• Title/Summary/Keyword: Occlusion type

Search Result 292, Processing Time 0.021 seconds

CLINICAL EVALUATION OF TREATMENT OUTCOME OF PLATING TECHNIQUE OF FIXATION FOR MANDIBULAR CONDYLAR FRACTURE (하악 과두 골절의 관혈적 정복시 고정 방법에 따른 임상적 평가)

  • Son, Jung-Hee;Park, Ji-Hwa;Kim, Chin-Soo;Byun, Ki-Jung
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.27 no.2
    • /
    • pp.164-170
    • /
    • 2005
  • The purpose of this study was to compare a sample of patients who had condylar fractures treated with open reduction using different plating techniques, to evaluate which plating technique is useful for stable fixation for fractures of the mandibular condyle and to evaluate effectiveness of resorbable miniplate. There were 60 patients (41 males, 19 females) whose condylar fractures were treated with open reduction. Rigid fixation was performed with a single miniplate, double miniplate ot one miniplate & one microplate and single resorbable plate. All patients remained intermaxillary fixation for 1 week postoperatively. Active physiotherapy was started after 2 weeks postoperatively. Radiographic evaluation (plate fracture, plate bending, screw loosening, displacement of condyle etc.) was performed at pre-operative, immediate, 2 weeks, 1 month, 3 months, 6 months after surgery. Clinical evaluation included degree of mouth opening, occlusion, mandibular lateral excursion, infection and facial nerve paralysis. In radiographic evaluation, displacement of fractured condylar segment associated with plate bending or screw loosening were showed 6 cases and 3 cases for single miniplate system and resorbable miniplate system. There was no patients who have this problem on double miniplate system. The results revealed that the application of two miniplates were more recommendable than single miniplates. When we select resorbable miniplate system, we should consider the type of fractures, post-operative treatment protocol and surgical technique.

An Improved VTON (Virtual-Try-On) Algorithm using a Pair of Cloth and Human Image (이미지를 사용한 가상의상착용을 위한 개선된 알고리즘)

  • Minar, Matiur Rahman;Tuan, Thai Thanh;Ahn, Heejune
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.25 no.2
    • /
    • pp.11-18
    • /
    • 2020
  • Recently, a series of studies on virtual try-on (VTON) using images have been published. A comparison study analyzed representative methods, SCMM-based non-deep learning method, deep learning based VITON and CP-VITON, using costumes and user images according to the posture and body type of the person, the degree of occlusion of the clothes, and the characteristics of the clothes. In this paper, we tackle the problems observed in the best performing CP-VTON. The issues tackled are the problem of segmentation of the subject, pixel generation of un-intended area, missing warped cloth mask and the cost function used in the learning, and limited the algorithm to improve it. The results show some improvement in SSIM, and significantly in subjective evaluation.

Is Stent-Assisted Coil Embolization for the Treatment of Ruptured Blood Blister-Like Aneurysms of the Supraclinoid Internal Carotid Artery Effective? : An Analysis of Single Institutional Experience with Pooled Data

  • Roh, Haewon;Kim, Junwon;Suh, Sang-il;Kwon, Taek-Hyun;Yoon, Wonki
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.2
    • /
    • pp.217-228
    • /
    • 2021
  • Objective : Given the high risk of rebleeding and recurrence of blood blister-like aneurysms (BBAs), we treated ruptured BBAs of the internal carotid artery (ICA) with stent-assisted coil embolization (SAC). This study aimed to evaluate the efficacy and safety of SACs. Methods : We retrospectively reviewed clinical and radiological data from eight patients with ruptured BBAs of the supraclinoid ICA. The modified Rankin Scale (mRS) was used to assess clinical outcomes, while radiological outcomes were evaluated on angiographs. For a pooled analysis, data from literature reporting the outcomes of ruptured BBAs treated with SAC were collected and analyzed in conjunction with our data. Results : In our cohort, the mean Raymond classification score was 1.57±0.53 immediately after initial endovascular treatment. There were no perioperative complications or rebleeding events during the follow-up period. The mean mRS score at patient discharge was 1.00±0.81 and improved to 0.28±0.48 by the last follow-up day. The recurrence rate was 25% with an asymptomatic presentation and successful treatment with multiple stent insertion. Pooled analysis of 76 cases of SAC revealed a complete occlusion rate immediately after treatment of 54.8%, rebleeding rate 7.94%, and recurrence rate 24.2%. Good clinical outcomes with mRS score 0-2 were observed in 89.9% by the last clinical follow-up. Total mortality rate was 7.7%. Conclusion : This treatment appears to not only minimize the hemodynamic burden on the fragile dome specific to this type of aneurysm, but also provides an opportunity for safe and effective treatment in recurrent cases.

Case reports of iatrogenic vascular injury in the trauma field: what is the same and what is different?

  • Kim, Youngwoong;Choi, Kyunghak;Choi, Seongho;Keum, Min Ae;Kim, Sungjeep;Kyoung, Kyu-Hyouck;Kim, Jihoon T;Noh, Minsu
    • Journal of Trauma and Injury
    • /
    • v.35 no.2
    • /
    • pp.123-127
    • /
    • 2022
  • Iatrogenic vascular injury (IVI) can occur with any technique or type of surgery performed around a blood vessel. Patients with severe trauma are at risk of IVI. In this study, we describe our experiences of IVI in the trauma field. We reviewed five patients who were diagnosed with an IVI and received either surgical or endovascular treatment. Of the five patients, one had an arterial injury, three had venous injuries, and one had an arteriovenous fistula, a form of combined arterial and venous injuries. Of the five patients, four had undergone orthopedic surgery. The IVIs of three patients were immediately identified in the operating room and simultaneous vascular repair was performed. The remaining one patient underwent additional surgery for occlusion related to entrapment of the superficial femoral artery by a surgical wire used during orthopedic surgery. Complications presumably related to the IVI were identified in two patients. IVI in trauma patients can be successfully managed, but significant morbidity can occur. If an IVI is suspected, immediate evaluation and management are required.

A case of direct restore using 4-META/MMA-TBB resin containing organic filler in patients with severe occlusal surface wear and enamel fracture (심한 교합면 마모 및 교두 파절 환자에서 유기필러를 함유한 4-META/MMA-TBB 레진을 활용한 직접수복 증례)

  • Dae-Sik Kim;Gyeong-Je Lee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.39 no.4
    • /
    • pp.222-228
    • /
    • 2023
  • Attrition is the loss of tooth hard tissue due to contact between teeth, and in severe cases, dentin is exposed, accompanied by selective corrosion and excessive wear of teeth, which is called cupping. If these lesions are left untreated, the size of the lesion gradually increases, breaking the unsupported enamel, resulting in a decrease in aesthetics and chewing function. In this case report, patients with cupping and enamel fracture due to severe attrition were directly restored using a resin with soft properties containing organic fillers. In the follow-up observation six years later, most of the filling of the occlusal surface was eliminated, but the filling on the buccal surfaces remained relatively intact, and it was confirmed that this type of resin was suitable for the area where the occlusal force was relatively weak rather than the area where the occlusal force was greatly applied.

STANDARDS FOR KOREAN ADULT FACIAL RELATIONSHIPS BY VARIOUS ROENTGENO - CEPHALOMETRIC ANALYSIS (두부(頭部)X선(線) 규격(規格) 측모사진계측(側貌寫眞計測)에 의한 한국인(韓國人) 성년남녀(成年男女)의 표준치(標準値)에 관(關)한 연구(硏究))

  • Lee, Chong Taik
    • The korean journal of orthodontics
    • /
    • v.18 no.2
    • /
    • pp.459-474
    • /
    • 1988
  • A study was made of a method of rational assessment on the roentgeno-cephalogram in orthodontic practice. Fifty eight measurements were analyzed on the roentgeno-cephalograms of 50 male and 50 female Korean adults with the acceptable profile and the normal occlusion. The means and standard deviations of measurements were studied in male and female groups by various analytic methods, and the sex difference was examined statistically. The obtained data were compared with those of the Japanese and American standards by useing a Japanese adults standard polygon chart reported by lizuka and Ishikawa. Amongs of 58 measurements, 14 have been selected as statistically significant and clinically useful, and used to make a Korean adult standard polygon chart. The results obtained were as follows: 1. Standards for cphalometric analysis in Korean adults were obtained, and the polygon chart and cephalometric profilogram were also made by using the standards in order to apply to a clinical diagnosis. 2. The sex difference was recognized in linear measurements, but not in angular measurments. 3. In comparison with the American standards from Downs and Graber, the Korean showed significant differences in angle of convexity, mandibular plane angle, Y-axis angle, interincisal angle and lower incisor to mandibular plane angle. Thus, the Korean showed a more retruded chin position, convex facial type, than white people. 4. In comparison with the Japanese standards from Iizuka and Ishikawa, the Korean showed a significant similarity with the Japanese, especially in females. 5. Upper incisor to Huxely line angle, established as a new measurement, proved to be paralell to X-Y axis angle.

  • PDF

Effect of Implant Types and Bone Resorption on the Fatigue Life and Fracture Characteristics of Dental Implants (임플란트 형태와 골흡수가 임플란트 피로 수명 및 파절 특성에 미치는 효과에 관한 연구)

  • Won, Ho-Yeon;Choi, Yu-Sung;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.2
    • /
    • pp.121-143
    • /
    • 2010
  • To investigate the effect of implant types and bone resorption on the fracture characteristics. 4 types of Osstem$^{(R)}$Implant were chosen and classified into external parallel, internal parallel, external taper, internal taper groups. Finite elements analysis was conducted with ANSYS Multi Physics software. Fatigue fracture test was performed by connecting the mold to the dynamic load fatigue testing machine with maximum load of 600N and minimum load of 60N. The entire fatigue test was performed with frequency of 14Hz and fractured specimens were observed with Hitachi S-3000 H scanning electron microscope. The results were as follows: 1. In the fatigue test of 2 mm exposed implants group, Tapered type and external connected type had higher fatigue life. 2. In the fatigue test of 4 mm exposed implants group, Parallel type and external connected types had higher fatigue life. 3. The fracture patterns of all 4 mm exposed implant system appeared transversely near the dead space of the fixture. With a exposing level of 2 mm, all internally connected implant systems were fractured transversely at the platform of fixture facing the abutment. but externally connected ones were fractured at the fillet of abutment body and hexa of fixture or near the dead space of the fixture. 4. Many fatigue striations were observed near the crack initiation and propagation sites. The cleavage with facet or dimple fractures appeared at the final fracture sites. 5. Effective stress of buccal site with compressive stress is higher than that of lingual site with tensile stress, and effective stress acting on the fixture is higher than that of the abutment screw. Also, maximum effective stress acting on the parallel type fixtures is higher. It is careful to use the internal type implant system in posterior area.

SHORT-TERM EFFECTS OF THE FUNCTIONAL REGULATOR III APPLIED TO ANTERIOR CROSSBITE PATIENTS IN EARLY MIXED DENTITION (기능성 반대교합을 가진 초기 혼합치열기 어린이에서 FR III를 단기간 장착했을 때의 효과)

  • Woo, Se-Eun;Nam, Soon-Hyeun;Kim, Young-Jin;Kim, Hyun-Jung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.39 no.3
    • /
    • pp.293-300
    • /
    • 2012
  • In case of treating the functional type of anterior cross bite, removing the cause in early stage prevents from turning to skeletal type, leads to perform normal function, and has improved facial appearance. Functional Regulator III (FR III), one kind of the Functional regulator(FR)s suggested by R$\ddot{o}$lf Fr$\ddot{a}$nkel in 1966, applied to patients with the functional and skeletal anterior crossbite in early mixed, and permanent dentition. This appliance improves unbalanced power condition by blocking abnormal muscle-power effect, so that normal growth can be expected. In this case report, favorable results were obtained by selecting clinical cases of children in their early mixed dentition with functional cross bite. 1. FR IIIs were applied to patients with anterior crossbite for 5~6 months. Anterior crossbite patients were corrected favorably, nevertheless they didn't show any horizontal skeletal-changes by buccal shields. 2. Normal occlusion and esthetic facial contour were achieved from dental movement of maxillary and mandibular anterior teeth while the mandible rotates to posterior and inferior direction.

The Effects of Thermocycling on the Shear Bond Strength between Metal Denture Base and Relining Resin (Thermocycling이 첨상용 레진과 금속 의치상간의 전단결합강도에 미치는 영향)

  • Lee, Joon-seok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.21 no.2
    • /
    • pp.95-103
    • /
    • 2005
  • Purpose: Recently, various metal primers have been developed, and these are known to increase the bond strength between metal and relining resin. In this study, the change in bond strength according to amount of thermocycling was evaluated. Materials and Methods: In this study, 216 specimens were fabricated. Tokuyama Rebase $II^{(R)}$(Tokuyama Corp., Japan) and $Kooliner^{(R)}$(GC America Inc., Japan) as relining material, and MR. $Bond^{(R)}$(Tokuyama Corp., Japan) and Alloy $Primer^{(R)}$(Kuraray Medical Inc., Japan) as a metal primers were used. Using Ni-Cr and various metal surface treatment methods, resin was bonded and the change in bond strength during thermocycling was measured. The data was analyzed by one-way ANOVA, t-test(p<.05 level of significance). Results: When comparing the groups with only sandblasting, rapid decrease in shear bond strength could be seen. In the groups using Tokuyama Rebase $II^{(R)}$, with the exception of the 1000 and 2000 cycle groups, each group showed statistically significant decrease in shear bond strength(p<0.05). In comparison according to relining materials, $Kooliner^{(R)}$ showed higher shear bond strength than Tokuyama Rebase $II^{(R)}$ in all groups. In groups using MR $bond^{(R)}$, $Kooliner^{(R)}$ had higher shear bond strength than Tokuyama Rebase $II^{(R)}$ but, there was no statistical significance(p<0.05). In the other groups, $Kooliner^{(R)}$ showed significantly higher shear bond strength(p<0.05). There was significant difference between groups with sandblasting and metal primer treatments(p<0.05). In comparison according to metal primer materials, Alloy $Primer^{(R)}$ showed the highest shear bond strength but there was no statistical significance(p>0.05). According to the number of thermocycling cycles, when using Tokuyama Rebase $II^{(R)}$, there were no significant differences between the 0, 1000 and 2000 cycle groups regardless of the type of metal primer. There were no differences between the 2000 and 3000 cycle groups. When using $Kooliner^{(R)}$, regardless of the type of metal primer, there were no significant differences between the 0, 1000, 2000 and 3000 cycle groups(p>0.05). Conclusion: The use of metal primers showed increase in bond strength, and the stability after to thermocycling has been authenticated. Thus, the use of metal primers in relining and rebasing of metal frameworks is essential. But when selecting the material various physical properties should be considered.

Evaluation of the Volume Changes of Grafted Bone Materials in Sinus Augmentation Procedure Using Dental Cone-beam CT (치과용 Cone-beam CT를 이용한 상악동 골 이식 후 나타난 골 이식재의 부피 변화평가)

  • Ohn, Byung-Hun;Seon, Hwa-Kyeong;Chee, Young-Deok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.1
    • /
    • pp.23-36
    • /
    • 2013
  • To evaluate the 3-dimensional features of the grafted bone with maxillary sinus augmentation and to assess the relation between the degree of bone resorption and the type of bone grafting source and implant, and the operation method. A retrospective chart review of patients receiving sinus augmentation procedures for implant positioning was conducted: radiographic analysis of the volume and area of bone grafts was performed. The volumetric remodeling.measured at 6 months after implant positioning as the percentage of residual bone graft.was correlated to type of graft materials and operation methods. 53 dental implants positioned with sinus bone graft in 15 patients at Wonkwang University Sanbon Dental Hospital. Computed tomography scans,taken implant positioning after 6 months, showed greater resorption values for the group of $Puros^{(R)}$ graft alone from the group of mixed with $Puros^{(R)}$ and various bone graft (P<0.05, respectively). And resorption values according to operation methods have statistically significant difference(P<0.05). Volume change ratio of bone graft showed greater values for the group of delayed implant position from the group of simultaneously implant placement with bone graft. Retrospective data analysis shows that the method of graft with $Puros^{(R)}$ alone may occur greater resorption of graft materials than mixed graft material with $Puros^{(R)}$ and other graft materials. The group of simultaneously implant placement with bone graft also display smaller resorption ratio of bone graft than the group of delayed implant placement.