• Title/Summary/Keyword: ONE-TIME

Search Result 31,293, Processing Time 0.052 seconds

A study on the Enhancement for Minimum Connecting Time of Incheon International Airport (인천국제공항의 MCT 향상을 통한 환승율 제고의 탐색적 연구)

  • Lee, Kang-Suk
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.15 no.4
    • /
    • pp.117-130
    • /
    • 2007
  • Incheon International Airport has handled 3,054,485 transfer passengers (11.9% transfer rate) and 950,441 transfer cargo(44.2% transfer rate)recorded in 2005. Comparing to 30-40% transfer passenger rate which are competition hub airports in northeast Asia, transfer passenger rate of Incheon International Airport is lower. Above all, We think that Minimum Connecting Time(MCT) which is relating factors with transfer rate need to be monitored to make up for the weak points in the current Incheon internationalairport system. Minimum Connecting Time is defined the legally minimum time necessary to change planes at a given airport. and Transfers represent 35% of the total passenger volume at Vienna International Airport in Europe, which underscores our function as a major international hub. Vienna is rated priority in reservation systems because of our excellent minimum connecting time, and that increases the sale of tickets through our airport. In 2004 the total number of transfer passengers rose 18% to 5,089,624. Short routes, a one roof concept and an outstanding logistics system make Vienna an ideal airport for transfers. This transfer-friendly one roof concept will also form the basis for the new VlE-Skylink Terminal. In case of Japan, Star Alliance has also implemented its so called "Move under one roof"concept at the new Centrair airport. All member carriers are located in the same part of the termina1, sharing check-in counters and ticketing facilities. Star Alliance member carriers can now offer customersa reduced average minimum connecting time of one hour, for transfers between international and domestic. The research purpose of the Study on the Enhancement for Minimum Connecting Time of Incheon International Airport is to increase transfer rate of passenger and cargo of Incheon International Airport at Northeast Asia through this paper.

  • PDF

Robust $H_8$State Feedback Congestion Control of ATM for linear discrete-time systems with Uncertain Time-Variant Delay

  • Kang, Lae-Chung;Kim, Young-Joong;Lim, Myo-Taeg
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1758-1763
    • /
    • 2004
  • This paper focuses on congestion control for ATM network with uncertain time-variant delays. The time-variant delays can be distinguished into two distinct components. The first one is represented by time-variant queueing delays in the intermediate switches that are occurred in the return paths of RM cells. The next one is a forward path delay. It is solved by the VBR model which quantifies the data propagation from the sources to the switch. Robust $H_8$ control is studied for solving congestion problem with norm-bounded time-varying uncertain parameters. The suitable robust $H_8$ controller is obtained from the solution of a convex optimization problem through LMI technique.

  • PDF

Performance Analysis of Multirate LQG Control (멀티레이트 LQG 제어 기법의 성능 비교 분석)

  • 이진우;오준호
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.5 no.2
    • /
    • pp.123-130
    • /
    • 1999
  • In discrete-time controlled system, sampling time is one of the critical parameters for control performance. It is useful to employ different sampling rates into the system considering the feasibility of measuring system or actuating system. The systems with the different sampling rates in their input and output channels are named multirate system. Even though the original continuous-time system is time-invariant, it is realized as time-varying state equation depending on multirate sampling mechanism. By means of the augmentation of the inputs and the outputs over one period, the time-varying system equation can be constructed into the time-invariant equation. The two multirate formulations have some trade-offs in the simplicity to construct the controller, the control performance. It is good issue to determine the suitable formulation in consideration of performance of them. In this paper, the two categories of multirate formulations will be compared in terms of the linear quadratic (LQ) cost function. The results are used to select the multirate formulation and the sampling rates suitable to the desired control performance.

  • PDF

Cooperation of Time-delay for Internet-based Mobile Robot Using Fuzzy Logic

  • Yoo, Bong-Soo;Lee, Sang-Min;Joh, Joong-Seon
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.2 no.3
    • /
    • pp.179-184
    • /
    • 2002
  • Recently, internet-based applications can be found easily in various felds. Internet-based telerobot system becomes one of important applications of internet. Among many important technological issues on the internet-based telerobot, time-delay is inherently critical problem to be solved. Time-delay is classified as micro time-delay and macro time-delay in this paper. Algorithms for compensation of path-error and time-error are proposed for the both types of time-delays using fuzzy logic since fuzzy logic is one of the best tools to represent expert's knowledge. Simulation results show the validity of the proposed algorithms.

The Pressure Pain Threshold's Comparison Following Time Progress After IMS to the Trigger Point (동통 유발점에 대한 Intramuscular Stimulation(IMS) 후 시간 경과에 따른 압통 역치에 대한 비교)

  • Hong, Soon-Il;Lee, Hae-Deok
    • Journal of Korean Physical Therapy Science
    • /
    • v.3 no.4
    • /
    • pp.181-187
    • /
    • 1996
  • The purpose of this study is to help understand the pressure pain threshold's comparison following time progress after IMS to the trigger point and recognize this methode' effect for treating these kind of myofascial pain syndrome in clinic. Resently, myofascial pain syndrome is a disease that keeps the highest rate of patients visiting the Department of Rehabilitation Medicine. and so one should understand the change of IMS'effect following time progress for patients to be dealt rightly in clinic. In addition, the theory and treatment of myofascial pain syndrome needs to be understood or to be dealt rightly for therapists to treat and to approach to the right moment in right mode for the patients with myofascial pain syndrome. Therefore, one should know where to stimulate and why one stimulate trigger point and what effect one obtain after IMS.

  • PDF

Forecasting Demand of Childcare Teachers using Time Series Analysis (시계열 분석을 통한 보육교사 수급 전망)

  • Lee, Mee Hwa;Park, Jinah;Kang, Eun Jin
    • Korean Journal of Childcare and Education
    • /
    • v.12 no.6
    • /
    • pp.123-137
    • /
    • 2016
  • The purpose of this study was to forecast demand of childcare teachers based ion four different scenarios. In order to, the demand for childcare teachers from 2015 to 2024 were forecasted using time series techniques with data on the number of childcare teachers from 2003 to 2014. Results were as followings. Firstly, the demand for childcare teachers was expected to increase until 2019, but after 2020 steadily decreased in terms of scenario 1(child teacher ratio regulation). According to scenario 2(child teacher ratio based on 17 cities and provinces), the demand for childcare teachers was expected to need 440 teachers more until 2016. Then, according to scenario 3(two teachers each class), Scenario 4-1(one teacher and one staff each 2 toddler class and 3 older class) and scenario 4-2(one teacher and one staff each class), the demand of childcare teachers and staffs were estimated. These results implicated that childcare teachers and staffs supply policy would be established according to forecast demand.

Finite Element Analysis of Electromagnetic Field Equation with Speed E.M.E (속도기전력을 갖는 전자력 방정식의 유한요소 해석)

  • Hahn, Song-Yop
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.36 no.4
    • /
    • pp.252-258
    • /
    • 1987
  • Time periodic finite element solutions for sinusoidally excited electromagnetic field problems in moving media are presented. Solutions by the Galerkin method contain spurious oscillations when grid Peclet number is more than one. To suppress these oscillations an upwind finite element method using two different time periodic test functions is introduced. One is multiplied to second and first-order space derivative terma and the other to the time derivative term. Test functions are obtained from trial functions by adding or subtracting quadratic bias functions with appropriate scaling factors. Phase differences are considered between trial functions and bias functions. For simple interpretations of the phase differences, complex scaling factors are used. The proposed method is developed to give nodally exact solutions for uniform grid spacing in one dimensional problems. Based on the one dimensional results, a two dimensional upwinding scheme is also derived.

  • PDF

Design of One-Dimensional Systolic Array for Recognition of Context-Free Language (Context-Free 언어의 인식을 위한 일차원 시스토릭 어레이의 설계)

  • 우종호;한광선
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.27 no.1
    • /
    • pp.30-36
    • /
    • 1990
  • Context-free language can be recognized by Cocke-Younger-Kasami algorithm. This algorithm is a class of polyadic-nonserial dynamic programming technique and has the O(n**3) time complexity. In this paper, a one-dimensional systolic array for recognition of context-free language is designed. The designed triangle type two-dimensional array is projected and transformed to an one-dimensional array. The designed one-dimensional array has n processing elements and \ulcornern+1)/2\ulcorner(n-1)+3n-1 time units to process the algorithm (n is the length of input string). The time complexity is O(n\ulcorner.

  • PDF

A Study on PWM Pattern for Driving Induction Motor using ${\mu}$-Processor and One Chip (범용 ${\mu}$-Processor와 One Chip으로 구현되는 유도전동기 구동 PWM Pattern에 관한 연구)

  • Hwang, Y.M.;Hoe, T.W.;Park, J.H.;Shin, D.R.;Cho, Y.G.;Woo, J.I.
    • Proceedings of the KIEE Conference
    • /
    • 1998.11a
    • /
    • pp.179-181
    • /
    • 1998
  • In this paper, one chip PWM pattern generator which eliminates time delay of computations and improves utilization factor of voltage is proposed. Both amplitude of sinusoidal signal and triangular signal are directly controlled. Thus, time delay of computations can be eliminated, and it is possible to track accurately instantaneous current for a sudden change of load with microprocessor 80C196KC. In addition, setting dead-time is also possible for wide range. From experimental work with inverter system for driving induction motor, the validity of proposed one chip PWM pattern generator is verified.

  • PDF

Rates of Recovery of Enterobacter sakazakii (Cronobacter spp.) from Powdered Infant Formula Using Both a Chromogenic Agar and Real-Time PCR : A Preliminary Study

  • Song, Kwang-Young;Seo, Kun-Ho;Chon, Jung-Whan
    • Journal of Dairy Science and Biotechnology
    • /
    • v.39 no.3
    • /
    • pp.113-120
    • /
    • 2021
  • Although the number of incidences of illness caused by ingestion of the bacterial pathogen Enterobacter sakazakii (Cronobacter spp.) has dramatically declined, there remains a need for a robust isolation method to recover this microbe from powdered infant formula (PIF). The current method described in the FDA's Bacteriological Analytical Manual requires multiple steps, and 3-4+ days for complete analysis of PIF isolated E. sakazakii (Cronobacter spp.). We describe a bacteriological method including a one-step enrichment followed by plating on chromogenic agar for presumptive identification of E. sakazakii (Cronobacter spp.). Suspected colonies are confirmed by either biochemical analyses, or a Real-Time PCR-based assay. Using this method, E. sakazakii (Cronobacter spp.) in PIF can be isolated and identified within one day (24 hours).