• Title/Summary/Keyword: Oblique Image

Search Result 134, Processing Time 0.026 seconds

3D Model Generation and Accuracy Evaluation using Unmanned Aerial Oblique Image (무인항공 경사사진을 이용한 3차원 모델 생성 및 정확도 평가)

  • Park, Joon-Kyu;Jung, Kap-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.3
    • /
    • pp.587-593
    • /
    • 2019
  • The field of geospatial information is rapidly changing due to the development of sensor and data processing technology that can acquire location information. And demand is increasing in various related industries and social activities. The construction and utilization of three dimensional geospatial information that is easy to understand and easy to understand can be an essential element to improve the quality and reliability of related services. In recent years, 3D laser scanners are widely used as 3D geospatial information construction technology. However, 3D laser scanners may cause shadow areas where data acquisition is not possible when objects are large in size or complex in shape. In this study, 3D model of an object has been created by acquiring oblique images using an unmanned aerial vehicle and processing the data. The study area was selected, oblique images were acquired using an unmanned aerial vehicle, and point cloud type 3D model with 0.02 m spacing was created through data processing. The accuracy of the 3D model was 0.19m and the average was 0.11m. In the future, if accuracy is evaluated according to shooting and data processing methods, and 3D model construction and accuracy evaluation and analysis according to camera types are performed, the accuracy of the 3D model will be improved. In the point cloud type 3D model, Cross section generation, drawing of objects, and so on, it is possible to improve work efficiency of spatial information service and related work.

Prediction of successful caudal epidural injection using color Doppler ultrasonography in the paramedian sagittal oblique view of the lumbosacral spine

  • Yoo, Seon Woo;Ki, Min-Jong;Doo, A Ram;Woo, Cheol Jong;Kim, Ye Sull;Son, Ji-Seon
    • The Korean Journal of Pain
    • /
    • v.34 no.3
    • /
    • pp.339-345
    • /
    • 2021
  • Background: Ultrasound-guided caudal epidural injection (CEI) is limited in that it cannot confirm drug distribution at the target site without fluoroscopy. We hypothesized that visualization of solution flow through the inter-laminar space of the lumbosacral spine using color Doppler ultrasound alone would allow for confirmation of drug distribution. Therefore, we aimed to prospectively evaluate the usefulness of this method by comparing the color Doppler image in the paramedian sagittal oblique view of the lumbosacral spine (LS-PSOV) with the distribution of the contrast medium observed during fluoroscopy. Methods: Sixty-five patients received a 10-mL CEI of solution containing contrast medium under ultrasound guidance. During injection, flow was observed in the LSPSOV using color Doppler ultrasonography, following which it was confirmed using fluoroscopy. The presence of contrast image at L5-S1 on fluoroscopy was defined as "successful CEI." We then calculated prediction accuracy for successful CEI using color Doppler ultrasonography in the LS-PSOV. We also investigated the correlation between the distribution levels measured via color Doppler and fluoroscopy. Results: Prediction accuracy with color Doppler ultrasonography was 96.9%. The sensitivity, specificity, positive predictive value, and negative predictive value were 96.7%, 100%, 100%, and 60.0%, respectively. In 52 of 65 patients (80%), the highest level at which contrast image was observed was the same for both color Doppler ultrasonography and fluoroscopy. Conclusions: Our findings demonstrate that color Doppler ultrasonography in the LS-PSOV is a new method for determining whether a drug solution reaches the lumbosacral region (i.e., the main target level) without the need for fluoroscopy.

The Sensibility Image and Preference Degree of Pattern which Appeared on Men′s Clothing (남성복에 나타난 문양의 감성이미지와 선호도)

  • 박영희
    • Journal of the Korean Society of Costume
    • /
    • v.54 no.4
    • /
    • pp.113-127
    • /
    • 2004
  • This study examined the trend of pattern which appeared throughout men's clothing fashion magazine from 1999 to 2002 and the influence which the demographic characteristic have on the sensibility dimension of pattern and the preference degree of kinds of pattern. The results of study were as follows. 1) The pattern which was used most frequently on recent men's clothing was a length stripe, and the representation technique which was used most frequently on recent men's clothing was the technique of a geometric expression. 2) The pattern which men and women preferred most out of ten kinds of patterns-length stripe, width stripe, oblique stripe, check, square, waterdrop, paisley, flower of style shape, flower of realistic shape, flower of shape-was a length stripe. 3) The sensibility dimension of pattern image was composed of fascination, dignity, daring, gentleness, and reality. 4) Because sensitivity dimension and kinds of pattern were significant according to the distinction of sex, vocation, academic career, income, this study can conclude the demographic characteristic have an influence on sensitivity dimension and kinds of pattern.

Gazing on Photographic Image (사진이미지를 향한 응시)

  • Yang, Young-Chul
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.8
    • /
    • pp.217-226
    • /
    • 2010
  • Reading a photograph is a process of perceiving the image in it. We are able to approach the intention of the photographer only from the sensory material of the image. To make sure how we see the image when we look at a photo, this paper did an experiment with Robert Doisneau's photo, 'Un Regard Oblique'. The hypothesis was set upon the idea of Mary Ann Doane, a pioneer in Gender study. Eye-tracker, Tobii was used to measure the movements and the fixation lengths of the pupils of 44 subjects. From the results of the experiment, it was verified that people look at photographic image in a certain way. At the same time, the gazing strength was differential on every subjects and subject groups.

The correlation of the halo mura and off-axis light leakage level in LCDs with 2D dimmable LED backlight system

  • Kwon, Jang-Un;Byun, Min-Chul;Ham, Jung-Hyun;Baek, Heume-Il;Moon, Hong-Man;Shin, Hyun-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.590-593
    • /
    • 2009
  • In the 2D local dimmable LED backlight system, each LED segment can be controlled separately. This can enhance the contrast ratio and reduce overall power consumption of LCDs. However, an artifact such as 'halo mura' can be observed around the bright object in the dark background. This is caused by the light leakage from the bright area into the dark one. Therefore, the 'halo mura' can be more easily observed in the oblique viewing direction. Thus, in this study, the perceivable degree of the halo mura is evaluated according to the level of the off-axis light leakage of LCDs. It is found that an acceptable degree of halo mura can be obtained in 2.0 cd/$m^2$ of the diagonal light leakage. In addition, the halo mura is unperceivable under 0.7 cd/$m^2$ of the diagonal light leakage which can be achieved with optimally compensated polarizers.

  • PDF

Arbitrary Cross Sectional Display from Three-dimensional Reconstructed Image by Hierarchical Model (계층적 모델에 의한 3차원 재구성 영상의 임의단면 표시)

  • 유선국;김선호
    • Journal of Biomedical Engineering Research
    • /
    • v.10 no.2
    • /
    • pp.157-164
    • /
    • 1989
  • Three-dimensional imaging and manipulation of CT data are becoming increasingly important for deterRing the complex structure and pathologies. Octree which is a hierarchical data model is used to reconstruct three- dimensional objects from CT scans. Orthogonal cross sections are displayed by traverse the octree partially. Arbitrary oblique planes are derived by intersecting the square region of plane and cubic volume of octal node. Thia method enables the display of multi-structured complex organ ann the realization by personal computer.

  • PDF

Color Image Scaling Using Oblique Projection (경사 투영을 사용한 컬러 이미지 스케일링)

  • 김준목;정원용
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2000.12a
    • /
    • pp.53-56
    • /
    • 2000
  • 본 논문에서는 컬러이미지의 스케일링(scaling)을 위해 경사투영방법을 사용하여 기본적인 보간방법, 최소자승근사(least square approximation)의 결과들과 비교하여 보았다. 경사투영방법은 최소의 근사오차(approximation error)를 제공하는 수직투영(orthogonal projection)방법과 유사한 결과를 제공하며 전처리 필터 디자인에 자유성을 부여하고, 좀 더 일반화된 형태의 보간 방법이다. 사용된 방법을 기본적인 보간법들과 비교하여 보았을 때 더 좋은 PSNR의 결과를 얻을 수 있었으며 최소자승근사 방법과 유사한 결과들을 얻을 수가 있었다.

  • PDF

A Study of Fashion Cultural Products Based on the Motif of Traditional Beoseon Socks (전통버선의 형태를 모티브로 한 패션문화상품 디자인 연구)

  • Kim, Sun-Young
    • The Research Journal of the Costume Culture
    • /
    • v.19 no.6
    • /
    • pp.1334-1346
    • /
    • 2011
  • This study focused on the beoseon, traditional Korean socks that are a fashion item showcasing the beauty of the round hanbok shape. The study utilized the beoseon as an influential design motif and suggested 24 cultural fashion items to which the beoseon can be applied, including neckties, scarves, and T-shirts. For the purposes of this study, Adobe Illustrator CS3 and Adobe Photoshop CS3 were used for the motif design as well as the literature review on traditional beoseon socks. For the basic design motif, two basic forms were taken from the collection of the National Folk Museum of Korea. The key point of the motif development is that it maintains the basic shape of the beoseon but highlights the attractiveness of the Korean image by using repetition, rotation, symmetry and overlap into a new image pattern so that modern and chic images were taken into consideration for each cultural product. For the necktie, the mixed or repeated patterns for each motif were used as is. Alternatively, an oblique line pattern was adopted to express a stable and stylish image. For the T-shirt, a round-neck sleeveless type was designed. T-shirts were unified in the white color to highlight the image from the pattern. For the scarf, two shapes were displayed, square and rectangle. Through mixture of two repeated variation unit patterns for each motif, a splendid and stylish image was revealed along with various layouts.

Alternative Method of Retrocrural Approach during Celiac Plexus Block Using a Bent Tip Needle

  • An, Ji Won;Choi, Eun Kyeong;Park, Chol Hee;Choi, Jong Bum;Ko, Dong-Kyun;Lee, Youn-Woo
    • The Korean Journal of Pain
    • /
    • v.28 no.2
    • /
    • pp.109-115
    • /
    • 2015
  • Background: This study sought to determine safe ranges of oblique angle, skin entry point and needle length by reviewing computed tomography (CT) scans and to evaluate the usefulness of a bent tip needle during celiac plexus block (CPB). Methods: CT scans of 60 CPB patients were reviewed. Image of the uppermost margin of L2 vertebral body was used to measure the minimal and maximal oblique angles and the distances from the midline to skin puncture point. The imaginary needle trajectory distance was calculated by three-dimensional measurement. When the procedure was performed by using a $10^{\circ}$ bent tip needle under a $20^{\circ}$ oblique X-ray fluoroscopic view, the distance (GF/G'F) from the midline to the actual puncture site was measured. Results: The imaginary safe oblique angle range was $26.4-34.2^{\circ}$ and $27.7-36.0^{\circ}$ on the right and left, respectively. The distance from the midline to skin puncture point was 6.1-7.6 cm on the right and 6.3-7.6 cm on the left. The needle trajectory distance at minimal angle was 9.6-11.6 cm on the right and 9.5-11.5 cm on the left. The distance of GF/G'F was 5.1-6.5 cm and 5.0-6.4 cm on the right and left, respectively. All imaginary parameters were correlated with BMI except for GF/G'F. All complications were mild and transient. Conclusions: We identified safe values of angles and distances using a straight needle. Furthermore, using a bent tip needle under a $20^{\circ}$ oblique fluoroscopic view, we could safely perform CPB with smaller parameter values.

Three dimensional finite element analysis of the stress distribution around the mandibular posterior implant during non-working movement according to the amount of cantilever

  • Park, Ji-Man;Kim, Hyun-Joo;Park, Eun-Jin;Kim, Myung-Rae;Kim, Sun-Jong
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.5
    • /
    • pp.361-371
    • /
    • 2014
  • PURPOSE. In case of large horizontal discrepancy of alveolar ridge due to severe resorption, cantilevered crown is usually an unavoidable treatment modality. The purpose of this study was to evaluate the clinical criteria for the placement of the aforementioned implant crown. MATERIALS AND METHODS. The mandible model with 2 mm thick cortical bone and cancellous bone was fabricated from CT cross-section image. An external connection type implant was installed and cantilevered crowns with increasing offset of 3, 4, 5, 6, and 7 mm were connected. Vertical load and $30^{\circ}$ oblique load of 300 N was applied and stress around bone and implant component was analyzed. A total of 14 cases were modeled and finite element analysis was performed using COSMOS Works (Solid works Inc, USA). RESULTS. As for the location of the vertical load, the maximum stress generated on the lingual side of the implant became larger according to the increase of offset distance. When the oblique load was applied at $30^{\circ}$, the maximum stress was generated on the buccal side and its magnitude gradually decreased as the distance of the offset load increased to 5 mm. After that point, the magnitude of implant component's stress increased gradually. CONCLUSION. The results of this study suggest that for the patient with atrophied alveolar ridge following the loss of molar teeth, von-Mises stress on implant components was the lowest under the $30^{\circ}$ oblique load at the 5 mm offset point. Further studies for the various crown height and numbers of occusal points are needed to generalize the conclusion of present study.