• Title/Summary/Keyword: Nuclear medicine image

Search Result 615, Processing Time 0.041 seconds

A Research of Standards for Radiopharmaceutical Doses in Pediatric Nuclear Medicine (소아 핵의학 검사 시 사용되는 방사성의약품의 양 산출 기준 조사)

  • Do, Yong-Ho;Kim, Gye-Hwan;Lee, Hong-Jae;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.47-50
    • /
    • 2009
  • Purpose: Presently, any exact standard of radiopharmaceutical doses in pediatric nuclear medicine doesn't exist in the universe. So hospitals are following by manual of vial kit or guidelines of America and Europe based on recommended adult doses adjusted for body mass (MBq/kg) or body surface area (MBq/$m^2$). However, especially for children younger than 1 year and heavier than 50 kg, it's hard to estimate exact dosage for those children. Materials and Methods: In order to obtain objective data of multipliers for pediatric studies, we surveyed 4 major hospitals in Korea. After receiving feedbacks, we changed dosage to multiplier. And we compared multipliers of Korea to America's and Europe's. Results: Most hospitals in Korea are following by body mass formula (MBq/kg). On the other hand, standards don't include proper factors for a child younger than 1 year and heavier than 50 kg. Multipliers for 3 kg children who are injected lower doses than needed are America:0.12, Europe:0.09, Korea:0.05, multipliers for 30 kg children who are injected proper doses are America:0.58, Europe:0.51, Korea:0.45 and multipliers for 60 kg children who are injected more doses than needed are America:0.95, Europe:0.95, Korea:0.91. Conclusions : Through the survey, when calculating doses for children, usually output doses are based on adult doses adjusted for body mass (MBq/kg) but research has shown that standards of all of the compared standards don't reflect exact multipliers for children younger than 1 year and heavier than 50 kg. Therefore, we should give an effort to reduce needless radiation exposure in children by establishing a proper doses standard and also developing better image reconstruction software.

  • PDF

Assessment of Hydroureteronephrosis in Children Using Diuretic Radionuclide Ureterography (동위원소 이뇨 요관그람을 이용한 소아 요관폐쇄의 평가)

  • Kim, Jong-Ho;Lee, Dong-Soo;Kwark, Cheol-Eun;Lee, Kyung-Han;Choi, Chang-Woon;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon;Choi, Yong;Choi, Hwang
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.1
    • /
    • pp.75-84
    • /
    • 1994
  • The need for assessment of ureteric function in the patient with an obviousely dilated ureter has increased particularly with the added spectrum of asymptomatic patients presenting with hydrone-phrosis and hydroureter on antenatal and perinatal ultrasound. To assess the influence of ureteral status on kidney washout during $^{99m}Tc$-DTPA diuretic renography, ureteral images were reviewed in 80 children referred for hydronephrosis. A scintigraphically abnormal ureter was defined as an intense and continuous image of > 10 min during diuretic renography. Out of them, a total of 16 nephroureteral systems in 12 children with scintigraphically abnormal ureter were analyzed. A diuretic washout index using response half time (t1/2) by linear fitting after lasix injection, was determined on renal (Kt1/2) and ureteral (Ut1/2) curves (diuretic renogram vs. diuretic ureterogram). Diuretic ureterogram curve patterns corresponding to normal (type I), obstructive (II) and non-obstructive (III) cases were described. Compared with X-ray data, diuretic renography was highly sensitive (88%) and specific (99%) for detecting any ureteral abnormality. Despite an obstructive Kt1/2 (>20 min), no patient with an abnormal ureter underwent therapy at the ureteropelvic junction because the hydronephrosis regressed after surgery at the lower level. Our data indicate that the abnormal ureter findings during diuretic renography have to be recognized before therapy for children with hydeonephrosis.

  • PDF

Building the Process for Reducing Whole Body Bone Scan Errors and its Effect (전신 뼈 스캔의 오류 감소를 위한 프로세스 구축과 적용 효과)

  • Kim, Dong Seok;Park, Jang Won;Choi, Jae Min;Shim, Dong Oh;Kim, Ho Seong;Lee, Yeong Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.76-82
    • /
    • 2017
  • Purpose Whole body bone scan is one of the most frequently performed in nuclear medicine. Basically, both the anterior and posterior views are acquired simultaneously. Occasionally, it is difficult to distinguish the lesion by only the anterior view and the posterior view. In this case, accurate location of the lesion through SPECT / CT or additional static scan images are important. Therefore, in this study, various improvement activities have been carried out in order to enhance the work capacity of technologists. In this study, we investigate the effect of technologist training and standardized work process processes on bone scan error reduction. Materials and Methods Several systems have been introduced in sequence for the application of new processes. The first is the implementation of education and testing with physicians, the second is the classification of patients who are expected to undergo further scanning, introducing a pre-filtration system that allows technologists to check in advance, and finally, The communication system called NMQA is applied. From January, 2014 to December, 2016, we examined the whole body bone scan patients who visited the Department of Nuclear Medicine, Asan Medical Center, Seoul, Korea Results We investigated errors based on the Bone Scan NMQA sent from January 2014 to December 2016. The number of tests in which NMQA was transmitted over the entire bone scan during the survey period was calculated as a percentage. The annual output is 141 cases in 2014, 88 cases in 2015, and 86 cases in 2016. The rate of NMQA has decreased to 0.88% in 2014, 0.53% in 2015 and 0.45% in 2016. Conclusion The incidence of NMQA has decreased since 2014 when the new process was applied. However, we believe that it will be necessary to accumulate data continuously in the future because of insufficient data until statistically confirming its usefulness. This study confirmed the necessity of standardized work and education to improve the quality of Bone Scan image, and it is thought that update is needed for continuous research and interest in the future.

  • PDF

Detection of Atherosclerotic Lesion with $^{99m}Tc-LDL$ Scintigraphy ($^{99m}Tc-LDL$ (Low Density Lipoprotein)신티그라피를 이용한 동맥경화병소 진단)

  • Kim, Deog-Yoon;Koh, Eun-Mi;Woo, Jeong-Taek;Kim, Sung-Woon;Yang, In-Myung;Kim, Jin-Woo;Kim, Young-Seol;Kim, Kwang-Won;Choi, Young-Kil
    • The Korean Journal of Nuclear Medicine
    • /
    • v.26 no.2
    • /
    • pp.257-264
    • /
    • 1992
  • Diagnostic approaches such as angiography, ultrasound, computed tomography and nuclear magnetic resonance have limitation for contributing to the early clinical diagnosis of atherosclerosis. Recently, $^{99m}Tc-labelled$ low density lipoprotein was developed to detect early atherosclerotic lesion by external imaging with gamma camera. To determine whether $^{99m}Tc-LDL$ scintigraphy can visualize the active atherosclerotic lesion, rabbits were injected with $^{99m}Tc-LDL$, 3 months after feeding dietary fat (lanolin) and we obtained following results. 1) Labelling efficiency of $^{99m}Tc-LDL$ was $79\sim88%$. 2) Biodistribution study of normal rabbits with $^{99m}Tc-LDL$ revealed the high activities in spleen, adrenal gland, liver, kidney which are major organs of high metabolic rate of LDL. 3) Three months after feeding lanolin, serum cholesterol was markedly increased from $74{\pm}17mg/dl$ to $979{\pm}153mg/dl$ and histologic study of aorta after sacrificing the rabbit demonstrated marked atherosclerotic changes. 4) Atherosclerotic lesion of abdominal aorta which was confirmed with histologic study could be demonstrated in $^{99m}Tc-LDL$ scintigraphy after feeding lanolin for 3 months. In conclusion, the results of this preliminary investigation suggest that it may be possible to image active atheromatous lesion with $^{99m}Tc-LDL$. It is anticipated that this promising agent may allow the in vivo monitoring of preclinical atherosclerotic lesions and may be useful to evaluate the metabolic pathway of LDL in humans.

  • PDF

Diagnostic Accuracy of Rest T1-201/Stress Tc-99m-MIBI Myocardial SPECT in the Diagnosis of Coronary Artery Disease (휴식 T1-201/부하 Tc-99m MIBI 심근 SPECT의 관상동맥질환 진단 정확성)

  • Yeo, Jeong-Seok;Lee, Dong-Soo;Kang, Keon-Wook;Sohn, Dae-Won;Oh, Byung-Hee;Lee, Myung-Mook;Chung, June-Key;Park, Young-Bae;Lee, Myung-Chul;Seo, Jung-Don;Lee, Young-Woo;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.1
    • /
    • pp.112-117
    • /
    • 1996
  • Objective: Standard stress/rest Tc-99m MIBI and T1-201 myocardial perfusion study have some limitations such as stress/rest image overlap for Tc-99m-MIBI, low energy for T1-201 and long period of study time for two separate studies. Separate acquisition rest T1-201/stress Tc-99m MIBI dual isotope study is a potentially efficient myocardial perfusion imaging protocol that combines the high resolution of Tc-99m for stress perfusion assessment and T1-201 for viability assessment. This study assessed the usefulness and diagnostic accuracy for this new approach. Methods: We tried to evaluate sensitivity and specificity of dual isotope separate acquisition protocol in 67 patients. Immediately after resting T1-201 SPECT data was acquired, dipyridamole stress Tc-99m MIBI myocardial perfusion study was performed. Visual analysis was carried out qualitatively with 0 to 3 scoring system for 17 segments of left ventricle in the reconstructed horizontal long axis and short axis slices. Results: Total study was completed within 3 hours. In angiographic correlation, dual isotope SPECT demonstrated high sensitivity(85%) and in a small group of patients, high specificity was also observed (100%). Conclusion: Combined thallium-201/stress Tc-99m MIBI SPECT displayed similiar diagnostic accuracy to protocol using stress/rest Tc-99m MIBI SPECT. This protocol was completed in shorter period than the previous protocols and therefore enhance laboratory throughput and patients convenience.

  • PDF

Strategies to improve the range verification of stochastic origin ensembles for low-count prompt gamma imaging

  • Hsuan-Ming Huang
    • Nuclear Engineering and Technology
    • /
    • v.55 no.10
    • /
    • pp.3700-3708
    • /
    • 2023
  • The stochastic origin ensembles method with resolution recovery (SOE-RR) has been proposed to reconstruct proton-induced prompt gammas (PGs), and the reconstructed PG image was used for range verification. However, due to low detection efficiency, the number of valid events is low. Such a low-count condition can degrade the accuracy of the SOE-RR method for proton range verification. In this study, we proposed two strategies to improve the reconstruction of the SOE-RR algorithm for low-count PG imaging. We also studied the number of iterations and repetitions required to achieve reliable range verification. We simulated a proton beam (108 protons) irradiated on a water phantom and used a two-layer Compton camera to detect 4.44-MeV PGs. Our simulated results show that combining the SOE-RR algorithm with restricted volume (SOE-RR-RV) can reduce the error of the estimation of the Bragg peak position from 5.0 mm to 2.5 mm. We also found that the SOE-RR-RV algorithm initialized using a back-projection image could improve the convergence rate while maintaining accurate range verification. Finally, we observed that the improved SOE-RR algorithm set for 60,000 iterations and 25 repetitions could provide reliable PG images. Based on the proposed reconstruction strategies, the SOE-RR algorithm has the potential to achieve a positioning error of 2.5 mm for low-count PG imaging.

The Evaluation of Quantitative Accuracy According to Detection Distance in SPECT/CT Applied to Collimator Detector Response(CDR) Recovery (Collimator Detector Response(CDR) 회복이 적용된 SPECT/CT에서 검출거리에 따른 정량적 정확성 평가)

  • Kim, Ji-Hyeon;Son, Hyeon-Soo;Lee, Juyoung;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.2
    • /
    • pp.55-64
    • /
    • 2017
  • Purpose Recently, with the spread of SPECT/CT, various image correction methods can be applied quickly and accurately, which enabled us to expect quantitative accuracy as well as image quality improvement. Among them, the Collimator Detector Response(CDR) recovery is a correction method aiming at resolution recovery by compensating the blurring effect generated from the distance between the detector and the object. The purpose of this study is to find out quantitative change depending on the change in detection distance in SPECT/CT images with CDR recovery applied. Materials and Methods In order to find out the error of acquisition count depending on the change of detection distance, we set the detection distance according to the obit type as X, Y axis radius 30cm for circular, X, Y axis radius 21cm, 10cm for non-circular and non-circular auto(=auto body contouring, ABC_spacing limit 1cm) and applied reconstruction methods by dividing them into Astonish(3D-OSEM with CDR recovery) and OSEM(w/o CDR recovery) to find out the difference in activity recovery depending on the use of CDR recovery. At this time, attenuation correction, scatter correction, and decay correction were applied to all images. For the quantitative evaluation, calibration scan(cylindrical phantom, $^{99m}TcO_4$ 123.3 MBq, water 9293 ml) was obtained for the purpose of calculating the calibration factor(CF). For the phantom scan, a 50 cc syringe was filled with 31 ml of water and a phantom image was obtained by setting $^{99m}TcO_4$ 123.3 MBq. We set the VOI(volume of interest) in the entire volume of the syringe in the phantom image to measure total counts for each condition and obtained the error of the measured value against true value set by setting CF to check the quantitative accuracy according to the correction. Results The calculated CF was 154.28 (Bq/ml/cps/ml) and the measured values against true values in each conditional image were analyzed to be circular 87.5%, non-circular 90.1%, ABC 91.3% and circular 93.6%, non-circular 93.6%, ABC 93.9% in OSEM and Astonish, respectively. The closer the detection distance, the higher the accuracy of OSEM, and Astonish showed almost similar values regardless of distance. The error was the largest in the OSEM circular(-13.5%) and the smallest in the Astonish ABC(-6.1%). Conclusion SPECT/CT images showed that when the distance compensation is made through the application of CDR recovery, the detection distance shows almost the same quantitative accuracy as the proximity detection even under the distant condition, and accurate correction is possible without being affected by the change in detection distance.

  • PDF

Preliminary Study on Performance Evaluation of a Stacking-structure Compton Camera by Using Compton Imaging Simulator (Compton Imaging Simulator를 이용한 다층 구조 컴프턴 카메라 성능평가 예비 연구)

  • Lee, Se-Hyung;Park, Sung-Ho;Seo, Hee;Park, Jin-Hyung;Kim, Chan-Hyeong;Lee, Ju-Hahn;Lee, Chun-Sik;Lee, Jae-Sung
    • Progress in Medical Physics
    • /
    • v.20 no.2
    • /
    • pp.51-61
    • /
    • 2009
  • A Compton camera, which is based on the geometrical interpretation of Compton scattering, is a very promising gamma-ray imaging device considering its several advantages over the conventional gamma-ray imaging devices: high imaging sensitivity, 3-D imaging capability from a fixed position, multi-tracing functionality, and almost no limitation in photon energy. In the present study, a Monte Carlo-based, user-friendly Compton imaging simulator was developed in the form of a graphical user interface (GUI) based on Geant4 and $MATLAB^{TM}$. The simulator was tested against the experimental result of the double-scattering Compton camera, which is under development at Hanyang University in Korea. The imaging resolution of the simulated Compton image well agreed with that of the measured image. The imaging sensitivity of the measured data was 2~3 times higher than that of the simulated data, which is due to the fact that the measured data contains the random coincidence events. The performance of a stacking-structure type Compton camera was evaluated by using the simulator. The result shows that the Compton camera shows its highest performance when it uses 4 layers of scatterer detectors.

  • PDF

Quantitative Indices of Small Heart According to Reconstruction Method of Myocardial Perfusion SPECT Using the 201Tl (201Tl을 이용한 심근관류 SPECT에서 재구성 방법에 따른 작은 용적 심장의 정량 지표 변화)

  • Kim, Sung Hwan;Ryu, Jae Kwang;Yoon, Soon Sang;Kim, Eun Hye
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.18-24
    • /
    • 2013
  • Purpose: Myocardial perfusion SPECT using $^{201}Tl$ is an important method for viability of left ventricle and quantitative evaluation of cardiac function and now various reconstruction methods are used to improve the image quality. But in case of small sized heart, you should always be careful because of the Partial Volume Effect which may cause errors of quantitative indices at the reconstruction step. So, In this study, we compared those quantitative indices of left ventricle according to the reconstruction method of myocardial perfusion SPECT with the Echocardiography and verified the degree of the differences between them. Materials and Methods: Based on ESV 30 mL of Echocardiography, we divided 278 patients (male;98, female;188, Mean age;$65.5{\pm}11.1$) who visited the Asan medical center from February to September, 2012 into two categories; below the criteria to small sized heart, otherwise, normal or large sized heart. Filtered and output each case, we applied the method of FBP and OSEM to each of them, and calculated EDV, ESV and LVEF, and we conducted statistical processing through Repeated Measures ANOVA with indices that measured in Echocardiography. Results: In case of men and women, there were no significant difference in EDV between FBP and OSEM (p=0.053, p=0.098), but in case of Echocardiography, there were meaningful differences (p<0.001). The change of ESV especially women in small sized heard, significant differences has occurred among FBP, OSEM and Echocardiography. Also, in LVEF, there were no difference in men and women who have normal sized heart among FBP, OSEM and Echocardiography (p=0.375, p=0.969), but the women with small sized heart have showed significant differences (p<0.001). Conclusion: The change in quantitative indices of left ventricle between Nuclear cardiology image reconstruction, no difference has occurred in the patients with normal sized heart but based on ESV, under 30 mL of small sized heart, especially in female, there were significant differences in FBP, OSEM and Echocardiography. We found out that overestimated LVEF caused by PVE can be reduced in average by applying OSEM to all kinds of gamma camera, which are used in analyzing the differences.

  • PDF