• Title/Summary/Keyword: Ocular Image

Search Result 58, Processing Time 0.019 seconds

Optical system design for stereoscopic video-recorder (비디오 입체영상녹화를 위한 광학계 설계)

  • Hong, Kyung-Hee
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.6
    • /
    • pp.506-509
    • /
    • 2002
  • An optical system for a stereoscopic video recorder is designed with the field of view 42$^{\circ}$ and effective diameter 22 mm. We can use it by attaching it to the front lens of any video camera or camcorder to record a stereoscopic scene. This system is a double Kepler type afocal system to make the image erect and a bi-ocular type to record and display the stereoscopic scene. The optical tube length is folded with several flat mirrors and a beam splitter to be compact. This optical system is composed of 4 groups of lenses and each group serves as a relay lens for minimizing the vignetting effect. Whole field stereoscopic scenes may be captured by perpendicularly polarized alternated recording with a chopper and two perpendicular polarizers, without any loss of light energy. The displayed images may be seen stereoscopically with polarized spectacles and are kinetic because of an afterimage effect.

Development of Videooculograph for Vestibular Function Test (전정 기능 평가를 위한 영상 안구 운동 측정 시스템의 개발)

  • 김수찬;남기창;이원선;김덕원
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.40 no.3
    • /
    • pp.189-198
    • /
    • 2003
  • Videooculography (VOG) is one of the eye-movement measurement methods used for objective evaluation of vestibule -ocular reflex. A key feature of VOG is to estimate accurately the center of pupil and ocular torsion with being less influenced by the upper eyelid droop, eyelashes, corneal reflection, and eye blinks. Especially, it Is important to find the accurate center of the pupil in 3-D VOG because the inaccurate pupil center causes significant errors on measuring torsional eye movement. A new algorithm was proposed to find the center of pupil which is a little influenced by factors mentioned above. In this study, real time three-dimensional VOG which can measure horizontal, vortical, torsional eye movements, and the diameter of pupil was implemented using the proposed method.

The Study for Characteristics between Amorphous Selenium Plate Surface Potential and X-ray Exposure by Image Plate (Image Plate로서의 X선 조사에 대한 Amorphous Selenium Plate 표면 Potential 특성 연구)

  • Choi, J.Y.;Cho, S.Y.;Kim, M.S.;Lim, C.D.;Kim, D.H.;Nam, S.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.05
    • /
    • pp.41-44
    • /
    • 1996
  • There are studied for filmness methods due to disadvantage of conventional X-ray system. Have high DQE, high SNR, amorphous selenium was investigated with image plate. In this point, characteristics of all amorphous selenium image plate was investigated to understand the relationship between the amount of the X-ray exposure and the superficial charge potential in this study. Specially, changes in charge at the surface of the amorphous selenium plate with respect to change of X-ray energy(KeV) was investigated. It was found that the surface charge potential at the amorphous selenium inclosed with respect to the increse in X-ray exposure and that the changed surface potential was a semilinearity in 12.5KeV - 22.5KeV range. Therefore, which suggests that these results call be applied to the development of X-ray image plate.

  • PDF

The Influence of Hemosialysis to the Face Color of Patients in End Stage Renal Disease (말기신부전 환자의 혈액투석 치료가 안면 색에 미치는 영향)

  • Lee, Se-Hwan;Cho, Dong-Uk
    • The KIPS Transactions:PartB
    • /
    • v.17B no.6
    • /
    • pp.437-444
    • /
    • 2010
  • In this paper, we propose a method of analysing the relation between the patient's face color and his(her) kidney disease using image processing technology. This method is based on the ocular inspection which is one of the most famous diagnosis methods used in the oriental medical system. The way of processing and analysing the face image, which is for visualization and objectification of the color difference, is included. The objects are selected from the patients who suffer the kidney disease and use the hemodialyzer. Their facial images and clinical data are collected. From these data, we propose a hypothesis that the color of the patient's face is changed according to the patient's kidney state. At the same time, we present two algorithms of extracting the specific part of face which can identify the state of the patient's kidney and tracing the history of the color's change. This proposed method is evaluated through the practical experiments and their analysis.

Effects Analysis of Stimulating Lung Ear Reflex Point by Facial Appearance Analysis of Bio-signals (생체신호의 얼굴 발현 분석을 통한 폐 이혈 반사점 자극의 효과 분석)

  • Kim, Bong-Hyun;Cho, Dong-Uk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.6
    • /
    • pp.2812-2818
    • /
    • 2013
  • Medicine such as Korean oriental medicine and alternative medicine is inferior to western medicine in diagnostic skills and treatment regimen but despite going through a lot of in western medicine preference to that is situations. Likewise, in Korean oriental medicine and alternative medicine have been closely linked to that effect not proven scientifically to be solved is regarded as the biggest drawback. In this paper, auricular therapy that is often used in alternative medicine to help strengthen the internal organs function which whether the conduct of stimulating ear is effective or not by applying to ocular inspection of Korean oriental medicine is proposed. For this purpose, lung ear reflex points to stimulate were performed after the right cheek color by measuring stimulation before comparison and analysis of the experiments. In addition, in order to examine this first analysis of the human body to the lungs and the elements of image analysis is to study. Experimental result, derived b value increased to a value of the right cheek and the results by lung ear to stimulate reflex point.

A study on the Optical Properties of two component zoom copier lens system (2군 줌 복사기 렌즈계의 광학적 성능)

  • Ji, Taek Sang;Lim, Hyeon Seon;Kim, Bong Hwan
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.2
    • /
    • pp.119-125
    • /
    • 2000
  • We analyzed to calculate optical capacity after we chose established 2 component zoom copier lens system in this research. As the lens system is zoom lens system of finite object point, it has moving area limited not like to use generally camera zoom lens of infinite object point because it moves between object and image plane. The magnification of optical system can obtain -1.41~-0.64 i.e., extended or shortened image as transverse magnification, and it acquires f/12 and about $20^{\circ}$ field of view. Although this 2 component zoom copier lens system will be down resolution and dark compared with f/2.8 acquired at camera lens, it will be possibile to be able to make large aperture and it can acquire more better correct aberration with the addition of auxiliary group forward or backward.

  • PDF

Evaluation of Tear Film Lipid Layer Thickness Measurements Obtained Using an Ocular Surface Interferometer in Nasolacrimal Duct Obstruction Patients

  • Lee, Sang Min;Chung, Sok Joong;Lew, Helen
    • Korean Journal of Ophthalmology
    • /
    • v.32 no.6
    • /
    • pp.445-450
    • /
    • 2018
  • Purpose: To compare the tear film lipid layer thickness (LLT) between patients with incomplete nasolacrimal duct obstruction (NLDO) and normal controls and to analyze the changes in tear film LLT and blinking pattern after silicone tube intubation in NLDO patients. Methods: We reviewed the medical records of 68 eyes in 52 incomplete NLDO patients who underwent silicone tube intubation from January 2017 to July 2017. The LLT, blinking pattern, and Meibomian gland image were measured with the LipiView II ocular surface interferometer. The Meibomian gland drop-out ratio was measured using the polygon selection tool in the Image J program. Tear meniscus height, which is the other lacrimal indicator, was assessed with spectral-domain optical coherence tomography. Results: Tear meniscus height was significantly decreased after silicone tube intubation (p < 0.01). Preoperative minimum, maximum, and average LLT values were $62.4{\pm}24.0$, $86.7{\pm}17.9$, and $71.7{\pm}23.3nm$, respectively. Significant changes in the minimum, maximum, and average LLT ($74.8{\pm}23.6$, $98.8{\pm}11.0$, and $91.6{\pm}16.1nm$, respectively) were observed after silicone tube intubation (p < 0.001, p = 0.001, and p < 0.001). The partial blinking/total blinking ratio in 20 seconds and the Meibomian gland drop-out ratio showed no significant change after silicone tube intubation. Conclusions: Overall, the LLT was increased after silicone tube intubation. Silicone tube intubation may be helpful in maintaining LLT with a normalized of amount of tears.

Development of a vestibulo-ocular reflex measurement system for the study of cybersickness (사이버멀미 경감 연구를 위한 전정안구반사 측정 시스템 개발)

  • Jeon, Hyeonjin;Chang, EunHee;Wendimagegn, Tariku Weldtsadik;Park, Chan Hyun;Jeong, Ji Woon;Kim, Hyun Taek
    • Science of Emotion and Sensibility
    • /
    • v.18 no.1
    • /
    • pp.27-38
    • /
    • 2015
  • Vestibulo-ocular reflex (VOR) is a compensatory response of the extraocular muscles generated by vestibular signals to stabilize images on the retina during head/body movements. It has been reported that mismatches between retinal and vestibular information, which cause motion sickness or cybersickness, modify VOR. To investigate the characteristic changes of VOR in subjects experiencing cybersickness, we developed a low-cost, multi-purpose VOR measurement system using LabVIEW and Arduino. To test the applicability of the system, we performed two experiments. In Experiment 1, horizontal and vertical VORs of four participants were measured using a vestibular autorotation task. In Experiment 2, eight participants were exposed to a virtual navigation to measure changes of VORs as an index of cybersickness. We observed significantly greater head rotations and eye movements while the participants were exposed to the virtual navigation than to a static image. The results suggest that the present system can help understand the psychophysiological mechanisms of cybersickness symptoms.

Gamma Knife Radiosurgery for Cancer Metastasized to the Ocular Choroid

  • Cho, Kyung Rae;Lee, Kyung Min;Han, Gyule;Kang, Se Woong;Lee, Jung-Il
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.1
    • /
    • pp.60-65
    • /
    • 2018
  • Objective : Choroidal metastases (CMs) are the most common intraocular tumor. Management is mainly radiation therapy with goals of pain control and visual improvement. However, many radiation-related complications are reported. Since gamma knife radiosurgery (GKS) for CM was first reported in 1995, few cases have been reported. We report 7 cases of CMs treated with GKS. Methods : From April 2011 to November 2014, 7 patients with CM underwent GKS. Their median age at treatment was 64 years (range, 51-71 years). Four males and three females were treated. Lung cancer was the most common primary pathology, followed by renal cell carcinoma and stomach cancer. Four patients had multiple cerebral lesions and were treated simultaneously for choroidal lesions. The median marginal dose of 20 Gy (range, 15-25 Gy) was administered at the 50% isodose line. Results : Median follow-up period after GKS was 8 months (range, 2-38.3 months). Four patients expired due to underlying malignancy progression. Except for two patients who were not followed with magnetic resonance image after GKS, all patients showed size reduction in the treated lesions, but a new choroidal lesion appeared in one patient and one recurred. Six of seven patients reported subjectively improved visual symptoms. Visual acuity improved in 2 patients, and 2 were stable upon objective examination. One patient showed no improvement in visual acuity, but ocular pain was relieved; another patient showed improved vision and tumor remission, but visual deterioration recurred. Conclusion : GKS was shown to be safe and effective and should be considered for CM treatment.

Visual Performances of the Corrected Navarro Accommodation-Dependent Finite Model Eye (안구의 굴절능 조절을 고려한 수정된 Navarro 정밀모형안의 시성능 분석)

  • Choi, Ka-Ul;Song, Seok-Ho;Kim, Sang-Gee
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.5
    • /
    • pp.337-344
    • /
    • 2007
  • In recent years, there has been rapid progress in different areas of vision science, such as refractive surgical procedures, contact lenses and spectacles, and near vision. This progress requires a highly accurate modeling of optical performance of the human eyes in different accommodation states. A new novel model-eye was designed using the Navarro accommodation-dependent finite model eye. For each of the vergence distances, ocular wavefront error, accommodative response, and visual acuity were calculated. Using the new model eye ocular wavefront error, accommodation dative response, and visual acuity are calculated for six vergence stimuli, -0.17D, 1D, 2D, 3D, 4D and -5D. Also, $3^{rd}\;and\;4^{th}$ order aberrations, modulation transfer function, and visual acuity of the accommodation-dependent model eye were analyzed. These results are well-matched to anatomical, biometric, and optical realities. Our corrected accommodation-dependent model-eye may provide a more accurate way to evaluate optical transfer functions and optical performances of the human eye.