidine and oral itraconazole, which resulted in resolution of the patient's ocular inflammation. The majority of the molecular characteristics of the KA/PE1 were determined to be identical, or quite similar, to those of A. castellanii Ma strain, which had been isolated also from amoebic keratitis. The risk of Acanthamoeba keratitis as a potential complication of overnight orthokeratology is briefly discussed.

A Study on the Prescription of Size Lens for Myopic Aniseikonia (근시성 부등상시의 등상시 렌즈 처방에 관한 고찰)

  • Kwon, Young-Seok;Kim, Ki-Hong;Lee, Hyun-Mee;Chu, Byoung-Sun;Kwon, Yun-Kyung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.4
    • /
    • pp.555-560
    • /
    • 2013
  • Purpose: The aims of this study were to investigate the stereoacuity and subjective symptoms of aniseikonia with prescription of the size lens. Methods: Participants were myopic anisometropia patients with the binocular refraction difference between 1.75 D~3.50 D. Inclusion criteria of participants were no ocular pathology, no amblyopia, more than 1.0 of corrected visual acuity. With fully corrected spectacles and a correction with the size lens, Awaya aniseikonia test and Randot Stereo test were conducted respectively. In addition, subjective symptoms were also examined using questionnaire. Results: As the anisometropia increased, the aniseikonia increased. Under the anisometropia with same refractive correction was different for each individual. The prescription of size lens caused less aniseikonia than the general prescription of glasses. In addition, prescription of the size lens improved stereoacuity and relieved the symptoms of asthenopia. Conclusions: The prescription of size lens that can correct aniseikonia with prescription of glasses can improve stereoacuity and reduced asthenopia.