• Title/Summary/Keyword: Ns-2

Search Result 1,725, Processing Time 0.028 seconds

A Wilkinson-Type Balun Using a Composite Right/Left-Handed Transmission Line

  • Park, Unghee
    • Journal of information and communication convergence engineering
    • /
    • v.11 no.3
    • /
    • pp.147-152
    • /
    • 2013
  • A novel balun being the structure of a Wilkinson power divider is suggested and fabricated. One of the power dividing paths in the suggested balun uses a conventional ${\lambda}/4$ transmission line for $-90^{\circ}$ phase shifting, and the other path uses a composite right/left-handed -${\lambda}/4$ transmission line for $+90^{\circ}$ phase shifting with four series capacitors and three parallel inductors. In addition, the suggested balun uses two $50-{\Omega}$ resistors and a conventional $50-{\Omega}$ transmission line of ${\lambda}/2$ electrical length between the two output ports, achieving good isolation and reflection values of two balanced ports. The suggested balun is simulated by the advanced design system simulation program and fabricated on TLX-9 20-mil substrate. The fabricated balun has a very good values of $S_{11}$ = -27.46 dB, $S_{21}$ = -3.40 dB, and $S_{31}$ = -3.28 dB, a phase difference of $-179.5^{\circ}$, a magnitude difference of 0.12 dB, and a delay difference of 0.1 ns, with $S_{22}$ = -36.28 dB, $S_{33}$ = -27.19 dB, and $S_{32}$ = -25.2 dB at 1 GHz, respectively.

Geologic Report of the Second Yeonhwa Mine, Kangwon Province, Korea (제이연화광산(第二蓮花鑛山)의 지질광상(地質鑛床)에 대(對)하여)

  • Han, Kab Soo
    • Economic and Environmental Geology
    • /
    • v.5 no.4
    • /
    • pp.211-217
    • /
    • 1972
  • The Second Yeon Hwa Mine which belongs to a so called Lead-Zines Belt Area in the central east Korea is located at about 10 km northeast of the Seogpo railway station on Yeongdong Line. The exploitation of the mine started in June, 1969 and furnished the machinary ore dressing plant in November, 1971. The current monthly production of rude ore is 15,000 meteric tons. The results of the study on the lead-zinc-copper deposits of the Second Yeonhwa mine are summerized as follows: (1) main ore deposits of the mine are localized in the Pungchon Limestion formation of Cambrian age, (2) related ingneous rock with ore deposits is granite porphyry, which distributed in NS and $N50^{\circ}W$ trend, (3) ore solution ascended along the $N50^{\circ}W$ trend which represents folding axis and fault plane and mineralized selectively in the limestone formation. (4) high grade ore deposits are localized in concave and convex boundaries of granite porphyry, and hanging walls of shale bed ($P_2S$ shale bed) in Pungchon Limestone formation and (5) skarn minerals are consisted of garnet, hedenbergite, diopside, and sulfide minerals are composed of zincblenede, galena, phyrhotite, pyrite and some amount of chalcopyrite and arsenopyrite.

  • PDF

Generation of Ultrawide Band Electromagnetic Pulse from Blumlein Pulse Forming Line

  • Jin, Yun Sik;Kim, Jong Soo;Cho, Chuhyun;Roh, Young Su
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.677-681
    • /
    • 2014
  • A high voltage pulse generator was fabricated to radiate ultrawide band electromagnetic pulse. A coaxial type of Blumlein pulse forming line is employed to produce a pulse of high voltage (>300 kV) and short pulse duration (~5 ns). A helical strip/wire type of air-cored pulse transformer was used to charge the Blumlein pulse forming line up to more than 300 kV. A peaking switch is essential to make the pulse rise time as fast as possible. Typically, the rise time is ~500 ps. The output pulse of the generator is radiated into air through an exponentially tapered TEM horn antenna. The electric field intensity of a radiated pulse was measured as a function of the distance from the transmitting horn as well as the output voltage of the peaking switch. The peak-to-peak value of the electric field intensity at 10 m from the TEM antenna was~100 kV/m.

PROTEIN CONFORMATIONS OF OCTOPUS RHODOPSIN AND ITS DEPROTONATED PHOTOCYCLE INTERMEDIATE MONITORED BY ABSORPTION AND PROTEIN FLUORESCENCE

  • Jang, Du-Jeon;Lee, SunBae
    • Journal of Photoscience
    • /
    • v.2 no.1
    • /
    • pp.19-25
    • /
    • 1995
  • Picosecond time-resolved and static protein fluorescence spectra and absorption spectra of octopus rhodopsin, a photorecepting protein, are measured and compared with those of bacteriorhodopsin, a photon-induced proton pumping protein, to understand the protein conformations and functions of octopus rhodopsin and its deprotonated photocycle intermediate. The bluer and weaker absorption of retinal indicates that octopus rhodopsin is better in thermal noise suppression but less efficient in light harvesting than bacteriorhodopsin. The protein fluorescence of octopus rhodopsin shows the characteristic of Trp only and the uantum efficiency and lifetime variations may result primarily from variations in the coupling strength with the retinal. The stronger intensity by four times and larger red shift by 12 nm of fluorescence suggest that octopus rhodopsin has more open and looser structure compared with bacteriorhodopsin. Fluorescence decay profiles reveal two decay components of 300 ps (60%) and 2 ns (40%). The deprotonation of protonated Schiff's base increases the shorter decay time to 500 ps and enhances the fluorescence intensity by 20%. The fluorescence and its decay time from Trp residues near retinal are influenced more by the deprotonation. The increase of fluorescence intimates that protein structure becomes loosened and relaxed further by the deprotonation of protonated Schiff's base. The driving force of sequential changes initiated by absorption of a photon is too exhausted after the deprotonation to return the intermediate to the ground state of the begun rhodopsin form.

  • PDF

The Therapeutic Role of Nanoparticle Shape in Traumatic Brain Injury : An in vitro Comparative Study

  • Youn, Dong Hyuk;Jung, Harry;Tran, Ngoc Minh;Jeon, Jin Pyeong;Yoo, Hyojong
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.2
    • /
    • pp.196-203
    • /
    • 2022
  • Objective : To perform a comparative analysis of therapeutic effects associated with two different shapes of ceria nanoparticles, ceria nanorods (Ceria NRs) and ceria nanospheres (Ceria NSs), in an in vitro model of traumatic brain injury (TBI). Methods : In vitro TBI was induced using six-well confluent plates by manually scratching with a sterile pipette tip in a 6×6-square grid. The cells were then incubated and classified into cells with scratch injury without nanoparticles and cells with scratch injury, which were treated separately with 1.16 mM of Ceria NSs and Ceria NRs. Antioxidant activities and anti-inflammatory effects were analyzed. Results : Ceria NRs and Ceria NSs significantly reduced the level of reactive oxygen species compared with the control group of SH-SY5Y cells treated with Dulbecco's phosphate-buffered saline. The mRNA expression of superoxide dismutases was also reduced in nanoparticle-treated SH-SY5Y cells, but apparently the degree of mRNA expression decrease was not dependent on the nanoparticle shape. Exposure to ceria nanoparticles also decreased the cyclooxygenase-2 expression, especially prominent in Ceria NR-treated group than that in Ceria NS-treated group. Conclusion : Ceria nanoparticles exhibit antioxidant and anti-inflammatory effects in TBI models in vitro. Ceria NRs had better anti-inflammatory effect than Ceria NSs, but showed similar antioxidant activity.

Performance evaluation of an adjustable gantry PET (AGPET) for small animal PET imaging

  • Song, Hankyeol;Kang, In Soo;Kim, Kyu Bom;Park, Chanwoo;Baek, Min Kyu;Lee, Seongyeon;Chung, Yong Hyun
    • Nuclear Engineering and Technology
    • /
    • v.53 no.8
    • /
    • pp.2646-2651
    • /
    • 2021
  • A rectangular-shaped PET system with an adjustable gantry (AGPET) has been developed for imaging small animals. The AGPET system employs a new depth of interaction (DOI) method using a depth dependent reflector patterns and a new digital time pickoff method based on the pulse reconstruction method. To evaluate the performance of the AGPET, timing resolution, intrinsic spatial resolution and point source images were acquired. The timing resolution and intrinsic spatial resolution were measured using two detector modules and Na-22 gamma source. The PET images were acquired in two field of view (FOV) sizes, 30 mm and 90 mm, to demonstrate the characteristic of the AGPET. As a result of in the experiment results, the timing resolution was 0.9 ns using the pulse reconstruction method based on the bi-exponential model. The intrinsic spatial resolution was an average of 1.7 mm and the spatial resolution of PET images after DOI correction was 2.08 mm and 2.25 mm at the centers of 30 mm and 90 mm FOV, respectively. The results show that the proposed AGPET system provided higher sensitivity and resolution for small animal imaging.

285 mJ Electro-optically 𝚀-switched Er:YAG Master Oscillator Power Amplifier (MOPA) System with Adjustable Pumping Delay between Flashlamps at 2.94 ㎛

  • Heesuk Jang;Hajun Song;Hae Seog Koh;Han Young Ryu
    • Current Optics and Photonics
    • /
    • v.7 no.3
    • /
    • pp.297-303
    • /
    • 2023
  • In this paper, we demonstrated a high-energy (285 mJ) mid-infrared flashlamp-pumped electro-optically 𝚀-switched Er:YAG master oscillator power amplifier (MOPA) system and comprehensively investigated its temporal, spectral, and spatial characteristics. To increase the output energy, we optimized the delay between the timings at which the flashlamps of the master oscillator and power amplifier were triggered. In addition, the output energy was improved while minimizing thermal effects by cooling the MOPA system to a temperature slightly above the dew point. Consequently, the MOPA structure boosted the output energy without damaging the lithium niobate Pockels cell, which is a crucial element in 𝚀-switching. This design realized pulses with energies up to 0.285 J and pulse durations of approximately 140 ns at a wavelength of 2,936.7 nm. This high-energy mid-IR Er:YAG MOPA system can be used for various scientific, engineering, and military underwater applications.

Incidence and Risk Factors for Surgical Glove Perforation (수술용 장갑의 천공률에 대한 연구)

  • Yoo, Seon Ju;Lim, Young Shin;Kim, Myung Suk
    • Journal of Korean Clinical Nursing Research
    • /
    • v.16 no.3
    • /
    • pp.63-71
    • /
    • 2010
  • Purpose: This study was conducted to evaluate the incidence and risk factors for surgical glove perforation during operation. Methods: During the month of december 2008, a total of 1,400 pairs of surgical gloves used in major operations was collected in a tertiary hospital. All gloves were examined immediately after operation using the standardized water-leak method to detect any perforation. Incidence of the glove perforation was counted according to the type of operation, operation time, the number of involved personnel, perforation sites, and the manufacturing companies. Results: Out of 2,800 gloves examined, 312 perforations were detected comprising 11.1% of samples. In terms of the type of operation, the perforation incidence varied from 5% to 20%, and the perforation rates in CS (20%) and NS (18%) (p<.001) were significantly higher than those in other departments. The 1st assistant or scrub nurse got glove perforation more frequently than the 2nd assistant or operator (p<.001). Longer operation time was associated with higher incidence of perforation evidently (p<.001). In terms of the sites, the thumb and index finger were more frequently perforated than other sites (4.1% and 3.4% respectively) without any differences between left and right side. Conclusion: Risk factors for glove perforation including the department of operation, operation time, participating personnel, and location of perforation should be taken into account to improve surgical safety.

Dynamism Competent LEACH Replication Deliberate for Wireless Sensor Network

  • KONDA HARI KRISHNA;TAPSI NAGPAL;Y. SURESH BABU
    • International Journal of Computer Science & Network Security
    • /
    • v.23 no.5
    • /
    • pp.7-12
    • /
    • 2023
  • Remote sensor systems are utilized in a few applications, including military, restorative, ecological and family unit. In every one of these applications, vitality use is the deciding component in the execution of wireless sensor systems. Thusly, strategies for information steering and exchanging to the base station are critical in light of the fact that the sensor hubs keep running on battery control and the vitality accessible for sensors is constrained. There are two explanations for the various leveled directing Low Energy Adaptive Clustering Hierarchy convention be in investigated. One, the sensor systems are thick and a considerable measure of excess is engaged with correspondence. Second, with a specific end goal to build the versatility of the sensor arrange remembering the security parts of correspondence. In this exploration paper usage of LEACH steering convention utilizing NS2 test system lastly upgraded vitality productive EE-LEACH directing convention guarantees that the chose cluster heads will be consistently conveyed over the system with a specific end goal to enhance the execution of the LEACH convention. EE-LEACH enhances vitality utilization by around 43%.

A Study on the Surgical Hand Scrub and Surgical Glove Perforation (외과적 손씻기 및 외과용 장갑의 천공율에 대한 연구)

  • 윤혜상
    • Journal of Korean Academy of Nursing
    • /
    • v.25 no.4
    • /
    • pp.653-667
    • /
    • 1995
  • Post - operative wound infections have been a serious problem in nursing care in the operating room and appear to be strongly related to the infection occurring during the performance of operation. The purpose of this study is to identify patterns in duration of surgical hand scrub (SHS), to evaluate the method of SHS and to examine the rate of glove perforation. Subjects for this study include 244 doctors and 169 nurses working in the operative theatre of a hospital in Seoul area. Test samples and related data were collected from this medical facility between April 1, through 15, and July 1, through 5, 1995 by the author and a staff member working in the operating room. For the study, data on the SHS of doctors and nurses were obtained at the time of operation and multiple batches of surgical gloves worn by the operating doctors were collected after each operation. The duration of SHS was measured with a stop watch and the method of SHS was evaluated according to Scoring Hand Scrub Criteria (SHS Criteria) and expressed as SHS scores. For the analysis of the data, t-test was used to compare the differences in the duration and the SHS scores of doctors and nurses, and Pearson's correlation coefficient was used to examine the relationship between the SHS duration and the SHS scores. The results of the study are summarized as follows. 1) The mean time spent in each SHS was 167 seconds in nurses, and 127 seconds in doctors. The data comparing nurses and doctors indicated that there were significant differences in Our ation of SH S between these two groups (t=5.58, p=.000). 2) The mean time spent in the first SHS was 145 seconds and that in the End SHS, 135 seconds, and there was not a significant difference in the duration of the SHS between doctors and nurses (t=1.44, P=.156). 3) The mean time spent in the SHS by OS (Orthopaedic surgery) doctors was 162 seconds, 150 seconds by NS(Neurologic surgery), 121 seconds by GS(General surgery), 94 seconds by OPH(Opthalmology) and DS(Dental surgery), 82 seconds by URO(Urology), 78 seconds by PS(Plastic surgery) and 40 seconds by ENT(Ear, Nose & Throat) These also showed a significant difference in the duration of the SHS among the medical specialities (t=4.8, P=.0001). 4) The average SHS score of the nurses was 15.2, while that of doctors was 13.1. The statistical analysis showed that t-value was 3.66, p was. 000. This indicates that the nurses actually clean their hands more thoroughly than the doctors do. 5) The average SHS score of NS doctors was 15.5, 15.3 for doctors for OPH,14.3 for OS,12.7 for GS, 12.0 for DS, 11.7 for URO, 10.1 for PS, 7.5 for ENT. Comparison of the average SHS scores from 8 specialties showed that there was a significant differences in the patterns of the SHS (F=5.08, P=.000) among medical specialties. 6) It appears that the operating personnel scrub the palms and dorsum of their hand relatively well, however, less thorough the nails and fingers. 7) The more the operating personnel spend their time in hand scrubbing, the more correctly they clean their hands(r=.6427, P<.001). 8) The overall frequencies of perforation in all post-operative gloves tested was 38 out of 389 gloves (10.3%). The perforation rate for PS was 13%, 12.1% for GS,8.8% for 05, and 3.3% for NS.

  • PDF