• Title/Summary/Keyword: Occupation therapy

Search Result 176, Processing Time 0.03 seconds

Radiotherapy Incidents Analysis Based on ROSIS: Tendency and Frequency (ROSIS 자료 기반 방사선 사고 사례 분석 : 경향과 빈도)

  • Koo, Jihye;Yoon, MyongGeun;Chung, Won Kuu;Kim, Dong Wook
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.298-303
    • /
    • 2014
  • In this study, we examine the trends and types of incidents frequently occur during radiation therapy by using the data from the radiation oncology safety information system (ROSIS), according to discovery method explores the development direction of future research accident cause factor control method. This study was carried out analysis of incident data in ROSIS nearly 1163 cases in last 11 years from 2003 to 2013. We categorized into treatment methods, found the time, discoverer of occupations and finding ways to analyze the data. Then, we calculate the percentage and the classification for each item. About 1163 cases of incident cases including the near miss cases, external radiation therapy, brachytherapy and other were 97%, 2% and 1%. In the case was improperly planned dose delivery was 44% (497 cases) which 429 cases (86%) was found before 3 fractions and 13 cases were found after 11 fractions. The investigation was found to be distributed in various a found times. Approximately 42% of found time was during treatment and 29% of patients were found the problem during inspection chart. Occupation to discover the most radiation accidents was the radiation therapist (53%) who works in treatment room. Among 1163 incidence cases, 24% cases were found the accident before the treatment, therefore most of accident were found after of during the treatment (70%, 813 cases). This trend is acquired through ROSIS analysis, is expected to be not significantly different in the case of Korea, so it is necessary more diverse and systematic research for the prevention and early detection by using the ROSIS data.

Factors Influencing the Therapeutic Compliance of Patients with Lung Cancer (폐암환자의 치료순응도에 영향을 미치는 요인)

  • Chae, Sang-Chul;Park, Jae-Yong;Kim, Jeong-Suk;Bae, Moon-Seob;Shin, Moo-Chul;Kim, Keon-Yeob;Kim, Chang-Ho;Shon, Sang-Kyun;Kam, Sin;Jung, Tae-Hoon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.5
    • /
    • pp.953-961
    • /
    • 1998
  • Background : In recent years, lung cancer has been one of most common cause of death in Korea. Despite many physician's high degree of pessimism about the gains made in treatment, progressive improvement in the survival of lung cancer by treatment has occurred, particulary in the early stages of the disease. However, a lot of patients refuse treatment or give up in the fight against the disease. This study was done to evaluate factors influencing the compliance to therapy and to lead in the establishment of special programs to enhance compliance in patients with lung cancer. Methods: The medical records of 903 patients, whose ECOG(Eastern Cooperative Oncology Group) performance status was 3 or less and whose medical record was relatively satisfactory, among 1141 patients diagnosed with lung cancer between January 1989 and December 1996 were reviewed retrospectively. Compliance was classified into three groups based on the degree of compliance with physicians practice guideline: (a) compliants; (b) patients who initially complied but gave up of themselves midway during the course of treatment; (c) noncompliants who refused the treatment. Results: The overall compliance rate was 63.9%, which was progressively increased from 57.3-61.3% in 1989 and 1990 to 64.2-67.5% in 1995 and 1996. Age, education level and occupation of patients bore statistically significant relationship with the compliance but sex, marital status and smoking history did not. The compliance was significantly higher in patients without symptoms than with, and was also significantly higher in patients with good performance status. The compliance was significantly high in patients with NSCLC(non-small cell lung cancer) compared to SCLC(small cell lung cancer), but after exclusion of stage I and II, among NSCLC, which had higher compliance to surgery there was no significant difference of compliance by histology. The compliance was significantly lower in advanced stage. Conclusion: To enhance the compliance, special care including education programs about therapy including complication and prognosis are necessary, especially for educationally and economically disadvantaged patients.

  • PDF

A Study on the Accessibility Requirements Analysis Model for the Preventive Safety and Disaster Service Information System - Focusing on the Communication Ability (정보시스템을 통한 생활안전 위험의 예방·대응을 위한 안전약자 요구사항 분석모델 연구 : 의사소통기능을 중심으로)

  • Lee, Yong-Jick;Ji, Seok-yeon;Kim, Sang-hwa
    • The Journal of Korean society of community based occupational therapy
    • /
    • v.10 no.3
    • /
    • pp.1-13
    • /
    • 2020
  • Objective : The purpose of this study is to present an analysis model in developing an inclusive response for safety hazards and disaster preventive information system for vulnerable people to the disaster including persons with disabilities, and those with specific needs. Methods : In this study, the persona analysis method is used to analyze fictitious characters that correspond to various characteristics such as age, disability, environment, occupation, etc. in terms of the scenario of some particular disaster subjects. Based on the user's communication problems derived from the persona analysis, focused group interview and ICF based analysis were implemented to identify needs and arbitration methods. Results : The needs from persona analysis and ICF-based communication items analysis identifies the factors that make each fictitious character difficult in terms of communication in obtaining the benefits consistent with the purpose of the service. The study derives service requirements that can provide arbitration or facilitation methods to increase communication ability of the users. Conclusion : Through the persona analysis method, difficulties that could occur when receiving disaster information using communication devices were identified and analyzed in conjunction with communication problems described in the ICF. In building information services for the prevention of safety hazards and disasters, this study presented a model that uses the persona analysis method and the ICF classification system to derive user requirements for accessible information system.

Shielding for Critical Organs and Radiation Exposure Dose Distribution in Patients with High Energy Radiotherapy (고 에너지 방사선치료에서 환자의 피폭선량 분포와 생식선의 차폐)

  • Chu, Sung-Sil;Suh, Chang-Ok;Kim, Gwi-Eon
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.1
    • /
    • pp.1-10
    • /
    • 2002
  • High energy photon beams from medical linear accelerators produce large scattered radiation by various components of the treatment head, collimator and walls or objects in the treatment room including the patient. These scattered radiation do not provide therapeutic dose and are considered a hazard from the radiation safety perspective. Scattered dose of therapeutic high energy radiation beams are contributed significant unwanted dose to the patient. ICRP take the position that a dose of 500mGy may cause abortion at any stage of pregnancy and that radiation detriment to the fetus includes risk of mental retardation with a possible threshold in the dose response relationship around 100 mGy for the gestational period. The ICRP principle of as low as reasonably achievable (ALARA) was recommended for protection of occupation upon the linear no-threshold dose response hypothesis for cancer induction. We suggest this ALARA principle be applied to the fetus and testicle in therapeutic treatment. Radiation dose outside a photon treatment filed is mostly due to scattered photons. This scattered dose is a function of the distance from the beam edge, treatment geometry, primary photon energy, and depth in the patient. The need for effective shielding of the fetus and testicle is reinforced when young patients ate treated with external beam radiation therapy and then shielding designed to reduce the scattered photon dose to normal organs have to considered. Irradiation was performed in phantom using high energy photon beams produced by a Varian 2100C/D medical linear accelerator (Varian Oncology Systems, Palo Alto, CA) located at the Yonsei Cancer Center. The composite phantom used was comprised of a commercially available anthropomorphic Rando phantom (Phantom Laboratory Inc., Salem, YN) and a rectangular solid polystyrene phantom of dimensions $30cm{\times}30cm{\times}20cm$. the anthropomorphic Rando phantom represents an average man made from tissue equivalent materials that is transected into transverse 36 slices of 2.5cm thickness. Photon dose was measured using a Capintec PR-06C ionization chamber with Capintec 192 electrometer (Capintec Inc., Ramsey, NJ), TLD( VICTOREEN 5000. LiF) and film dosimetry V-Omat, Kodak). In case of fetus, the dosimeter was placed at a depth of loom in this phantom at 100cm source to axis distance and located centrally 15cm from the inferior edge of the $30cm{\times}30cm^2$ x-ray beam irradiating the Rando phantom chest wall. A acryl bridge of size $40cm{\times}40cm^2$ and a clear space of about 20 cm was fabricated and placed on top of the rectangular polystyrene phantom representing the abdomen of the patient. The leaf pot for testicle shielding was made as various shape, sizes, thickness and supporting stand. The scattered photon with and without shielding were measured at the representative position of the fetus and testicle. Measurement of radiation scattered dose outside fields and critical organs, like fetus position and testicle region, from chest or pelvic irradiation by large fie]d of high energy radiation beam was performed using an ionization chamber and film dosimetry. The scattered doses outside field were measured 5 - 10% of maximum doses in fields and exponentially decrease from field margins. The scattered photon dose received the fetus and testicle from thorax field irradiation was measured about 1 mGy/Gy of photon treatment dose. Shielding construction to reduce this scattered dose was investigated using lead sheet and blocks. Lead pot shield for testicle reduced the scatter dose under 10 mGy when photon beam of 60 Gy was irradiated in abdomen region. The scattered photon dose is reduced when the lead shield was used while the no significant reduction of scattered photon dose was observed and 2-3 mm lead sheets refuted the skin dose under 80% and almost electron contamination. The results indicate that it was possible to improve shielding to reduce scattered photon for fetus and testicle when a young patients were treated with a high energy photon beam.

Developed an output device for high-frequency cosmetic medical equipment using micro multi-needle (마이크로 멀티니들을 이용한 고주파 피부미용 의료기기를 위한 출력 장치 개발)

  • Kim, Jun-tae;Joo, Kyu-tai;Cha, Eun Jong;Kim, Myung-mi;Jeong, Jin-hyoung
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.14 no.5
    • /
    • pp.394-402
    • /
    • 2021
  • The entry of an aging society and the extension of human life expectancy, the increasing interest in women's social advancement and men's appearance, and the natural interest in K-culture through media media, while receiving worldwide attention, Focus on K-Bueaty. Recently, looking at the occupation of the medical tourism field, in the case of aesthetic medicine tourism such as molding and dermatology, it has gained popularity not only in Asia such as China and Japan, but also in North America and Europe. The first external confirmation of human aging is the wrinkles on the skin of the face. Clean, wrinkle-free, elastic and healthy skin is a desire of most people. Skin condition and condition such as focused ultrasonic stimulation (HIFU: High Intensity Focused Utrasound) and low frequency, high frequency (RF: Radio Frequency), galvanic therapy using microcurrent, cryotherapy using rapid cooling, etc. Depending on the method of management, the effect of the treatment differs depending on the output and the stimulation site, etc., even in the treatment of medical equipment and beauty equipment using the same mechanism. In this research, in order to develop invasive high-frequency dermatological devices using a large number of beauty medical devices and microneedles of beauty devices, the international standards IEC 60601-2 (standards for individual medical devices) and MFDS (Ministry of) We designed and developed a high-frequency output device in compliance with the high-frequency stimulation standard announced in the Food and Drug Safety (Ministry of Food and Drug Safety). The circuit design consists of an amplifier (AMP: Amplifier) using Class-A Topology and a power supply device using Half-Bridge Topology. As a result of measuring the developed high-frequency output device, an average efficiency of 63.86% was obtained, and the maximum output was measured at 116.7W and 50.67dBm.

Diving patterns and diving related disease of diving fishermen in Korea (수산물채취 잠수부의 작업특성과 잠수관련질환의 양상)

  • SaKong, Joon
    • Journal of Preventive Medicine and Public Health
    • /
    • v.31 no.1 s.60
    • /
    • pp.139-156
    • /
    • 1998
  • Diving related disease including decompression sickness is an important occupational health problem and diving fishermen remain a fairly hazardous occupation in Korea. To prevent diving related disease, we investigate diving patterns, incidence of diving related diseases, and contributing factors of 433 diving fishermen of three coast interviewing and mailing questionnaire in 1996. Mean age of divers was 39.7 years, ranged from 24 to 58 years, 92.8% of these were male, and 58.4% of divers were high school graduates. Mean duration of work as a diver was 12.9 years, ranged from 2 to 40 years. It was found that 70.4% of divers were using hookah system, 22.2% of helmet, and only 2.5% SCUBA. About half of them have learned diving skills from other divers. The peak season of diving was from April to June and mean working days were 20.3 days per month during the peak season. On the average, the divers dived 5-6 times, ranged from 1 to 10 times a day with 51.1 minutes of diving time, ranged from 20 to 120 minutes, at 30 m or 40 m in depth, and 35.5 minute of interval on surface. Most divers ascended slowly making decompression stop, yet the decompression profile used was not based on any scientific knowledge except for their own experiences. It appeared that each diving system had slightly different diving patterns. There were 282(65.0%) divers that suffered from DCS in 1995 and 31.2% of divers were given recompression therapy at a medical facility since they worked as diving fishermen. Skin and musculoskeletal complaints were common symptoms of DCS and 39% of divers experienced a voiding difficulty. In univariate analysis, females have an increased frequency of DCS(93% vs 66% for males). Old age, long duration of work, helmet diving, diving time, diving depth, repetitive diving, and blow up were all contributing factors to DCS. It was found that most diving patterns exceed no decompression limit and did not use the standard decompression table. This suggests that most of divers are at high risk of developing diving related disease with prolonged dives and lengthy repetitive diving in deep depth. Considering the diving patterns and economic aspect of professional diving, the incidence of DCS among diving fishermen in Korea will not decrease in the near future. These findings suggest that periodical health surveillance for divers, and education of health and safety are important for reducing the risk of diving related disease in the population of diving fishermen.

  • PDF