• Title/Summary/Keyword: OCT

Search Result 1,422, Processing Time 0.035 seconds

Expression and DNA Methylation Change of Oct-4 in Cloned Bovine Blastocysts (체세포복제 소 배반포의 Oct-4 발현과 DNA 메틸화 변화)

  • Cha, Byung-Hyun;Choi, Jung-Sang;Hwang, Seong-Soo;Chung, Hak-Jae;Im, Gi-Sun;Yang, Byong-Chul;Kim, Myong-Jik;Cho, Jae-Hyeon;Seong, Hwan-Hoo;Ko, Yeoung-Gyu
    • Journal of Embryo Transfer
    • /
    • v.23 no.3
    • /
    • pp.133-139
    • /
    • 2008
  • DNA methylation is one of the reasons for poor survival of clone animals. The OCT-4 gene is essential for maintaining pluripotency of embryonic stem (ES) cells and early embryos. We previously reported that the 5'-promoter region of Oct-4 gene was a target of DNA methylation and the methylation status was changed variously during embryonic development in bovine. The study conducted to examine the expression and methylation pattern of tissue-dependent differentially methylated region (T-DMR) of Oct-4 gene in bovine somatic cell nuclear transfer (SCNT) and in vitro fertilization (IVF) blastocysts. The Oct-4 gene expression was evaluated by RT-PCR and fluorescence immunocytochemistry. The methylation pattern of T-DMR was analyzed using restriction mapping and bisulfite sequencing methods. The Oct-4 transcripts were highly expressed in IVF, while they were not expressed in SCNT. The Oct-4 protein was not detected or expressed at very low level in SCNT, the intensity of Oct-4 protein, however, was strong in IVF. On the other hand, the T-DMR of Oct-4 gene was hypermethylated in SCNT compared to that of IVF. These results suggested that expression and the failure of demethylation of Oct-4 gene was closely associated with incomplete development of SCNT embryos.

Evaluation of Morphological Changes in Degenerative Cartilage Using 3-D Optical Coherence Tomography

  • Youn, Jong-In
    • Journal of the Optical Society of Korea
    • /
    • v.12 no.2
    • /
    • pp.98-102
    • /
    • 2008
  • Optical Coherence Tomography (OCT) is an important noninvasive medical imaging technique that can reveal subsurface structures of biological tissue. OCT has demonstrated a good correlation with histology in sufficient resolution to identify morphological changes in articular cartilage to differentiate normal through progressive stages of degenerative joint disease. Current OCT systems provide individual cross-sectional images that are representative of the tissue directly under the scanning beam, but they may not fully demonstrate the degree of degeneration occurring within a region of a joint surface. For a full understanding of the nature and degree of cartilage degeneration within a joint, multiple OCT images must be obtained and an overall assessment of the joint surmised from multiple individual images. This study presents frequency domain three-dimensional (3-D) OCT imaging of degenerative joint cartilage extracted from bovine knees. The 3-D OCT imaging of articular cartilage enables the assembly of 126 individual, adjacent, rapid scanned OCT images into a full 3-D image representation of the tissue scanned, or these may be viewed in a progression of successive individual two-dimensional (2-D) OCT images arranged in 3-D orientation. A fiber-based frequency domain OCT system that provides cross-sectional images was used to acquire 126 successive adjacent images for a sample volume of $6{\times}3.2{\times}2.5\;mm^3$. The axial resolution was $8\;{\mu}m$ in air. The 3-D OCT was able to demonstrate surface topography and subsurface disruption of articular cartilage consistent with the gross image as well as with histological cross-sections of the specimen. The 3-D OCT volumetric imaging of articular cartilage provides an enhanced appreciation and better understanding of regional degenerative joint disease than may be realized by individual 2-D OCT sectional images.

Comparisons of the diagnostic accuracies of optical coherence tomography, micro-computed tomography, and histology in periodontal disease: an ex vivo study

  • Park, Jin-Young;Chung, Jung-Ho;Lee, Jung-Seok;Kim, Hee-Jin;Choi, Seong-Ho;Jung, Ui-Won
    • Journal of Periodontal and Implant Science
    • /
    • v.47 no.1
    • /
    • pp.30-40
    • /
    • 2017
  • Purpose: Optical coherence tomography (OCT) is a noninvasive diagnostic technique that may be useful for both qualitative and quantitative analyses of the periodontium. Micro-computed tomography (micro-CT) is another noninvasive imaging technique capable of providing submicron spatial resolution. The purpose of this study was to present periodontal images obtained using ex vivo dental OCT and to compare OCT images with micro-CT images and histologic sections. Methods: Images of ex vivo canine periodontal structures were obtained using OCT. Biologic depth measurements made using OCT were compared to measurements made on histologic sections prepared from the same sites. Visual comparisons were made among OCT, micro-CT, and histologic sections to evaluate whether anatomical details were accurately revealed by OCT. Results: The periodontal tissue contour, gingival sulcus, and the presence of supragingival and subgingival calculus could be visualized using OCT. OCT was able to depict the surface topography of the dentogingival complex with higher resolution than micro-CT, but the imaging depth was typically limited to 1.2-1.5 mm. Biologic depth measurements made using OCT were a mean of 0.51 mm shallower than the histologic measurements. Conclusions: Dental OCT as used in this study was able to generate high-resolution, cross-sectional images of the superficial portions of periodontal structures. Improvements in imaging depth and the development of an intraoral sensor are likely to make OCT a useful technique for periodontal applications.

Study on Distribution of Oct4 Expression and Change of Apoptosis in Nuclear Transfer Blastocyst using Oct4-Transfected Mesenchymal Stem Cells (Oct4-Transfection한 중간엽줄기세포 유래 핵이식 배반포의 Oct4 발현 분포 및 세포 자멸사의 변화에 관한 연구)

  • Lee, Won-Jae;Lee, Jeong-Hyeon;Rho, Gyu-Jin;Lee, Sung-Lim
    • Journal of Embryo Transfer
    • /
    • v.31 no.1
    • /
    • pp.81-88
    • /
    • 2016
  • There are various factors i.e. donor cell type, culture system as well as technical procedures which influence the pre-implantation embryonic development; however, may attempts have been made and still it is under investigation to improve the cloning efficiency using somatic cell nuclear transfer technique. It is has been investigated that stem cells like mesenchymal stem cell are able to more efficiently reprogram and reactivate the expression of early embryonic genes to promote nuclear transfer efficiency. In addition, Oct4 expression plays a pivotal role in early embryo development. In the present study, we investigated distribution of Oct4 expression and changes of apoptosis and total cell number in nuclear transfer blastocyst after using Oct4 transfected bone marrow stem cell as donor cells. Although Oct4-RFP expression was observed across blastocyst, more concentrated intensity was shown at hatched region in blastocyst on day 7. Reduction of apoptotic bodies was revealed in Oct4 transfected blastocyst by TUNEL staining, however, there was no significant difference in total cell number between Oct4 transfected and non-transfected nuclear transfer embryos. In conclusion, Oct4 transfected donor cells exhibited higher expression in hatching sight in day 7 blastocyst and were able to prevent apoptosis compared to non-transfected donor cells.

Assessment of Early Dental Caries by Using Optical Coherence Tomography (Optical Coherence Tomography를 이용한 초기 치아우식 검사)

  • Min, Ji-Hyun
    • Journal of dental hygiene science
    • /
    • v.16 no.4
    • /
    • pp.257-262
    • /
    • 2016
  • The purpose of this study was to assess the correlation between integrated mineral loss (volume % mineral${\times}{\mu}m$, ${\Delta}Z_{TMR}$) determined using transverse microradiography (TMR) and integrated reflectivity ($dB{\times}{\mu}m$, ${\Delta}R_{OCT}$) determined using optical coherence tomography (OCT) for detecting early dental caries with lesion depth more than $200{\mu}m$. Sixty tooth specimens were made from sound bovine teeth. They were immersed in a demineralized solution for 20, 30, and 40 days. The ${\Delta}R_{OCT}$ was obtained from the cross-sectional OCT image. The ${\Delta}Z_{TMR}$ was obtained from the TMR image. The correlation between ${\Delta}R_{OCT}$ and ${\Delta}Z_{TMR}$ was examined using Pearson correlation. The Bland-Altman plot was constructed using the ${\Delta}R_{OCT}$ and ${\Delta}Z_{TMR}$ values. A significant correlation between ${\Delta}R_{OCT}$ and ${\Delta}Z_{TMR}$ was confirmed (r=0.491, p=0.003). Moreover, most of the difference between ${\Delta}R_{OCT}$ and ${\Delta}Z_{TMR}$ was included in the error section of the Bland-Altman plot. Therefore, OCT could be used as a substitute for TMR when analyzing mineral loss in early dental caries.

Translationally controlled tumor protein (TCTP) downregulates Oct4 expression in mouse pluripotent cells

  • Cheng, Xiang;Li, Junhua;Deng, Jie;Li, Zhenzhen;Meng, Shuyan;Wang, Huayan
    • BMB Reports
    • /
    • v.45 no.1
    • /
    • pp.20-25
    • /
    • 2012
  • The present study aimed to investigate the function of translationally controlled tumor protein (TCTP) in the regulation of Oct4 in mouse embryonic carcinoma P19 cells and mouse J1 embryonic stem (ES) cells. The mRNA level of endogenous TCTP in somatic cells was 2-4 folds higher than that in pluripotent P19 and J1 ES cells. Overexpression of TCTP in mouse pluripotent cells not only reduced the level of Oct4 transcription, but also decreased the pluripotency of stem cells. The N-terminal end of TCTP (amino acids 1-60) played an important role in suppressing the Oct4 promoter. Moreover, overexpression of TCTP in P19 cells suppressed the Oct4 promoter activity in a dose- and a time-dependent manner. In addition, knockdown of TCTP by small interfering RNA increased the expression of Oct4. Our study indicates that TCTP downregulates the Oct4 expression by binding the Sf1 site of Oct4 promoter in mouse pluripotent cells.

Clinical Applications of Intracoronary OCT (Invited Paper) (심혈관 OCT의 임상적 응용)

  • Ha, Jinyong;Kim, Jung-Sun;Hong, Myeong-Ki
    • Korean Journal of Optics and Photonics
    • /
    • v.26 no.1
    • /
    • pp.1-8
    • /
    • 2015
  • The most common cause of a heart attack is known as coronary artery disease, which narrows the arteries and reduces the blood flow to the heart. To treat coronary artery stenosis, percutaneous coronary intervention (PCI) (a nonsurgical procedure to install a stent, which holds the artery wall open) is performed. Intracoronary optical coherence tomography (OCT) is a catheter-based, invasive optical imaging system. To determine whether PCI is appropriate, and to perform stent evaluation in a catheterization laboratory, OCT examinations are carried out. This review details the fundamental principles and technological status of intracoronary OCT imaging, and discusses the ongoing clinical applications to determine the benefits of OCT-guided PCI.

Evaluation of Skin Texture and Wrinkle Using Optical Coherence Tomography (Pilot Study) (피부결 및 주름 평가에 있어 광학단층영상술(Optical Coherence Tomography, OCT) 활용 연구(Pilot Study))

  • Kim, Seunghun;Ahn, Yujin;Sanzhar, Askaruly;Kim, Pilun;Jung, Woonggyu;Lee, Haekwang
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.43 no.3
    • /
    • pp.247-254
    • /
    • 2017
  • Optical Coherence Tomography (OCT) is a non-invasive imaging method that utilizes the optical scattering and interference for visualizing the surface as well as cross-sectional structures of tissue. OCT has been used for diagnosing diseases in early stage in various medical fields, but an application in cosmetics is still at early stage. In this study, OCT was adopted to evaluate skin texture and wrinkle. Results showed similar patterns of evaluation with PRIMOS in the assessment using replica. In addition, OCT produced smaller errors at different angles compared to the PRIMOS in the assessment using 3-dimensional models of wrinkles. The resolution of the image was also high enough to differentiate the images of before and after the application of makeup products. Possible use of OCT in the evaluation of fine wrinkle assessment was studied in this research. Further development of methods is necessary to provide more evidences of the effectiveness.

Implementation of Cost-effective Common Path Spectral Domain Free-hand Scanning OCT System

  • Shoujing Guo;Xuan Liu;Jin U. Kang
    • Current Optics and Photonics
    • /
    • v.7 no.2
    • /
    • pp.176-182
    • /
    • 2023
  • Optical coherence tomography (OCT) is being developed to guide various ophthalmic surgical procedures. However, the high cost of the intraoperative OCT system limits its availability mostly to the largest hospitals and healthcare systems. In this paper, we present a design and evaluation of a low-cost intraoperative common-path free-hand scanning OCT system. The lensed fiber imaging probe is designed and fabricated for intraocular use and the free-hand scanning algorithm that could operate at a low scanning speed was developed. Since the system operates at low frequencies, the cost of the overall system is significantly lower than other commercial intraoperative OCT systems. The assembled system is characterized and shows that it meets the design specifications. The handheld OCT imaging probe is tested on multilayer tape phantom and ex-vivo porcine eyes. The results show that the system could be used as an intraoperative intraocular OCT imaging device.

Development of OCT based on $Opti-Phase^{\circledR}$ OCR module ($Opti-Phase^{\circledR}$ OCR 모듈을 이용한 OCT 시스템 개발)

  • 오정택;황인덕;윤길원;김승우
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.02a
    • /
    • pp.294-295
    • /
    • 2003
  • OCT(Optical Coherence Tomography) 기술은 기본적으로 낮은 가간섭성 광원의 빛을 대상물에 주사하여 피대상물의 내부구조에 따른 각종 광학정 수치를 높은 수직 분해능으로 깊이별로 얻어낼 수 있는 기술이다. 현재 많은 생체 연구그룹에서 OCT의 개발과 응용에 대해 적극적인 연구가 진행 중에 있으며, 그 적용분야를 확대하고 있는 추세이다. OCT에 관련된 대표적인 연구분야로서 조직의 미세 단층영상, 혈류 가시화 및 각종 생체조직에 따른 복굴절율 변화 측정 등이 있다.(중략)

  • PDF